Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 45
Filter
1.
Article in English | MEDLINE | ID: mdl-38336883

ABSTRACT

OBJECTIVES: To determine the clinical associations and predictive value of two thresholds of negative dual-energy CT (DECT) for MSU crystal deposition in gout patients initiating urate lowering therapy (ULT), and identify which threshold is more clinically relevant. METHODS: Patients from the CRYSTALILLE cohort with a diagnosis of gout naive to ULT with baseline DECT scans of knees and feet were selected. Two thresholds of positivity for DECT detection of MSU crystal deposition were considered (<0.01 cm3 and <0.1 cm3). Baseline characteristics and the prediction of key outcomes after ULT initiation including reaching serum urate (SU) levels <6.0 and 5.0 mg/dl and occurrence of flares at 6, 12 and 24 months, associated with both thresholds of negative DECTs were compared with those of. PATIENT: s having positive DECT scans. RESULTS: 211 patients aged 66.2 years [57; 75.8] with a symptom duration of 3 years [0; 7.8] were included. 38/211 (18%) and 90/211 (43%) had negative DECT scans for the 0.01 and 0.1 cm3 thresholds, respectively. Factors associated with negative DECT scans were younger age, shorter symptom duration, and absence of cardiovascular disease for both volume thresholds. 9/39 (23.1%), 3/26 (11.5%), and 1/18 (5.6%) of patients with <0.1 cm3 MSU crystals had flares at 6, 12 and 24 months, respectively, compared with 18/45 (40.0%), 9/36 (25.0%) and 2/18 (11.1%) patients with ≥0.1 cm3 (p> 0.05).Overall, 95 patients (68.3%) reached SU levels <6.0 mg/dl and 68 (48.9%) <5.0 mg/dl, without any difference between positive and negative DECTs, with ULT dosages which tended to be lower in patients with negative DECT. CONCLUSION: The 0.1 cm3 threshold was better correlated to clinical presentation and evolution than 0.01 cm3. Patients with gout with negative DECTs exhibit milder disease and a lower comorbidity burden. They do not exhibit particularly easy-to-treat hyperuricemia, but may have a lower risk of flares.

2.
RMD Open ; 9(4)2023 11.
Article in English | MEDLINE | ID: mdl-37940341

ABSTRACT

OBJECTIVE: To examine factors influencing the kinetics of monosodium urate (MSU) crystal dissolution measured with dual-energy computed tomography (DECT) during follow-up of patients with gout. METHODS: Patients with a diagnosis of gout with baseline knees and feet DECT scans exhibiting MSU crystal volumes ≥0.1 cm3 and at least one follow-up DECT were included. Spearman's correlation coefficient was used to search for association between change from baseline MSU crystal volume at 6, 12, 18 and 24 months and serum urate (SU) level. Associations between percentage change from the baseline volume of MSU crystal deposits and explanatory variables were assessed using linear mixed models. RESULTS: Sixty-two patients (age 67.3±12.8 years; 53 (85%) males) cumulating 104 follow-up DECT scans were included. Overall, SU target levels (<6.0 and <5.0 mg/dL) were achieved by 48 (77%) and 36 (58%) patients, respectively. There was a good correlation (r=0.66; p<0.0001) observed between SU level and percentage change in MSU crystal volume. The median decrease from baseline MSU crystal volume was greater in patients reaching the <5.0 mg/dL SU target than in those reaching ≥5.0 SU <6.0 mg/dL: -85% (95% CI: -94% to -72%) versus -40% (-57% to -22%; p<0.05) at 12 months. In multivariable analysis, time (in days) with a multilevel coefficient of -0.06 (95% CI: -0.08 to -0.03, p<0.001), hypertension (coefficient: 41.87, 95% CI: 16.38 to 67.18, p<0.01) and SU level <5.0 mg/dL (coefficient: -39.46, 95% CI: -70.93 to -8.34, p=0.02) were the only variables significantly associated with MSU crystal volume change. CONCLUSION: In patients with DECT-measured MSU crystal deposition, reaching the <5.0 mg/dL SU target provides more extensive and rapid crystal dissolution than reaching the <6.0 mg/dL SU target.


