Int J Numer Method Biomed Eng ; : e3853, 2024 Aug 01.
Article in English | MEDLINE | ID: mdl-39090842

ABSTRACT

The effectiveness of various stroke treatments depends on the anatomical variability of the cerebral vasculature, particularly the collateral blood vessel network. Collaterals at the level of the Circle of Willis and distal collaterals, such as the leptomeningeal arteries, serve as alternative avenues of flow when the primary pathway is obstructed during an ischemic stroke. Stroke treatment typically involves catheterization of the primary pathway, and the potential risk of further flow reduction to the affected brain area during this treatment has not been previously investigated. To address this clinical question, we derived the lumped parameters for catheterized blood vessels and implemented a corresponding distributed compartment (0D) model. This 0D model was validated against an experimental model and benchmark test cases solved using a 1D model. Additionally, we compared various off-center catheter trajectories modeled using a 3D solver to this 0D model. The differences between them were minimal, validating the simplifying assumption of the central catheter placement in the 0D model. The 0D model was then used to simulate blood flows in realistic cerebral arterial networks with different collateralization characteristics. Ischemic strokes were modeled by occlusion of the M1 segment of the middle cerebral artery in these networks. Catheters of different diameters were inserted up to the obstructed segment and flow alterations in the network were calculated. Results showed up to 45% maximum blood flow reduction in the affected brain region. These findings suggest that catheterization during stroke treatment may have a further detrimental effect for some patients with poor collateralization.

2.
Int J Numer Method Biomed Eng ; : e3844, 2024 Jul 01.
Article in English | MEDLINE | ID: mdl-38952068

ABSTRACT

Intracranial aneurysms (IAs) pose severe health risks influenced by hemodynamics. This study focuses on the intricate characterization of hemodynamic conditions within the IA walls and their influence on bleb development, aiming to enhance understanding of aneurysm stability and the risk of rupture. The methods emphasized utilizing a comprehensive dataset of 359 IAs and 213 IA blebs from 268 patients to reconstruct patient-specific vascular models, analyzing blood flow using finite element methods to solve the unsteady Navier-Stokes equations, the segmentation of aneurysm wall subregions and the hemodynamic metrics wall shear stress (WSS), its metrics, and the critical points in WSS fields were computed and analyzed across different aneurysm subregions defined by saccular, streamwise, and topographical divisions. The results revealed significant variations in these metrics, correlating distinct hemodynamic environments with wall features on the aneurysm walls, such as bleb formation. Critical findings indicated that regions with low WSS and high OSI, particularly in the body and central regions of aneurysms, are prone to conditions that promote bleb formation. Conversely, areas exposed to high WSS and positive divergence, like the aneurysm neck, inflow, and outflow regions, exhibited a different but substantial risk profile for bleb development, influenced by flow impingements and convergences. These insights highlight the complexity of aneurysm behavior, suggesting that both high and low-shear environments can contribute to aneurysm pathology through distinct mechanisms.

3.
J Neurosurg ; : 1-8, 2024 Jul 12.
Article in English | MEDLINE | ID: mdl-38996402

ABSTRACT

OBJECTIVE: Fibrin deposition represents a key step in aneurysm occlusion, promoting endothelization of implants and connective tissue organization as part of the aneurysm-healing mechanism. In this study, the authors introduce a novel in vitro testing platform for flow diverters based on human fibrinogen. METHODS: A flow diverter was deployed in 4 different glass models. The glass models had the same internal parent artery (4 mm) and aneurysm (8 mm) diameters with varying parent artery angulations (paraophthalmic, sidewall, bifurcation, and slightly curved models). The neck size and area were 4 mm and 25 mm2, respectively. Human fibrinogen (330 mg/dl) was circulated within the glass models at varying flow rates (0, 3, 4, and 5 ml/sec) with or without heparin, calcium chloride, and thrombin for as long as 6 hours or until complete fibrin coverage of the flow diverter's neck was achieved. Aneurysm neck coverage was defined as macroscopic fibrin deposition occluding the flow diverters' pores. Flow characteristics after flow diverter deployment were assessed with computational fluid dynamics analysis. The effects of flow rates, heparin, calcium chloride, and thrombin on fibrin deposition rates were tested using 1-way ANOVA and the Tukey test. RESULTS: A total of 84 replicates were performed. Human fibrin did not accumulate on the flow diverter stents under static conditions. The fibrin deposition rate on the aneurysm neck was significantly greater with the 5 ml/sec flow rate as compared to 3 ml/sec for all models. The paraophthalmic model had the highest inflow velocity of 48.7 cm/sec. The bifurcation model had the highest maximum shear stress (SS) and maximum normalized shear stress values at the device cells at 843.3 dyne/cm2 and 35.1 SS/SSinflow, respectively. The fibrin deposition rates of the paraophthalmic and bifurcation models were significantly higher than those of sidewall and slightly curved models for all additive or flow rate comparisons (p = 0.001 for all comparisons). The incorporation of thrombin significantly increased the fibrin deposition rates across all models (p = 0.001 for all models). CONCLUSIONS: Rates of fibrin deposition varied widely across different configurations and additive conditions in this novel in vitro model system. Fibrin accumulation started at the aneurysm inflow zone where flow velocity and shear stress were the highest. The primary factors influencing fibrin deposition included flow velocities, shear stress, and the addition of thrombin at a physiological concentration. Further research is needed to test the clinical utility of fibrinogen-based models for patient-specific aneurysms.

