Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 27
Filter
1.
Gait Posture ; 112: 134-139, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38772125

ABSTRACT

BACKGROUND: Enhancing traditional three-dimensional gait analysis with a portable ultrasound device at the lower-limb muscle-tendon level enables direct measurement of muscle and tendon lengths during walking. However, it is important to consider that the size of the ultrasound probe and its attachment on the lower limb may potentially influence gait pattern. RESEARCH QUESTION: What is the effect of wearing an ultrasound probe at the lower limb in adolescents with cerebral palsy and typically developing peers? METHODS: Eleven individuals with cerebral palsy and nine age-matched typically developing peers walking barefoot at their self-selected speed were analyzed. Data collection occurred under three conditions: the reference condition (GAIT), and two conditions involving placement of the ultrasound probe over the distal medial gastrocnemius-Achilles tendon junction (MTJ) and over the medial gastrocnemius mid-belly to capture fascicles (FAS). Data processing included calculating differences between conditions using root mean square error (RMSE) for joint kinematics and comparing them to the overall mean difference. Additionally, Spearman correlations were calculated to examine the relationship between kinematic RMSEs and walking speed. RESULTS: No significant differences in stance phase duration or walking speed were observed among the three conditions. Average RMSEs were below 5° for all parameters and condition comparisons in both groups. In both the TD and CP groups, RMSE values during the swing phase were higher than those during the stance phase for all joints. No significant correlations were found between height or body mass and swing phase RMSEs. In the CP group, there was a significant correlation between joint kinematics RMSEs and differences in walking speed at the hip, knee and ankle joints when comparing the MTJ condition with the GAIT condition. SIGNIFICANCE: This study confirms joint kinematics alterations are smaller than 5° due to wearing to the leg an ultrasound probe during walking.


Subject(s)
Cerebral Palsy , Ultrasonography , Walking , Humans , Cerebral Palsy/physiopathology , Cerebral Palsy/diagnostic imaging , Adolescent , Male , Biomechanical Phenomena , Female , Walking/physiology , Muscle, Skeletal/diagnostic imaging , Muscle, Skeletal/physiopathology , Lower Extremity/physiopathology , Lower Extremity/diagnostic imaging , Gait Analysis , Case-Control Studies , Walking Speed/physiology , Ankle Joint/physiopathology , Ankle Joint/diagnostic imaging , Child , Knee Joint/physiopathology , Knee Joint/diagnostic imaging , Knee Joint/physiology , Gait/physiology , Hip Joint/physiopathology , Hip Joint/diagnostic imaging , Achilles Tendon/diagnostic imaging , Achilles Tendon/physiopathology
2.
Clin Biomech (Bristol, Avon) ; 111: 106158, 2024 01.
Article in English | MEDLINE | ID: mdl-38061205

ABSTRACT

BACKGROUND: The interplay between the medial gastrocnemius muscle and the Achilles tendon is crucial for efficient walking. In cerebral palsy, muscle and tendon remodelling alters the role of contractile and elastic components. The aim was to investigate the length changes of medial gastrocnemius belly and fascicles, and Achilles tendon to understand their interplay to gait propulsion in individuals with cerebral palsy. METHODS: Twelve young individuals with cerebral palsy and 12 typically developed peers were assessed during multiple gait cycles using 3D gait analysis combined with a portable ultrasound device. By mapping ultrasound image locations into the shank reference frame, the medial gastrocnemius belly, fascicle, and Achilles tendon lengths were estimated throughout the gait cycle. Participants with cerebral palsy were classified into equinus and non-equinus groups based on their sagittal ankle kinematics. FINDINGS: In typically developed participants, the Achilles tendon undertook most of the muscle-tendon unit lengthening during stance, whereas in individuals with cerebral palsy, this lengthening was shared between the medial gastrocnemius belly and Achilles tendon, which was more evident in the equinus group. The lengthening behaviour of the medial gastrocnemius fascicles resembled that of the Achilles tendon in cerebral palsy. INTERPRETATION: The findings revealed similar length changes of the medial gastrocnemius fascicles and Achilles tendon, highlighting the enhanced role of the muscle in absorbing energy during stance in cerebral palsy. These results, together with the current knowledge of increased intramuscular stiffness, suggest the exploitation of intramuscular passive forces for such energy absorption.


Subject(s)
Achilles Tendon , Cerebral Palsy , Humans , Achilles Tendon/diagnostic imaging , Achilles Tendon/physiology , Biomechanical Phenomena , Cerebral Palsy/complications , Muscle, Skeletal/diagnostic imaging , Muscle, Skeletal/physiology , Gait/physiology , Ultrasonography/methods
3.
Med Sci Sports Exerc ; 56(1): 1-12, 2024 Jan 01.
Article in English | MEDLINE | ID: mdl-37565430

