1.
Heart Rhythm ; 2024 May 24.
Article in English | MEDLINE | ID: mdl-38797310

ABSTRACT

BACKGROUND: Peridevice leak (PDL) after left atrial appendage closure (LAAC) portends adverse outcomes. OBJECTIVE: The purpose of this study was to assess the incidence, predictors, clinical implications, and temporal evolution of PDL after LAAC. METHODS: This single-center retrospective study included all patients who underwent LAAC with Watchman FLX and had no PDL detected at the time of implantation. The primary end point was the incidence of new PDL at initial imaging. The composite secondary end point included continued oral anticoagulation after initial imaging, device-related thrombus, stroke or transient ischemic attack, major bleeding, and need for PDL closure at longest follow-up. Temporal evolution of PDL was assessed in patients with available surveillance imaging. RESULTS: Of the 355 patients who completed imaging at 47 days (interquartile range [IQR] 6 days), 139 (39%) had new PDL with a mean leak size of 3.2 ± 1.4 mm (median 3.0 mm; IQR 2.0 mm; range 1.0-9.0 mm]. Multiple deployment attempts and larger device size were positive predictors of PDL, while increased contrast volume administration was a negative predictor of PDL. The composite secondary end point occurred in 42 (30%) and 33 (15%) patients with and without PDL, respectively (P < .001). Of the 139 patients with PDL, 43 (31%) had surveillance imaging where the leak size regressed from 3.7 ± 1.8 mm at 46 days (IQR 7 days) to 1.7 ± 2.0 mm at 189 days (IQR 127 days) (P < .001). The leak size regressed in 33 (77%), remained stable in 4 (9%), and progressed in 6 (14%) cases. CONCLUSION: Despite design improvements, LAAC with Watchman FLX demonstrates a significant incidence of PDL with meaningful clinical implications. Regardless of initial size, most leaks regressed over time.

3.
J Cardiovasc Electrophysiol ; 34(8): 1698-1705, 2023 08.
Article in English | MEDLINE | ID: mdl-37493499

ABSTRACT

INTRODUCTION: Among patients with non-valvular atrial fibrillation (AF) and percutaneous left atrial appendage closure (LAAC) undergoing direct current cardioversion (DCCV), the need for and use of LAA imaging and oral anticoagulation (OAC) is unclear. OBJECTIVE: The purpose of this study is to evaluate the real-world use of transesophageal echocardiography (TEE) or cardiac computed tomography angiography (CCTA) before DCCV and use of OAC pre- and post-DCCV in patients with AF status post percutaneous LAAC. METHODS: This retrospective single center study included all patients who underwent DCCV after percutaneous LAAC from 2016 to 2022. Key measures were completion of TEE or CCTA pre-DCCV, OAC use pre- and post-DCCV, incidence of left atrial thrombus (LAT) or device-related thrombus (DRT), incidence of peri-device leak (PDL), and DCCV-related complications (stroke, systemic embolism, device embolization, major bleeding, or death) within 30 days. RESULTS: A total of 76 patients with AF and LAAC underwent 122 cases of DCCV. LAAC consisted of 47 (62%), 28 (37%), and 1 (1%) case of Watchman 2.5, Watchman FLX, and Lariat, respectively. Among the 122 DCCV cases, 31 (25%) cases were identified as "non-guideline based" due to: (1) no OAC for 3 weeks and no LAA imaging within 48 h before DCCV in 12 (10%) cases, (2) no OAC for 4 weeks following DCCV in 16 (13%) cases, or (3) both in 3 (2%) cases. Among the 70 (57%) cases that underwent TEE or CCTA before DCCV, 16 (23%) cases had a PDL with a mean size of 3.0 ± 1.1 mm, and 4 (6%) cases had a LAT/DRT on TEE resulting in cancellation. There were no DCCV-related complications within 30 days. DISCUSSION: There is a widely varied practice pattern of TEE, CCTA, and OAC use with DCCV after LAAC, with a 6% rate of LAT/DRT. LAA imaging before DCCV appears prudent in all cases, especially within 1 year of LAAC, to assess for device position, PDL, and LAT/DRT.