4.
Int J Numer Method Biomed Eng ; : e3837, 2024 Jun 05.
Article in English | MEDLINE | ID: mdl-38839043

ABSTRACT

The mechanisms behind intracranial aneurysm formation and rupture are not fully understood, with factors such as location, patient demographics, and hemodynamics playing a role. Additionally, the significance of anatomical features like blebs in ruptures is debated. This highlights the necessity for comprehensive research that combines patient-specific risk factors with a detailed analysis of local hemodynamic characteristics at bleb and rupture sites. Our study analyzed 359 intracranial aneurysms from 268 patients, reconstructing patient-specific models for hemodynamic simulations based on 3D rotational angiographic images and intraoperative videos. We identified aneurysm subregions and delineated rupture sites, characterizing blebs and their regional overlap, employing statistical comparisons across demographics, and other risk factors. This work identifies patterns in aneurysm rupture sites, predominantly at the dome, with variations across patient demographics. Hypertensive and anterior communicating artery (ACom) aneurysms showed specific rupture patterns and bleb associations, indicating two pathways: high-flow in ACom with thin blebs at impingement sites and low-flow, oscillatory conditions in middle cerebral artery (MCA) aneurysms fostering thick blebs. Bleb characteristics varied with gender, age, and smoking, linking rupture risks to hemodynamic factors and patient profiles. These insights enhance understanding of the hemodynamic mechanisms leading to rupture events. This analysis elucidates the role of localized hemodynamics in intracranial aneurysm rupture, challenging the emphasis on location by revealing how flow variations influence stability and risk. We identify two pathways to wall failure-high-flow and low-flow conditions-highlighting the complexity of aneurysm behavior. Additionally, this research advances our knowledge of how inherent patient-specific characteristics impact these processes, which need further investigation.

5.
Int J Numer Method Biomed Eng ; 40(7): e3834, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38736046

ABSTRACT

Strokes are one of the leading causes of death in the United States. Stroke treatment involves removal or dissolution of the obstruction (usually a clot) in the blocked artery by catheter insertion. A computer simulation to systematically plan such patient-specific treatments needs a network of about 105 blood vessels including collaterals. The existing computational fluid dynamic (CFD) solvers are not employed for stroke treatment planning as they are incapable of providing solutions for such big arterial trees in a reasonable amount of time. This work presents a novel one-dimensional mathematical formulation for blood flow modeling in an elastic blood vessel with a centrally placed rigid catheter. The governing equations are first-order hyperbolic partial differential equations, and the hypergeometric function needs to be computed to obtain the characteristic system of these hyperbolic equations. We employed the Discontinuous Galerkin method to solve the hyperbolic system and validated the implementation by comparing it against a well-established 3D CFD solver using idealized vessels and a realistic truncated arterial network. The results showed clinically insignificant differences in steady flow cases, with overall variations between 1D and 3D models remaining below 10%. Additionally, the solver accurately captured wave reflection phenomena at domain discontinuities in unsteady cases. A primary advantage of this model over 3D solvers is its ease in obtaining a discretized geometry of complex vasculatures with multiple arterial branches. Thus, the 1D computational model offers good accuracy and applicability in simulating complex vasculatures, demonstrating promising potential for investigating patient-specific endovascular interventions in strokes.