ABSTRACT

PURPOSE: Numerous exercise interventions to enhance motor function in cerebral palsy (CP) have been proposed, with varying degrees of effectiveness. Because motor function requires a combination of muscle strength, joint flexibility, and motor coordination, we designed a supervised multicomponent exercise intervention (EXErcise for Cerebral Palsy, or EXECP) for individuals with CP. Our aim was to evaluate the effects of the EXECP intervention and its retention after it ceased. METHODS: The EXECP intervention combined strength training for the lower limbs and trunk muscles, passive stretching for the lower limb muscles, and inclined treadmill gait training. Eighteen participants with CP (mean age, 14 yr; 13 were male) were tested twice before the 3-month intervention and twice after the intervention, each test separated by 3 months. Seventeen typically developing age- and sex-matched controls were tested twice. Motor function was assessed with the 6-min walking test (6MWT) and the gross motor function measure dimensions D and E. Passive joint flexibility was measured with goniometry. Isometric and concentric muscle strength were assessed at the knee, ankle, and trunk joints. RESULTS: The EXECP intervention successfully increased 6MWT ( P < 0.001), gross motor function measure ( P = 0.004), and muscle strength for knee and trunk muscles ( P < 0.05), although no changes were observed for ankle joint muscles. Hip and knee joint flexibility also increased ( P < 0.05). After the retention period, all tested variables except the 6MWT and knee joint flexibility regressed and were not different from the pretests. CONCLUSIONS: The improvements in strength, flexibility, and possibly motor coordination brought by the EXECP intervention were transferred to significant functional gains. The regression toward baseline after the intervention highlights that training must be a lifelong decision for individuals with CP.


Subject(s)
Cerebral Palsy , Gait , Humans , Male , Adolescent , Female , Gait/physiology , Lower Extremity , Muscle, Skeletal , Muscle Strength/physiology , Range of Motion, Articular/physiology
4.
J Biomech ; 152: 111567, 2023 05.
Article in English | MEDLINE | ID: mdl-37023558

ABSTRACT

Muscle architecture parameters, such as the fascicle length, pennation angle, and volume, are important muscle morphology characteristics. Accurate in vivo quantification of these parameters allows to detect changes due to pathologies, interventions, and rehabilitation trainings, which ultimately impact on muscles' force-producing capacity. In this study, we compared three-dimensional (3D) muscle architecture parameters of the tibialis anterior and gastrocnemius medialis, which were quantified by 3D freehand ultrasound (3DfUS) and a magnetic resonance imaging (MRI) technique, diffusion tensor imaging (DTI), respectively. Sixteen able-bodied subjects were recruited where seven of them received both 3DfUS and MRI measurement, while the rest underwent 3DfUS measurements twice. Good to excellent intra-rater reliability and inter-session repeatability were found in 3DfUS measurements (intra-class correlation coefficient > 0.81). Overall, the two imaging modalities yielded consistent measurements of the fascicle length, pennation angle, and volume with mean differences smaller than 2.9 mm, 1.8°, and 5.7 cm3, respectively. The only significant difference was found in the pennation angle of the tibialis anterior, although the discrepancy was small. Our study demonstrated, for the first time, that 3DfUS measurement had high reliability and repeatability for measurement of muscle architecture in vivo and could be regarded as an alternative to MRI for 3D evaluation of muscle morphology.


Subject(s)
Diffusion Tensor Imaging , Muscle, Skeletal , Humans , Reproducibility of Results , Muscle, Skeletal/physiology , Magnetic Resonance Imaging/methods , Ultrasonography
5.
Front Bioeng Biotechnol ; 10: 897852, 2022.
Article in English | MEDLINE | ID: mdl-36507281

ABSTRACT

Hyper-resistance is an increased resistance to passive muscle stretch, a common feature in neurological disorders. Stretch hyperreflexia, an exaggerated stretch reflex response, is the neural velocity-dependent component of hyper-resistance, and has been quantitatively measured using the stretch reflex threshold (i.e., joint angle at the stretch reflex electromyographic onset). In this study, we introduce a correction in how the stretch reflex threshold is calculated, by accounting for the stretch reflex latency (i.e., time between the stretch reflex onset at the muscle spindles and its appearance in the electromyographic signal). Furthermore, we evaluated how this correction affects the stretch reflex threshold in children and young adults with spastic cerebral palsy. A motor-driven ankle dynamometer induced passive ankle dorsiflexions at four incremental velocities in 13 children with cerebral palsy (mean age: 13.5 years, eight males). The stretch reflex threshold for soleus and medial gastrocnemius muscles was calculated as 1) the joint angle corresponding to the stretch reflex electromyographic onset (i.e., original method); and as 2) the joint angle corresponding to the electromyographic onset minus the individual Hoffmann-reflex latency (i.e., latency corrected method). The group linear regression slopes between stretch velocity and stretch reflex threshold differed in both muscles between methods (p < 0.05). While the original stretch reflex threshold was velocity dependent in both muscles (p < 0.05), the latency correction rendered it velocity independent. Thus, the effects of latency correction on the stretch reflex threshold are substantial, especially at higher stretch velocities, and should be considered in future studies.