Subject(s)
Atrial Appendage , Atrial Fibrillation , Heart Diseases , Stroke , Thrombosis , Humans , Retrospective Studies , Electric Countershock/adverse effects , Atrial Appendage/diagnostic imaging , Thrombosis/diagnostic imaging , Thrombosis/etiology , Thrombosis/prevention & control , Atrial Fibrillation/diagnostic imaging , Atrial Fibrillation/therapy , Echocardiography, Transesophageal , Treatment Outcome , Stroke/diagnostic imaging , Stroke/etiology , Stroke/prevention & control , Cardiac Catheterization/adverse effects
4.
J Innov Card Rhythm Manag ; 14(4): 5403-5409, 2023 Apr.
Article in English | MEDLINE | ID: mdl-37143575

ABSTRACT

Persistent left superior vena cava (PLSVC) is the most common congenital thoracic venous anomaly, with 0.47% of patients undergoing pacemaker or cardiac implantable device placement found to have PLSVC. This review article describes challenges and interventions to successfully insert cardiac implantable electronic device leads into patients with PLSVC by providing multiple unique case examples.

5.
Pacing Clin Electrophysiol ; 46(7): 745-751, 2023 07.
Article in English | MEDLINE | ID: mdl-37221927

ABSTRACT

BACKGROUND: Transesophageal echocardiography (TEE) and cardiac computed tomography angiography (CCTA) are currently utilized for left atrial appendage closure (LAAC) planning. During the recent global iodine contrast media shortage in 2022, cardiac magnetic resonance imaging (CMR) was utilized for the first time for LAAC planning. This study sought to assess the utility of CMR versus TEE for LAAC planning. METHODS: This single center retrospective study consisted of all patients who underwent preoperative CMR for LAAC with Watchman FLX or Amplatzer Amulet. Key measures were accuracy of LAA thrombus exclusion, ostial diameter, depth, lobe count, morphology, accuracy of predicted device size, and devices deployed per case. Bland-Altman Analysis was used to compare CMR versus TEE measurements of LAA ostial diameter and depth. RESULTS: 25 patients underwent preoperative CMR for LAAC planning. A total of 24 (96%) cases were successfully completed with 1.2 ± 0.5 devices deployed per case. Among the 18 patients who underwent intraoperative TEE, there was no significant difference between CMR versus TEE in LAA thrombus exclusion (CMR 83% vs. TEE 100% cases, p = .229), lobe count (CMR 1.7 ± 0.8 vs. TEE 1.4 ± 0.6, p = .177), morphology (p = .422), and accuracy of predicted device size (CMR 67% vs. TEE 72% cases, p = 1.000). When comparing the difference between CMR and TEE measurements, Bland-Altman analysis demonstrated no significant difference in LAA ostial diameter (CMR-TEE bias 0.7 mm, 95% CI [-1.1, 2.4], p = .420), but LAA depth was significantly larger with CMR versus TEE (CMR-TEE bias 7.4 mm, 95% CI [1.6, 13.2], p = .015). CONCLUSIONS: CMR is a promising alternative for LAAC planning in cases where TEE or CCTA are contraindicated or unavailable.


Subject(s)
Atrial Appendage , Atrial Fibrillation , Thrombosis , Humans , Atrial Appendage/diagnostic imaging , Atrial Appendage/surgery , Atrial Fibrillation/diagnostic imaging , Atrial Fibrillation/surgery , Retrospective Studies , Echocardiography, Transesophageal/methods , Magnetic Resonance Imaging , Thrombosis/diagnostic imaging , Cardiac Catheterization , Treatment Outcome
6.
J Cardiothorac Vasc Anesth ; 37(4): 627-631, 2023 04.
Article in English | MEDLINE | ID: mdl-36732130

