Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
J Bronchology Interv Pulmonol ; 31(2): 105-116, 2024 Apr 01.
Article in English | MEDLINE | ID: mdl-37459049

ABSTRACT

BACKGROUND: A dedicated anesthesia protocol for bronchoscopic lung biopsy-lung navigation ventilation protocol (LNVP)-specifically designed to mitigate atelectasis and reduce unnecessary respiratory motion, has been recently described. LNVP demonstrated significantly reduced dependent ground glass, sublobar/lobar atelectasis, and atelectasis obscuring target lesions compared with conventional ventilation. METHODS: In this retrospective, single-center study, we examine the impact of LNVP on 100 consecutive patients during peripheral lung lesion biopsy. We report the incidence of atelectasis using cone beam computed tomography imaging, observed ventilatory findings, anesthesia medications, and outcomes, including diagnostic yield, radiation exposure, and complications. RESULTS: Atelectasis was observed in a minority of subjects: ground glass opacity atelectasis was seen in 30 patients by reader 1 (28%) and in 18 patients by reader 2 (17%), with good agreement between readers (κ = 0.78). Sublobar/lobar atelectasis was observed in 23 patients by reader 1 and 26 patients by reader 2, also demonstrating good agreement (κ = 0.67). Atelectasis obscured target lesions in very few cases: 0 patients (0%, reader 1) and 3 patients (3%, reader 2). Diagnostic yield was 85.9% based on the AQuIRE definition. Pathology demonstrated 57 of 106 lesions (54%) were malignant, 34 lesions (32%) were benign, and 15 lesions (14%) were nondiagnostic. CONCLUSION: Cone beam computed tomography images confirmed low rates of atelectasis, high tool-in-lesion confirmation rate, and high diagnostic yield. LNVP has a similar safety profile to conventional bronchoscopy. Most patients will require intravenous fluid and vasopressor support. Further study of LNVP and other ventilation protocols are necessary to understand the impact of ventilation protocols on bronchoscopic peripheral lung biopsy.


Subject(s)
Breath Holding , Pulmonary Atelectasis , Humans , Tidal Volume , Retrospective Studies , Lung/diagnostic imaging , Lung/pathology , Positive-Pressure Respiration/adverse effects , Pulmonary Atelectasis/diagnostic imaging , Pulmonary Atelectasis/etiology , Cone-Beam Computed Tomography , Biopsy/adverse effects
2.
J Bronchology Interv Pulmonol ; 31(2): 117-125, 2024 Apr 01.
Article in English | MEDLINE | ID: mdl-37450607

ABSTRACT

BACKGROUND: Compared with the standard cryoprobe, the novel ultrathin 1.1 mm cryoprobe (UTCP) has improved ergonomics, shape memory, and flexibility. The performance of UTCP has demonstrated promising results in several small trials. METHODS: In this single-center, retrospective review, we examine 200 (N=200) consecutive patients referred for cone beam CT bronchoscopic biopsy of peripheral lung lesions. We utilized an extended multimodality approach, including transbronchial needle aspirate, brush, traditional forces biopsies, UTCP biopsies, and BAL. We analyzed tool in lesion, tool touch lesion, center strike rates, and diagnostic yield. We assessed for molecular adequacy and analyzed safety. RESULTS: A total of 222 lesions were biopsied. We achieved a tool in lesion or tool touch lesion confirmation for all biopsy attempts (100%) and a center strike rate of 68%. AQuIRE diagnostic yield was 90%, with 60% malignant, 30% benign lung nodules, and 10% nondiagnostic. UTCP was diagnostic in 3.6 % of peripheral lung lesions biopsies when all other modalities were nondiagnostic; thus, raising our overall diagnostic yield from 86.4% to 90.1%. Our analysis demonstrates superior adequacy for molecular analysis for histologic samples (TBBX or UTCP) versus cytologic samples (FNA) ( P <0.001). Three patients (1.5%) had a pneumothorax, and 1 patient (0.5%) had moderate bleeding. CONCLUSION: UTCP was diagnostic in 3.6% of peripheral lung lesions when all other modalities were nondiagnostic. In the setting of CBCT guidance, UTCP has a similar safety profile to standard biopsy tools. Future trials are warranted to assess UTCP and its impact on peripheral lung lesion biopsies.


Subject(s)
Lung Neoplasms , Humans , Lung Neoplasms/diagnostic imaging , Lung Neoplasms/pathology , Bronchoscopy/methods , Biopsy/adverse effects , Lung/diagnostic imaging , Lung/pathology , Cone-Beam Computed Tomography , Retrospective Studies
SELECTION OF CITATIONS
SEARCH DETAIL
...