1.
JAMA Cardiol ; 2024 Sep 25.
Article in English | MEDLINE | ID: mdl-39320884

ABSTRACT

Importance: The ability to predict sudden cardiac death (SCD) in children and adolescents with hypertrophic cardiomyopathy (HCM) is currently inadequate. Late gadolinium enhancement (LGE) by cardiovascular magnetic resonance (CMR) imaging is associated with SCD events in adults with HCM. Objective: To examine the prognostic significance of LGE in patients with HCM who are younger than 21 years. Design, Setting, and Participants: This multicenter, retrospective cohort study was conducted from April 8, 2015, to September 12, 2022, in patients with HCM who were younger than 21 years and had undergone CMR imaging across multiple sites in the US, Europe, and South America. Observers of CMR studies were masked toward outcomes and demographic characteristics. Exposure: Natural history of HCM. Main Outcome and Measures: The primary outcome was SCD and surrogate events, including resuscitated cardiac arrest and appropriate discharges from an implantable defibrillator. Continuous and categorical data are expressed as mean (SD), median (IQR), or number (percentage), respectively. Survivor curves comparing patients with and without LGE were constructed by the Kaplan-Meier method, and likelihood of subsequent clinical events was further evaluated using univariate and multivariable Cox proportional hazards models. Results: Among 700 patients from 37 international centers, median (IQR) age was 14.8 (11.9-17.4) years, and 518 participants (74.0%) were male. During a median (IQR) [range] follow-up period of 1.9 (0.5-4.1) [0.1-14.8] years, 35 patients (5.0%) experienced SCD or equivalent events. LGE was present in 230 patients (32.9%), which constituted an mean (SD) burden of 5.9% (7.3%) of left ventricular myocardium. The LGE amount was higher in older patients and those with greater left ventricular mass and maximal wall thickness; patients with LGE had lower left ventricular ejection fractions and larger left atrial diameters. The presence and burden of LGE was associated with SCD, even after correcting for existing risk stratification tools. Patients with 10% or more LGE, relative to total myocardium, had a higher risk of SCD (unadjusted hazard ratio [HR], 2.19; 95% CI, 1.59-3.02; P < .001). Furthermore, the addition of LGE burden improved the performance of the HCM Risk-Kids score (before LGE addition: 0.66; 95% CI, 0.58-0.75; after LGE addition: 0.73; 95% CI, 0.66-0.81) and Precision Medicine in Cardiomyopathy score (before LGE addition: 0.68; 95% CI, 0.49-0.77; after LGE addition: 0.73; 95% CI, 0.64-0.82) SCD predictive models. Conclusions and Relevance: In this retrospective cohort study, quantitative LGE was a risk factor for SCD in patients younger than 21 years with HCM and improved risk stratification.

3.
Article in English | MEDLINE | ID: mdl-39245256

ABSTRACT

BACKGROUND: Shoulder proprioception, in which the anterior glenohumeral capsule plays a major role, is critical to the functioning of the shoulder. Consequently, most surgeons either do not resect or reinsert the anterior capsule in shoulder stabilization surgery. In the original Open Latarjet Procedure (OLP), the anterior capsule is preserved. However, in the all-Arthroscopic Latarjet Procedure (ALP), complete anterior capsule resection is recommended for better view and access to the coracoid. This raises the question if there is a postoperative difference in proprioception between these two procedures. Therefore, the aims of this study are (1) to assess the difference in postoperative proprioception between the operated and healthy sides after the OLP and ALP, and (2) to compare the difference in postoperative proprioception on the operated side between the OLP and ALP. METHODS: We conducted a retrospective analysis including all patients who underwent a proprioception test after an OLP or ALP at our center. Collected baseline characteristics included sex, age at surgery, operated side, hand dominance, presence of a Hill-sachs lesion, and time between surgery and the proprioception test. For the test, patients were positioned 1 meter from a wall. They were blindfolded and had to point at a target with a laser pointer taped to their index finger. The laser point was marked and the errors were measured horizontally and vertically and categorized as < 4 centimeters, 4-8 centimeters, 8-16 centimeters, and >16 centimeters. RESULTS: Between April 2022 and April 2024, 91 cases were identified, of which 24 underwent an OLP and 67 underwent an ALP. No significant difference was found in error distribution between the healthy and operated side after both the OLP (p = 0.30 horizontally, p = 0.67 vertically) and ALP (p = 0.20 horizontally, p = 0.34 vertically). Moreover, there was no significant difference in error distribution between the operated sides after the OLP versus ALP (p= 0.52 horizontally, p = 0.61 vertically). CONCLUSION: Our data suggests that postoperative proprioception is not significantly different between the operated and healthy sides after both the OLP and ALP, nor between the operated sides after the OLP versus after the ALP. This might imply that completely resecting the anterior glenohumeral capsule does not have a detrimental effect on shoulder proprioception. However, these results are multifactorial and prospective studies are needed to better understand the regeneration potential of glenohumeral capsule mechanoreceptors and the importance of the anterior capsule for shoulder proprioception.