ABSTRACT

The remede System (ZOLL Medical, Minnetonka, MN; Fig 1), which was approved by the Food and Drug Administration in October of 2017, is a transvenous device that stimulates the phrenic nerve for the treatment of central sleep apnea, which is often associated with heart failure and atrial fibrillation. Given the similarity in implantation procedure to pacemakers and implantable cardioverter/defibrillators, the remede System implantation often occurs in the electrophysiology laboratory. Despite the transvenous nature and close proximity to cardiac structures on radiographic imaging, the remede System does not have any cardiac pacing function/antiarrhythmia therapies, and it is important for an anesthesiologist to be able to recognize and manage such a device if they were to come across one preoperatively.


Subject(s)
Defibrillators, Implantable , Sleep Apnea, Central , Thoracic Surgical Procedures , Humans , Treatment Outcome , Phrenic Nerve , Sleep Apnea, Central/therapy
7.
Heart Rhythm ; 20(1): 122-133, 2023 01.
Article in English | MEDLINE | ID: mdl-36113768

ABSTRACT

The sinoatrial node (SAN) is the primary pacemaker of the human heart. It is a single, elongated, 3-dimensional (3D) intramural fibrotic structure located at the junction of the superior vena cava intercaval region bordering the crista terminalis (CT). SAN activation originates in the intranodal pacemakers and is conducted to the atria through 1 or more discrete sinoatrial conduction pathways. The complexity of the 3D SAN pacemaker structure and intramural conduction are underappreciated during clinical multielectrode mapping and ablation procedures of SAN and atrial arrhythmias. In fact, defining and targeting SAN is extremely challenging because, even during sinus rhythm, surface-only multielectrode mapping may not define the leading pacemaker sites in intramural SAN but instead misinterpret them as epicardial or endocardial exit sites through sinoatrial conduction pathways. These SAN exit sites may be distributed up to 50 mm along the CT beyond the ∼20-mm-long anatomic SAN structure. Moreover, because SAN reentrant tachycardia beats may exit through the same sinoatrial conduction pathway as during sinus rhythm, many SAN arrhythmias are underdiagnosed. Misinterpretation of arrhythmia sources and/or mechanisms (eg, enhanced automaticity, intranodal vs CT reentry) limits diagnosis and success of catheter ablation treatments for poorly understood SAN arrhythmias. The aim of this review is to provide a state-of-the-art overview of the 3D structure and function of the human SAN complex, mechanisms of SAN arrhythmias and available approaches for electrophysiological mapping, 3D structural imaging, pharmacologic interventions, and ablation to improve diagnosis and mechanistic treatment of SAN and atrial arrhythmias.


Subject(s)
Atrial Fibrillation , Sinoatrial Node , Humans , Heart Conduction System/physiology , Vena Cava, Superior , Heart Atria
8.
J Cardiovasc Electrophysiol ; 33(9): 2111-2115, 2022 09.
Article in English | MEDLINE | ID: mdl-35842796

ABSTRACT

INTRODUCTION: Leadless cardiac pacing has not been widely utilized in pediatric patients, in part due to concerns regarding size of the delivery sheath and the potential for vascular injury. METHODS: We present a case of leadless pacemaker implantation via internal jugular vein without a surgical cutdown. RESULTS: A leadless pacemaker was successfully implanted in the right ventricle via internal jugular approach in a pediatric patient with congenital heart disease. CONCLUSION: This is a novel approach to leadless pacemaker implantation that could broaden the utilization of this technology to the vulnerable population of children, especially those with congenital heart disease.