7.
Gait Posture ; 90: 464-467, 2021 10.
Article in English | MEDLINE | ID: mdl-34619612

ABSTRACT

BACKGROUND: Ultrasound imaging combined with 3D motion analysis allows for in-vivo assessment of muscle-tendon unit lengths during gait. The clinical relevance of analysing the medial gastrocnemius (MG) and Achilles muscle-tendon junction (MTJ), MG mid-muscle belly fascicles (FAS) and muscle thickness was shown. However, their reliability error estimations over the gait cycle is unknown. RESEARCH QUESTION: What are the intra- and inter-session errors associated with extracting MG belly, thickness, FAS and tendon lengths using ultrasound during gait in healthy participants? METHODS: 3D gait analysis was carried out in ten healthy adults as they walked on an instrumented treadmill at a comfortable walking speed. An ultrasound probe was secured on the leg and tracked by 3D motion analysis. Images were collected during two walking trials with the probe on the MG muscle-belly to estimate FAS lengths and muscle thickness, and during two trials with the probe on the MTJ to estimate muscle-belly and tendon lengths. A second session was performed after 5 ± 4 days where a different operator placed the ultrasound probe. The standard deviation (SD) of absolute and relative lengths changes during the gait cycle over different trials were calculated per participant. SD values averaged over participants represented intra- and inter-session errors. RESULTS: For all assessed variables, the intra-session errors were <2.2 mm, except for the FAS lengths (3.1 mm). The inter-session errors were larger than the intra-session, with the highest values found for the absolute muscle-tendon unit lengths (5.6 mm). Relative length errors were smaller than absolute length errors. SIGNIFICANCE: Intra-session errors, which may reflect natural variability and data processing errors, seem more critical when extracting absolute FAS than muscle-tendon lengths. Standardized probe positioning on the MTJ between sessions may improve the inter-session reliability. Expressing the lengths relative to their lengths as the beginning of the gait cycle reduces the inter-session errors.


Subject(s)
Achilles Tendon , Gait , Achilles Tendon/diagnostic imaging , Adult , Humans , Muscle, Skeletal/diagnostic imaging , Reproducibility of Results , Ultrasonography , Walking
8.
Ultrasound Med Biol ; 47(9): 2702-2712, 2021 09.
Article in English | MEDLINE | ID: mdl-34112554

ABSTRACT

This investigation assessed the processer reliability of estimating muscle volume and echo-intensity of the rectus femoris, tibialis anterior and semitendinosus. The muscles of 10 typically developing children (8.15 [1.40] y) and 15 children with spastic cerebral palsy (7.67 [3.80] y; Gross Motor Function Classification System I = 5, II = 5, III = 5) were scanned with 3-D freehand ultrasonography. For the intra-processer analysis, the intra-class correlations coefficients (ICCs) for muscle volume ranged from 0.943-0.997, with relative standard errors of measurement (SEM%) ranging from 1.24%-8.97%. For the inter-processer analysis, these values were 0.853 to 0.988 and 3.47% to 14.02%, respectively. Echo-intensity had ICCs >0.947 and relative SEMs <4% for both analyses. Muscle volume and echo-intensity can be reliably extracted for the rectus femoris, semitendinosus and tibialis anterior in typically developing children and children with cerebral palsy. The need for a single processer to analyze all data is dependent on the size of the expected changes or differences.


Subject(s)
Cerebral Palsy , Muscle Spasticity , Cerebral Palsy/diagnostic imaging , Child , Humans , Lower Extremity/diagnostic imaging , Muscle Spasticity/diagnostic imaging , Muscle, Skeletal/diagnostic imaging , Reproducibility of Results , Ultrasonography
9.
Front Neurol ; 11: 210, 2020.
Article in English | MEDLINE | ID: mdl-32373040

ABSTRACT

Botulinum NeuroToxin-A (BoNT-A) injections to the medial gastrocnemius (MG) and lower-leg casts are commonly combined to treat ankle equinus in children with spastic cerebral palsy (CP). However, the decomposed treatment effects on muscle or tendon structure, stretch reflexes, and joint are unknown. In this study, BoNT-A injections to the MG and casting of the lower legs were applied separately to gain insight into the working mechanisms of the isolated treatments on joint, muscle, and tendon levels. Thirty-one children with spastic CP (GMFCS I-III, age 7.4 ± 2.6 years) received either two weeks of lower-leg casts or MG BoNT-A injections. During full range of motion slow and fast passive ankle rotations, joint resistance and MG stretch reflexes were measured. MG muscle and tendon lengths were assessed at resting and at maximum dorsiflexion ankle angles using 3D-freehand ultrasound. Treatment effects were compared using non-parametric statistics. Associations between the effects on joint and muscle or tendon levels were performed using Spearman correlation coefficients (p < 0.05). Increased joint resistance, measured during slow ankle rotations, was not significantly reduced after either treatment. Additional joint resistance assessed during fast rotations only reduced in the BoNT-A group (-37.6%, p = 0.013, effect size = 0.47), accompanied by a reduction in MG stretch reflexes (-70.7%, p = 0.003, effect size = 0.56). BoNT-A increased the muscle length measured at the resting ankle angle (6.9%, p = 0.013, effect size = 0.53). Joint angles shifted toward greater dorsiflexion after casting (32.4%, p = 0.004, effect size = 0.56), accompanied by increases in tendon length (5.7%, p = 0.039, effect size = 0.57; r = 0.40). No associations between the changes in muscle or tendon lengths and the changes in the stretch reflexes were found. We conclude that intramuscular BoNT-A injections reduced stretch reflexes in the MG accompanied by an increase in resting muscle belly length, whereas casting resulted in increased dorsiflexion without any changes to the muscle length. This supports the need for further investigation on the effect of the combined treatments and the development of treatments that more effectively lengthen the muscle.

