Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters











Database
Language
Publication year range
1.
J Contemp Brachytherapy ; 9(6): 519-526, 2017 Dec.
Article in English | MEDLINE | ID: mdl-29441095

ABSTRACT

PURPOSE: There are no reports on pre-insertion identification of cervix cancer patients at risk for uterine perforation during brachytherapy (BT). Our aim was to assess the incidence of risk factors in our patient cohort, and assess feasibility of a novel technique of magnetic resonance imaging (MRI)-guided navigation for applicator insertion (NAI) in high-risk cases. MATERIAL AND METHODS: All patients with locally advanced cervical cancer, treated with image guided adaptive BT at our department between October 2013 and June 2017 were considered for analysis. Tumor characteristics on initial MRI (MRIinitial), pre-BT MRI (MRIpre-BT), and BT MRI (MRIBT) were assessed. Frequency of risk factors (age above 60 years, retroverted/retroflected uterus, tumor necrosis, non-visible cervical orifice, distorted cervical canal) was recorded. Patients with two or more factors underwent MRI guided NAI. Time needed for NAI was estimated and procedure feasibility score assigned using a three-tiered scoring system. RESULTS: Twenty-seven patients (98 insertions) were included. Mean tumor volume was 70.2 (± 47.9), 17.8 (± 18.9), and 10.3 (± 9.1) cm3 on MRIinitial, MRIpre-BT, and MRIBT1, respectively (p < 0.05). In 16 (59%) cases, ≥ 1 perforation risk factor was found on MRIpre-BT: distorted canal in 12 (44%), necrosis in 9 (33%), retroverted/retroflected uterus in 8 (30%) cases. Nine (33%) patients had ≥ 2 risk factors and underwent MRI guided NAI. Additional time to perform NAI was estimated at 105 minutes, and feasibility score was 1 in all cases. There were no cases of uterine perforation. CONCLUSIONS: Using pre-insertion MRI, we found ≥ 2 risk factors for uterine perforation in 1/3 of patients. Off-line MRI navigation was feasible and enabled non-complicated insertion in all cases. Further studies with larger sample size are warranted to assess its clinical efficacy.

2.
Radiol Oncol ; 48(3): 293-300, 2014 Sep.
Article in English | MEDLINE | ID: mdl-25177244

ABSTRACT

BACKGROUND: Optimal applicator insertion is a precondition for the success of cervix cancer brachytherapy (BT). We aimed to assess feasibility and efficacy of MRI-assisted pre-planning, based on applicator insertion in para-cervical anaesthesia (PCA). PATIENTS AND METHODS: Five days prior to BT, the pre-planning procedure was performed in 18 cervix cancer patients: tandem-ring applicator was inserted under PCA, pelvic MRI obtained and applicator removed. Procedure tolerability was assessed. High risk clinical target volume (HR CTV) and organs at risk were delineated on the pre-planning MRI, virtual needles placed at optimal positions, and dose planning performed. At BT, insertion was carried out in subarachnoidal anaesthesia according to pre-planned geometry. Pre-planned and actual treatment parameters were compared. RESULTS: Pre-planning procedure was well tolerated. Median difference between the pre-planned and actual needle insertion depth and position were 2 (0-10) mm and 4 (0-30) degrees, respectively. The differences between the pre-planned and actual geometric and dosimetric parameters were statistically non-significant. All actual needles were positioned inside the HR CTV and outside the organs at risk (OAR). CONCLUSIONS: Our pre-planning approach is well tolerated and effective. Pre-planned geometry and dose distribution can be reproduced at BT.

SELECTION OF CITATIONS
SEARCH DETAIL