Subject(s)
Catheters , Computer Simulation , Models, Cardiovascular , Humans , Hydrodynamics , Hemodynamics/physiology , Blood Flow Velocity/physiology , Stroke/physiopathology
6.
Microsc Microanal ; 30(2): 342-358, 2024 Apr 29.
Article in English | MEDLINE | ID: mdl-38525887

ABSTRACT

Deviation of blood flow from an optimal range is known to be associated with the initiation and progression of vascular pathologies. Important open questions remain about how the abnormal flow drives specific wall changes in pathologies such as cerebral aneurysms where the flow is highly heterogeneous and complex. This knowledge gap precludes the clinical use of readily available flow data to predict outcomes and improve treatment of these diseases. As both flow and the pathological wall changes are spatially heterogeneous, a crucial requirement for progress in this area is a methodology for acquiring and comapping local vascular wall biology data with local hemodynamic data. Here, we developed an imaging pipeline to address this pressing need. A protocol that employs scanning multiphoton microscopy was developed to obtain three-dimensional (3D) datasets for smooth muscle actin, collagen, and elastin in intact vascular specimens. A cluster analysis was introduced to objectively categorize the smooth muscle cells (SMC) across the vascular specimen based on SMC actin density. Finally, direct quantitative comparison of local flow and wall biology in 3D intact specimens was achieved by comapping both heterogeneous SMC data and wall thickness to patient-specific hemodynamic results.


Subject(s)
Extracellular Matrix , Hemodynamics , Microscopy, Fluorescence, Multiphoton , Microscopy, Fluorescence, Multiphoton/methods , Myocytes, Smooth Muscle/physiology , Myocytes, Smooth Muscle/cytology , Actins/metabolism , Animals , Collagen/metabolism , Humans , Elastin/metabolism , Elastin/analysis , Imaging, Three-Dimensional/methods , Arteries
7.
ArXiv ; 2024 Jan 17.
Article in English | MEDLINE | ID: mdl-38313202

ABSTRACT

Vascular calcification is implicated as an important factor in major adverse cardiovascular events (MACE), including heart attack and stroke. A controversy remains over how to integrate the diverse forms of vascular calcification into clinical risk assessment tools. Even the commonly used calcium score for coronary arteries, which assumes risk scales positively with total calcification, has important inconsistencies. Fundamental studies are needed to determine how risk is influenced by the diverse calcification phenotypes. However, studies of these kinds are hindered by the lack of high-throughput, objective, and non-destructive tools for classifying calcification in imaging data sets. Here, we introduce a new classification system for phenotyping calcification along with a semi-automated, non-destructive pipeline that can distinguish these phenotypes in even atherosclerotic tissues. The pipeline includes a deep-learning-based framework for segmenting lipid pools in noisy µ-CT images and an unsupervised clustering framework for categorizing calcification based on size, clustering, and topology. This approach is illustrated for five vascular specimens, providing phenotyping for thousands of calcification particles across as many as 3200 images in less than seven hours. Average Dice Similarity Coefficients of 0.96 and 0.87 could be achieved for tissue and lipid pool, respectively, with training and validation needed on only 13 images despite the high heterogeneity in these tissues. By introducing an efficient and comprehensive approach to phenotyping calcification, this work enables large-scale studies to identify a more reliable indicator of the risk of cardiovascular events, a leading cause of global mortality and morbidity.

8.
ArXiv ; 2024 Jan 17.
Article in English | MEDLINE | ID: mdl-37292464

ABSTRACT

Deviation of blood flow from an optimal range is known to be associated with the initiation and progression of vascular pathologies. Important open questions remain about how the abnormal flow drives specific wall changes in pathologies such as cerebral aneurysms where the flow is highly heterogeneous and complex. This knowledge gap precludes the clinical use of readily available flow data to predict outcomes and improve treatment of these diseases. As both flow and the pathological wall changes are spatially heterogeneous, a crucial requirement for progress in this area is a methodology for co-mapping local data from vascular wall biology with local hemodynamic data. In this study, we developed an imaging pipeline to address this pressing need. A protocol that employs scanning multiphoton microscopy was designed to obtain 3D data sets for smooth muscle actin, collagen and elastin in intact vascular specimens. A cluster analysis was developed to objectively categorize the smooth muscle cells (SMC) across the vascular specimen based on SMC density. In the final step in this pipeline, the location specific categorization of SMC, along with wall thickness was co-mapped with patient specific hemodynamic results, enabling direct quantitative comparison of local flow and wall biology in 3D intact specimens.