4.
J Pediatr ; 275: 114223, 2024 Aug 02.
Article in English | MEDLINE | ID: mdl-39097263

ABSTRACT

OBJECTIVE: To determine whether it is the magnitude of early postnatal catch-up growth (CUG) in response to fetal growth restriction (FGR) or the FGR itself that negatively impacts cognitive outcome in a model of monochorionic twins discordant for fetal growth. STUDY DESIGN: This analysis is part of the LEMON study, a cohort study including all monochorionic twins with selective FGR aged 3 through 17 years. Growth measurements as documented by our primary care system were collected retrospectively. An age-appropriate neurodevelopmental test was performed generating a full-scale IQ (FSIQ). CUG at 2 years was calculated as (weight [kg] at 2 years-birth weight [kg]). We used a multivariable regression model investigating the association between FSIQ (outcome) and birth weight zscore, gestational age at birth and CUG at 2 years (predictors). Generalized estimating equations accounted for the fact that observations between cotwins are not independent. RESULTS: Median age at follow-up of the 46 included twin pairs was 11 (IQR 8-13) years. Birth weight z score and gestational age at birth were significantly associated with FSIQ, with ß-coefficients of 5.897 (95% CI 3.382-8.411), and 2.589 (95% CI 1.227-3.951), respectively (P < .0001). Adjusted for birth weight z score and gestational age, CUG in the first 2 years after birth was not significantly associated with FSIQ (ß-coefficient 0.108 [95% CI -1.373 to 1.590], P = .886). CONCLUSIONS: Our results, combining detailed growth measurements and neurodevelopmental follow-up in a discordant identical twin model, demonstrate that FGR itself rather than early postnatal CUG has negative consequences for cognitive development.

5.
Int J Obes (Lond) ; 2024 Aug 06.
Article in English | MEDLINE | ID: mdl-39107494

ABSTRACT

BACKGROUND: Overweight and obesity are among the main causes of cardiovascular diseases. Exercise testing can aid in the early detection of subtle cardiac dysfunction not present in rest. We hypothesized that the cardiovascular response to exercise is impaired among children with overweight or obesity, characterized by the inability of the cardiovascular system to adapt to exercise by increasing cardiac volumes and blood pressure. We performed a cardiovascular stress test to investigate whether the cardiovascular exercise response is altered in children with overweight and obesity, as compared to children with a normal weight. SUBJECTS: A subgroup of the Generation R population-based prospective cohort study, consisting of 41 children with overweight or obesity and 166 children with a normal weight with a mean age of 16 years, performed an isometric exercise. METHODS: Continuous heart rate and blood pressure were measured during rest, exercise and recovery. Cardiovascular magnetic resonance (CMR) measurements were performed during rest and exercise. RESULTS: Higher BMI was associated with a higher resting systolic and diastolic blood pressure (difference: 0.24 SDS (95% CI 0.10, 0.37) and 0.20 SDS (95% CI 0.06, 0.33)) and lower systolic and diastolic blood pressure increases from rest to peak exercise (-0.11 SDS (95% CI -0.20, -0.03) and -0.07 SDS (95% CI -0.07, -0.01)). BMI was also associated with a slower decrease in systolic and diastolic blood pressure during recovery (p values < 0.05). Higher childhood BMI was associated with lower BSA corrected left ventricular mass, end-diastolic volume and stroke volume (p values < 0.05). There were no associations of childhood BMI with the cardiac response to exercise measured by heart rate and CMR measurements. CONCLUSION: Childhood BMI is, across the full range, associated with a blunted blood pressure response to static exercise but there were no differences in cardiac response to exercise. Our findings suggest that adiposity may especially affect the vascular exercise reaction without affecting cardiac response.