Subject(s)
Gout , Uric Acid , Male , Humans , Middle Aged , Aged , Aged, 80 and over , Female , Uric Acid/analysis , Gout/diagnostic imaging , Foot , Tomography, X-Ray Computed/methods
3.
Int J Rheum Dis ; 26(12): 2450-2459, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37786305

ABSTRACT

OBJECTIVES: To assess whether the extent of monosodium urate (MSU) crystal deposition estimated by ultrasound could predict renal and cardiometabolic events during urate-lowering therapy (ULT). METHODS: A prospective study on gout patients from two referral centers initiating ULT who underwent baseline ultrasound and were followed for 1 year. Ultrasound scans assessed six joints for double-contour (DC) signs and tophi. A five-point change (mL/min/1.73 m2 ) in the glomerular filtration rate at month 12 (M12) was considered significant. Outcomes of interest were renal function degraded versus improved and a composite cardiometabolic outcome (new hypertension, diabetes, atherosclerotic disease, and cardiovascular death). Homogeneity analyses and Cox regression models were performed. RESULTS: One hundred sixty patients were recruited. At baseline, 81.1% of patients (n = 129) showed sonographic tophi with a mean number of 1.4 joints (±1.3) with a DC sign. At M12, 18 patients (11.3%) were lost to follow-up. The serum urate (SU) target (<6.0 mg/dL) was reached in 86 patients (69.9%). Regarding renal function, 15.9% of patients showed improvement, while in 31.0% it degraded. Fourteen new cardiometabolic events occurred in 12 patients. Neither the DC sign nor tophi showed any significant impact on the outcomes of interest. Baseline SU level was higher in those with renal improvement but not with renal decline, while achieving the SU target protected against new cardiometabolic events (HR = 0.2; 95% CI: 0.05-0.81). CONCLUSIONS: Sonographic MSU crystal burden was unhelpful in predicting renal and cardiometabolic events during the first year of ULT. Reaching the SU target prevented cardiometabolic events, while its benefit in preserving/improving renal function is unclear.


Subject(s)
Gout , Hypertension , Humans , Uric Acid , Gout Suppressants/adverse effects , Prospective Studies , Gout/diagnostic imaging , Gout/drug therapy , Kidney/physiology
4.
Cartilage ; : 19476035231172152, 2023 Jun 13.
Article in English | MEDLINE | ID: mdl-37312537

ABSTRACT

OBJECTIVE: To characterize dual-energy computed tomography (DECT) changes depicting hyaline cartilage changes in gout patients with and without osteoarthritis (OA) and in comparators without gout. DESIGN: Patients with suspected crystal-associated arthropathy were enrolled and underwent bilateral DECT scans of the knees. Standardized regions of interest were defined in the femorotibial hyaline cartilage. Five DECT parameters were obtained: CT numbers in Hounsfield units (HU) at 80 and 140 kV, the electron density (Rho), the effective atomic number (Zeff), and the dual-energy index (DEI). Zones were compared between patients with gout, with and without knee OA, and between patients with gout and comparators without gout, after adjustment for confounders. RESULTS: A total of 113 patients with gout (mean age 63.5 ± 14.3 years) and 15 comparators without gout (mean age 75.8 ± 11.5 years) were included, n = 65 (51%) had knee OA, and 466 zones of hyaline cartilage were analyzed. Older age was associated with lower attenuations at 80 kV (P < 0.01) and 140 kV (P < 0.01), and with Rho (P < 0.01). OA was characterized by lower attenuation at 140 kV (P = 0.03), but the lower Rho was nonsignificant after adjustment for confounders. In gout, hyaline cartilage exhibited lower Rho values (adjusted P = 0.04). Multivariable coefficients of association with Rho were -0.21 [-0.38;-0.04] (P = 0.014) for age, -4.15 [-9.0;0.7] (P = 0.093) for OA and 0.73 [-0.1;1.56] (P = 0.085) for monosodium urate volume. CONCLUSION: Gout was associated with DECT-detected changes in cartilage composition, similar to those observed in older patients, with some similarities and some differences to those seen in OA. These results suggest the possibility of potential DECT biomarkers of OA.

