1.
J Sep Sci ; 42(21): 3340-3351, 2019 Nov.
Article in English | MEDLINE | ID: mdl-31509638

ABSTRACT

This research deals with the development of a stability-indicating high-performance liquid chromatography method for simultaneous determination of amprolium hydrochloride and ethopabate. To the best of our knowledge, no comprehensive stability-indicating method has been reported for analysis of this mixture. Separation was achieved using Kromasil cyano column with gradient elution of the mobile phase composed of sodium hexane sulfonate solution and methanol. Quantification was based on measuring peak areas at 266 nm. Amprolium and ethopabate peaks eluted at retention times 10.42 and 18.53 min, respectively. The proposed procedure was validated with respect to system suitability, linearity, ranges, precision, accuracy, specificity, robustness, detection, and quantification limits. Linearity ranges for amprolium and ethopabate were 1.5-240 and 1-160 µg/mL, respectively. Analytes were subjected to stress conditions of hydrolysis, oxidation and thermal degradation. The proposed method enabled resolution of drugs from their forced-degradation products and amprolium related substance (2-picoline). Moreover, specificity was verified by resolution of the analytes from about 22 drugs used in antimicrobial veterinary products. The validated method was successfully applied to assay of the combined veterinary powder dosage form, additionally it was implemented in the accelerated stability study of the dosage form when stored for six months at 40°C and 75% relative humidity.


Subject(s)
Amprolium/analysis , Ethopabate/analysis , Veterinary Drugs/analysis , Chromatography, High Pressure Liquid , Drug Stability , Humidity , Powders/chemistry
2.
Drug Dev Ind Pharm ; 45(7): 1111-1119, 2019 Jul.
Article in English | MEDLINE | ID: mdl-30929537

ABSTRACT

This study describes a simple, sensitive, specific and generic HPLC-DAD method for simultaneous determination of four drugs prescribed for treatment of Hepatitis C Virus (HCV) infection. Investigated drugs include daclatasvir (DAC), ledipasvir (LED), sofosbuvir (SOF) and ribavirin (RIB). Successful separation was accomplished using Thermohypersil BDS-C8 column (4.6 × 250 mm, 5 µm) with gradient elution of the mobile phase consisted of mixed phosphate buffer pH 7.5 and methanol. Gradient elution started with 25% methanol, ramped up linearly to 80% in 15 min then kept constant till the end of the run. Flow rate was 1.5 mL/min. Peak areas were measured at 235, 260, 315, and 332 nm for RIB, SOF, DAC, and LED, respectively. Peaks of the analytes were perfectly resolved with retention times 2.0, 12.1, 14.7, and 17.2 min for RIB, SOF, DAC, and LED, respectively. The developed method was validated according to ICH guidelines with respect to system suitability, linearity, ranges, accuracy, precision, specificity, robustness, and limits of detection and quantification. The proposed method showed good linearity in the ranges 5-500, 2-300, 0.5-75, and 0.5-75 µg/mL for RIB, SOF, DAC, and LED respectively. Limits of detection were 0.10-0.66 µg/mL for the analyzed drugs. Specificity was established by separation of target drugs from 7 process-related impurities for SOF including its major metabolite (GS-331007). Applicability of the proposed method to real life situations was assessed through the analysis of four different pharmaceutical formulations and satisfactory results were obtained. Additionally, dissolution profiles of the 4 drugs were studied using the developed method.


Subject(s)
Antiviral Agents/analysis , Antiviral Agents/chemistry , Benzimidazoles/chemistry , Chromatography, High Pressure Liquid/methods , Fluorenes/chemistry , Imidazoles/chemistry , Ribavirin/chemistry , Sofosbuvir/chemistry , Carbamates , Limit of Detection , Pyrrolidines , Reproducibility of Results , Sensitivity and Specificity , Solubility/drug effects , Valine/analogs & derivatives
3.
J AOAC Int ; 101(4): 993-1000, 2018 Jul 01.
Article in English | MEDLINE | ID: mdl-28859698