9.
J Neurointerv Surg ; 16(4): 392-397, 2024 Mar 14.
Article in English | MEDLINE | ID: mdl-37230750

ABSTRACT

BACKGROUND: The presence of blebs increases the rupture risk of intracranial aneurysms (IAs). OBJECTIVE: To evaluate whether cross-sectional bleb formation models can identify aneurysms with focalized enlargement in longitudinal series. METHODS: Hemodynamic, geometric, and anatomical variables derived from computational fluid dynamics models of 2265 IAs from a cross-sectional dataset were used to train machine learning (ML) models for bleb development. ML algorithms, including logistic regression, random forest, bagging method, support vector machine, and K-nearest neighbors, were validated using an independent cross-sectional dataset of 266 IAs. The models' ability to identify aneurysms with focalized enlargement was evaluated using a separate longitudinal dataset of 174 IAs. Model performance was quantified by the area under the receiving operating characteristic curve (AUC), the sensitivity and specificity, positive predictive value, negative predictive value, F1 score, balanced accuracy, and misclassification error. RESULTS: The final model, with three hemodynamic and four geometrical variables, along with aneurysm location and morphology, identified strong inflow jets, non-uniform wall shear stress with high peaks, larger sizes, and elongated shapes as indicators of a higher risk of focal growth over time. The logistic regression model demonstrated the best performance on the longitudinal series, achieving an AUC of 0.9, sensitivity of 85%, specificity of 75%, balanced accuracy of 80%, and a misclassification error of 21%. CONCLUSIONS: Models trained with cross-sectional data can identify aneurysms prone to future focalized growth with good accuracy. These models could potentially be used as early indicators of future risk in clinical practice.


Subject(s)
Aneurysm, Ruptured , Intracranial Aneurysm , Humans , Cross-Sectional Studies , Intracranial Aneurysm/diagnostic imaging , Intracranial Aneurysm/surgery , Hemodynamics , Machine Learning , Aneurysm, Ruptured/surgery
10.
Int J Numer Method Biomed Eng ; 39(11): e3762, 2023 Nov.
Article in English | MEDLINE | ID: mdl-37515447

ABSTRACT

The heterogeneous model developed by Berod et al [Int J Numer Method Biomed Eng 38, 2021] for representing the hemodynamic effects of endovascular prostheses is applied to a series of 10 patient specific cerebral aneurysms, 6 being treated by flow diverters, 4 being equipped with WEBs. Two markers correlated with the medical outcome of the treatment are used to assess the potential of the model, namely the saccular mean velocity and the inflow rate at the neck of the aneurysm. The comparison with the corresponding wire-resolved simulations is very favorable in both cases, and the model-based simulations also retrieve the jetting-type flows generated downstream of the struts. Noteworthy, the very same model was used for representing the flow diverters and the WEBs, showing the versatility and robustness of the heterogeneous modeling of the devices.


Subject(s)
Intracranial Aneurysm , Humans , Intracranial Aneurysm/surgery , Hemodynamics , Stents
11.
Int J Numer Method Biomed Eng ; 39(8): e3740, 2023 08.
Article in English | MEDLINE | ID: mdl-37288602

ABSTRACT

The goal of this study was to test if CFD-based virtual angiograms could be used to automatically discriminate between intracranial aneurysms (IAs) with and without flow stagnation. Time density curves (TDC) were extracted from patient digital subtraction angiography (DSA) image sequences by computing the average gray level intensity inside the aneurysm region and used to define injection profiles for each subject. Subject-specific 3D models were reconstructed from 3D rotational angiography (3DRA) and computational fluid dynamics (CFD) simulations were performed to simulate the blood flow inside IAs. Transport equations were solved numerically to simulate the dynamics of contrast injection into the parent arteries and IAs and then the contrast retention time (RET) was calculated. The importance of gravitational pooling of contrast agent within the aneurysm was evaluated by modeling contrast agent and blood as a mixture of two fluids with different densities and viscosities. Virtual angiograms can reproduce DSA sequences if the correct injection profile is used. RET can identify aneurysms with significant flow stagnation even when the injection profile is not known. Using a small sample of 14 IAs of which seven were previously classified as having flow stagnation, it was found that a threshold RET value of 0.46 s can successfully identify flow stagnation. CFD-based prediction of stagnation was in more than 90% agreement with independent visual DSA assessment of stagnation in a second sample of 34 IAs. While gravitational pooling prolonged contrast retention time it did not affect the predictive capabilities of RET. CFD-based virtual angiograms can detect flow stagnation in IAs and can be used to automatically identify aneurysms with flow stagnation even without including gravitational effects on contrast agents.


Subject(s)
Intracranial Aneurysm , Humans , Intracranial Aneurysm/diagnostic imaging , Contrast Media , Hydrodynamics , Angiography, Digital Subtraction , Hemodynamics , Imaging, Three-Dimensional
12.
Front Physiol ; 14: 1113034, 2023.
Article in English | MEDLINE | ID: mdl-37275225