5.
Arthritis Care Res (Hoboken) ; 75(4): 825-834, 2023 04.
Article in English | MEDLINE | ID: mdl-35439343

ABSTRACT

OBJECTIVE: To develop definitions for imaging features being considered as potential classification criteria for calcium pyrophosphate deposition (CPPD) disease, additional to clinical and laboratory criteria, and to compile example images of CPPD on different imaging modalities. METHODS: The American College of Rheumatology and European Alliance of Associations for Rheumatology CPPD classification criteria Imaging Advisory Group (IAG) and Steering Committee drafted definitions of imaging features that are characteristic of CPPD on conventional radiography (CR), conventional computed tomography (CT), dual-energy CT (DECT), and magnetic resonance imaging (MRI). An anonymous expert survey was undertaken by a 35-member Combined Expert Committee, including all IAG members. The IAG and 5 external musculoskeletal radiologists with expertise in CPPD convened virtually to further refine item definitions and voted on example images illustrating CR, CT, and DECT item definitions, with ≥90% agreement required to deem them acceptable. RESULTS: The Combined Expert Committee survey indicated consensus on all CR definitions. The IAG and external radiologists reached consensus on CT and DECT item definitions, which specify that calcium pyrophosphate deposits appear less dense than cortical bone. The group developed an MRI definition and acknowledged limitations of this modality for CPPD. Ten example images for CPPD were voted acceptable (4 CR, 4 CT, and 2 DECT), and 3 images of basic calcium phosphate deposition were voted acceptable to serve as contrast against imaging features of CPPD. CONCLUSION: An international group of rheumatologists and musculoskeletal radiologists defined imaging features characteristic of CPPD on CR, CT, and DECT and assembled a set of example images as a reference for future clinical research studies.


Subject(s)
Calcinosis , Chondrocalcinosis , Humans , Chondrocalcinosis/diagnostic imaging , Calcium Pyrophosphate , Consensus , Radiography
6.
Lancet Rheumatol ; 5(9): e523-e531, 2023 Sep.
Article in English | MEDLINE | ID: mdl-38251496

ABSTRACT

BACKGROUND: Acute calcium pyrophosphate crystal arthritis causes intense joint pain mainly affecting older people. Because guidance and evidence remain scarce, management of this disease relies on expert opinion. We therefore aimed to compare the safety and short-term equivalence of low-dose colchicine with oral prednisone in older patients with acute calcium pyrophosphate crystal arthritis. METHODS: We did an open-label, multicentre, randomised, trial (COLCHICORT) at six hospitals in Paris and northern France. We enrolled patients who were admitted to hospital who were 65 years or older and who presented with acute calcium pyrophosphate crystal arthritis with a symptom duration of less than 36 h. Diagnosis of calcium pyrophosphate crystal arthritis was made by the identification of calcium pyrophosphate crystals on synovial fluid analysis or typical clinical presentation (onset of joint pain and swelling). Key exclusion criteria included absence of calcium pyrophosphate crystals on synovial fluid analysis or a history of gout. Participants were randomly allocated (1:1), using a centralised electronic treatment group allocation module, to receive either colchicine 1·5 mg on day 1 and 1 mg on day 2 (ie, the colchicine group) or oral prednisone 30 mg on days 1 and 2 (ie, the prednisone group). The primary outcome was change in joint pain (measured by visual analogue scale [VAS] from 0 mm to 100 mm) at 24 h. Equivalence was determined whether the 95% CI of the between-group difference at 24 h was within the -13 mm to +13 mm margin in the per-protocol analysis. Adverse events were recorded using the National Cancer Institute Common Terminology Criteria for Adverse Events (version 4.0). This trial is completed and is registered with ClinicalTrials.gov, NCT03128905. FINDINGS: Between Feb 5, 2018, and May 7, 2022, 111 patients who were admitted to hospital were randomly assigned (57 [51%] to the colchicine group and 54 [49%] to the prednisone group). 95 (86%) of 111 patients were included in the per-protocol analysis (49 [52%] in the colchicine group and 46 [48%] in the prednisone group). The median age was 88·0 years (IQR 82·0-91·0) and 69 (73%) of 95 participants were women and 26 (27%) were men. Acute calcium pyrophosphate crystal arthritis affected mainly the knee in 46 (48%) of 95 participants, the wrist in 19 (20%), and the ankle in 12 (13%). Pain VAS at baseline was 68 mm (SD 17). At 24 h, change in pain VAS was -36 mm (SD 32) in the colchicine group and -38 mm (SD 23) in the prednisone group. The between-group difference in change in pain VAS at 24 h was -1 mm (95% CI -12 to 10), showing equivalence between the two drugs. In the colchicine group, 12 (22%) of 55 patients had diarrhoea, one (2%) had hypertension, and none had hyperglycaemia. In the prednisone group, three (6%) of 54 had diarrhoea, six (11%) had hypertension, and three (6%) had hyperglycaemia. No deaths occurred in the colchicine group; two deaths occurred in the prednisone group, which were deemed unrelated to prednisone (one due to infectious valvular endocarditis leading to heart failure, and one due to a stroke). INTERPRETATION: Colchicine and prednisone exhibit equivalent short-term efficacy for the treatment of acute calcium pyrophosphate crystal arthritis, with different safety profiles in the older population. FUNDING: French Inter-regional Hospital Program of Clinical Research.