10.
Exp Physiol ; 105(1): 120-131, 2020 01.
Article in English | MEDLINE | ID: mdl-31677311

ABSTRACT

NEW FINDINGS: What is the central question of this study? Is the proposed semi-automatic algorithm suitable for tracking the medial gastrocnemius muscle-tendon junction in ultrasound images collected during passive and active conditions? What is the main finding and its importance? The validation of a method allowing efficient tracking of the muscle-tendon junction in both passive and active conditions, in healthy as well as in pathological conditions. This method was tested in common acquisition conditions and the developed software made freely available. ABSTRACT: Clinically relevant information can be extracted from ultrasound (US) images by tracking the displacement of the junction between muscle and tendon. This paper validated automatic methods for tracking the location of muscle-tendon junction (MTJ) between the medial gastrocnemius and the Achilles tendon during passive slow and fast stretches, and active ankle rotations while walking on a treadmill. First, an automatic algorithm based on an optical flow approach was applied on collected US images. Second, results of the automatic algorithm were evaluated and corrected using a quality measure that indicated which critical images need to be manually corrected. US images from 12 typically developed (TD) children, 12 children with spastic cerebral palsy (SCP) and eight healthy adults were analysed. Automatic and semi-automatic tracking methods were compared to manual tracking using root mean square errors (RMSE). For the automatic tracking, RMSE was less than 3.1 mm for the slow stretch and 5.2 mm for the fast stretch, the worst case being for SCP. The tracking results in the fast stretch condition were improved (especially in SCP) by using the semi-automatic approach, with an RMSE reduction of about 30%. During walking, the semi-automatic method also reduced errors, with a final RMSE of 3.6 mm. In all cases, data processing was considerably shorter using the semi-automatic method (2 min) compared to manual tracking (20 min). A quick manual correction considerably improves tracking of the MTJ during gait and allows to achieve results suitable for further analyses. The proposed algorithm is freely available.


Subject(s)
Achilles Tendon/diagnostic imaging , Ankle/diagnostic imaging , Muscle, Skeletal/diagnostic imaging , Adult , Algorithms , Cerebral Palsy , Child , Electronic Data Processing , Humans , Rotation , Software , Ultrasonography , Walking , Young Adult
11.
Gait Posture ; 68: 531-537, 2019 02.
Article in English | MEDLINE | ID: mdl-30623848

ABSTRACT

BACKGROUND: Individuals with spastic cerebral palsy (CP) have neuromotor symptoms contributing towards their gait patterns. However, the role of altered muscle morphology alongside these symptoms is yet to be fully investigated. RESEARCH QUESTION: To what extent can medial gastrocnemius and tibialis anterior volume and echo-intensity, plantar/dorsiflexion strength and selective motor control, plantarflexion spasticity and passive ankle dorsiflexion explain abnormal ankle gait. METHOD: In thirty children and adolescents with spastic CP (8.6 ± 3.4 y/mo) and ten typically developing peers (9.9 ± 2.4 y/mo), normalised muscle volume and echo-intensity were estimated. Both cohorts also underwent three-dimensional gait analysis, whilst for participants with spastic CP, plantar/dorsi-flexion strength and selective motor control, plantarflexion spasticity and maximum ankle dorsiflexion were also measured. The combined contribution of these parameters towards five clinically meaningful features of gait were evaluated, using backwards multiple regression analyses. RESULTS: With respect to the typically developing cohort, the participants with spastic CP had deficits in normalised medial gastrocnemius and tibialis anterior volume of 40% and 33%, and increased echo-intensity values of 19% and 16%, respectively. The backwards multiple regression analyses revealed that the combination of reduced ankle dorsiflexion, muscle volume, plantarflexion strength and dorsiflexion selective motor control could account for 12-62% of the variance in the chosen features of gait. SIGNIFICANCE: The combination of altered muscle morphology and neuromotor symptoms partly explained abnormal gait at the ankle in children with spastic CP. Both should be considered as important measures for informed treatment decision-making, but further work is required to better unravel the complex pathophysiology.


Subject(s)
Ankle Joint/physiopathology , Cerebral Palsy/physiopathology , Gait/physiology , Imaging, Three-Dimensional/methods , Muscle Spasticity/physiopathology , Muscle, Skeletal/diagnostic imaging , Ultrasonography/methods , Adolescent , Cerebral Palsy/complications , Cerebral Palsy/diagnosis , Child , Child, Preschool , Female , Follow-Up Studies , Humans , Male , Muscle Spasticity/diagnosis , Muscle Spasticity/etiology , Muscle, Skeletal/physiopathology
12.
Ultrasonics ; 94: 124-130, 2019 Apr.
Article in English | MEDLINE | ID: mdl-30558809

ABSTRACT

The ultrasound (US) probe spatial calibration is a key prerequisite for enabling the use of the 3D freehand US technique. Several methods have been proposed for achieving an accurate and precise calibration, although these methods still require specialised equipment. This equipment is often not available in research or clinical facilities. Therefore, the present investigation aimed to propose an efficient US probe calibration method that is accessible in terms of cost, easy to apply and capable of achieving results suitable for clinical applications. The data acquisition was carried out by performing two perpendicular US sweeps over water filled balloon phantoms. The data analysis was carried out by computing the similarity measures between 2D images from the first sweep and the corresponding images of the 3D reconstruction of the second sweep. These measures were maximized by using the Nelder-Mead algorithm, to find the optimal solution for the calibration parameters. The calibration results were evaluated in terms of accuracy and precision by comparing known phantom geometries with those extracted from the US images. The accuracy and the precision after applying the calibration method were improved. By using the parameters obtained from the plane phantom method as initialization of the calibration parameters, the accuracy and the precision in the best scenario was 0.4 mm and 1.5 mm, respectively. These results were in line with the methods requiring specialised equipment. However, the applied method was unable to consistently produce this level of accuracy and precision. The calibration parameters were also tested in a musculoskeletal application, revealing sufficient matching of the relevant anatomical features when multiple US sweeps are combined in a 3D reconstruction. To improve the current results and increase the reproducibility of this research, the developed software is made available.