6.
Open Heart ; 11(1)2024 May 08.
Article in English | MEDLINE | ID: mdl-38719498

ABSTRACT

BACKGROUND: Despite maximal treatment, heart failure (HF) remains a major clinical challenge. Besides neurohormonal overactivation, myocardial energy homoeostasis is also impaired in HF. Trimetazidine has the potential to restore myocardial energy status by inhibiting fatty acid oxidation, concomitantly enhancing glucose oxidation. Trimetazidine is an interesting adjunct treatment, for it is safe, easy to use and comes at a low cost. OBJECTIVE: We conducted a systematic review to evaluate all available clinical evidence on trimetazidine in HF. We searched Medline/PubMed, Embase, Cochrane CENTRAL and ClinicalTrials.gov to identify relevant studies. METHODS: Out of 213 records, we included 28 studies in the meta-analysis (containing 2552 unique patients), which almost exclusively randomised patients with HF with reduced ejection fraction (HFrEF). The studies were relatively small (median study size: N=58) and of short duration (mean follow-up: 6 months), with the majority (68%) being open label. RESULTS: Trimetazidine in HFrEF was found to significantly reduce cardiovascular mortality (OR 0.33, 95% CI 0.21 to 0.53) and HF hospitalisations (OR 0.42, 95% CI 0.29 to 0.60). In addition, trimetazidine improved (New York Heart Association) functional class (mean difference: -0.44 (95% CI -0.49 to -0.39), 6 min walk distance (mean difference: +109 m (95% CI 105 to 114 m) and quality of life (standardised mean difference: +0.52 (95% CI 0.32 to 0.71). A similar pattern of effects was observed for both ischaemic and non-ischaemic cardiomyopathy. CONCLUSIONS: Current evidence supports the potential role of trimetazidine in HFrEF, but this is based on multiple smaller trials of varying quality in study design. We recommend a large pragmatic randomised clinical trial to establish the definitive role of trimetazidine in the management of HFrEF.


Subject(s)
Heart Failure , Trimetazidine , Vasodilator Agents , Female , Humans , Heart Failure/drug therapy , Heart Failure/physiopathology , Stroke Volume/physiology , Stroke Volume/drug effects , Treatment Outcome , Trimetazidine/therapeutic use , Trimetazidine/pharmacology , Vasodilator Agents/therapeutic use , Ventricular Function, Left/drug effects , Ventricular Function, Left/physiology
7.
Eur Heart J Case Rep ; 8(4): ytae153, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38645675

ABSTRACT

Background: We present a case of a pregnant patient with recurrent angina, in which her symptoms were initially attributed to coronary artery spasm. However, during follow-up, she was diagnosed as having pheochromocytoma, a rare neuroendocrine tumour. Case summary: The 35-year-old patient was admitted to the hospital because of chest pain and elevated cardiac troponins after the use of MDMA. Physical examination, electrocardiogram, echocardiography, coronary angiogram, and cardiac MRI were normal. Symptoms were attributed to coronary spasm, and a calcium antagonist was started. Ten months later, when 36 weeks pregnant, her symptoms returned. One week later, the patient was readmitted to the hospital with signs of acute left ventricular (LV) failure, highly elevated troponins, and severe global LV dysfunction. Urgent section caesarean was performed due to maternal morbidity and foetal tachycardia. During section, flushes and marked variability in blood pressure were noted. Laboratory metanephrines testing was performed. LV function recovered within 3 days without any therapeutic intervention. However, chest pain reoccurred, now accompanied with headaches, malignant hypertension, and accelerated idiopathic ventricular rhythms. (Nor)metanephrines tests were positive. A solid lesion in the right adrenal on CT scan confirmed the diagnosis of pheochromocytoma. Fluid repletion and alpha-blocker therapy were started. Due to persistent symptoms, urgent laparoscopic adrenalectomy was performed. Hereafter, the patient remained without symptoms. Discussion: A pheochromocytoma may present with recurrent angina and can result in a catecholamine-induced cardiomyopathy. It is important to timely recognize this diagnosis in order to minimize morbidity and mortality.

8.
EClinicalMedicine ; 72: 102600, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38633574

ABSTRACT

Background: Fetal growth restriction (FGR) can negatively affect lung development, leading to increased respiratory morbidity and reduced lung function later in life. Studies regarding the impact of FGR on lung function in singletons are influenced by genetic, obstetric, and maternal factors. To overcome these confounding factors, we aim to investigate lung function in identical twins with selective FGR (sFGR). Methods: Lung function assessments were performed in identical twins with sFGR born in our centre between March 1, 2002, and December 31, 2017, aged between 5 and 17 years. sFGR was defined as birthweight discordance ≥20%. Outcome measures consisted of forced expiratory volume in 1 s (FEV1), forced vital capacity (FVC), and transfer factor for carbon monoxide (DLCO) and were compared between the smaller and larger twin. Findings: Thirty-nine twin pairs performed spirometry of sufficient quality. Median gestational age at birth was 34.3 (interquartile range (IQR) 32.1-36.0) weeks with median birthweights of 1500 (IQR 1160-1880) grams and 2178 (IQR 1675-2720) grams for the smaller and larger twin, respectively. Smaller twins had significantly lower z-scores for FEV1 (-0.94 versus -0.41, p = 0.0015), FVC (-0.56 versus -0.06, p < 0.0001) and DLCO (-0.50 versus 0.00, p < 0.0001) compared to larger co-twins. Interpretation: Although being genetically identical, sFGR in identical twins is associated with a reduction in static and dynamic lung volume and a reduction in lung diffusion, even when taking the reduced lung volume into account. This indicates that adverse growth conditions in utero negatively affect lung development and function, potentially contributing to an increase in respiratory morbidities later in life. Funding: The Dutch Heart Foundation and The Bontius Foundation.

