Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 4 de 4
1.
JMIR Res Protoc ; 13: e57329, 2024 Apr 26.
Article En | MEDLINE | ID: mdl-38669065

BACKGROUND: Relative motion between the residual limb and socket in individuals with transtibial limb loss can lead to substantial consequences that limit mobility. Although assessments of the relative motion between the residual limb and socket have been performed, there remains a substantial gap in understanding the complex mechanics of the residual limb-socket interface during dynamic activities that limits the ability to improve socket design. However, dynamic stereo x-ray (DSX) is an advanced imaging technology that can quantify 3D bone movement and skin deformation inside a socket during dynamic activities. OBJECTIVE: This study aims to develop analytical tools using DSX to quantify the dynamic, in vivo kinematics between the residual limb and socket and the mechanism of residual tissue deformation. METHODS: A lower limb cadaver study will first be performed to optimize the placement of an array of radiopaque beads and markers on the socket, liner, and skin to simultaneously assess dynamic tibial movement and residual tissue and liner deformation. Five cadaver limbs will be used in an iterative process to develop an optimal marker setup. Stance phase gait will be simulated during each session to induce bone movement and skin and liner deformation. The number, shape, size, and placement of each marker will be evaluated after each session to refine the marker set. Once an optimal marker setup is identified, 21 participants with transtibial limb loss will be fitted with a socket capable of being suspended via both elevated vacuum and traditional suction. Participants will undergo a 4-week acclimation period and then be tested in the DSX system to track tibial, skin, and liner motion under both suspension techniques during 3 activities: treadmill walking at a self-selected speed, at a walking speed 10% faster, and during a step-down movement. The performance of the 2 suspension techniques will be evaluated by quantifying the 3D bone movement of the residual tibia with respect to the socket and quantifying liner and skin deformation at the socket-residuum interface. RESULTS: This study was funded in October 2021. Cadaver testing began in January 2023. Enrollment began in February 2024. Data collection is expected to conclude in December 2025. The initial dissemination of results is expected in November 2026. CONCLUSIONS: The successful completion of this study will help develop analytical methods for the accurate assessment of residual limb-socket motion. The results will significantly advance the understanding of the complex biomechanical interactions between the residual limb and the socket, which can aid in evidence-based clinical practice and socket prescription guidelines. This critical foundational information can aid in the development of future socket technology that has the potential to reduce secondary comorbidities that result from complications of poor prosthesis load transmission. INTERNATIONAL REGISTERED REPORT IDENTIFIER (IRRID): DERR1-10.2196/57329.


Lower Extremity , Skin , Tibia , Humans , Amputation Stumps/diagnostic imaging , Amputation Stumps/physiopathology , Artificial Limbs , Biomechanical Phenomena/physiology , Cadaver , Lower Extremity/diagnostic imaging , Lower Extremity/surgery , Lower Extremity/physiology , Movement/physiology , Skin/diagnostic imaging , Tibia/diagnostic imaging , Tibia/surgery
2.
JMIR Res Protoc ; 13: e53412, 2024 Jan 26.
Article En | MEDLINE | ID: mdl-38277197

BACKGROUND: Powered ankle-foot prosthetic devices can generate net positive mechanical work during gait, which mimics the physiological ankle. However, gait deviations can persist in individuals with transfemoral limb loss because of habit or lack of rehabilitation. Prosthetic research efforts favor the design or evaluation of prosthetic componentry and rarely incorporate any type of rehabilitation, despite evidence suggesting that it is critical for minimizing gait imbalances. Given the accelerated rate of innovation in prosthetics, there is a fundamental knowledge gap concerning how individuals with transfemoral limb loss should learn to correctly use powered ankle-foot devices for maximum functional benefit. Because of the recent advances in prosthetic technology, there is also a critical unmet need to develop guidelines for the prescription of advanced prosthetic devices that incorporate both physical and psychological components to identify appropriate candidates for advanced technology. OBJECTIVE: The primary goal of this investigation is to examine the roles of advanced prosthetic technology and a device-specific rehabilitative intervention on gait biomechanics, functional efficacy, and pain in individuals with transfemoral limb loss. The secondary goal is to develop preliminary rehabilitation guidelines for advanced lower limb prosthetic devices to minimize gait imbalances and maximize function and to establish preliminary guidelines for powered ankle-foot prosthetic prescription. METHODS: This prospective, multisite study will enroll 30 individuals with unilateral transfemoral limb loss. At baseline, participants will undergo a full gait analysis and assessment of function, neurocognition, cognitive load, subjective preferences, and pain using their current passive prosthesis. The participants will then be fitted with a powered ankle-foot device and randomized into 2 equal groups: a powered device with a device-specific rehabilitation intervention (group A) or a powered device with the current standard of practice (group B). Group A will undergo 4 weeks of device-specific rehabilitation. Group B will receive the current standard of practice, which includes basic device education but no further device-specific rehabilitation. Data collection procedures will then be repeated after 4 weeks and 8 weeks of powered ankle use. RESULTS: This study was funded in September 2017. Enrollment began in September 2018. Data collection will conclude by March 2024. The initial dissemination of results is expected in August 2024. CONCLUSIONS: The projected trends indicate that the number of individuals with limb loss will dramatically increase in the United States. The absence of effective, evidence-based interventions may make individuals with transfemoral limb loss more susceptible to increased secondary physical conditions and degenerative changes. With this expected growth, considerable resources will be required for prosthetic and rehabilitation services. Identifying potential mechanisms for correcting gait asymmetries, either through advanced prosthetic technology or rehabilitative interventions, can provide a benchmark for understanding the optimal treatment strategies for individuals with transfemoral limb loss. TRIAL REGISTRATION: ClinicalTrials.gov NCT03625921; https://clinicaltrials.gov/study/NCT03625921. INTERNATIONAL REGISTERED REPORT IDENTIFIER (IRRID): DERR1-10.2196/53412.

