1.
IEEE Trans Biomed Circuits Syst ; 16(6): 1166-1180, 2022 12.
Article in English | MEDLINE | ID: mdl-36395127

ABSTRACT

For the wireless power transfer (WPT) system in implantable medical devices (IMDs), human tissue is positioned between the transmitting and receiving coils which are different from general WPT systems. Because this space is where the strongest electromagnetic field (EMF) occurs, it is essential to reduce the EMF at the interspace to reduce human exposure to the EMF. In this paper, an out-of-phase coupled WPT system for IMDs is proposed to reduce human exposure to EMF. Considering the EMF exposure and power transfer efficiency (PTE) of the proposed system, a design procedure for determining the phase difference of each capacitor is analyzed and presented. Based on the equivalent circuit model analysis of the proposed system, the EMF and PTE characteristics of the WPT system depending on the design variables are comprehensively analyzed. The proposed system is compared with conventional systems through simulation and measurements. It is verified that the proposed system can reduce the EMF by 41.05% and increase the PTE by 9.62% compared to the conventional system. In addition, through simulation, human exposure to EMFs is assessed considering the exposure environment and electrical properties of human tissues. As a result, the current density, induced electric field, and specific absorption rate were reduced by 44.10%, 38.90%, and 63.82%, respectively.


Subject(s)
Electric Power Supplies , Electromagnetic Fields , Humans , Wireless Technology , Prostheses and Implants , Electricity
2.
Sensors (Basel) ; 21(23)2021 Dec 06.
Article in English | MEDLINE | ID: mdl-34884150

ABSTRACT

In this paper, we propose a method of wirelessly torque transfer (WTT) and power (WPT) to a drug pump, one of implantable medical devices. By using the magnetic field generated by the WPT system to transfer torque and power to the receiving coil at the same time, applications that previously used power from the battery can be operated without a battery. The proposed method uses a receiving coil with magnetic material as a motor, and can generate torque in a desired direction using the magnetic field from the transmitting coil. The WPT system was analyzed using a topology that generates a constant current for stable torque generation. In addition, a method for detecting the position of the receiving coil without using additional power was proposed. Through simulations and experiments, it was confirmed that WTT and WPT were possible at the same time, and in particular, it was confirmed that WTT was stably possible.


Subject(s)
Pharmaceutical Preparations , Wireless Technology , Electric Power Supplies , Prostheses and Implants , Torque
3.
Article in English | MEDLINE | ID: mdl-35010303

ABSTRACT

The concept of a coupling factor was introduced in International Electrotechnical Commission (IEC) 62311 and 62233 to provide a product safety assessment that considers the localized exposure when an electromagnetic field (EMF) source is close to the human body. To calculate the coupling factors between the human body and EMF source, a numerical calculation should be carried out to calculate the internal quantities of the human body models. However, at frequencies below 10 MHz, the computed current density or internal electric field has computational artifacts from segmentation or discretization errors. Specifically, coupling factors are calculated based on the maximum values, which may include computational artifacts due to abnormal peaks. In this study, we propose an improved calculation method to remove computational artifacts by applying the 99.99th percentile in calculating the coupling factors without underestimation. The performance of the proposed method is verified through a comparison based on various human body models with wireless power transfer (WPT) systems and compliance with the reference levels and basic restrictions. The results indicate that the proposed method can provide uniform coupling factors by reducing the computational errors by up to 65.3% compared to a conventional method.


Subject(s)
Electromagnetic Fields , Wireless Technology , Electricity , Humans
4.
Radiat Prot Dosimetry ; 189(1): 13-27, 2020 Jul 07.
Article in English | MEDLINE | ID: mdl-32090242

ABSTRACT

Recently, a wireless charging system (WCS) for drones has been extensively studied, although standards for compliance testing of a WCS for drones have yet to be established. In this study, we propose methods for human exposure assessments of a WCS for drones by comprehensively considering the various positions of the system and the postures of human body models. The electromagnetic fields from a WCS are modeled and the internal quantities of the human body models, consisting of current density, internal electric field and specific absorption rate, are calculated. The incident fields around the WCS and the internal quantities are analyzed at 140 kHz, which is the operating frequency of the WCS applied. Results of an exposure assessment based on the confirmed worst-case scenario are presented. In addition, the internal quantities depending on the human body models and the material characteristics of the simplified models are also discussed using four different anatomical and simplified human body models.


Subject(s)
Electromagnetic Fields , Human Body , Electricity , Humans , Posture