Subject(s)
Pacemaker, Artificial , Child , Heart Ventricles , Humans , Prostheses and Implants
9.
J Cardiovasc Electrophysiol ; 32(11): 3027-3034, 2021 11.
Article in English | MEDLINE | ID: mdl-34554620

ABSTRACT

INTRODUCTION: Defibrillation testing (DT) is recommended during the subcutaneous defibrillator (S-ICD) placement. We sought to compare 10 J shock impedance in sinus rhythm (SR) with 65 J defibrillation impedance and evaluate device position on a postimplant chest X-ray (CXR) using an intermuscular (IM) technique. METHODS: Consecutive S-ICD implantations between 12/2019 and 12/2020 at The Ohio State University were reviewed. All implantations were performed using a two-incision IM technique. Standard DT with 65 J shock and 10 J shock in SR were performed unless contraindicated. The PRAETORIAN score was calculated based on CXR. RESULTS: A total of 37 patients (age: 47.2 ± 15.8 years old, male: n = 26 [70.3%], body mass index: 30.1 ± 6.7 kg/m2 ) underwent IM S-ICD implantation, and of those, 27 (73%) underwent both 65 J shock and 10 J shock in SR. The coefficient of determination (R2 ) between 10 J shock impedance and 65 J shock impedance was 0.84. The mean of an impedance difference was 1.6 ± 4.8 Ω (minimum - 11 and maximum 8). Postimplant CXR was available for 33 out of 37 patients (89.2%). The PRAETORIAN score was less than 90 in all patients and the mean score was 32.7 ± 8.8. CONCLUSION: We demonstrated that 10 J shock impedance in SR correlated well with 65 J defibrillation impedance during IM S-ICD implantation. An IM implantation technique provides excellent generator location on postimplant CXR. The IM technique combined with 10 J shock in SR may be sufficient to predict and ensure the defibrillation efficacy of the S-ICD.


Subject(s)
Defibrillators, Implantable , Adult , Arrhythmias, Cardiac , Electric Countershock , Electric Impedance , Humans , Male , Middle Aged , Ohio , Subcutaneous Tissue
10.
J Innov Card Rhythm Manag ; 12(6): 4562-4568, 2021 Jun.
Article in English | MEDLINE | ID: mdl-34234991

ABSTRACT

As leadless pacing (LP) use is expected to increase, it becomes increasingly essential that operators become familiar with the tools and techniques needed to retrieve an LP successfully. The purpose of this review is to describe a stepwise approach for the successful retrieval of tine-based LP devices, including ways to minimize complications.

12.
JACC Clin Electrophysiol ; 7(6): 745-754, 2021 06.
Article in English | MEDLINE | ID: mdl-33516715

ABSTRACT

OBJECTIVES: This study reports resource use and economic implications of rhythm monitoring with subcutaneous cardiac rhythm monitors (SCRMs). BACKGROUND: SCRMs generate a substantial amount of data that requires timely adjudication for appropriate clinical care. Resource use for SCRM monitoring is not known. METHODS: The study included consecutive transmissions during 4 weeks from 1,811 SCRMs. Resource use was quantified by assessment of time commitment of device clinic personnel and electrophysiologists for data adjudication. Incidence and characteristics of false positive (FP) episodes were assessed. Impact of custom programming for arrhythmia detection on incidence of FP episodes and resource use was analyzed. RESULTS: A total of 1,457 transmissions (alerts = 462; full downloads = 995) were received during study period. Average device clinic personnel time for adjudication of 1 transmission was 15 ± 6 min. This totaled to 364 h spent (2.3 full-time staff) over the 4-week period, which translated into a salary cost of $12,000 U.S. dollars (USD). Average time spent by an electrophysiologist for 1 transmission was 1.5 ± 1 min and totaled to 37 h for 4 weeks, which translated into an estimated cost of $9,600 USD. Of 1,457 total transmissions, 512 (35%) represented multiple transmissions from the same patients, which resulted in no additional reimbursement. Incidence of FP episodes in the entire cohort was 50% and was variable in alert (60%) and full download (49%) (p = 0.04) transmissions. When SCRMs with manufacturer suggested nominal programming and institutional custom programming were compared, there was a reduction in FP episodes (55% vs. 16%; p = 0.01), which translated to a 34% reduction in resource use for data adjudication. CONCLUSIONS: SCRM data adjudication requires significant resources. Custom programming for SCRMs may overcome the data deluge.