9.
J Orthop Traumatol ; 25(1): 20, 2024 Apr 18.
Article in English | MEDLINE | ID: mdl-38637350

ABSTRACT

BACKGROUND: This study aims to compare the range of motion (ROM) of reverse shoulder arthroplasty lateralised by bony increased offset (BIO-RSA) using a standard 38-mm (mm) component to regular reverse shoulder arthroplasty (RSA) lateralised by using a 42-mm glenoid component. The secondary aims are to compare patient-reported and radiographic outcomes between the two groups. MATERIALS AND METHODS: All patients with a BIO-RSA and size 38 glenosphere were retrospectively identified and matched to patients with a regular RSA and size 42 glenosphere. Matched patients were invited for a follow-up visit. ROM was assessed as well as radiographic outcomes (lateralisation, distalisation, inferior overhang, scapular notching, heterotopic bone formation, radiolucency, stress shielding, bone graft healing and viability and complications) and patient-reported outcomes (subjective shoulder value, Constant score, American Shoulder and Elbow Surgeons, activities of daily living which require internal rotation, activities of daily living which require external rotation and a visual analogue scale for pain). Outcomes were compared between the two groups. RESULTS: In total, 38 BIO-RSAs with a size 38 glenosphere were matched to 38 regular RSAs with a size 42 glenosphere. Of the 76 matched patients, 74 could be contacted and 70 (95%) were included. At the final follow-up, there were no differences between the two groups in ROM, patient-reported outcomes or radiographic outcomes (p > 0.485). CONCLUSIONS: Using a larger glenosphere is a feasible alternative to BIO-RSA for lateralising RSA, providing comparable ROM, patient-reported and radiographic results, while potentially decreasing costs, operative time and complication rates.


Subject(s)
Arthroplasty, Replacement, Shoulder , Shoulder Joint , Humans , Arthroplasty, Replacement, Shoulder/methods , Shoulder Joint/diagnostic imaging , Shoulder Joint/surgery , Retrospective Studies , Activities of Daily Living , Scapula/diagnostic imaging , Scapula/surgery , Range of Motion, Articular , Treatment Outcome
10.
J Magn Reson Imaging ; 2024 Apr 01.
Article in English | MEDLINE | ID: mdl-38558490

ABSTRACT

BACKGROUND: Automated 4D flow MRI valvular flow quantification without time-consuming manual segmentation might improve workflow. PURPOSE: Compare automated valve segmentation (AS) to manual (MS), and manually corrected automated segmentation (AMS), in corrected atrioventricular septum defect (c-AVSD) patients and healthy volunteers, for assessing net forward volume (NFV) and regurgitation fraction (RF). STUDY TYPE: Retrospective. POPULATION: 27 c-AVSD patients (median, 23 years; interquartile range, 16-31 years) and 24 healthy volunteers (25 years; 12.5-36.5 years). FIELD STRENGTH/SEQUENCE: Whole-heart 4D flow MRI and cine steady-state free precession at 3T. ASSESSMENT: After automatic valve tracking, valve annuli were segmented on time-resolved reformatted trans-valvular velocity images by AS, MS, and AMS. NFV was calculated for all valves, and RF for right and left atrioventricular valves (RAVV and LAVV). NFV variation (standard deviation divided by mean NFV) and NFV differences (NFV difference of a valve vs. mean NFV of other valves) expressed internal NFV consistency. STATISTICAL TESTS: Comparisons between methods were assessed by Wilcoxon signed-rank tests, and intra/interobserver variability by intraclass correlation coefficients (ICCs). P < 0.05 was considered statistically significant, with multiple testing correction. RESULTS: AMS mean analysis time was significantly shorter compared with MS (5.3 ± 1.6 minutes vs. 9.1 ± 2.5 minutes). MS NFV variation (6.0%) was significantly smaller compared with AMS (6.3%), and AS (8.2%). Median NFV difference of RAVV, LAVV, PV, and AoV between segmentation methods ranged from -0.7-1.0 mL, -0.5-2.8 mL, -1.1-3.6 mL, and - 3.1--2.1 mL, respectively. Median RAVV and LAVV RF, between 7.1%-7.5% and 3.8%-4.3%, respectively, were not significantly different between methods. Intraobserver/interobserver agreement for AMS and MS was strong-to-excellent for NFV and RF (ICC ≥0.88). DATA CONCLUSION: MS demonstrates strongest internal consistency, followed closely by AMS, and AS. Automated segmentation, with or without manual correction, can be considered for 4D flow MRI valvular flow quantification. LEVEL OF EVIDENCE: 3 TECHNICAL EFFICACY: Stage 3.