Subject(s)
Gout , Hyperglycemia , Hypertension , Male , Humans , Female , Aged , Aged, 80 and over , Colchicine/adverse effects , Calcium Pyrophosphate , Prednisone/adverse effects , Arthralgia , Diarrhea
7.
Foot Ankle Surg ; 28(7): 1076-1082, 2022 Oct.
Article in English | MEDLINE | ID: mdl-35346595

ABSTRACT

INTRODUCTION: The too-long anterior process (TLAP) increases mechanical stress on the hindfoot and could lead to osteochondral lesions of the talus (OLT) by localized hyper-pressure. The purpose of this study is to investigate an association between TLAP and OLT in children. METHODS: This is a retrospective, multicenter, case-control study conducted between 2010 and 2020. The OLT group was compared to a control group (CoG). TLAP is characterized by a distance between the anteromedial process of the calcaneus and the navicular bone (CN) of< 5 mm. RESULTS: Forty-three feets were included in the OLT group and 92 in the CoG. The OLT group had a lower CN distance on CT than the CoG, a median of 2.8 mm versus 3.75 mm (p = 0.002); 86% of patients (37 feet/43) in the OLT group had a CN distance of< 5 mm (OR=3.0 [1.1; 9.5], p = 0.023) compared to 67% in the CoG. DISCUSSION: The OLT group had an increased risk of developing TLAP compared to the CoG. LEVEL OF EVIDENCE: III.


Subject(s)
Calcaneus , Talus , Case-Control Studies , Child , Humans , Magnetic Resonance Imaging , Retrospective Studies , Talus/surgery
8.
Curr Opin Rheumatol ; 34(2): 103-110, 2022 03 01.
Article in English | MEDLINE | ID: mdl-35034071

ABSTRACT

PURPOSE OF REVIEW: To give an overview of what can reasonably be considered as known about dual-energy computed tomography (DECT) in crystal-related arthropathies, and what still needs to be explored. RECENT FINDINGS: Recent studies suggest an overall superiority of DECT over ultrasound in gout in terms of sensitivity (89 vs. 84%) and specificity (91 vs. 84%), except in early disease. Additional studies are needed to optimize DECT postprocessing settings in order to improve the specificity of the technique and eliminate all artifacts. Evidence has been controversial concerning DECT's ability to detect monosodium urate (MSU) crystal deposits on vessel walls, or whether or not MSU-coded plaques are artifacts. DECT can be used to monitor MSU crystal depletion during urate-lowering treatment; MSU crystal volume is associated with cardiovascular risk and disease activity. There are some reports on calcium-containing crystal deposition diseases (calcium pyrophosphate and basic calcium phosphate) demonstrating that DECT can characterize and discriminate between the different types of crystals. SUMMARY: Our knowledge about the use of DECT in crystal-related arthropathies continues to expand. Some unknowns have been clarified but there's still lots to learn, particularly concerning gout management and the potential use of DECT in calcium-containing crystal-related arthropathies.


