Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 3 de 3
1.
PLoS One ; 18(11): e0293984, 2023.
Article En | MEDLINE | ID: mdl-37963155

OBJECTIVE: We aim to assess the accuracy and effectiveness of the HemoCue 301, a point-of-care (POC) device for measuring hemoglobin levels, and detecting anemia among individuals living in Tumbes, a rural, underserved area in Northern Peru. METHODS: Baseline analysis of a clinical trial aimed at assessing the effect of multi-fortified bread (NCT05103709). Adult women with capillary blood HemoCue 301 readings below 12 g/dL were recruited in coastal city of Tumbes, Peru. A total of 306 women took part of the study, venous blood samples were taken and analyzed with an automated hematology analyzer. Serum samples were used to measure ferritin, serum iron and C reactive protein. RESULTS: Capillary blood measured by the Hemocue 301 has a bias of 0.36 ± 0.93 g/dL respect to the automated Hb. More than 50% of women with normal ferritin values were classified as anemics according to the HemoCue 301. Automated Hb cut-off of 10.8 g/dL [AUC 0.82 (0.77-0.88)] had a specificity of 0.817 and a sensitivity 0.711 while with the HemoCue 301 cut-off of 11.1 g/dL [AUC 0.71 (0.62-0.79)] had a specificity of 0.697 and a sensitivity 0.688. The performance of the automated Hb cut-off was significantly better than the HemoCue (p<0.001). CONCLUSION: Caution must be taken when using POC devices, especially with values around the threshold. Cut-off values found in our study could be used as surrogate means when no confirmatory tests are available. Clinical outcomes should be prioritized when diagnosing iron deficiency anemia in women of reproductive age to ensure proper diagnosis.


Anemia , Hematology , Adult , Humans , Female , Peru/epidemiology , Hemoglobins/analysis , Anemia/diagnosis , Hemoglobinometry , Ferritins
2.
Wellcome Open Res ; 8: 171, 2023.
Article En | MEDLINE | ID: mdl-37766850

Background: Some sputum smear microscopy protocols recommend placing filter paper over sputum smears during staining for Mycobacterium tuberculosis (TB) . We found no published evidence assessing whether this is beneficial. We aimed to evaluate the effect of filter paper on sputum smear microscopy results. Methods: Sputum samples were collected from 30 patients with confirmed pulmonary TB and 4 healthy control participants. From each sputum sample, six smears (204 smears in total) were prepared for staining with Ziehl-Neelsen (ZN), auramine or viability staining with fluorescein diacetate (FDA). Half of the slides subjected to each staining protocol were randomly selected to have Whatman grade 3 filter paper placed over the dried smears prior to stain application and removed prior to stain washing. The counts of acid-fast bacilli (AFB) and precipitates per 100 high-power microscopy fields of view, and the proportion of smear that appeared to have been washed away were recorded. Statistical analysis used a linear regression model adjusted by staining technique with a random effects term to correct for between-sample variability.   Results: The inclusion of filter paper in the staining protocol significantly decreased microscopy positivity independent of staining with ZN, auramine or FDA (p=0.01). Consistent with this finding, there were lower smear grades in slides stained using filter paper versus without (p=0.04), and filter paper use reduced AFB counts by 0.28 logarithms (95% confidence intervals, CI=0.018, 0.54, p=0.04) independent of staining technique. In all analyses, auramine was consistently more sensitive with higher AFB counts versus ZN (p=0.001), whereas FDA had lower sensitivity and lower AFB counts (p<0.0001). Filter paper use was not associated with the presence of any precipitate (p=0.5) or the probability of any smear washing away (p=0.6) during the staining process. Conclusions: Filter paper reduced the sensitivity of AFB microscopy and had no detectable beneficial effects so is not recommended.

3.
Int J Med Inform ; 148: 104404, 2021 04.
Article En | MEDLINE | ID: mdl-33581476

OBJECTIVE: This study sought to assess the effect of reading augmented reality (AR) books on salivary cortisol levels in hospitalized pediatric patients compared to reading a standard children's book. METHODS: This was a randomized, two-period, cross-over trial in hospitalized children aged 7-11 years. AR books currently in the market were used as intervention. Complete block randomization was used to randomize the order of the intervention. Children allocated to the 'AR-first' group received the book, a tablet and were left to interact independently with the technology for an hour. After a 48 -h wash-out period, children received a standard book. 'Standard-book-first' group received only the standard book and after wash-out received the tablet and the AR book. Salivary cortisol and a validated visual analogue scale (VAS) for psychological stress were assessed at the beginning and at the end of each intervention. RESULTS: A total of 29 children were recruited in the study. One was lost during follow up. Cortisol levels decreased after the AR intervention (P = 0.019). Nevertheless, the decrease was not greater than the one associated to reading the standard book. VAS scores increased after the AR intervention (P < 0.001). DISCUSSION: There is evidence of order and sequence effects that might explain results. First assessment of AR-based interventions on stress. Results justify further research. CONCLUSIONS: There was no evidence that reading AR books diminished cortisol levels more than reading a standard book. AR-books improved VAS score for psychological stress compared to a standard book.


Augmented Reality , Hydrocortisone , Books , Child , Cross-Over Studies , Humans , Reading
...