11.
J Orthop Traumatol ; 25(1): 10, 2024 Feb 28.
Article in English | MEDLINE | ID: mdl-38418742

ABSTRACT

BACKGROUND: The aim of this study was to use the Activities of Daily Living which require Internal Rotation (ADLIR) questionnaire to assess the functional internal rotation in patients who had undergone reverse shoulder arthroplasty (RSA) without reattachment of the subscapularis (SSc) tendon at a minimum follow-up of 2 years. The secondary aim was to report the objective range of motion (ROM) and the rate of postoperative instability. MATERIALS AND METHODS: All consecutive primary RSA procedures without reattachment of the SSc tendon that were performed using a Delta Xtend prosthesis (an inlay system with a 155° neck-shaft angle) between January 2015 and December 2020 were identified to ensure a minimum follow-up of 2 years. Patients were contacted and requested to fill in several questionnaires, including the ADLIR and Auto-Constant scores. RESULTS: In total, 210 patients met the inclusion criteria; among those patients, 187 could be contacted and 151 completed questionnaires (response rate: 81%). The SSc tendon was fully detached without repair in all cases, and a superolateral approach was used in 130 (86%) cases. The median follow-up was 4.5 years (range: 2.0-7.6). At final follow-up, the mean ADLIR score was 88/100 (interquartile range (IQR): 81-96). The median level reached in internal rotation was the 3rd lumbar vertebra (IQR: lumbosacral region-12th thoracic vertebra). Of the 210 eligible patients, one required a revision for a dislocation within the first month after primary surgery. With regards to regression analysis with ADLIR score as the outcome, none of the factors were associated with the ADLIR score, although age and smoking approached significance (0.0677 and 0.0594, respectively). None of the explanatory variables were associated with ROM in internal rotation (p > 0.05). CONCLUSIONS: This study demonstrates that satisfactory ADLIR scores and internal rotation ROM were obtained at mid-term follow-up after RSA leaving the SSc detached. Leaving the SSc detached also did not lead to high instability rates; only one out of 210 prostheses was revised for dislocation within the first month after primary surgery.


Subject(s)
Arthroplasty, Replacement, Shoulder , Shoulder Joint , Humans , Arthroplasty, Replacement, Shoulder/methods , Shoulder Joint/surgery , Rotator Cuff/surgery , Cohort Studies , Activities of Daily Living , Retrospective Studies , Prostheses and Implants , Range of Motion, Articular , Treatment Outcome
12.
J Am Heart Assoc ; 13(3): e033122, 2024 Feb 06.
Article in English | MEDLINE | ID: mdl-38293946

ABSTRACT

BACKGROUND: Kidney disease is the most important predictor of death in patients with a Fontan circulation, yet its clinical and hemodynamic correlates have not been well established. METHODS AND RESULTS: A total of 53 ambulatory patients with a Fontan circulation (median age, 16.2 years, 52.8% male patients) underwent advanced cardiovascular magnetic resonance assessment, including 4-dimensional flow imaging and computational fluid dynamics. Estimated glomerular filtration rate (eGFR) <90 mL/min per 1.73 m2 was observed in 20.8% and albumin-to-creatinine ratio >3 mg/mmol in 39.6%. The average eGFR decline rate was -1.83 mL/min per 1.73 m2 per year (95% CI, -2.67 to -0.99; P<0.001). Lower eGFR was associated with older age, larger body surface area at examination, longer time since Fontan procedure, and lower systemic ventricular ejection fraction. Higher albumin-to-creatinine ratio was associated with absence of fenestration at the Fontan operation, and older age and lower systemic ventricular ejection fraction at the assessment. Lower cross-sectional area of the Fontan conduit indexed to flow (r=0.32, P=0.038), higher inferior vena cava-conduit velocity mismatch factor (r=-0.35, P=0.022), higher kinetic energy indexed to flow in the total cavopulmonary connection (r=-0.59, P=0.005), and higher total cavopulmonary connection resistance (r=-0.42, P=0.005 at rest; r=-0.43, P=0.004 during exercise) were all associated with lower eGFR but not with albuminuria. CONCLUSIONS: Kidney dysfunction and albuminuria are common among clinically well adolescents and young adults with a Fontan circulation. Advanced cardiovascular magnetic resonance-derived metrics indicative of declining Fontan hemodynamics are associated with eGFR and might serve as targets to improve kidney health. Albuminuria might be driven by other factors that need further investigation.