Subject(s)
Gout , Tomography, X-Ray Computed , Calcium Pyrophosphate , Gout/diagnostic imaging , Humans , Ultrasonography , Uric Acid
9.
Semin Arthritis Rheum ; 51(4): 895-902, 2021 08.
Article in English | MEDLINE | ID: mdl-34198148

ABSTRACT

OBJECTIVE: To characterize peripheral vascular plaques color-coded as monosodium urate (MSU) deposition by dual-energy computed tomography (DECT) and assess their association with the overall soft-tissue MSU crystal burden. METHODS: Patients with suspected crystal arthropathies were prospectively included in the CRYSTALILLE inception cohort to undergo baseline knees and ankles/feet DECT scans; treatment-naive gout patients initiating treat-to-target urate-lowering therapy (ULT) underwent repeated DECT scans with concomitant serum urate level measurements at 6 and 12 months. We determined the prevalence of DECT-based vascular MSU-coded plaques in knee arteries, and assessed their association with the overall DECT volumes of soft-tissue MSU crystal deposition and coexistence of arterial calcifications. DECT attenuation parameters of vascular MSU-coded plaques were compared with dense calcified plaques, control vessels, control soft tissues, and tophi. RESULTS: We investigated 126 gout patients and 26 controls; 17 ULT-naive gout patients were included in the follow-up study. The prevalence of DECT-based vascular MSU-coded plaques was comparable in gout patients (24.6%) and controls (23.1%; p=0.87). Vascular MSU-coded plaques were strongly associated with coexisting arterial calcifications (p<0.001), but not with soft-tissue MSU deposition. Characterization of vascular MSU-coded plaques revealed specific differences in DECT parameters compared with control vessels, control soft tissues, and tophi. During follow-up, vascular MSU-coded plaques remained stable despite effective ULT (p=0.64), which decreased both serum urate levels and soft-tissue MSU volumes (p<0.001). CONCLUSION: Our findings suggest that DECT-based MSU-coded plaques in peripheral arteries are strongly associated with calcifications and may not reflect genuine MSU crystal deposition. Such findings should therefore not be a primary target when managing gout patients.


Subject(s)
Arthritis, Gouty , Gout , Follow-Up Studies , Gout/diagnostic imaging , Gout/drug therapy , Humans , Tomography, X-Ray Computed , Uric Acid
12.
Rheumatology (Oxford) ; 60(10): 4855-4860, 2021 10 02.
Article in English | MEDLINE | ID: mdl-33410483

ABSTRACT

OBJECTIVES: To determine whether the volume of monosodium urate (MSU) crystal deposition measured with dual-energy CT (DECT) is predictive of short-term mortality and development of cardiovascular comorbidities and diabetes mellitus. METHODS: Patients with a diagnosis of gout having had baseline DECT scans of their knees and feet to measure the volume of MSU crystal deposition were included to undergo a follow-up visit. Risk factors for mortality and a composite variable (onset of any cardio-metabolic event) were examined using multivariable Cox models. RESULTS: A total of 128 patients aged 66.1 (14.0) years with gout durations of 11.4 (10.4) years were included; most were naïve of urate lowering therapy (61.7%), with a follow-up visit at 24 (12, 36) months. Baseline serum urate (SU) level was 7.44 (2.29) mg/dl and DECT volume of MSU crystals was 0.2 (0, 0.9) cm3. A total of 14 patients died during follow-up, 6/14 from a cardiovascular cause, and 17 patients presented a new cardio-metabolic comorbidity. Factors associated with mortality risk were baseline DECT volume of MSU crystals [hazard ratio (HR) 1.02, 95% CI: 1.002, 1.03] and baseline SU level (HR 1.04, 95% CI: 1.003, 1.06). DECT volume of MSU crystals was the only factor associated with the onset of cardio-metabolic comorbidities with a HR of 1.014 (95% CI: 1.001, 1.03). CONCLUSIONS: Volume of MSU crystals measured with DECT is a biomarker for the risk of developing new cardio-metabolic diseases and for all-cause mortality.