ABSTRACT

Introduction: Computational fluid dynamics (CFD) assess biological systems based on specific boundary conditions. We propose modeling more advanced hemodynamic metrics, such as core line length (CL) and critical points which characterize complexity of flow in the context of cerebral vasculature, and specifically cerebral veins during the physiologically evolving early neonatal state of vein of Galen malformations (VOGM). CFD has not been applied to the study of arteriovenous shunting in Vein of Galen Malformations but could help illustrate the pathophysiology of this malformation. Methods: Three neonatal patients with VOGM at Boston Children's Hospital met inclusion criteria for this study. Structural MRI data was segmented to generate a mesh of the VOGM and venous outflow. Boundary condition flow velocity was derived from PC-MR sequences with arterial and venous dual velocity encoding. The mesh and boundary conditions were applied to model the cerebral venous flow. We computed flow variables including mean wall shear stress (WSSmean), mean OSI, CL, and the mean number of critical points (nCrPointsmean) for each patient specific model. A critical point is defined as the location where the shear stress vector field is zero (stationary point) and can be used to describe complexity of flow. Results: The division of flow into the left and right venous outflow was comparable between PC-MR and CFD modeling. A high complexity recirculating flow pattern observed on PC-MR was also identified on CFD modeling. Regions of similar WSSmean and OSImean (<1.3 fold) in the left and right venous outflow channels of a single patient have several-fold magnitude difference in higher order hemodynamic metrics (> 3.3 fold CL, > 1.7 fold nCrPointsmean). Specifically, the side which developed JBS in each model had greater nCrPointsmean compared to the jugular bulb with no stenosis (VOGM1: 4.49 vs. 2.53, VOGM2: 1.94 vs. 0, VOGM3: 1 vs. 0). Biologically, these regions had subsequently divergent development, with increased complexity of flow associating with venous stenosis. Discussion: Advanced metrics of flow complexity identified in computational models may reflect observed flow phenomena not fully characterized by primary or secondary hemodynamic parameters. These advanced metrics may indicate physiological states that impact development of jugular bulb stenosis in VOGM.

13.
Int J Comput Assist Radiol Surg ; 18(12): 2243-2252, 2023 Dec.
Article in English | MEDLINE | ID: mdl-36877287

ABSTRACT

PURPOSE: Intracranial aneurysms (IAs) are pathological changes of the intracranial vessel wall, although clinical image data can only show the vessel lumen. Histology can provide wall information but is typically restricted to ex vivo 2D slices where the shape of the tissue is altered. METHODS: We developed a visual exploration pipeline for a comprehensive view of an IA. We extract multimodal information (like stain classification and segmentation of histologic images) and combine them via 2D to 3D mapping and virtual inflation of deformed tissue. Histological data, including four stains, micro-CT data and segmented calcifications as well as hemodynamic information like wall shear stress (WSS), are combined with the 3D model of the resected aneurysm. RESULTS: Calcifications were mostly present in the tissue part with increased WSS. In the 3D model, an area of increased wall thickness was identified and correlated to histology, where the Oil red O (ORO) stained images showed a lipid accumulation and the alpha-smooth muscle actin (aSMA) stained images showed a slight loss of muscle cells. CONCLUSION: Our visual exploration pipeline combines multimodal information about the aneurysm wall to improve the understanding of wall changes and IA development. The user can identify regions and correlate how hemodynamic forces, e.g. WSS, are reflected by histological structures of the vessel wall, wall thickness and calcifications.


Subject(s)
Intracranial Aneurysm , Humans , Intracranial Aneurysm/diagnostic imaging , Intracranial Aneurysm/pathology , Hemodynamics/physiology , Imaging, Three-Dimensional/methods , Stress, Mechanical
14.
Cardiovasc Eng Technol ; 14(1): 92-103, 2023 02.
Article in English | MEDLINE | ID: mdl-35819581

ABSTRACT

PURPOSE: Blebs are known risk factors for intracranial aneurysm (IA) rupture. We analyzed differences between IAs that ruptured with blebs and those that ruptured without developing blebs to identify distinguishing characteristics among them and suggest possible mechanistic implications. METHODS: Using image-based models, 25 hemodynamic and geometric parameters were compared between ruptured IAs with and without blebs (n = 673), stratified by location. Hemodynamic and geometric differences between bifurcation and sidewall aneurysms and for aneurysms at five locations were also analyzed. RESULTS: Ruptured aneurysms harboring blebs were exposed to higher flow conditions than aneurysms that ruptured without developing blebs, and this was consistent across locations. Bifurcation aneurysms were exposed to higher flow conditions than sidewall aneurysms. They had larger maximum wall shear stress (WSS), more concentrated WSS distribution, and larger numbers of critical points than sidewall aneurysms. Additionally, bifurcation aneurysms were larger, more elongated, and had more distorted shapes than sidewall aneurysms. Aneurysm morphology was associated with aneurysm location (p < 0.01). Flow conditions were different between aneurysm locations. CONCLUSION: Aneurysms at different locations are likely to develop into varying morphologies and thus be exposed to diverse flow conditions that may predispose them to follow distinct pathways towards rupture with or without bleb development. This could explain the diverse rupture rates and bleb presence in aneurysms at different locations.


