Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
J Vis Exp ; (194)2023 04 14.
Article in English | MEDLINE | ID: mdl-37125805

ABSTRACT

One of the main key aspects in ensuring that a transplant evolves correctly is the sterility of the medium. Decellularized tracheal transplantation involves implanting an organ that was originally in contact with the environment, thus not being sterile from the outset. While the decellularization protocol (through detergent exposition [2% sodium dodecyl sulfate], continuous stirring, and osmotic shocks) is conducted in line with aseptic measures, it does not provide sterilization. Therefore, one of the main challenges is ensuring sterility prior to in vivo implantation. Although there are established gamma radiation sterilization protocols for inorganic materials, there are no such measures for organic materials. Additionally, the protocols in place for inorganic materials cannot be applied to organic materials, as the established radiation dose (25 kGy) would completely destroy the implant. This paper studies the effect of an escalated radiation dose in a decellularized rabbit trachea. We maintained the dose range (kGy) and tested escalated doses until finding the minimal dose at which sterilization is achieved. After determining the dose, we studied effects of it on the organ, both histologically and biomechanically. We determined that while 0.5 kGy did not achieve sterility, doses of both 1 kGy and 2 kGy did, with 1 kGy, therefore, being the minimal dose necessary to achieve sterilization. Microscopic studies showed no relevant changes compared to non-sterilized organs. Axial biomechanical characteristics were not altered at all, and only a slight reduction in the force per unit of length that the organ can radially tolerate was observed. We can therefore conclude that 1 kGy achieves complete sterilization of decellularized rabbit trachea with a minimal, if any, effects on the organ.


Subject(s)
Mechanical Phenomena , Trachea , Animals , Rabbits , Gamma Rays , Transplantation, Homologous/methods , Sterilization/methods
2.
Metabolism ; 57(9): 1232-40, 2008 Sep.
Article in English | MEDLINE | ID: mdl-18702949

ABSTRACT

The metabolic syndrome (MS) is defined by the clustering of a number of cardiovascular risk factors. The aims of the present study were to estimate the prevalence of MS in Madrid (Spain) by 2 definitions and to investigate its relationship with several sociodemographic factors and C-reactive protein (CRP) levels. This was a cross-sectional population study, and participants were 1344 subjects aged 31 to 70 years. Clinical evaluation included data on sociodemographic and cardiovascular background, physical examination, fasting glucose, triglycerides, and high-density lipoprotein cholesterol. The CRP levels were determined in a subgroup of 843 subjects. The diagnosis of MS was made according to the 2005 Adult Treatment Panel III (ATP III) and International Diabetes Federation (IDF) definitions. The age- and sex-adjusted prevalence of MS was 24.6% (95% confidence interval [CI], 22.3%-26.9%) using the ATP III definition and 30.9% (95% CI, 28.4%-33.3%) using the International Diabetes Federation definition. The overall agreement rate was 91.5% (kappa = 0.80; 95% CI, 0.76-0.83). Prevalence figures by both definitions were higher in men than in women and increased with age. Male sex, older age, low educational level, and physical inactivity were all determinants of ATP III-defined MS. The presence of MS or any of its components was associated with high CRP levels. In a logistic regression analysis, low educational level and waist circumference were the best predictors for high CRP level. The prevalence of MS in the Madrid region is one of the highest in Europe and confirms the strong Spanish regional variability in this syndrome frequency. Some sociodemographic and lifestyle factors, particularly educational level, are predictors for MS and high CRP levels.


Subject(s)
C-Reactive Protein/metabolism , Metabolic Syndrome/blood , Metabolic Syndrome/epidemiology , Adult , Age Distribution , Aged , Anthropometry , Cross-Sectional Studies , Demography , Educational Status , Female , Humans , Life Style , Logistic Models , Male , Metabolic Syndrome/complications , Middle Aged , Motor Activity , Predictive Value of Tests , Prevalence , Risk Factors , Sex Distribution , Spain/epidemiology
3.
Blood Press Monit ; 11(4): 207-13, 2006 Aug.
Article in English | MEDLINE | ID: mdl-16810031