Subject(s)
Defibrillators, Implantable , Arrhythmias, Cardiac/diagnosis , Arrhythmias, Cardiac/epidemiology , Humans , Incidence , Monitoring, Physiologic
14.
JACC Clin Electrophysiol ; 6(10): 1318-1331, 2020 10.
Article in English | MEDLINE | ID: mdl-33092762

ABSTRACT

Leadless pacemakers (LPs) have emerged as a meaningful alternative to transvenous pacemakers for single-ventricular pacing. LPs eliminate many of lead- and pocket-associated complications observed with transvenous pacemakers. Owing to the lack of atrioventricular synchronous pacing until recently, the use of LP was generally reserved for those patients who either required minimal ventricular pacing or had permanent atrial fibrillation. The only commercially available LP is the Micra transcatheter pacing system (Micra-TPS, Medtronic Inc. Fridley, Minnesota), which requires insertion of a 27-F (outer diameter) introducer sheath in the femoral vein. The LP is delivered to the right ventricle using a 23-F delivery catheter. Owing to the need for a large-bore sheath, the pivotal studies for the Micra transcatheter pacing system excluded patients with indwelling inferior vena cava filters and included only a few patients with bioprosthetic or repaired tricuspid valve. Subsequent real-world experience has demonstrated the overall safety and feasibility of LP placement, and use in various unconventional clinical settings has been validated, albeit with specific precautions. Additionally, incorporation of adjunctive techniques and strategies can improve the safety of the procedure in routine clinical settings as well. The objective of this state-of-the-art review is to highlight the key procedural elements to facilitate safe and efficient implantation of LP in routine as well as in unique clinical settings.


Subject(s)
Atrial Fibrillation , Pacemaker, Artificial , Cardiac Pacing, Artificial , Humans , Minnesota , Treatment Outcome
18.
Heart Rhythm ; 17(1): 75-80, 2020 01.
Article in English | MEDLINE | ID: mdl-31323348

ABSTRACT

BACKGROUND: Implantable loop recorder (ILR) is preferred strategy for prolonged rhythm monitoring. OBJECTIVE: The purpose of this study was to report the incidence and causes of false-positive (FP) diagnoses during remote monitoring with ILR. METHODS: During a 4-week study period, all consecutive remote transmissions in patients with ILR (Reveal LINQ, Medtronic) implanted for atrial fibrillation (AF) surveillance, cryptogenic stroke (CS), and syncope were reviewed. A nurse specializing in device management and an electrophysiologist adjudicated all transmissions. Primary endpoint of the study was incidence of FP in patients with AF, CS, and syncope. RESULTS: A total of 695 remote transmissions (scheduled downloads: 414; Alerts: 281) sent from 559 patients were adjudicated. The majority of patients had ILR for AF surveillance (n = 321), followed by CS (n =168) and syncope (n = 70) with nominal programming for rhythm diagnosis. Incidence of FP transmissions during the study period was 46%, 86%, and 71% in patients with AF, CS, and syncope, respectively. Incidence of FP transmissions was higher in patients with CS and syncope than in patients with AF (P <.001). For scheduled transmissions, primary causes of FP were signal dropout and undersensing; for alert transmissions, primary reasons for FP were premature atrial and ventricular ectopy. CONCLUSION: Incidence of FP during remote monitoring with nominal settings on this ILR was substantial, ranging from 46% to 86% depending on the indication for implantation. Adjudication of these transmissions required a considerable time commitment from electrophysiologists and device clinic personnel but would be required to avoid misdiagnosis and potential errors in clinical management.