Subject(s)
Aneurysm, Ruptured , Intracranial Aneurysm , Humans , Hemodynamics , Intracranial Aneurysm/diagnostic imaging , Risk Factors , Stress, Mechanical
15.
Front Physiol ; 13: 881627, 2022.
Article in English | MEDLINE | ID: mdl-35923225

ABSTRACT

Background and Purpose: Delayed intraparenchymal hemorrhages (DIPHs) are one of the most serious complications of cerebral aneurysm treatment with flow diverters (FD), yet their causes are largely unknown. This study analyzes distal hemodynamic alterations induced by the treatment of intracranial aneurysms with FDs. Methods: A realistic model of the brain arterial network was constructed from MRA images and extended with a constrained constructive optimization technique down to vessel diameters of approximately 50 µ m . Different variants of the circle of Willis were created by alternatively occluding communicating arteries. Collateral vessels connecting different arterial trees were then added to the model, and a distributed lumped parameter approach was used to model the pulsatile blood flow in the arterial network. The treatment of an ICA aneurysm was modeled by changing the local resistance, flow inertia, and compliance of the aneurysmal segment. Results: The maximum relative change in distal pressure induced by the aneurysm treatment was below 1%. However, for certain combinations of the circle of Willis and distal collateralization, important flow reversals (with a wall shear stress larger than approximately 1.0   d y n e / c m 2 ) were observed in collateral vessels, both ipsilaterally and contralaterally to the treated aneurysm. Conclusion: This study suggests the hypothesis that flow diverters treatment of intracranial aneurysms could cause important flow reversal in distal collaterals. Flow reversal has previously been shown to be pro-inflammatory and pro-atherogenic and could therefore have a detrimental effect on these collateral vessels, and thus could be a suitable explanation of DIPHs, while the small distal pressure increase is not.

16.
J Neurointerv Surg ; 14(10): 1002-1007, 2022 Oct.
Article in English | MEDLINE | ID: mdl-34686573

ABSTRACT

BACKGROUND: Bleb presence in intracranial aneurysms (IAs) is a known indication of instability and vulnerability. OBJECTIVE: To develop and evaluate predictive models of bleb development in IAs based on hemodynamics, geometry, anatomical location, and patient population. METHODS: Cross-sectional data (one time point) of 2395 IAs were used for training bleb formation models using machine learning (random forest, support vector machine, logistic regression, k-nearest neighbor, and bagging). Aneurysm hemodynamics and geometry were characterized using image-based computational fluid dynamics. A separate dataset with 266 aneurysms was used for model evaluation. Model performance was quantified by the area under the receiving operating characteristic curve (AUC), true positive rate (TPR), false positive rate (FPR), precision, and balanced accuracy. RESULTS: The final model retained 18 variables, including hemodynamic, geometrical, location, multiplicity, and morphology parameters, and patient population. Generally, strong and concentrated inflow jets, high speed, complex and unstable flow patterns, and concentrated, oscillatory, and heterogeneous wall shear stress patterns together with larger, more elongated, and more distorted shapes were associated with bleb formation. The best performance on the validation set was achieved by the random forest model (AUC=0.82, TPR=91%, FPR=36%, misclassification error=27%). CONCLUSIONS: Based on the premise that aneurysm characteristics prior to bleb formation resemble those derived from vascular reconstructions with their blebs virtually removed, machine learning models can identify aneurysms prone to bleb development with good accuracy. Pending further validation with longitudinal data, these models may prove valuable for assessing the propensity of IAs to progress to vulnerable states and potentially rupturing.


Subject(s)
Aneurysm, Ruptured , Intracranial Aneurysm , Humans , Aneurysm, Ruptured/epidemiology , Cross-Sectional Studies , Hemodynamics , Hydrodynamics , Intracranial Aneurysm/complications , Intracranial Aneurysm/diagnostic imaging , Intracranial Aneurysm/surgery , Machine Learning
17.
Bioengineering (Basel) ; 8(11)2021 Oct 21.
Article in English | MEDLINE | ID: mdl-34821715

ABSTRACT

Intracranial aneurysms (IAs) are localized enlargements of cerebral blood vessels that cause substantial rates of mortality and morbidity in humans. The rupture possibility of these aneurysms is a critical medical challenge for physicians during treatment planning. This treatment planning while assessing the rupture potential of aneurysms becomes more complicated when they are constrained by an adjacent structure such as optic nerve tissues or bones, which is not widely studied yet. In this work, we considered and studied a constitutive model to investigate the bio-mechanical response of image-based patient-specific IA data using cardiovascular structural mechanics equations. We performed biomechanical modeling and simulations of four different patient-specific aneurysms' data (three middle cerebral arteries and one internal carotid artery) to assess the rupture potential of those aneurysms under a plane contact constraint. Our results suggest that aneurysms with plane contact constraints produce less or almost similar maximum wall effective stress compared to aneurysms with no contact constraints. In our research findings, we observed that a plane contact constraint on top of an internal carotid artery might work as a protective wall due to the 16.6% reduction in maximum wall effective stress than that for the case where there is no contact on top of the aneurysm.