13.
Dev Med Child Neurol ; 61(7): 783-790, 2019 07.
Article in English | MEDLINE | ID: mdl-30320442

ABSTRACT

AIM: This cross-sectional investigation evaluated whether recurrent botulinum neurotoxin A (BoNT-A) interventions to the medial gastrocnemius have an influence on muscle morphology, beyond Gross Motor Function Classification System (GMFCS) level. METHOD: A cohort of typically developing children (n=67; 43 males, 24 females; median age 9y 11mo [range 7y 10mo-11y 6mo]), a cohort of children with spastic cerebral palsy (CP) naive to BoNT-A interventions (No-BoNT-A; n=19; 10 males, nine females; median age 9y 3mo [range 8y 5mo-10y 10mo]) and a cohort of children with spastic CP with a minimum of three recurrent BoNT-A interventions to the medial gastrocnemius (BoNT-A; n=19; 13 males, six females; median age 9y 8mo [range 7y 3mo-10y 7mo]) were recruited. Three-dimensional freehand ultrasound was used to estimate medial gastrocnemius volume normalized to body mass and echo-intensity. RESULTS: Normalized medial gastrocnemius volume and echo-intensity significantly differed between the two spastic CP cohorts (p≤0.05), with the BoNT-A cohort having larger alterations. Associations between normalized medial gastrocnemius volume and echo-intensity were highest in the No-BoNT-A cohort, followed by the BoNT-A cohort. Multiple regression analyses revealed that both GMFCS level and BoNT-A intervention history were significantly associated with smaller normalized medial gastrocnemius volume and higher echo-intensity. INTERPRETATION: Recurrent BoNT-A interventions may induce alterations to medial gastrocnemius volume and echo-intensity beyond the natural history of the spastic CP pathology. WHAT THIS PAPER ADDS: In spastic cerebral palsy, medial gastrocnemius volumes are smaller and echo-intensities higher compared with typical development. Alterations after botulinum neurotoxin A intervention (BoNT-A) are larger than in no BoNT-A intervention. Gross Motor Function Classification System level and BoNT-A history significantly associate with medial gastrocnemius and echo-intensity alterations.


VOLUMEN DEL MÚSCULO GASTROCNEMIUS MEDIAL E INTENSIDAD DE LA ECOGRAFÍA DESPUÉS DE LA COLOCACIÓN DE NEUROTOXINA BOTULÍNICA (TIPO A), EN NIÑOS CON PARÁLISIS CEREBRAL ESPÁSTICA (PC): OBJETIVO: Esta investigación de corte transversal evaluó si la colocación recurrente de neurotoxina botulínica tipo A (BoNT-A) en el músculo gastrocnemius medial tienen una influencia en la morfología muscular, más allá del nivel del Sistema de Clasificación de la Función Motora Gruesa (GMFCS, siglas en ingles). MÉTODO: Una cohorte de niños con desarrollo tipico (n = 67; 43 varones, 24 mujeres; mediana de edad 9 años 11 meses [rango 7 años 10 meses -11 años 6 meses]), otra cohorte de niños con parálisis cerebral espástica (PC) que no habían recibido intervenciones de BoNT-A ( n = 19; 10 hombres, nueve mujeres; mediana de edad 9 años 3 meses [rango 8 años 5 meses -10 años 10 meses]) y una cohorte de niños con PC espástica con un mínimo de tres administraciones recurrentes de BoNT-A en el músculo gastrocnemius medial (BoNT-A; n = 19; 13 varones, seis mujeres; mediana de edad 9 años 8 meses [rango 7 años 3 meses - 10 años 7 meses]) fueron reclutados. Se usó ultrasonido tridimensional a mano alzada para estimar el volumen del músculo gastrocnemius medial normalizado a la masa corporal y la intensidad del eco. RESULTADOS: El volumen del músculo gastrocnemius medial normalizado y la intensidad del eco difirieron significativamente entre las dos cohortes de PC espástica (p≤0,05), la cohorte BoNT-A tuvo alteraciones mayores. Las asociaciones entre el volumen músculo gastrocnemius medial normalizado y la intensidad del eco fueron más altas en la cohorte No-BoNT-A, seguidas de la cohorte BoNT-A. Los análisis de regresión múltiple revelaron que tanto el nivel de GMFCS como el antecedente de intervención de BoNT-A se asociaron significativamente con un volumen del músculo gastrocnemius medial normalizado más pequeño y una mayor intensidad de eco. INTERPRETACIÓN: La colocación recurrentes de BoNT-A pueden inducir alteraciones en el volumen del músculo gastrocnemius medial y en la intensidad del eco más allá de la historia natural de la patología por PC espástica.