ABSTRACT

OBJECTIVES: (1) To assess whether home blood pressure measurement is a reliable alternative to ambulatory blood pressure monitoring for the evaluation of treated patients with inadequate blood pressure control at the clinic; and (2) to evaluate the relationship between home blood pressure and several target-organ damage markers. BASIC METHODS: A cross-sectional study was performed in 225 treated hypertensive patients with persistently high blood pressure values at the clinic (systolic blood pressure 140 mmHg and/or diastolic blood pressure 90 mmHg). All study participants underwent clinic blood pressure measurement, 24-h ambulatory blood pressure and home blood pressure monitoring. A subgroup of patients underwent the following procedures: carotid echography (n=74), microalbuminuria determination (n=88) and echocardiography (n=43). We defined out-of-clinic normotension as an average ambulatory or home blood pressure less than 135 mmHg (systolic) and 85 mmHg (diastolic). MAIN RESULTS: The sensitivity, specificity and positive and negative predictive values of the home blood pressure method for predicting out-of-clinic normotension (with the ambulatory method used as reference), expressed as percentages, were 50, 87, 64 and 79%, respectively. Systolic home blood pressure correlated significantly with left ventricular mass (r=0.33, P<0.05) and microalbuminuria (r=0.24, P<0.05). Similar correlation coefficients were found for systolic ambulatory blood pressure (r=0.32, P<0.05 and r=0.24, P<0.05, respectively). Clinic blood pressure did not correlate with either left ventricular mass or microalbuminuria (r=0.19, P=0.09 and r=0.19, P=0.24, respectively). Diastolic home blood pressure, but not ambulatory blood pressure, correlated negatively with mean carotid intima-media thickness (r=-0.27, P<0.05). CONCLUSION: Our results suggest that, in patients with poorly controlled hypertension at the clinic, home blood pressure represents a complementary test rather than an alternative to ambulatory blood pressure, and correlates with several target-organ damage markers.


Subject(s)
Blood Pressure Monitoring, Ambulatory/methods , Hypertension/physiopathology , Aged , Albuminuria/etiology , Carotid Arteries/diagnostic imaging , Carotid Arteries/pathology , Cross-Sectional Studies , Echocardiography , Female , Heart Ventricles/pathology , Humans , Hypertension/complications , Hypertension/pathology , Male , Middle Aged , Predictive Value of Tests , Sensitivity and Specificity
4.
Am J Hypertens ; 16(7): 556-63, 2003 Jul.
Article in English | MEDLINE | ID: mdl-12850389

ABSTRACT

BACKGROUND: Left ventricular hypertrophy (LVH) is an important predictor of cardiovascular risk, and its detection contributes to risk stratification. The aims of the present study were to estimate the prevalence of echocardiographic LVH and to evaluate the influence of echocardiography (ECHO) on cardiovascular risk stratification in hypertensive patients presenting in primary care. METHODS: In this cross-sectional study, 250 patients recently diagnosed with mild hypertension underwent clinical evaluation including electrocardiography (ECG), microalbuminuria measurement, 24-h blood pressure monitoring and ECHO. Level of cardiovascular risk was stratified, initially using routine procedures including ECG to assess target organ damage and then again after detection of LVH by ECHO. RESULTS: The frequency of echocardiographic LVH was 32%, substantially higher than that detected by ECG (9%). Initial cardiovascular risk stratification yielded the following results: 30% low risk, 49% medium risk, 16% high risk, and 5% very high risk subjects. The detection of LVH by ECHO provoked a significant change in the risk strata distribution, particularly in those patients initially classified as being at medium risk. In this group, 40% of subjects were reclassified as high risk subjects according to ECHO information. The new classification was as follows: 23% low risk, 30% medium risk, 42% high risk, and 5% very high risk subjects. CONCLUSIONS: A substantial proportion of mildly hypertensive patients presenting in primary care have LVH determined by ECHO. Our results suggest that this procedure could significantly improve cardiovascular risk stratification in those patients with multiple risk factors, but no evidence of target organ damage by routine investigations.


Subject(s)
Hypertension/complications , Hypertrophy, Left Ventricular/epidemiology , Albuminuria , Blood Pressure Monitoring, Ambulatory , Cross-Sectional Studies , Echocardiography , Female , Humans , Hypertrophy, Left Ventricular/diagnosis , Hypertrophy, Left Ventricular/diagnostic imaging , Hypertrophy, Left Ventricular/etiology , Male , Middle Aged , Physical Examination , Prevalence , Primary Health Care , Risk Assessment
SELECTION OF CITATIONS
SEARCH DETAIL
...