Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Circulation ; 148(23): 1847-1856, 2023 12 05.
Article in English | MEDLINE | ID: mdl-37952192

ABSTRACT

BACKGROUND: Few studies have measured ventilation during early cardiopulmonary resuscitation (CPR) before advanced airway placement. Resuscitation guidelines recommend pauses after every 30 chest compressions to deliver ventilations. The effectiveness of bag-valve-mask ventilation delivered during the pause in chest compressions is unknown. We sought to determine: (1) the incidence of lung inflation with bag-valve-mask ventilation during 30:2 CPR; and (2) the association of ventilation with outcomes after out-of-hospital cardiac arrest. METHODS: We studied patients with out-of-hospital cardiac arrest from 6 sites of the Resuscitation Outcomes Consortium CCC study (Trial of Continuous Compressions versus Standard CPR in Patients with Out-of-Hospital Cardiac Arrest). We analyzed patients assigned to the 30:2 CPR arm with ≥2 minutes of thoracic bioimpedance signal recorded with a cardiac defibrillator/monitor. Detectable ventilation waveforms were defined as having a bioimpedance amplitude ≥0.5 Ω (corresponding to ≥250 mL VT) and a duration ≥1 s. We defined a chest compression pause as a 3- to 15-s break in chest compressions. We compared the incidence of ventilation and outcomes in 2 groups: patients with ventilation waveforms in <50% of pauses (group 1) versus those with waveforms in ≥50% of pauses (group 2). RESULTS: Among 1976 patients, the mean age was 65 years; 66% were male. From the start of chest compressions until advanced airway placement, mean±SD duration of 30:2 CPR was 9.8±4.9 minutes. During this period, we identified 26 861 pauses in chest compressions; 60% of patients had ventilation waveforms in <50% of pauses (group 1, n=1177), and 40% had waveforms in ≥50% of pauses (group 2, n=799). Group 1 had a median of 12 pauses and 2 ventilations per patient versus group 2, which had 12 pauses and 12 ventilations per patient. Group 2 had higher rates of prehospital return of spontaneous circulation (40.7% versus 25.2%; P<0.0001), survival to hospital discharge (13.5% versus 4.1%; P<0.0001), and survival with favorable neurological outcome (10.6% versus 2.4%; P<0.0001). These associations persisted after adjustment for confounders. CONCLUSIONS: In this study, lung inflation occurred infrequently with bag-valve-mask ventilation during 30:2 CPR. Lung inflation in ≥50% of pauses was associated with improved return of spontaneous circulation, survival, and survival with favorable neurological outcome.


Subject(s)
Cardiopulmonary Resuscitation , Out-of-Hospital Cardiac Arrest , Humans , Male , Aged , Female , Out-of-Hospital Cardiac Arrest/therapy , Respiration, Artificial/adverse effects , Pressure , Thorax
2.
Physiol Genomics ; 53(1): 1-11, 2021 01 01.
Article in English | MEDLINE | ID: mdl-33197228

ABSTRACT

Comprehensive and spatially mapped molecular atlases of organs at a cellular level are a critical resource to gain insights into pathogenic mechanisms and personalized therapies for diseases. The Kidney Precision Medicine Project (KPMP) is an endeavor to generate three-dimensional (3-D) molecular atlases of healthy and diseased kidney biopsies by using multiple state-of-the-art omics and imaging technologies across several institutions. Obtaining rigorous and reproducible results from disparate methods and at different sites to interrogate biomolecules at a single-cell level or in 3-D space is a significant challenge that can be a futile exercise if not well controlled. We describe a "follow the tissue" pipeline for generating a reliable and authentic single-cell/region 3-D molecular atlas of human adult kidney. Our approach emphasizes quality assurance, quality control, validation, and harmonization across different omics and imaging technologies from sample procurement, processing, storage, shipping to data generation, analysis, and sharing. We established benchmarks for quality control, rigor, reproducibility, and feasibility across multiple technologies through a pilot experiment using common source tissue that was processed and analyzed at different institutions and different technologies. A peer review system was established to critically review quality control measures and the reproducibility of data generated by each technology before their being approved to interrogate clinical biopsy specimens. The process established economizes the use of valuable biopsy tissue for multiomics and imaging analysis with stringent quality control to ensure rigor and reproducibility of results and serves as a model for precision medicine projects across laboratories, institutions and consortia.


Subject(s)
Guidelines as Topic , Kidney/pathology , Precision Medicine , Biopsy , Humans , Reproducibility of Results
SELECTION OF CITATIONS
SEARCH DETAIL
...