18.
J Neurointerv Surg ; 13(3): 231-236, 2021 Mar.
Article in English | MEDLINE | ID: mdl-32680874

ABSTRACT

BACKGROUND: Although it is generally believed that blebs represent weaker spots in the walls of intracranial aneurysms (IAs), it is largely unknown which aneurysm characteristics favor their development. OBJECTIVE: To investigate possible associations between aneurysm hemodynamic and geometric characteristics and the development of blebs in intracranial aneurysms. METHODS: A total of 270 IAs in 199 patients selected for surgical clipping were studied. Blebs were visually identified and interactively marked on patient-specific vascular models constructed from presurgical images. Blebs were then deleted from the vascular reconstruction to approximate the aneurysm before bleb formation. Computational fluid dynamics studies were performed in these models and in cases without blebs. Hemodynamic and geometric characteristics of aneurysms with and without blebs were compared. RESULTS: A total of 173 aneurysms had no blebs, while 97 aneurysms had a total of 122 blebs. Aneurysms favoring bleb formation had stronger (p<0.0001) and more concentrated inflow jets (p<0.0001), higher flow velocity (p=0.0061), more complex (p<0.0001) and unstable (p=0.0157) flow patterns, larger maximum wall shear stress (WSS; p<0.0001), more concentrated (p=0.0005) and oscillatory (p=0.0004) WSS distribution, and a more heterogeneous WSS field (p<0.0001), than aneurysms without blebs. They were also larger (p<0.0001), more elongated (p<0.0001), had wider necks (p=0.0002), and more distorted and irregular shapes (p<0.0001). CONCLUSIONS: Strong and concentrated inflow jets, high-speed, complex, and unstable flow patterns, and concentrated, oscillatory, and heterogeneous WSS patterns favor the formation of blebs in IAs. Blebs are more likely to form in large, elongated, and irregularly shaped aneurysms. These adverse characteristics could be considered signs of aneurysm instability when evaluating aneurysms for conservative observation or treatment.


Subject(s)
Aneurysm, Ruptured , Hemodynamics , Intracranial Aneurysm , Adult , Female , Humans , Male , Middle Aged , Aneurysm, Ruptured/diagnostic imaging , Aneurysm, Ruptured/physiopathology , Aneurysm, Ruptured/surgery , Hemodynamics/physiology , Hydrodynamics , Imaging, Three-Dimensional/methods , Intracranial Aneurysm/diagnostic imaging , Intracranial Aneurysm/physiopathology , Intracranial Aneurysm/surgery , Risk Factors , Stress, Mechanical
19.
J Neurointerv Surg ; 13(3): 226-230, 2021 Mar.
Article in English | MEDLINE | ID: mdl-32680877

ABSTRACT

BACKGROUND: Blebs are rupture risk factors in intracranial aneurysms (IAs), but their prevalence, distribution, and associations with clinical factors as well as their causes and effects on aneurysm vulnerability remain unclear. METHODS: A total of 122 blebs in 270 IAs selected for surgery were studied using patient-specific vascular reconstructions from 3D angiographic images. Bleb geometry, location on the aneurysm, and frequency of occurrence in aneurysms at different locations were analyzed. Associations between gender, age, smoking, hypertension, hormone therapy, dental infection, and presence of blebs were investigated. RESULTS: Of all aneurysms with blebs, 77% had a single bleb and 23% had multiple blebs. Only 6% of blebs were at the neck, while 46% were in the body and 48% in the dome. Aneurysms with blebs were larger (p<0.0001), more elongated (p=0.0002), and with wider necks than aneurysms without blebs. Bleb presence was associated with dental infection (p=0.0426) and negatively associated with hormone therapy (p=0.0426) in women. Anterior and posterior communicating arteries had larger percentages of aneurysms with blebs than internal carotid arteries. Patients with a history of hypertension tended to have a larger percentage of aneurysms with blebs. However, these trends did not reach significance in this sample. CONCLUSIONS: Blebs are common in IAs, and most aneurysms harboring blebs have a single bleb. Blebs in the aneurysm neck are rare, but they are equally common in the body and dome. The presence of blebs in IAs was associated with dental infection, and negatively associated with hormone replacement therapy.