Subject(s)
Fontan Procedure , Heart Defects, Congenital , Adolescent , Young Adult , Humans , Male , Female , Creatinine , Albuminuria/etiology , Heart Defects, Congenital/diagnostic imaging , Heart Defects, Congenital/surgery , Hemodynamics , Fontan Procedure/adverse effects , Fontan Procedure/methods , Kidney , Magnetic Resonance Spectroscopy , Albumins
13.
Article in English | MEDLINE | ID: mdl-37866752

ABSTRACT

BACKGROUND: The use of reverse shoulder arthroplasty (RSA) is becoming increasingly prevalent. However, few studies have been published reporting the long-term outcomes of RSA. This study aims to report the clinical, radiographic, and patient-reported outcomes of the Delta Xtend reverse shoulder prosthesis, performed by a single surgeon and with a minimum follow-up of 10 years. METHODS: All RSA procedures performed between 2005 and 2012 were identified. Patients were contacted and invited for a follow-up visit including clinical assessment, radiographs, and patient-reported outcome measures. Patients with a follow-up of less than 10 years were excluded. The revision-free implant survival was calculated at 10 years. Between 2005 and 2012, 119 procedures in 116 patients meeting inclusion criteria were identified. Of these patients, 35 were deceased before reaching the 10-year follow-up and 23 could not be reached. In total, 63 RSAs could be included in 61 patients (response rate: 75%). The median follow-up was 11.7 years (interquartile range [IQR]: 10.5-13.2). RESULTS: Of the 61 patients, 7 patients underwent a revision after a median of 3 years (IQR: 0.2-9.8) during the total follow-up period. The 10-year implant survival was 94% (95% confidence interval: 84-98). At final follow-up, the median anterior elevation was 135° (IQR: 130°-160°), the median abduction was 120° (IQR: 100°-135°), and the median level reached with internal rotation was L5 (IQR: sacrum-L5). The median Auto-Constant score was 68 (IQR: 53-78), the median Subjective Shoulder Value was 80 (IQR: 70-93), and the median pain score was 0.2/10 (IQR: 0-2). In total, radiographs could be obtained in 25 patients (40%). Scapular notching occurred in 10 patients (40%), which was classified as Sirveaux-Nerot grade IV in 3 patients (12%). Ossification occurred in 10 patients (40%), and stress shielding in 2 patients (8%). Radiolucencies were observed around the humeral component in 24 patients (96%) and around the glenoid component in 13 patients (52%). CONCLUSION: The long-term results of RSA with a Delta Xtend prosthesis are favorable, with long-term improvement in range of motion and patient-reported outcome measures, and a satisfactory implant survival rate. Interestingly, the radiographical analysis showed high prevalence of signs associated with loosening, which did not seem to translate to high complication rates or inferior results.

14.
Int J Cardiovasc Imaging ; 39(12): 2575-2587, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37801171

ABSTRACT

To examine feasibility and reproducibility and to evaluate the cardiovascular response to an isometric handgrip exercise in low-risk pediatric population using Cardiovascular Magnetic Resonance measurements. In a subgroup of 207 children with a mean age of 16 years participating in a population-based prospective cohort study, children performed an isometric handgrip exercise. During rest and exercise, continuous heart rate and blood pressure were measured. Cardiovascular magnetic resonance (CMR) measurements included left ventricular mass, aortic distensibility and pulse wave velocity at rest and left ventricular end-diastolic and end-systolic volumes, ejection fraction, stroke volume and cardiac output during rest and exercise. 207 children had successful CMR measurements in rest and 184 during exercise. We observed good reproducibility for all cardiac measurements. Heart rate increased with a mean ± standard deviation of 42.6% ± 20.0 and blood pressure with 6.4% ± 7.0, 5.4% ± 6.1 and 11.0% ± 8.3 for systolic, diastolic and mean arterial blood pressure respectively (p-values < 0.05). During exercise, left ventricular end-diastolic and end-systolic volumes and cardiac output increased, whereas left ventricular ejection fraction slightly decreased (p-values < 0.05). Stroke volume did not change significantly. A sustained handgrip exercise of 7 min at 30-40% maximal voluntary contraction is a feasible exercise-test during CMR in a healthy pediatric population, which leads to significant changes in heart rate, blood pressure and functional measurements of the left ventricle in response to exercise. This approach offers great novel opportunities to detect subtle differences in cardiovascular health.


Subject(s)
Pulse Wave Analysis , Ventricular Function, Left , Humans , Child , Adolescent , Stroke Volume/physiology , Ventricular Function, Left/physiology , Reproducibility of Results , Hand Strength , Cohort Studies , Prospective Studies , Predictive Value of Tests , Exercise/physiology
16.
Eur J Endocrinol ; 189(2): 183-189, 2023 Aug 02.
Article in English | MEDLINE | ID: mdl-37548178