Subject(s)
Atrial Fibrillation/physiopathology , Electrocardiography, Ambulatory/instrumentation , Electrodes, Implanted/adverse effects , Monitoring, Physiologic/methods , Aged , Atrial Fibrillation/diagnosis , Equipment Failure , Female , Humans , Incidence , Male , Middle Aged , Prognosis
19.
J Interv Card Electrophysiol ; 57(2): 311-318, 2020 Mar.
Article in English | MEDLINE | ID: mdl-31813098

ABSTRACT

PURPOSE: To assess the feasibility and safety of same-day discharge after S-ICD implantation by implementing a specific analgesia protocol and phone follow-up. METHODS: Consecutive patients presenting for outpatient S-ICD implantation were enrolled between 1/1/2018 and 4/30/2019. An analgesia protocol included pre-operative acetaminophen and oxycodone, intraoperative local bupivacaine, and limited use of oxycodone-acetaminophen at discharge. The primary outcome was successful same-day discharge. Numerical Pain Rating Scale (NPRS) on postoperative day (POD) 1, 3, 14, and 30 and any unplanned health care visits during the 1-month follow-up period were assessed. RESULTS: Out of 53 potentially eligible S-ICD patients, 49 patients (92.5%) were enrolled and successfully discharged on the same day. Mean age of these 49 patients was 47 ± 14 years. There were no acute procedural complications. Severe pain (NPRS ≥ 8) on POD 0, 1, and 3 was present in 14.3%, 14.3%, and 8.2% of patients, respectively. The total in-hospital stay was 534 ± 80 min. Four unplanned visits (8%) due to cardiac or device-related issues occurred during 1-month follow-up, including 2 patients with heart failure exacerbation, one patient with an incisional infection, and one patient with inappropriate shocks. CONCLUSIONS: With the appropriate institutional protocol including specific analgesics and phone follow-up, same-day discharge after outpatient S-ICD implantation is feasible and appears safe for most patients.. Device-related pain can be severe in the first 3 days post-implantation and can be successfully treated with limited supply of narcotic medications.


Subject(s)
Analgesia/methods , Defibrillators, Implantable , Patient Safety , Prosthesis Implantation/methods , Aged , Continuity of Patient Care , Feasibility Studies , Female , Humans , Length of Stay/statistics & numerical data , Male , Middle Aged , Pain Management , Pain Measurement
20.
Pacing Clin Electrophysiol ; 42(12): 1552-1557, 2019 12.
Article in English | MEDLINE | ID: mdl-31702059

ABSTRACT

BACKGROUND: The perioperative anesthesia care during subcutaneous implantable cardioverter-defibrillator (S-ICD) implantation is still evolving. OBJECTIVE: To assess the feasibility and safety of S-ICD implantation with monitored anesthesia care (MAC) versus general anesthesia (GA) in a tertiary care center. METHODS: This is a single-center retrospective study of patients undergoing S-ICD implantation between October 2012 and May 2019. Patients were categorized into MAC and GA group based on the mode of anesthesia. Procedural success without escalation to GA was the primary endpoint of the study, whereas intraprocedural hemodynamics, need of pharmacological support for hypotension and bradycardia, length of the procedure, stay in the post-anesthesia care unit, and postoperative pain were assessed as secondary endpoints. RESULTS: The study comprises 287 patients with MAC in 111 and GA in 176 patients. Compared to MAC, patients in GA group were younger and had a higher body mass index. All patients had successful S-ICD implantation. Only one patient (0.9%) in the MAC group was converted to GA. Despite a similar baseline heart rate (HR) and mean arterial blood pressure (MAP) in both groups, patients with GA had significantly lower HR and MAP during the procedure and more frequently required pharmacological hemodynamic support. Length of the procedure, stay in the postanesthesia care unit, and postoperative pain was similar in both groups. CONCLUSION: This retrospective experience suggests that implantation of S-ICD is feasible and safe with MAC. Use of GA is associated with more frequent administration of hemodynamic drugs during S-ICD implantation.


Subject(s)
Anesthesia/methods , Defibrillators, Implantable , Prosthesis Implantation/methods , Anesthesia, General , Anesthesia, Local , Bradycardia/drug therapy , Feasibility Studies , Female , Hemodynamics , Humans , Hypotension/drug therapy , Length of Stay/statistics & numerical data , Male , Middle Aged , Operative Time , Pain Measurement , Pain, Postoperative/prevention & control , Retrospective Studies