ABSTRACT

This work presents a simple, sensitive, and generic HPLC-diode-array detection method for the simultaneous determination of six drugs prescribed for the treatment of open-angle glaucoma and ocular hypertension. The investigated drugs include brimonidine tartarate (BMN), acetazolamide (AZA), brinzomaide (BZA), dorzolamide HCl (DZA), levobunolol HCl (LVB), and timolol maleate (TIM). Efficient chromatographic separation was achieved using a Thermo Hypersil BDS C18 column (4.6 × 250 mm, 5 µm) with a mobile phase consisting of phosphate buffer pH 5 and acetonitrile in a ratio of 78 + 22. The flow rate was 1 mL/min, and quantification was based on measuring peak areas at 298 nm for TIM and 254 nm for the other drugs. Peaks were perfectly resolved, with retention times at 3.06, 3.87, 4.53, 5.78, 7.31, and 10.78 min for BMN, AZA, DZA, TIM, LVB, and BZA respectively. The developed method was validated according to International Conference on Harmonization guidelines with respect to system suitability, linearity, ranges, accuracy, precision, robustness, and LODs and LOQs. The proposed method showed good linearity in the ranges of 2-80, 2.5-100, 2.5-100, 5-200, 3.75-150, and 1.75-70 µg/mL for BMN, AZA, DZA, TIM, LVB, and BZA, respectively. LODs were 0.20-1.01 µg/mL for the analyzed compounds. Applicability of the proposed method to real-life situations was assessed through the analysis of five different pharmaceutical formulations, and satisfactory results were obtained.


Subject(s)
Antihypertensive Agents/analysis , Carbonic Anhydrase Inhibitors/analysis , Chromatography, High Pressure Liquid/methods , Acetazolamide/analysis , Brimonidine Tartrate/analysis , Glaucoma/drug therapy , Humans , Levobunolol/analysis , Sulfonamides/analysis , Thiophenes/analysis , Timolol/analysis
4.
J Sep Sci ; 39(9): 1656-65, 2016 May.
Article in English | MEDLINE | ID: mdl-26970347

ABSTRACT

This work presents a simple, sensitive and generic high-performance liquid chromatography with diode array detection method for the simultaneous determination of seven drugs prescribed for the treatment of erectile dysfunction and premature ejaculation. Investigated drugs include the phosphodiesterase-5 inhibitors: sildenafil, tadalafil, and vardenafil, in addition to the selective serotonin reuptake inhibitors: dapoxetine, duloxetine, fluoxetine, and paroxetine. The drugs were separated using a Waters C8 column (4.6 × 250 mm, 5 µm) with the mobile phase consisting of phosphate buffer pH 3, acetonitrile and methanol in the ratio 60:33:7. The flow rate was 1.2 mL/min, and quantification was based on measuring peak areas at 225 nm. Peaks were perfectly resolved with retention times 3.3, 3.9, 6.4, 7.5, 9.5, 10.7, and 13.4 min for vardenafil, sildenafil, paroxetine, duloxetine, dapoxetine, fluoxetine, and tadalafil, respectively. The developed method was validated with respect to system suitability, linearity, ranges, accuracy, precision, robustness, and limits of detection and quantification. The proposed method showed good linearity in the ranges 5-500, 2-200, 2-200, 3-300, 1.5-150, 2-200, and 2-200 µg/mL for sildenafil, tadalafil, vardenafil, dapoxetine, duloxetine fluoxetine, and paroxetine, respectively. The limits of detection were 0.18-0.38 µg/mL for the analyzed compounds. The applicability of the proposed method to real life situations was assessed through the analysis of commercial tablets, and satisfactory results were obtained.


Subject(s)
Phosphodiesterase 5 Inhibitors/analysis , Selective Serotonin Reuptake Inhibitors/analysis , Sexual Behavior/drug effects , Chromatography, High Pressure Liquid , Humans , Male , Molecular Structure , Phosphodiesterase 5 Inhibitors/pharmacology , Selective Serotonin Reuptake Inhibitors/pharmacology