ABSTRACT

OBJECTIVE: Research suggests that postnatal catch-up growth after fetal growth restriction (FGR) occurs frequently. Yet, postnatal growth in singletons may be influenced by multiple factors. Identical twins with discordant prenatal growth, termed selective FGR (sFGR), can be regarded as a natural experiment eliminating these sources of bias. DESIGN: Observational cohort study. METHODS: Monochorionic twins with sFGR born between 2002 and 2017 (aged 3-17 years) were eligible. Growth measurements (height, weight, head circumference, and body mass index) were performed at follow-up. Detailed growth curves documented by a systematic primary care system in the Netherlands were collected. Measurements were converted to standard deviation scores (SDSs). A mixed-effects model was used to assess within-pair SDS difference and individual height SDS relative to target height SDS. RESULTS: Forty-seven twin pairs (94 children) were included at a median age of 11 (interquartile range 8-13) years. At the last measurement, smaller twins at birth had a lower height SDS [-0.6 vs -0.3, P < .001, median difference 0.5 (95%CI 0.4-0.7)], lower weight SDS [-0.5 vs -0.1, P < .001, median difference 0.8 (95%CI 0.5-1.0)], and lower head circumference SDS [-0.5 vs 0.2, P < .001, median difference 0.8 (95%CI 0.6-0.9)] compared to larger twins. These differences persisted until the age of 17. Smaller twins showed rapid catch-up growth in the first 2 years and reached their target height range between 8 and 11 years. CONCLUSIONS: Identical twins with discordant prenatal growth maintain a modest but significant difference in height, weight, and head circumference, indicating a persistent, inhibitory effect of an adverse intrauterine environment on childhood growth.


Subject(s)
Fetal Growth Retardation , Twins, Monozygotic , Pregnancy , Infant, Newborn , Female , Child , Humans , Adolescent , Body Mass Index , Cohort Studies , Body Height , Birth Weight
17.
Bone Joint J ; 105-B(9): 1000-1006, 2023 Sep 01.
Article in English | MEDLINE | ID: mdl-37652454

ABSTRACT

Aims: The current evidence comparing the two most common approaches for reverse total shoulder arthroplasty (rTSA), the deltopectoral and anterosuperior approach, is limited. This study aims to compare the rate of loosening, instability, and implant survival between the two approaches for rTSA using data from the Dutch National Arthroplasty Registry with a minimum follow-up of five years. Methods: All patients in the registry who underwent a primary rTSA between January 2014 and December 2016 using an anterosuperior or deltopectoral approach were included, with a minimum follow-up of five years. Cox and logistic regression models were used to assess the association between the approach and the implant survival, instability, and glenoid loosening, independent of confounders. Results: In total, 3,902 rTSAs were included. A deltopectoral approach was used in 54% (2,099/3,902) and an anterosuperior approach in 46% (1,803/3,902). Overall, the mean age in the cohort was 75 years (50 to 96) and the most common indication for rTSA was cuff tear arthropathy (35%; n = 1,375), followed by osteoarthritis (29%; n = 1,126), acute fracture (13%; n = 517), post-traumatic sequelae (10%; n = 398), and an irreparable cuff rupture (5%; n = 199). The two high-volume centres performed the anterosuperior approach more often compared to the medium- and low-volume centres (p < 0.001). Of the 3,902 rTSAs, 187 were revised (5%), resulting in a five-year survival of 95.4% (95% confidence interval 94.7 to 96.0; 3,137 at risk). The most common reason for revision was a periprosthetic joint infection (35%; n = 65), followed by instability (25%; n = 46) and loosening (25%; n = 46). After correcting for relevant confounders, the revision rate for glenoid loosening, instability, and the overall implant survival did not differ significantly between the two approaches (p = 0.494, p = 0.826, and p = 0.101, respectively). Conclusion: The surgical approach used for rTSA did not influence the overall implant survival or the revision rate for instability or glenoid loosening.


Subject(s)
Arthritis, Infectious , Arthroplasty, Replacement, Shoulder , Osteoarthritis , Humans , Aged , Arthroplasty , Disease Progression
18.
ESC Heart Fail ; 10(5): 2998-3010, 2023 10.
Article in English | MEDLINE | ID: mdl-37530098