VOLUME E ECO-INTENSIDADE DO MÚSCULO GASTROCNÊMIO MEDIAL APÓS INTERVENÇÕES COM NEUROTOXINA BOTULÍNICA A EM CRIANÇAS COM PARALISIA CEREBRAL ESPÁSTICA: OBJETIVO: Esta investigação transversal avaliou se intervenções recorrentes com neurotoxina botulínica A (NTBo-A) no músculo gastrocnêmio medial têm influência na morfologia muscular, além do nível segundo o Sistema de Classificação da Função Motora Grossa (GMFCS). MÉTODO: Uma coorte de crianças com desenvolvimento típico (n=67; 43 do sexo masculino, 24 do sexo feminino; idade mediana 9a 11m [variação 7a 10m-11a 6m]), uma coorte de crianças com paralisia cerebral espástica (PC) que nunca recebeu intervenções com NTBo-A (No-NTBo-A; n=19; 10 do sexo masculino, nove do sexo feminino; idade mediana 9a 3m [variação 8a 5m-10a 10m]) e uma coorte de crianças com PC espástica com no mínimo três intervenções de NTBo-A no músculo gastrocnêmio medial (NTBo-A; n=19; 13 do sexo mascuino, seis do sexo feminino; idade mediana 9a 8m [variação 7a 3m-10a 7m]) foram recrutadas. Ultrassom tridimensional foi usado para estimar o volume do gastrocnêmio normalizado para a massa corporal e eco-intensidade. RESULTADOS: O volume normalizado e eco-intensidade do músculo gastrocnêmio medial diferiu significantemente entre as duas coortes de PC espástica (p≤0,05), com a coorte NTBo-A tendo maiores alteracões. Associações entre o volume normalizado do gastrocnêmio e eco-intensidade foram maiores na coorte No-NTBo-A, seguida pela coorte NTBo-A. Análises de regressão múltipla revelaram que tanto o nível GMFCS quanto a história de intervenção com NTBo-A foram significativamente associadas com menor volume normalizado do músculo gastrocnêmio medial e maior eco-intensidade. INTERPRETAÇÃO: Intervenções recorrentes com NTBo-A podem induzir alterações no volume e eco-intensidade do músculo gastrocnêmio medial, além da história natural da patologia da PC espástica.


Subject(s)
Botulinum Toxins, Type A/administration & dosage , Cerebral Palsy/drug therapy , Muscle Spasticity/drug therapy , Muscle, Skeletal/drug effects , Muscle, Skeletal/pathology , Neuromuscular Agents/administration & dosage , Cerebral Palsy/complications , Cerebral Palsy/pathology , Cerebral Palsy/physiopathology , Child , Cohort Studies , Female , Humans , Imaging, Three-Dimensional , Injections, Intramuscular , Leg , Male , Muscle Spasticity/etiology , Muscle Spasticity/pathology , Muscle Spasticity/physiopathology , Muscle, Skeletal/diagnostic imaging , Organ Size , Treatment Outcome , Ultrasonography
14.
Front Pediatr ; 6: 259, 2018.
Article in English | MEDLINE | ID: mdl-30338247

ABSTRACT

Stretch reflex hyperactivity in the gastrocnemius of children with spastic cerebral palsy (CP) is commonly evaluated by passively rotating the ankle joint into dorsiflexion at different velocities, such as applied in conventional clinical spasticity assessments. However, surface electromyography (sEMG) collected from the medial gastrocnemius (MG) during such examination reveals unexplained heterogeneity in muscle activation between patients. Recent literature also highlights altered muscle tensile behavior in children with spastic CP. We aimed to document MG muscle and tendon lengthening during passive ankle motion at slow and fast velocity and explore its interdependence with the elicited hyperactive stretch reflex. The ankle of 15 children with CP (11 ± 3 years, GMFCS 9I 6II, 8 bilateral, 7 unilateral) and 16 typically developing children (TDC) was passively rotated over its full range of motion at slow and fast velocity. Ultrasound, synchronized with motion-analysis, was used to track the movement of the MG muscle-tendon junction and extract the relative lengthening of muscle and tendon during joint rotation. Simultaneously, MG sEMG was measured. Outcome parameters included the angular and muscle lengthening velocities 30 ms before EMG onset and the gain in root mean square EMG during stretch, as a measure of stretch reflex activity. Compared to slow rotation, the muscle lengthened less and stretch reflex activity was higher during fast rotation. These velocity-induced changes were more marked in CP compared to TDC. In the CP group, muscle-lengthening velocity had higher correlation coefficients with stretch reflex hyperactivity than joint angular velocity. Muscles with greater relative muscle lengthening during slow rotation had earlier and stronger stretch reflexes during fast rotation. These initial results suggest that ankle angular velocity is not representative of MG muscle lengthening velocity and is less related to stretch reflex hyperactivity than MG muscle lengthening. In addition, muscles that lengthened more during slow joint rotation were more likely to show a velocity-dependent stretch reflex. This interdependence of muscle lengthening and stretch reflexes may be important to consider when administering treatment. However, muscle and tendon lengthening properties alone could not fully explain the variability in stretch reflexes, indicating that other factors should also be investigated.

15.
Ultrasound Med Biol ; 44(12): 2505-2518, 2018 12.
Article in English | MEDLINE | ID: mdl-30172570

ABSTRACT

Ultrasound imaging modalities offer a clinically viable method to visualize musculoskeletal structures. However, proper data comparison between investigations is compromised because of a lack of measurement error documentation and method standardization. This investigation analyzes the reliability and validity of extracting medial gastrocnemius belly and fascicle lengths and pennation angles in different ankle joint positions, across the full range of motion, in a cohort of 11 children with spastic cerebral palsy and 11 typically developed children. Each of these parameters was extracted from two consecutive acquisitions, using both 2-D and 3-D ultrasound images. The findings suggest that the muscle tendon junction extraction in 2-D images can be a suitable parameter for analyzing medial gastrocnemius muscle length in typically developed children and children with spastic cerebral palsy, although averaging over multiple measurements is recommended to reduce variability. More caution should be taken when performing analyses based on fascicle length.