Subject(s)
Cardiovascular Diseases/etiology , Gout/diagnostic imaging , Aged , Gout/complications , Gout/mortality , Gout/pathology , Humans , Risk Factors , Tomography, X-Ray Computed , Uric Acid/metabolism
13.
Rheumatology (Oxford) ; 60(10): 4861-4867, 2021 10 02.
Article in English | MEDLINE | ID: mdl-33410491

ABSTRACT

OBJECTIVE: To examine the accuracy of dual-energy CT (DECT) vs ultrasound or their combination for the diagnosis of gout. METHODS: Using prospectively collected data from an outpatient rheumatology clinic at a tertiary-care hospital, we examined the diagnostic accuracy of either modality alone or their combination, by anatomical site (feet/ankles and/or knees), for the diagnosis of gout. We used two standards: (i) demonstration of monosodium urate crystals in synovial fluid (gold), and (ii) modified (excluding DECT and ultrasound) 2015 ACR-EULAR gout classification criteria (silver). RESULTS: Of the 147 patients who provided data, 48 (33%) had synovial fluid analysis performed (38 were monosodium urate-crystal positive) and mean symptom duration was 9.2 years. One hundred (68%) patients met the silver standard. Compared with the gold standard, diagnostic accuracy statistics for feet/ankles DECT, feet/ankles ultrasound, knees DECT and knees ultrasound were, respectively: sensitivity: 87%, 84%, 91% and 58%; specificity: 100%, 60%, 87% and 80%; positive predictive value: 100%, 89%, 97% and 92%; negative predictive value: 67%, 50%, 70% and 33%; area under the receiver operating characteristic curve: 0.93, 0.72, 0.89 and 0.66. Combining feet/ankles DECT with ultrasound or knees DECT with ultrasound led to a numerically higher sensitivity compared with DECT alone, but overall accuracy was lower. Similarly, combining imaging knees to feet/ankles also yielded a numerically higher sensitivity and negative predictive values compared with feet/ankles DECT alone, without differences in overall accuracy. Findings were replicated compared with the silver standard, but with lower numbers. CONCLUSIONS: Feet/ankles or knees DECT alone had the best overall accuracy for gout diagnosis. The DECT-US combination or multiple joint imaging offered no additional increase in overall diagnostic accuracy.


Subject(s)
Gout/diagnostic imaging , Tomography, X-Ray Computed , Ultrasonography , Adult , Aged , Female , Gout/diagnosis , Humans , Male , Middle Aged , Prospective Studies , Reproducibility of Results , Sensitivity and Specificity , Tomography, X-Ray Computed/methods , Ultrasonography/methods
14.
Arthritis Rheumatol ; 73(4): 687-692, 2021 04.
Article in English | MEDLINE | ID: mdl-33131218

ABSTRACT

OBJECTIVE: To assess the ability of dual-energy computed tomography (DECT) in identifying early calcium crystal deposition in menisci and articular cartilage of the knee, depending on the presence/absence of chondrocalcinosis seen on conventional CT. METHODS: One hundred thirty-two knee DECT scans from patients with suspected crystal-associated arthropathy were reviewed and assigned to a calcium pyrophosphate deposition (CPPD) group (n = 50) or a control group (n = 82). Five DECT attenuation parameters were measured in preset regions of interest (ROIs) in menisci and articular cartilage and compared between groups using linear mixed models with adjustment for confounders. Subgroup analysis, excluding ROIs with chondrocalcinosis seen on conventional CT, was performed. RESULTS: In both menisci and articular cartilage, and for all 5 DECT attenuation parameters, calcified ROIs in CPPD patients showed significantly higher values than ROIs in controls (P ≤ 0.036). Conversely, noncalcified ROIs in CPPD patients were comparable with those in controls (P ≥ 0.09). While specific DECT parameters yielded good accuracy (area under the curve [AUC] 0.87-0.88) in differentiating calcified ROIs in CPPD patients from ROIs in controls, DECT failed to distinguish between noncalcified ROIs in CPPD patients and controls (AUC 0.58-0.59). CONCLUSION: While DECT has the potential to characterize knee intraarticular mineralization, this technique cannot yet accurately identify early calcium crystal deposition that is not visible as chondrocalcinosis on conventional CT.