Subject(s)
Aneurysm, Ruptured , Intracranial Aneurysm , Adult , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Aneurysm, Ruptured/diagnostic imaging , Aneurysm, Ruptured/epidemiology , Aneurysm, Ruptured/surgery , Carotid Artery, Internal/physiopathology , Cerebral Angiography/methods , Hypertension/diagnostic imaging , Hypertension/epidemiology , Hypertension/surgery , Intracranial Aneurysm/diagnostic imaging , Intracranial Aneurysm/epidemiology , Intracranial Aneurysm/surgery , Prevalence , Risk Factors , Smoking/adverse effects , Smoking/epidemiology
20.
J Vasc Surg ; 73(5): 1611-1621.e2, 2021 05.
Article in English | MEDLINE | ID: mdl-33166609

ABSTRACT

OBJECTIVE: We have shown that almost 50% of patients with asymptomatic carotid stenosis (ACS) will demonstrate cognitive impairment. Recent evidence has suggested that cerebral hypoperfusion is an important cause of cognitive impairment. Carotid stenosis can restrict blood flow to the brain, with consequent cerebral hypoperfusion. In contrast, cross-hemispheric collateral compensation through the Circle of Willis, and cerebrovascular vasodilation can also mitigate the effects of flow restriction. It is, therefore, critical to develop a clinically relevant measure of net brain perfusion in patients with ACS that could help in risk stratification and in determining the appropriate treatment. To determine whether ACS results in cerebral hypoperfusion, we developed a novel approach to quantify interhemispheric cerebral perfusion differences, measured as the time to peak (TTP) and mean transit time (MTT) delays using perfusion-weighted magnetic resonance imaging (PWI) of the whole brain. To evaluate the utility of using clinical duplex ultrasonography (DUS) to infer brain perfusion, we also assessed the relationship between the PWI findings and ultrasound-based peak systolic velocity (PSV). METHODS: Structural and PWI of the brain and magnetic resonance angiography of the carotid arteries were performed in 20 patients with ≥70% ACS. DUS provided the PSV, and magnetic resonance angiography provided plaque geometric measures at the stenosis. Volumetric perfusion maps of the entire brain from PWI were analyzed to obtain the mean interhemispheric differences for the TTP and MTT delays. In addition, the proportion of brain volume that demonstrated a delay in TTP and MTT was also measured. These proportions were measured for increasing severity of perfusion delays (0.5, 1.0, and 2.0 seconds). Finally, perfusion asymmetries on PWI were correlated with the PSV and stenosis features on DUS using Pearson's correlation coefficients. RESULTS: Of the 20 patients, 18 had unilateral stenosis (8 right and 10 left) and 2 had bilateral stenoses. The interhemispheric (left-right) TTP delays measured for the whole brain volume identified impaired perfusion in the hemisphere ipsilateral to the stenosis in 16 of the 18 patients. More than 45% of the patients had had ischemia in at least one half of their brain volume, with a TTP delay >0.5 second. The TTP and MTT delays showed strong correlations with PSV. In contrast, the correlations with the percentage of stenosis were weaker. The correlations for the PSV were strongest with the perfusion deficits (TTP and MTT delays) measured for the whole brain using our proposed algorithm (r = 0.80 and r = 0.74, respectively) rather than when measured on a single magnetic resonance angiography slice as performed in current clinical protocols (r = 0.31 and r = 0.58, respectively). CONCLUSIONS: Interhemispheric TTP and MTT delay measured for the whole brain using PWI has provided a new tool for assessing cerebral perfusion deficits in patients with ACS. Carotid stenosis was associated with a detectable reduction in ipsilateral brain perfusion compared with the opposite hemisphere in >80% of patients. The PSV measured at the carotid stenosis using ultrasonography correlated with TTP and MTT delays and might serve as a clinically useful surrogate to brain hypoperfusion in these patients.


Subject(s)
Carotid Stenosis/complications , Cerebrovascular Circulation , Cerebrovascular Disorders/diagnostic imaging , Diffusion Magnetic Resonance Imaging , Perfusion Imaging , Ultrasonography, Doppler, Duplex , Ultrasonography, Doppler, Transcranial , Aged , Asymptomatic Diseases , Blood Flow Velocity , Carotid Stenosis/diagnostic imaging , Carotid Stenosis/physiopathology , Cerebrovascular Disorders/etiology , Cerebrovascular Disorders/physiopathology , Female , Humans , Magnetic Resonance Angiography , Male , Middle Aged , Predictive Value of Tests , Reproducibility of Results , Risk Factors
SELECTION OF CITATIONS