ABSTRACT

AIMS: Impaired myocardial energy homeostasis plays an import role in the pathophysiology of heart failure with preserved ejection fraction (HFpEF). Left ventricular relaxation has a high energy demand, and left ventricular diastolic dysfunction has been related to impaired energy homeostasis. This study investigated whether trimetazidine, a fatty acid oxidation inhibitor, could improve myocardial energy homeostasis and consequently improve exercise haemodynamics in patients with HFpEF. METHODS AND RESULTS: The DoPING-HFpEF trial was a phase II single-centre, double-blind, placebo-controlled, randomized cross-over trial. Patients were randomized to trimetazidine treatment or placebo for 3 months and switched after a 2-week wash-out period. The primary endpoint was change in pulmonary capillary wedge pressure, measured with right heart catheterization at multiple stages of bicycling exercise. Secondary endpoint was change in myocardial phosphocreatine/adenosine triphosphate, an index of the myocardial energy status, measured with phosphorus-31 magnetic resonance spectroscopy. The study included 25 patients (10/15 males/females; mean (standard deviation) age, 66 (10) years; body mass index, 29.8 (4.5) kg/m2 ); with the diagnosis of HFpEF confirmed with (exercise) right heart catheterization either before or during the trial. There was no effect of trimetazidine on the primary outcome pulmonary capillary wedge pressure at multiple levels of exercise (mean change 0 [95% confidence interval, 95% CI -2, 2] mmHg over multiple levels of exercise, P = 0.60). Myocardial phosphocreatine/adenosine triphosphate in the trimetazidine arm was similar to placebo (1.08 [0.76, 1.76] vs. 1.30 [0.95, 1.86], P = 0.08). There was no change by trimetazidine compared with placebo in the exploratory parameters: 6-min walking distance (mean change of -6 [95% CI -18, 7] m vs. -5 [95% CI -22, 22] m, respectively, P = 0.93), N-terminal pro-B-type natriuretic peptide (5 (-156, 166) ng/L vs. -13 (-172, 147) ng/L, P = 0.70), overall quality-of-life (KCCQ and EQ-5D-5L, P = 0.78 and P = 0.51, respectively), parameters for diastolic function measured with echocardiography and cardiac magnetic resonance, or metabolic parameters. CONCLUSIONS: Trimetazidine did not improve myocardial energy homeostasis and did not improve exercise haemodynamics in patients with HFpEF.


Subject(s)
Heart Failure , Trimetazidine , Humans , Male , Female , Aged , Trimetazidine/therapeutic use , Trimetazidine/pharmacology , Phosphocreatine/pharmacology , Phosphocreatine/therapeutic use , Cross-Over Studies , Stroke Volume , Adenosine Triphosphate/pharmacology , Adenosine Triphosphate/therapeutic use
19.
J Cardiovasc Magn Reson ; 25(1): 40, 2023 07 20.
Article in English | MEDLINE | ID: mdl-37474977

ABSTRACT

Hemodynamic assessment is an integral part of the diagnosis and management of cardiovascular disease. Four-dimensional cardiovascular magnetic resonance flow imaging (4D Flow CMR) allows comprehensive and accurate assessment of flow in a single acquisition. This consensus paper is an update from the 2015 '4D Flow CMR Consensus Statement'. We elaborate on 4D Flow CMR sequence options and imaging considerations. The document aims to assist centers starting out with 4D Flow CMR of the heart and great vessels with advice on acquisition parameters, post-processing workflows and integration into clinical practice. Furthermore, we define minimum quality assurance and validation standards for clinical centers. We also address the challenges faced in quality assurance and validation in the research setting. We also include a checklist for recommended publication standards, specifically for 4D Flow CMR. Finally, we discuss the current limitations and the future of 4D Flow CMR. This updated consensus paper will further facilitate widespread adoption of 4D Flow CMR in the clinical workflow across the globe and aid consistently high-quality publication standards.


Subject(s)
Cardiovascular System , Humans , Blood Flow Velocity , Predictive Value of Tests , Heart , Magnetic Resonance Imaging , Magnetic Resonance Spectroscopy
20.
Pediatr Cardiol ; 2023 Jul 24.
Article in English | MEDLINE | ID: mdl-37488239

ABSTRACT

Pulmonary artery (PA) stenosis is a common complication after the arterial switch operation (ASO) for transposition of the great arteries (TGA). Four-dimensional flow (4D flow) CMR provides the ability to quantify flow within an entire volume instead of a single plane. The aim of this study was to compare PA maximum velocities and stroke volumes between 4D flow CMR, two-dimensional phase-contrast (2D PCMR) and echocardiography. A prospective study including TGA patients after ASO was performed between December 2018 and October 2020. All patients underwent echocardiography and CMR, including 2D PCMR and 4D flow CMR. Maximum velocities and stroke volumes were measured in the main, right, and left PA (MPA, LPA, and RPA, respectively). A total of 39 patients aged 20 ± 8 years were included. Maximum velocities in the MPA, LPA, and RPA measured by 4D flow CMR were significantly higher compared to 2D PCMR (p < 0.001 for all). PA assessment by echocardiography was not possible in the majority of patients. 4D flow CMR maximum velocity measurements were consistently higher than those by 2D PCMR with a mean difference of 65 cm/s for the MPA, and 77 cm/s for both the RPA and LPA. Stroke volumes showed good agreement between 4D flow CMR and 2D PCMR. Maximum velocities in the PAs after ASO for TGA are consistently lower by 2D PCMR, while echocardiography only allows for PA assessment in a minority of cases. Stroke volumes showed good agreement between 4D flow CMR and 2D PCMR.

SELECTION OF CITATIONS