Subject(s)
Cartilage, Articular/diagnostic imaging , Chondrocalcinosis/diagnostic imaging , Knee Joint/diagnostic imaging , Menisci, Tibial/diagnostic imaging , Adult , Aged , Aged, 80 and over , Calcium Pyrophosphate , Cross-Sectional Studies , Early Diagnosis , Female , Humans , Male , Middle Aged , Tomography, X-Ray Computed/methods
15.
Eur J Radiol ; 131: 109206, 2020 Oct.
Article in English | MEDLINE | ID: mdl-32871293

ABSTRACT

PURPOSE: To describe bone perfusion and adiposity beyond the necrotic zone with quantitative MRI techniques in osteonecrosis of the femoral head (ONFH). METHOD: In this cross-sectional multicentre study, we recruited patients suffering from late-stage ONFH or hip osteoarthritis. Hip MRI included quantitative MRI sequences: chemical-shift imaging and dynamic contrast-enhanced MRI. We drew regions of interest inside the necrotic zone (inner necrosis and its border) and outside (femoral head, neck and greater trochanter) in ONFH. In the control group, regions of interest were drawn in the femoral head, femoral neck and the greater trochanter. For each region of interest, we measured fat fraction, and calculated semi-quantitative (area under the curve, initial slope) and pharmacokinetic perfusion parameters (Ktrans and Kep). RESULTS: Thirty-two male adults (mean age 58 ±â€¯9 years, range 38-74 years) were included. Sixteen patients formed the ONFH group and fifteen the control group; one was excluded. In the normal-appearing non-necrotic part of the femoral head, fat fraction was not significantly different in comparison with controls (p = 1), but Ktrans was significantly lower than in controls (0.012 ±â€¯0.018 vs. 0.027 ±â€¯0.045; p = 0.05). This perfusion parameter reflects exchanges between blood microvessels and bone marrow. CONCLUSIONS: Our results question the concept of adipose toxicity on the macroscopic scale, and bring up the concept of regional ischemic penumbra that goes beyond the visible necrotic zone. Further studies are required to test these hypotheses in larger populations and earlier disease states.


Subject(s)
Adiposity , Femur Head Necrosis/diagnostic imaging , Femur Head/blood supply , Magnetic Resonance Imaging , Adult , Aged , Area Under Curve , Body Mass Index , Bone Marrow/blood supply , Bone Marrow/diagnostic imaging , Bone Marrow/pathology , Cross-Sectional Studies , Femur/blood supply , Femur/diagnostic imaging , Femur Head/diagnostic imaging , Femur Head/pathology , Femur Head Necrosis/pathology , Femur Head Necrosis/physiopathology , Humans , Magnetic Resonance Imaging/methods , Male , Middle Aged , Osteoarthritis, Hip/diagnostic imaging
16.
Ther Adv Musculoskelet Dis ; 12: 1759720X20936060, 2020.
Article in English | MEDLINE | ID: mdl-32636945

ABSTRACT

BACKGROUND: Dual-energy computed tomography (DECT) is being considered as a non-invasive diagnostic and characterization tool in calcium crystal-associated arthropathies. Our objective was to assess the potential of DECT in distinguishing between basic calcium phosphate (BCP) and calcium pyrophosphate (CPP) crystal deposition in and around joints in vivo. METHODS: A total of 13 patients with calcific periarthritis and 11 patients with crystal-proven CPPD were recruited prospectively to undergo DECT scans. Samples harvested from BCP and CPP calcification types were analyzed using Raman spectroscopy and validated against synthetic crystals. Regions of interest were placed in BCP and CPP calcifications, and the following DECT attenuation parameters were obtained: CT numbers (HU) at 80 and 140 kV, dual-energy index (DEI), electron density (Rho), and effective atomic number (Z eff). These DECT attenuation parameters were compared and validated against crystal calibration phantoms at two known equal concentrations. Receiver operating characteristic (ROC) curves were plotted to determine the highest accuracy thresholds for DEI and Z eff. RESULTS: Raman spectroscopy enabled chemical fingerprinting of BCP and CPP crystals both in vitro and in vivo. DECT was able to distinguish between HA and CPP in crystal calibration phantoms at two known equal concentrations, most notably by DEI (200 mg/cm3: 0.037 ± 0 versus 0.034 ± 0, p = 0.008) and Z eff (200 mg /cm3: 9.4 ± 0 versus 9.3 ± 0, p = 0.01) analysis. Likewise, BCP calcifications had significantly higher DEI (0.041 ± 0.005 versus 0.034 ± 0.005, p = 0.008) and Z eff (9.5 ± 0.2 versus 9.3 ± 0.2, p = 0.03) than CPP crystal deposits with comparable CT numbers in patients. With an area under the ROC curve of 0.83 [best threshold value = 0.0 39, sensitivity = 90. 9% (81.8, 97. 7%), specificity = 64.6% (50.0, 64. 6%)], DEI was the best parameter in distinguishing between BCP and CPP crystal depositions. CONCLUSION: DECT can help distinguish between crystal-proven BCP and CPP calcification types in vivo and, thus, aid in the diagnosis of challenging clinical cases, and in the characterization of CPP and BCP crystal deposition occurring in osteoarthritis.