3.
JMIR Res Protoc ; 12: e45612, 2023 Apr 04.
Article En | MEDLINE | ID: mdl-37014672

BACKGROUND: The prescription of prosthetic ankle-foot devices is often based on the professional judgment of the limb loss care team or limited evidentiary research. Current prosthetic research efforts have focused on the design and development of prosthetic devices rather than on understanding which devices are the most appropriate to prescribe. This investigation will evaluate biomechanical, functional, and subjective outcome measures to help determine the optimal prescription parameters of prosthetic ankle-foot devices. OBJECTIVE: This study aims to develop evidence-based guidelines for limb loss care teams for the appropriate prescription of commercially available prosthetic ankle-foot devices to improve function and satisfaction. METHODS: This investigation will be a multisite, randomized, crossover clinical trial targeting the enrollment of 100 participants. Participants will use 3 different types of prosthetic devices (energy storing and returning, articulating, and powered) in random order. Participants will be fitted and trained with each device and then separately use each device for a 1-week acclimation period. Following each 1-week acclimation period, participants will be evaluated using several functional measures and subjective surveys. A random subset of participants (30/100, 30%) will also undergo full-body gait analysis, following each 1-week acclimation period, to collect biomechanical data during level ground and incline and decline walking. After all individual device evaluations, participants will be given all 3 prostheses concurrently for 4 weeks of home and community use to capture user preference. Activity monitoring and a guided interview will be used to determine overall user preference. RESULTS: The study was funded in August 2017, and data collection began in 2018. Data collection is expected to be completed before July 2023. Initial dissemination of results is expected to occur in the winter of 2023. CONCLUSIONS: By identifying biomechanical, functional, and subjective outcomes that are sensitive to differences in prosthetic ankle-foot devices, a benchmark of evidence can be developed to guide effective prosthetic prescription. TRIAL REGISTRATION: ClinicalTrials.gov NCT03505983; https://clinicaltrials.gov/ct2/show/NCT03505983. INTERNATIONAL REGISTERED REPORT IDENTIFIER (IRRID): DERR1-10.2196/45612.

4.
Front Bioeng Biotechnol ; 9: 697651, 2021.
Article En | MEDLINE | ID: mdl-34447740

Individuals with transfemoral amputation experience relative motion between their residual limb and prosthetic socket, which can cause inefficient dynamic load transmission and secondary comorbidities that limit mobility. Accurately measuring the relative position and orientation of the residual limb relative to the prosthetic socket during dynamic activities can provide great insight into the complex mechanics of the socket/limb interface. Five participants with transfemoral amputation were recruited for this study. All participants had a well-fitting, ischial containment socket and were also fit with a compression/release stabilization socket. Participants underwent an 8-wk, randomized crossover trial to compare differences between socket types. Dynamic stereo x-ray was used to quantify three-dimensional residual bone kinematics relative to the prosthetic socket during treadmill walking at self-selected speed. Comfort, satisfaction, and utility were also assessed. There were no significant differences in relative femur kinematics between socket types in the three rotational degrees of freedom, as well as anterior-posterior and medial-lateral translation (p > 0.05). The ischial containment socket demonstrated significantly less proximal-distal translation (pistoning) of the femur compared to the compression/release stabilization socket during the gait cycle (p < 0.05), suggesting that the compression/release stabilization socket provided less control of the residual femur during distal translation. No significant differences in comfort and utility were found between socket types (p > 0.05). The quantitative, dynamic analytical tools used in the study were sensitive to distinguish differences in three-dimensional residual femur motion between two socket types, which can serve as a platform for future comparative effectiveness studies of socket technology.

...