Subject(s)
Achilles Tendon/physiopathology , Ankle Joint/physiopathology , Imaging, Three-Dimensional/methods , Muscle, Skeletal/physiopathology , Range of Motion, Articular/physiology , Ultrasonography/methods , Achilles Tendon/diagnostic imaging , Belgium , Child , Cohort Studies , Female , Humans , Male , Muscle, Skeletal/diagnostic imaging , Reproducibility of Results
16.
Exp Physiol ; 103(10): 1367-1376, 2018 10.
Article in English | MEDLINE | ID: mdl-30091806

ABSTRACT

NEW FINDINGS: What is the central question of this study? Which structures of the medial gastrocnemius muscle-tendon unit contribute to its lengthening during joint rotation and thus receive the stretching stimulus? What is the main finding and its importance? We show, for the first time, that muscle and tendon lengthen in a different manner in children with cerebral palsy compared with typically developing children during a similar amount of muscle-tendon unit lengthening or joint rotation. This indicates possible differences in mechanical muscle and tendon properties attributable to cerebral palsy, which are not evident by assessment of muscle function at the level of a joint. ABSTRACT: Children with cerebral palsy (CP) commonly present with reduced ankle range of motion (ROM) attributable, in part, to changes in mechanical properties of the muscle-tendon unit (MTU). Detailed information about how muscle and tendon interact to contribute to joint rotation is currently lacking but might provide essential information to explain the limited effectiveness of stretching interventions in children with CP. The purpose of this study was to quantify which structures contribute to MTU lengthening and thus receive the stretch during passive ankle joint rotation. Fifteen children with CP (age, in mean ± SD, 11.4 ± 3 years) and 16 typically developing (TD) children (age, in mean ± SD, 10.2 ± 3 years) participated. Ultrasound was combined with motion tracking, joint torque and EMG to record fascicle, muscle and tendon lengthening of the medial gastrocnemius during passive ankle joint rotations over the full ROM and a common ROM. In children with CP, relative to MTU lengthening, muscle and fascicles lengthened less (CP, 50.4% of MTU lengthening; TD, 63% of MTU lengthening; P < 0.04) and tendon lengthened more (CP, 49.6% of MTU lengthening; TD, 37% of MTU lengthening; P < 0.01) regardless of the ROM studied. Differences between groups in the amount of lengthening of the underlying structures during a similar amount of joint rotation and MTU displacement indicate possible differences in tissue mechanical properties attributable to CP, which are not evident by assessment at the level of a joint. These factors should be considered when assessing and treating muscle function in children with CP, for example during stretching exercises, because the muscle might not receive much of the applied lengthening stimulus.


Subject(s)
Ankle Joint/physiopathology , Cerebral Palsy/physiopathology , Muscle, Skeletal/physiopathology , Tendons/physiopathology , Ankle/physiopathology , Child , Female , Humans , Male , Range of Motion, Articular/physiology , Rotation , Torque , Ultrasonography/methods
17.
J Biomech ; 77: 194-200, 2018 08 22.
Article in English | MEDLINE | ID: mdl-29935732

ABSTRACT

BACKGROUND: 3D freehand ultrasound enables the creation of volumetric data. The acquisition of morphological features, such as muscle volume, is influenced by the variations in force applied to the skin with the ultrasound probe. To minimise the deformations, a concave-shaped plastic mount combined with a custom-shaped gel pad was developed for the ultrasound head, named Portico. This study analyses to what extent the Portico reduces muscle deformation and corresponding errors in estimating muscle volume. METHOD: Twenty medial gastrocnemius (MG) muscles were assessed (10 from typically developing children; 10 from children with spastic cerebral palsy). Two repetitions were acquired in each of the following approaches: (1) with the lower leg submerged in a water tank as a non-deformed reference; (2) probe-on-skin (PoS) as the conventional approach and (3) the newly introduced Portico. PoS and Portico data were registered with respect to the ones corresponding in a water tank. An in-house software package (Py3DFreeHandUS) was used to process the data and MG volume was estimated using MeVisLab. The minimal detectable change (MDC) was calculated. RESULTS: With respect to the PoS approach, the Portico reduced muscle deformation by 46%. For both the typically developing and spastic cerebral palsy cohorts, lower MDCs were found when using the Portico. DISCUSSION: Despite the improvements, the Portico did not yield statistically more reliable MG volume estimations than the traditional PoS approach. Further improvement can be attained by optimising the fit between the gel pad and the curvature of the limb, using a larger choice of Portico geometries.