18.
J Clin Med ; 9(5)2020 May 01.
Article in English | MEDLINE | ID: mdl-32369943

ABSTRACT

(1) Background: To determine which factors are associated with the volume of monosodium urate (MSU) crystal deposition quantified by dual-energy computed tomography (DECT) in urate-lowering therapy (ULT)-naive gout patients. (2) Methods: In this multicenter cross-sectional study, DECT scans of knees and feet/ankles were prospectively obtained from ULT-naive gout patients. Demographic, clinical (including gout history and comorbidities), and biological data were collected, and their association with DECT MSU crystal volume was analyzed using bivariate and multivariate analyses. A second bivariate analysis was performed by splitting the dataset depending on an arbitrary threshold of DECT MSU volume (1 cm3). (3) Results: A total of 91 patients were included. In the bivariate analysis, age (p = 0.03), gout duration (p = 0.003), subcutaneous tophi (p = 0.004), hypertension (p = 0.02), diabetes mellitus (p = 0.05), and chronic heart failure (p = 0.03) were associated with the total DECT volume of MSU crystal deposition. In the multivariate analysis, factors associated with DECT MSU volumes ≥1 cm3 were gout duration (odds ratio (OR) for each 10-year increase 3.15 (1.60; 7.63)), diabetes mellitus (OR 4.75 (1.58; 15.63)), and chronic heart failure (OR 7.82 (2.29; 31.38)). (4) Conclusion: Specific comorbidities, particularly chronic heart failure and diabetes mellitus, are more strongly associated with increased MSU crystal deposition in knees and feet/ankles than gout duration, regardless of serum urate level.

19.
Bone ; 130: 115099, 2020 01.
Article in English | MEDLINE | ID: mdl-31654780

ABSTRACT

The potency of magnetic resonance imaging (MRI) to measure the exact extent of osteonecrosis of the femoral head (ONFH) remains uncertain. The objective of this study was to determine if the volume of necrosis assessed with MRI accurately reflects the volume of architectural mineral alterations in osteonecrosis of the femoral head by comparison with high-resolution microfocus X-ray computed tomography (HR-µCT). Fourteen male patients aged 53 years [46.2;59.0] suffering from ONFH were prospectively enrolled to undergo preoperative MRI and ex vivo analysis using HR-µCT. The necrotic zone on T1-weighted MRI scans was defined as total necrosis (delimited by the low-signal peripheral band) or dark necrosis (low-signal lesions only). The HR-µCT scans delimited outer necrosis and inner necrosis by including or excluding the sclerotic zone. The intra-class correlation coefficient (ICC) was calculated to compare the agreement of surface areas and volumes of necrosis measurements with the two techniques. There was an overall excellent agreement between MRI dark necrosis volume and HR-µCT outer necrosis volume (ICC=0.91[0.54;0.98]) while the MRI total necrosis volume showed poor agreement with both HR-µCT delimitations of necrosis volume. For surface area, agreement between MRI dark necrosis and HR-µCT delimitations was good for inner necrosis (ICC=0.70[0.21;0.9]) and moderate for outer necrosis (ICC=0.58[0.07;0.85]). This study demonstrates that measurement of the MRI lesions provides a reliable assessment of the extent of ONFH-related architectural damage.


Subject(s)
Femur Head Necrosis , Femur Head , Femur Head/diagnostic imaging , Femur Head Necrosis/diagnostic imaging , Humans , Magnetic Resonance Imaging , Male , Minerals , Tomography, X-Ray Computed
SELECTION OF CITATIONS