Subject(s)
Artifacts , Imaging, Three-Dimensional/methods , Muscle, Skeletal/diagnostic imaging , Cerebral Palsy/diagnostic imaging , Child , Female , Humans , Male , Ultrasonography
18.
Comput Methods Programs Biomed ; 156: 97-103, 2018 Mar.
Article in English | MEDLINE | ID: mdl-29428080

ABSTRACT

BACKGROUND AND OBJECTIVE: 3D freehand Ultrasonography is a medical imaging technique that can be used to measure muscle and tendon morphological and structural properties, including volume, lengths and echo-intensity. These properties are clinically relevant in neurological disorders such as spastic cerebral palsy to monitor disease progression and evaluate the effect of treatment. This study presents a methodology for extracting these parameters along with a clinical reliability analysis for the data acquisition and processing. METHODS: The medial gastrocnemius muscles and Achilles tendon of 10 typically developing children and 10 children with spastic cerebral palsy were assessed. An open-source in-house software library developed in Python (Py3DFreeHandUS) was used to reconstruct, into one 3D data set, the data simultaneously acquired from an US machine and a motion tracking system. US images were manually segmented and linearly interpolated by means of a new simplified approach which involved sequentially decreasing the total number of images used for muscle border segmentation from 100% to 5%. Acquisition and processing reliability was defined based on repeated measures from different data processers and from different data acquirers, respectively. RESULTS: When only 10% of the US images were outlined, there was an average underestimation of muscle volume of 1.1% and 1.6% with respect the computation of all the available images, for the typically developing and spastic cerebral palsy groups, respectively. For both groups, the reliability was higher for data processing than for data acquisition. High inter-class correlation coefficient values were found for processing and acquisition reliability, with worst case values of 0.89 and 0.61, respectively. The standard error of measurement, expressed as a percentage of the average volumes, was smaller than 2.6 ml (4.8%) in all cases. CONCLUSIONS: The present analysis demonstrates the effectiveness of applying 3D freehand ultrasonography in a clinical setting for analysing healthy and pathological paediatric muscle.


Subject(s)
Imaging, Three-Dimensional/methods , Muscle, Skeletal/diagnostic imaging , Ultrasonography/methods , Adolescent , Ankle Joint/physiology , Case-Control Studies , Cerebral Palsy , Child , Female , Humans , Image Processing, Computer-Assisted , Machine Learning , Male , Motion , Observer Variation , Reference Values , Reproducibility of Results , Tendons
19.
Dev Med Child Neurol ; 60(1): 81-87, 2018 01.
Article in English | MEDLINE | ID: mdl-29067675

ABSTRACT

AIM: This cross-sectional investigation evaluates the reliability of estimating medial gastrocnemius anatomical cross-sectional area (aCSA) in typically developing and spastic cerebral palsy (SCP) cohorts. It verifies whether muscle volume estimations based on aCSA improve when aCSA is multiplied by muscle-tendon unit (MTU) or muscle length, and whether the resulting errors in volume estimations are smaller than changes after intervention. METHOD: Fifteen typically developing children (mean age 8y 2mo [SD 1y 5mo], six males, nine females) and 30 children with SCP (mean age 9y 2mo [SD 2y 5mo], 22 males, eight females, Gross Motor Function Classification System [GMFCS] level I=15, II=15) participated in the investigation. The SCP cohort was divided according to GMFCS level. A three-dimensional freehand ultrasound technique was used to estimate medial gastrocnemius aCSA, muscle volume, MTU, and muscle length. Estimated muscle volume (aCSA×MTU or muscle length) was compared with the measured muscle volume. RESULTS: Anatomical cross-sectional area, muscle volume, and muscle length significantly differed between the typically developing and two SCP cohorts (p≤0.050). aCSA multiplied by either MTU or muscle length improved estimations of medial gastrocnemius volume. Leave-one-out cross-validation revealed an absolute difference with measured muscle volume of 3.77 ml (SD 2.90). INTERPRETATION: This investigation revealed that medial gastrocnemius muscle volume can be reliably estimated in a clinically feasible manner in typically developing children and those with SCP. WHAT THIS PAPER ADDS: Medial gastrocnemius anatomical cross-sectional area (aCSA) can be reliably estimated in children with spastic cerebral palsy. The location of the anatomical cross-section should be taken with respect to muscle and not bone length. Medial gastrocnemius volume can be reliably estimated by multiplying aCSA and muscle length. The errors in volume estimations are smaller than reported differences after interventions.


Subject(s)
Cerebral Palsy/diagnostic imaging , Muscle, Skeletal/diagnostic imaging , Ultrasonography/methods , Child , Cross-Sectional Studies , Female , Humans , Male
20.
Ultrasound Med Biol ; 44(1): 110-118, 2018 Jan.
Article in English | MEDLINE | ID: mdl-29122315

ABSTRACT

A clinically feasible method to reliably estimate muscle-tendon unit (MTU) lengths could provide essential diagnostic and treatment planning information. A 3-D freehand ultrasound (3-DfUS) method was previously validated for extracting in vivo medial gastrocnemius (MG) lengths, although the processing time can be considered substantial for the clinical environment. This investigation analyzed a quicker and simpler method using the US transducer as a spatial pointer (US-PaP), where the within-session reliability of extracting the muscle-tendon unit (MTU) and tendon lengths are estimated. MG MTU lengths were extracted in a group of 14 healthy adults using both 3-DfUS and US-PaP. Two consecutive acquisitions were performed per participant, and the data processed by two researchers independently. The intra-class correlation coefficients were above 0.97, and the standard error of measurements below 3.6 mm (1.5%). This investigation proposes that the simplified US-PaP method is a viable alternative for estimating MG MTU lengths.


Subject(s)
Body Weights and Measures/methods , Imaging, Three-Dimensional/methods , Muscle, Skeletal/anatomy & histology , Tendons/anatomy & histology , Ultrasonography/methods , Adult , Female , Humans , Male , Reference Values , Reproducibility of Results , Transducers , Ultrasonography/instrumentation , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL