Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 64
Filter
1.
Radiol Cardiothorac Imaging ; 6(4): e230339, 2024 08.
Article in English | MEDLINE | ID: mdl-39145734

ABSTRACT

Purpose To clarify the predominant causative plaque constituent for periprocedural myocardial injury (PMI) following percutaneous coronary intervention: (a) erythrocyte-derived materials, indicated by a high plaque-to-myocardium signal intensity ratio (PMR) at coronary atherosclerosis T1-weighted characterization (CATCH) MRI, or (b) lipids, represented by a high maximum 4-mm lipid core burden index (maxLCBI4 mm) at near-infrared spectroscopy intravascular US (NIRS-IVUS). Materials and Methods This retrospective study included consecutive patients who underwent CATCH MRI before elective NIRS-IVUS-guided percutaneous coronary intervention at two facilities. PMI was defined as post-percutaneous coronary intervention troponin T values greater than five times the upper reference limit. Multivariable analysis was performed to identify predictors of PMI. Finally, the predictive capabilities of MRI, NIRS-IVUS, and their combination were compared. Results A total of 103 lesions from 103 patients (median age, 72 years [IQR, 64-78]; 78 male patients) were included. PMI occurred in 36 lesions. In multivariable analysis, PMR emerged as the strongest predictor (P = .001), whereas maxLCBI4 mm was not a significant predictor (P = .07). When PMR was excluded from the analysis, maxLCBI4 mm emerged as the sole independent predictor (P = .02). The combination of MRI and NIRS-IVUS yielded the largest area under the receiver operating curve (0.86 [95% CI: 0.64, 0.83]), surpassing that of NIRS-IVUS alone (0.75 [95% CI: 0.64, 0.83]; P = .02) or MRI alone (0.80 [95% CI: 0.68, 0.88]; P = .30). Conclusion Erythrocyte-derived materials in plaques, represented by a high PMR at CATCH MRI, were strongly associated with PMI independent of lipids. MRI may play a crucial role in predicting PMI by offering unique pathologic insights into plaques, distinct from those provided by NIRS. Keywords: Coronary Plaque, Periprocedural Myocardial Injury, MRI, Near-Infrared Spectroscopy Intravascular US Supplemental material is available for this article. © RSNA, 2024.


Subject(s)
Percutaneous Coronary Intervention , Plaque, Atherosclerotic , Spectroscopy, Near-Infrared , Humans , Male , Female , Spectroscopy, Near-Infrared/methods , Aged , Plaque, Atherosclerotic/diagnostic imaging , Retrospective Studies , Middle Aged , Magnetic Resonance Imaging/methods , Coronary Artery Disease/diagnostic imaging , Predictive Value of Tests , Ultrasonography, Interventional/methods , Coronary Vessels/diagnostic imaging , Coronary Vessels/pathology , Heart Injuries/diagnostic imaging , Heart Injuries/pathology
2.
Magn Reson Med ; 2024 Aug 22.
Article in English | MEDLINE | ID: mdl-39171431

ABSTRACT

PURPOSE: Radiotherapy treatment planning (RTP) using MR has been used increasingly for the abdominal site. Multiple contrast weightings and motion-resolved imaging are desired for accurate delineation of the target and various organs-at-risk and patient-tailored planning. Current MR protocols achieve these through multiple scans with distinct contrast and variable respiratory motion management strategies and acquisition parameters, leading to a complex and inaccurate planning process. This study presents a standalone MR Multitasking (MT)-based technique to produce volumetric, motion-resolved, multicontrast images for abdominal radiotherapy treatment planning. METHODS: The MT technique resolves motion and provides a wide range of contrast weightings by repeating a magnetization-prepared (saturation recovery and T2 preparations) spoiled gradient-echo readout series and adopting the MT image reconstruction framework. The performance of the technique was assessed through digital phantom simulations and in vivo studies of both healthy volunteers and patients with liver tumors. RESULTS: In the digital phantom study, the MT technique presented structural details and motion in excellent agreement with the digital ground truth. The in vivo studies showed that the motion range was highly correlated (R2 = 0.82) between MT and 2D cine imaging. MT allowed for a flexible contrast-weighting selection for better visualization. Initial clinical testing with interobserver analysis demonstrated acceptable target delineation quality (Dice coefficient = 0.85 ± 0.05, Hausdorff distance = 3.3 ± 0.72 mm). CONCLUSION: The developed MT-based, abdomen-dedicated technique is capable of providing motion-resolved, multicontrast volumetric images in a single scan, which may facilitate abdominal radiotherapy treatment planning.

3.
J Magn Reson Imaging ; 2024 Aug 14.
Article in English | MEDLINE | ID: mdl-39143805

ABSTRACT

BACKGROUND: The rotating Cartesian k-space multiphase steady-state imaging with contrast (ROCK-MUSIC) pulse sequence enables acquisition of whole-heart, cardiac phase-resolved images in pediatric congenital heart disease (CHD) without reliance on the ventilator gating signal. Multidimensional reconstruction with low rank tensor (LRT) has shown promise for resolving complex cardiorespiratory motion. PURPOSE: To enhance ROCK-MUSIC by resolving cardiorespiratory phases using LRT reconstruction and to enable semi-automatic hyperparameter tuning by developing an image quality scoring model. STUDY TYPE: Retrospective. POPULATION: Thirty patients (45% female, age 2 days to 6.7 years) with CHD. FIELD STRENGTH/SEQUENCE: 3-T, four-dimensional (4D) spoiled gradient recalled echo sequence. ASSESSMENT: Eigenvector-based iTerative Self-consistent Parallel Imaging Reconstruction (ESPIRiT) served as the reference comparison for LRT reconstruction. A 4-point Likert scale was used for cardiac and vascular image quality scoring based on cardiac chamber definition, lumen signal uniformity, vascular margin clarity, and motion artifact. Ejection fraction and ventricular volumes were assessed in 16 patients. Signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and edge sharpness were computed. STATISTICAL TESTS: Intraclass correlation coefficients, Wilcoxon signed-rank test, Bland-Altman. A P-value <0.05 was considered statistically significant. RESULTS: Relative to ESPIRiT, LRT images received significantly higher cardiac (2.81 ± 0.57 vs. 3.19 ± 0.54) and vascular (2.81 ± 0.60 vs. 3.36 ± 0.53) image quality scores. Image quality scoring with semi-automated hyperparameter tuning showed strong correlations (R2 = 0.748) among image quality, SNR, and septal sharpness. Comparison of ejection fraction and volumetry derived from ESPIRiT, and LRT showed no significant systematic difference (P = 0.32). DATA CONCLUSION: Integration of low-rank reconstruction with ROCK-MUSIC acquisition may be feasible, and semi-automatic hyperparameter tuning could be effective for generating cardiorespiratory resolved images. LEVEL OF EVIDENCE: 2 TECHNICAL EFFICACY: Stage 1.

4.
Magn Reson Med ; 2024 Jul 16.
Article in English | MEDLINE | ID: mdl-39014982

ABSTRACT

PURPOSE: To develop a self-supervised learning method to retrospectively estimate T1 and T2 values from clinical weighted MRI. METHODS: A self-supervised learning approach was constructed to estimate T1, T2, and proton density maps from conventional T1- and T2-weighted images. MR physics models were employed to regenerate the weighted images from the network outputs, and the network was optimized based on loss calculated between the synthesized and input weighted images, alongside additional constraints based on prior information. The method was evaluated on healthy volunteer data, with conventional mapping as references. The reproducibility was examined on two 3.0T scanners. Performance in tumor characterization was inspected by applying the method to a public glioblastoma dataset. RESULTS: For T1 and T2 estimation from three weighted images (T1 MPRAGE, T1 gradient echo sequences, and T2 turbo spin echo), the deep learning method achieved global voxel-wise error ≤9% in brain parenchyma and regional error ≤12.2% in six types of brain tissues. The regional measurements obtained from two scanners showed mean differences ≤2.4% and correlation coefficients >0.98, demonstrating excellent reproducibility. In the 50 glioblastoma patients, the retrospective quantification results were in line with literature reports from prospective methods, and the T2 values were found to be higher in tumor regions, with sensitivity of 0.90 and specificity of 0.92 in a voxel-wise classification task between normal and abnormal regions. CONCLUSION: The self-supervised learning method is promising for retrospective T1 and T2 quantification from clinical MR images, with the potential to improve the availability of quantitative MRI and facilitate brain tumor characterization.

5.
PLoS One ; 19(7): e0303957, 2024.
Article in English | MEDLINE | ID: mdl-38950083

ABSTRACT

BACKGROUND: The placenta is a transient organ critical for fetal development. Disruptions of normal placental functions can impact health throughout an individual's entire life. Although being recognized by the NIH Human Placenta Project as an important organ, the placenta remains understudied, partly because of a lack of non-invasive tools for longitudinally evaluation for key aspects of placental functionalities. OBJECTIVE: Our goal is to create a non-invasive preclinical imaging pipeline that can longitudinally probe murine placental health in vivo. We use advanced imaging processing schemes to establish functional biomarkers for non-invasive longitudinal evaluation of placental development. METHODOLOGY: We implement dynamic contrast enhancement magnetic resonance imaging (DCE-MRI) and analysis pipeline to quantify uterine contraction and placental perfusion dynamics. We use optic flow and time-frequency analysis to quantify and characterize contraction-related placental motion. Our novel imaging and analysis pipeline uses subcutaneous administration of gadolinium for steepest slope-based perfusion evaluation, enabling non-invasive longitudinal monitoring. RESULTS: We demonstrate that the placenta exhibits spatially asymmetric contractile motion that develops from E14.5 to E17.5. Additionally, we see that placental perfusion, perfusion delivery rate, and substrate delivery all increase from E14.5 to E17.5, with the High Perfusion Chamber (HPC) leading the placental changes that occur from E14.5 to E17.5. DISCUSSION: We advance the placental perfusion chamber paradigm with a novel, physiologically based threshold model for chamber localization and demonstrate spatially varying placental chambers using multiple functional metrics that assess mouse placental development and remodeling throughout gestation. CONCLUSION: Our pipeline enables the non-invasive, longitudinal assessment of multiple placenta functions from a single imaging session. Our pipeline serves as a key toolbox for advancing research in mouse models of placental disease and disorder.


Subject(s)
Contrast Media , Magnetic Resonance Imaging , Placenta , Uterine Contraction , Animals , Female , Pregnancy , Magnetic Resonance Imaging/methods , Mice , Placenta/diagnostic imaging , Placenta/blood supply , Uterine Contraction/physiology , Mice, Inbred C57BL
6.
Radiat Res ; 2024 Jul 30.
Article in English | MEDLINE | ID: mdl-39074819

ABSTRACT

Victims of a radiation terrorist event will include pregnant women and unborn fetuses. Mitochondrial dysfunction and oxidative stress are key pathogenic factors of fetal radiation injury. The goal of this preclinical study is to investigate the efficacy of mitigating fetal radiation injury by maternal administration of the mitochondrial-targeted gramicidin S (GS)-nitroxide radiation mitigator JP4-039. Pregnant female C57BL/6NTac mice received 3 Gy total-body irradiation (TBI) at mid-gestation embryonic day 13.5 (E13.5). Using novel time-and-motion-resolved 4D in utero magnetic resonance imaging (4D-uMRI), we found TBI caused extensive injury to the fetal brain that included cerebral hemorrhage, loss of cerebral tissue, and hydrocephalus with excessive accumulation of cerebrospinal fluid (CSF). Histopathology of the fetal mouse brain showed broken cerebral vessels and elevated apoptosis. Further use of novel 4D Oxy-wavelet MRI capable of probing in vivo mitochondrial function in intact brain revealed a significant reduction of mitochondrial function in the fetal brain after 3 Gy TBI. This was validated by ex vivo Oroboros mitochondrial respirometry. One day after TBI (E14.5) maternal administration of JP4-039, which passes through the placenta, significantly reduced fetal brain radiation injury and improved fetal brain mitochondrial respiration. Treatment also preserved cerebral brain tissue integrity and reduced cerebral hemorrhage and cell death. JP4-039 administration following irradiation resulted in increased survival of pups. These findings indicate that JP4-039 can be deployed as a safe and effective mitigator of fetal radiation injury from mid-gestational in utero ionizing radiation exposure.

7.
J Magn Reson Imaging ; 2024 May 06.
Article in English | MEDLINE | ID: mdl-38708951

ABSTRACT

BACKGROUND: Irregular cardiac motion can render conventional segmented cine MRI nondiagnostic. Clustering has been proposed for cardiac motion binning and may be optimized for complex arrhythmias. PURPOSE: To develop an adaptive cluster optimization method for irregular cardiac motion, and to generate the corresponding time-resolved cine images. STUDY TYPE: Prospective. SUBJECTS: Thirteen with atrial fibrillation, four with premature ventricular contractions, and one patient in sinus rhythm. FIELD STRENGTH/SEQUENCE: Free-running balanced steady state free precession (bSSFP) with sorted golden-step, reference real-time sequence. ASSESSMENT: Each subject underwent both the sorted golden-step bSSFP and the reference Cartesian real-time imaging. Golden-step bSSFP images were reconstructed using the dynamic regularized adaptive cluster optimization (DRACO) method and k-means clustering. Image quality (4-point Likert scale), signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), edge sharpness, and ventricular function were assessed. STATISTICAL TESTS: Paired t-tests, Friedman test, regression analysis, Fleiss' Kappa, Bland-Altman analysis. Significance level P < 0.05. RESULTS: The DRACO method had the highest percent of images with scores ≥3 (96% for diastolic frame, 93% for systolic frame, and 93% for multiphase cine) and the percentages were significantly higher compared with both the k-means and real-time methods. Image quality scores, SNR, and CNR were significantly different between DRACO vs. k-means and between DRACO vs. real-time. Cardiac function analysis showed no significant differences between DRACO vs. the reference real-time. CONCLUSION: DRACO with time-resolved reconstruction generated high quality images and has early promise for quantitative cine cardiac MRI in patients with complex arrhythmias including atrial fibrillation. TECHNICAL EFFICACY: Stage 2.

8.
Magn Reson Med ; 92(4): 1421-1439, 2024 Oct.
Article in English | MEDLINE | ID: mdl-38726884

ABSTRACT

PURPOSE: To develop a novel low-rank tensor reconstruction approach leveraging the complete acquired data set to improve precision and repeatability of multiparametric mapping within the cardiovascular MR Multitasking framework. METHODS: A novel approach that alternated between estimation of temporal components and spatial components using the entire data set acquired (i.e., including navigator data and imaging data) was developed to improve reconstruction. The precision and repeatability of the proposed approach were evaluated on numerical simulations, 10 healthy subjects, and 10 cardiomyopathy patients at multiple scan times for 2D myocardial T1/T2 mapping with MR Multitasking and were compared with those of the previous navigator-derived fixed-basis approach. RESULTS: In numerical simulations, the proposed approach outperformed the previous fixed-basis approach with lower T1 and T2 error against the ground truth at all scan times studied and showed better motion fidelity. In human subjects, the proposed approach showed no significantly different sharpness or T1/T2 measurement and significantly improved T1 precision by 20%-25%, T2 precision by 10%-15%, T1 repeatability by about 30%, and T2 repeatability by 25%-35% at 90-s and 50-s scan times The proposed approach at the 50-s scan time also showed comparable results with that of the previous fixed-basis approach at the 90-s scan time. CONCLUSION: The proposed approach improved precision and repeatability for quantitative imaging with MR Multitasking while maintaining comparable motion fidelity, T1/T2 measurement, and septum sharpness and had the potential for further reducing scan time from 90 s to 50 s.


Subject(s)
Algorithms , Humans , Reproducibility of Results , Male , Female , Image Interpretation, Computer-Assisted/methods , Adult , Image Enhancement/methods , Middle Aged , Sensitivity and Specificity , Image Processing, Computer-Assisted/methods , Cardiomyopathies/diagnostic imaging , Multiparametric Magnetic Resonance Imaging/methods , Heart/diagnostic imaging
9.
bioRxiv ; 2024 Feb 14.
Article in English | MEDLINE | ID: mdl-38405696

ABSTRACT

Victims of a radiation terrorist event will include pregnant women and unborn fetuses. Mitochondrial dysfunction and oxidative stress are key pathogenic factors of fetal irradiation injury. The goal of this preclinical study is to investigate the efficacy of mitigating fetal irradiation injury by maternal administration of the mitochondrial-targeted gramicidin S (GS)- nitroxide radiation mitigator, JP4-039. Pregnant female C57BL/6NTac mice received 3 Gy total body ionizing irradiation (TBI) at mid-gestation embryonic day 13.5 (E13.5). Using novel time- and-motion-resolved 4D in utero magnetic resonance imaging (4D-uMRI), we found TBI caused extensive injury to the fetal brain that included cerebral hemorrhage, loss of cerebral tissue, and hydrocephalus with excessive accumulation of cerebrospinal fluid (CSF). Histopathology of the fetal mouse brain showed broken cerebral vessels and elevated apoptosis. Further use of novel 4D Oxy-wavelet MRI capable of probing in vivo mitochondrial function in intact brain revealed significant reduction of mitochondrial function in the fetal brain after 3Gy TBI. This was validated by ex vivo Oroboros mitochondrial respirometry. Maternal administration JP4-039 one day after TBI (E14.5), which can pass through the placental barrier, significantly reduced fetal brain radiation injury and improved fetal brain mitochondrial respiration. This also preserved cerebral brain tissue integrity and reduced cerebral hemorrhage and cell death. As JP4-039 administration did not change litter sizes or fetus viability, together these findings indicate JP4-039 can be deployed as a safe and effective mitigator of fetal radiation injury from mid-gestational in utero ionizing radiation exposure. One Sentence Summary: Mitochondrial-targeted gramicidin S (GS)-nitroxide JP4-039 is safe and effective radiation mitigator for mid-gestational fetal irradiation injury.

10.
NMR Biomed ; 37(4): e5091, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38196195

ABSTRACT

BACKGROUND: Despite the widespread use of cine MRI for evaluation of cardiac function, existing real-time methods do not easily enable quantification of ventricular function. Moreover, segmented cine MRI assumes periodicity of cardiac motion. We aim to develop a self-gated, cine MRI acquisition scheme with data-driven cluster-based binning of cardiac motion. METHODS: A Cartesian golden-step balanced steady-state free precession sequence with sorted k-space ordering was designed. Image data were acquired with breath-holding. Principal component analysis and k-means clustering were used for binning of cardiac phases. Cluster compactness in the time dimension was assessed using temporal variability, and dispersion in the spatial dimension was assessed using the Calinski-Harabasz index. The proposed and the reference electrocardiogram (ECG)-gated cine methods were compared using a four-point image quality score, SNR and CNR values, and Bland-Altman analyses of ventricular function. RESULTS: A total of 10 subjects with sinus rhythm and 8 subjects with arrhythmias underwent cardiac MRI at 3.0 T. The temporal variability was 45.6 ms (cluster) versus 24.6 ms (ECG-based) (p < 0.001), and the Calinski-Harabasz index was 59.1 ± 9.1 (cluster) versus 22.0 ± 7.1 (ECG based) (p < 0.001). In subjects with sinus rhythm, 100% of the end-systolic and end-diastolic images from both the cluster and reference approach received the highest image quality score of 4. Relative to the reference cine images, the cluster-based multiphase (cine) image quality consistently received a one-point lower score (p < 0.05), whereas the SNR and CNR values were not significantly different (p = 0.20). In cases with arrhythmias, 97.9% of the end-systolic and end-diastolic images from the cluster approach received an image quality score of 3 or more. The mean bias values for biventricular ejection fraction and volumes derived from the cluster approach versus reference cine were negligible. CONCLUSION: ECG-free cine cardiac MRI with data-driven clustering for binning of cardiac motion is feasible and enables quantification of cardiac function.


Subject(s)
Image Interpretation, Computer-Assisted , Magnetic Resonance Imaging, Cine , Humans , Magnetic Resonance Imaging, Cine/methods , Image Interpretation, Computer-Assisted/methods , Cardiac-Gated Imaging Techniques/methods , Ventricular Function , Cluster Analysis , Reproducibility of Results
11.
Magn Reson Med ; 91(5): 1936-1950, 2024 May.
Article in English | MEDLINE | ID: mdl-38174593

ABSTRACT

PURPOSE: Widely used conventional 2D T2 * approaches that are based on breath-held, electrocardiogram (ECG)-gated, multi-gradient-echo sequences are prone to motion artifacts in the presence of incomplete breath holding or arrhythmias, which is common in cardiac patients. To address these limitations, a 3D, non-ECG-gated, free-breathing T2 * technique that enables rapid whole-heart coverage was developed and validated. METHODS: A continuous random Gaussian 3D k-space sampling was implemented using a low-rank tensor framework for motion-resolved 3D T2 * imaging. This approach was tested in healthy human volunteers and in swine before and after intravenous administration of ferumoxytol. RESULTS: Spatial-resolution matched T2 * images were acquired with 2-3-fold reduction in scan time using the proposed T2 * mapping approach relative to conventional T2 * mapping. Compared with the conventional approach, T2 * images acquired with the proposed method demonstrated reduced off-resonance and flow artifacts, leading to higher image quality and lower coefficient of variation in T2 *-weighted images of the myocardium of swine and humans. Mean myocardial T2 * values determined using the proposed and conventional approaches were highly correlated and showed minimal bias. CONCLUSION: The proposed non-ECG-gated, free-breathing, 3D T2 * imaging approach can be performed within 5 min or less. It can overcome critical image artifacts from undesirable cardiac and respiratory motion and bulk off-resonance shifts at the heart-lung interface. The proposed approach is expected to facilitate faster and improved cardiac T2 * mapping in those with limited breath-holding capacity or arrhythmias.


Subject(s)
Heart , Myocardium , Humans , Animals , Swine , Heart/diagnostic imaging , Respiration , Breath Holding , Magnetic Resonance Imaging, Cine/methods , Magnetic Resonance Imaging , Imaging, Three-Dimensional/methods
12.
J Cardiovasc Magn Reson ; 26(1): 100999, 2024.
Article in English | MEDLINE | ID: mdl-38237903

ABSTRACT

BACKGROUND: High-intensity plaque (HIP) on magnetic resonance imaging (MRI) has been documented as a powerful predictor of periprocedural myocardial injury (PMI) following percutaneous coronary intervention (PCI). Despite the recent proposal of three-dimensional HIP quantification to enhance the predictive capability, the conventional pulse sequence, which necessitates the separate acquisition of anatomical reference images, hinders accurate three-dimensional segmentation along the coronary vasculature. Coronary atherosclerosis T1-weighted characterization (CATCH) enables the simultaneous acquisition of inherently coregistered dark-blood plaque and bright-blood coronary artery images. We aimed to develop a novel HIP quantification approach using CATCH and to ascertain its superior predictive performance compared to the conventional two-dimensional assessment based on plaque-to-myocardium signal intensity ratio (PMR). METHODS: In this prospective study, CATCH MRI was conducted before elective stent implantation in 137 lesions from 125 patients. On CATCH images, dedicated software automatically generated tubular three-dimensional volumes of interest on the dark-blood plaque images along the coronary vasculature, based on the precisely matched bright-blood coronary artery images, and subsequently computed PMR and HIP volume (HIPvol). Specifically, HIPvol was calculated as the volume of voxels with signal intensity exceeding that of the myocardium, weighted by their respective signal intensities. PMI was defined as post-PCI cardiac troponin-T > 5 × the upper reference limit. RESULTS: The entire analysis process was completed within 3 min per lesion. PMI occurred in 44 lesions. Based on the receiver operating characteristic curve analysis, HIPvol outperformed PMR for predicting PMI (C-statistics, 0.870 [95% CI, 0.805-0.936] vs. 0.787 [95% CI, 0.706-0.868]; p = 0.001). This result was primarily driven by the higher sensitivity HIPvol offered: 0.886 (95% CI, 0.754-0.962) vs. 0.750 for PMR (95% CI, 0.597-0.868; p = 0.034). Multivariable analysis identified HIPvol as an independent predictor of PMI (odds ratio, 1.15 per 10-µL increase; 95% CI, 1.01-1.30, p = 0.035). CONCLUSIONS: Our semi-automated method of analyzing coronary plaque using CATCH MRI provided rapid HIP quantification. Three-dimensional assessment using this approach had a better ability to predict PMI than conventional two-dimensional assessment.


Subject(s)
Coronary Artery Disease , Coronary Vessels , Image Interpretation, Computer-Assisted , Imaging, Three-Dimensional , Percutaneous Coronary Intervention , Plaque, Atherosclerotic , Predictive Value of Tests , Humans , Male , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/pathology , Prospective Studies , Female , Middle Aged , Aged , Percutaneous Coronary Intervention/adverse effects , Coronary Vessels/diagnostic imaging , Coronary Vessels/pathology , Risk Factors , Treatment Outcome , Stents , Area Under Curve , ROC Curve , Magnetic Resonance Imaging , Reproducibility of Results
13.
J Cardiovasc Magn Reson ; 26(1): 100997, 2024.
Article in English | MEDLINE | ID: mdl-38237900

ABSTRACT

Cardiovascular magnetic resonance (CMR) protocols can be lengthy and complex, which has driven the research community to develop new technologies to make these protocols more efficient and patient-friendly. Two different approaches to improving CMR have been proposed, specifically "all-in-one" CMR, where several contrasts and/or motion states are acquired simultaneously, and "real-time" CMR, in which the examination is accelerated to avoid the need for breathholding and/or cardiac gating. The goal of this two-part manuscript is to describe these two different types of emerging rapid CMR. To this end, the vision of each is described, along with techniques which have been devised and tested along the pathway of clinical implementation. The pros and cons of the different methods are presented, and the remaining open needs of each are detailed. Part 1 will tackle the "all-in-one" approaches, and Part 2 the "real-time" approaches along with an overall summary of these emerging methods.


Subject(s)
Cardiovascular Diseases , Magnetic Resonance Imaging , Predictive Value of Tests , Humans , Cardiovascular Diseases/diagnostic imaging , Cardiovascular Diseases/physiopathology , Forecasting , Image Interpretation, Computer-Assisted , Diffusion of Innovation , Time Factors , Reproducibility of Results , Prognosis
14.
Front Radiol ; 3: 1223377, 2023.
Article in English | MEDLINE | ID: mdl-37886239

ABSTRACT

Purpose: To develop a deep learning-based method to retrospectively quantify T2 from conventional T1- and T2-weighted images. Methods: Twenty-five subjects were imaged using a multi-echo spin-echo sequence to estimate reference prostate T2 maps. Conventional T1- and T2-weighted images were acquired as the input images. A U-Net based neural network was developed to directly estimate T2 maps from the weighted images using a four-fold cross-validation training strategy. The structural similarity index (SSIM), peak signal-to-noise ratio (PSNR), mean percentage error (MPE), and Pearson correlation coefficient were calculated to evaluate the quality of network-estimated T2 maps. To explore the potential of this approach in clinical practice, a retrospective T2 quantification was performed on a high-risk prostate cancer cohort (Group 1) and a low-risk active surveillance cohort (Group 2). Tumor and non-tumor T2 values were evaluated by an experienced radiologist based on region of interest (ROI) analysis. Results: The T2 maps generated by the trained network were consistent with the corresponding reference. Prostate tissue structures and contrast were well preserved, with a PSNR of 26.41 ± 1.17 dB, an SSIM of 0.85 ± 0.02, and a Pearson correlation coefficient of 0.86. Quantitative ROI analyses performed on 38 prostate cancer patients revealed estimated T2 values of 80.4 ± 14.4 ms and 106.8 ± 16.3 ms for tumor and non-tumor regions, respectively. ROI measurements showed a significant difference between tumor and non-tumor regions of the estimated T2 maps (P < 0.001). In the two-timepoints active surveillance cohort, patients defined as progressors exhibited lower estimated T2 values of the tumor ROIs at the second time point compared to the first time point. Additionally, the T2 difference between two time points for progressors was significantly greater than that for non-progressors (P = 0.010). Conclusion: A deep learning method was developed to estimate prostate T2 maps retrospectively from clinically acquired T1- and T2-weighted images, which has the potential to improve prostate cancer diagnosis and characterization without requiring extra scans.

15.
Front Cardiovasc Med ; 10: 1160183, 2023.
Article in English | MEDLINE | ID: mdl-37790594

ABSTRACT

T1 mapping is becoming a staple magnetic resonance imaging method for diagnosing myocardial diseases such as ischemic cardiomyopathy, hypertrophic cardiomyopathy, myocarditis, and more. Clinically, most T1 mapping sequences acquire a single slice at a single cardiac phase across a 10 to 15-heartbeat breath-hold, with one to three slices acquired in total. This leaves opportunities for improving patient comfort and information density by acquiring data across multiple cardiac phases in free-running acquisitions and across multiple respiratory phases in free-breathing acquisitions. Scanning in the presence of cardiac and respiratory motion requires more complex motion characterization and compensation. Most clinical mapping sequences use 2D single-slice acquisitions; however newer techniques allow for motion-compensated reconstructions in three dimensions and beyond. To further address confounding factors and improve measurement accuracy, T1 maps can be acquired jointly with other quantitative parameters such as T2, T2∗, fat fraction, and more. These multiparametric acquisitions allow for constrained reconstruction approaches that isolate contributions to T1 from other motion and relaxation mechanisms. In this review, we examine the state of the literature in motion-corrected and motion-resolved T1 mapping, with potential future directions for further technical development and clinical translation.

16.
Front Radiol ; 3: 1168901, 2023.
Article in English | MEDLINE | ID: mdl-37731600

ABSTRACT

Introduction: Dynamic contrast-enhanced (DCE) MRI has important clinical value for early detection, accurate staging, and therapeutic monitoring of cancers. However, conventional multi-phasic abdominal DCE-MRI has limited temporal resolution and provides qualitative or semi-quantitative assessments of tissue vascularity. In this study, the feasibility of retrospectively quantifying multi-phasic abdominal DCE-MRI by using pharmacokinetics-informed deep learning to improve temporal resolution was investigated. Method: Forty-five subjects consisting of healthy controls, pancreatic ductal adenocarcinoma (PDAC), and chronic pancreatitis (CP) were imaged with a 2-s temporal-resolution quantitative DCE sequence, from which 30-s temporal-resolution multi-phasic DCE-MRI was synthesized based on clinical protocol. A pharmacokinetics-informed neural network was trained to improve the temporal resolution of the multi-phasic DCE before the quantification of pharmacokinetic parameters. Through ten-fold cross-validation, the agreement between pharmacokinetic parameters estimated from synthesized multi-phasic DCE after deep learning inference was assessed against reference parameters from the corresponding quantitative DCE-MRI images. The ability of the deep learning estimated parameters to differentiate abnormal from normal tissues was assessed as well. Results: The pharmacokinetic parameters estimated after deep learning have a high level of agreement with the reference values. In the cross-validation, all three pharmacokinetic parameters (transfer constant Ktrans, fractional extravascular extracellular volume ve, and rate constant kep) achieved intraclass correlation coefficient and R2 between 0.84-0.94, and low coefficients of variation (10.1%, 12.3%, and 5.6%, respectively) relative to the reference values. Significant differences were found between healthy pancreas, PDAC tumor and non-tumor, and CP pancreas. Discussion: Retrospective quantification (RoQ) of clinical multi-phasic DCE-MRI is possible by deep learning. This technique has the potential to derive quantitative pharmacokinetic parameters from clinical multi-phasic DCE data for a more objective and precise assessment of cancer.

17.
Magn Reson Med ; 90(6): 2362-2374, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37578085

ABSTRACT

PURPOSE: Deep learning superresolution (SR) is a promising approach to reduce MRI scan time without requiring custom sequences or iterative reconstruction. Previous deep learning SR approaches have generated low-resolution training images by simple k-space truncation, but this does not properly model in-plane turbo spin echo (TSE) MRI resolution degradation, which has variable T2 relaxation effects in different k-space regions. To fill this gap, we developed a T2 -deblurred deep learning SR method for the SR of 3D-TSE images. METHODS: A SR generative adversarial network was trained using physically realistic resolution degradation (asymmetric T2 weighting of raw high-resolution k-space data). For comparison, we trained the same network structure on previous degradation models without TSE physics modeling. We tested all models for both retrospective and prospective SR with 3 × 3 acceleration factor (in the two phase-encoding directions) of genetically engineered mouse embryo model TSE-MR images. RESULTS: The proposed method can produce high-quality 3 × 3 SR images for a typical 500-slice volume with 6-7 mouse embryos. Because 3 × 3 SR was performed, the image acquisition time can be reduced from 15 h to 1.7 h. Compared to previous SR methods without TSE modeling, the proposed method achieved the best quantitative imaging metrics for both retrospective and prospective evaluations and achieved the best imaging-quality expert scores for prospective evaluation. CONCLUSION: The proposed T2 -deblurring method improved accuracy and image quality of deep learning-based SR of TSE MRI. This method has the potential to accelerate TSE image acquisition by a factor of up to 9.


Subject(s)
Deep Learning , Animals , Mice , Retrospective Studies , Magnetic Resonance Imaging/methods , Imaging, Three-Dimensional/methods
19.
Magn Reson Med ; 90(4): 1672-1681, 2023 10.
Article in English | MEDLINE | ID: mdl-37246485

ABSTRACT

PURPOSE: To develop a deep learning method to synthesize conventional contrast-weighted images in the brain from MR multitasking spatial factors. METHODS: Eighteen subjects were imaged using a whole-brain quantitative T1 -T2 -T1ρ MR multitasking sequence. Conventional contrast-weighted images consisting of T1 MPRAGE, T1 gradient echo, and T2 fluid-attenuated inversion recovery were acquired as target images. A 2D U-Net-based neural network was trained to synthesize conventional weighted images from MR multitasking spatial factors. Quantitative assessment and image quality rating by two radiologists were performed to evaluate the quality of deep-learning-based synthesis, in comparison with Bloch-equation-based synthesis from MR multitasking quantitative maps. RESULTS: The deep-learning synthetic images showed comparable contrasts of brain tissues with the reference images from true acquisitions and were substantially better than the Bloch-equation-based synthesis results. Averaging on the three contrasts, the deep learning synthesis achieved normalized root mean square error = 0.184 ± 0.075, peak SNR = 28.14 ± 2.51, and structural-similarity index = 0.918 ± 0.034, which were significantly better than Bloch-equation-based synthesis (p < 0.05). Radiologists' rating results show that compared with true acquisitions, deep learning synthesis had no notable quality degradation and was better than Bloch-equation-based synthesis. CONCLUSION: A deep learning technique was developed to synthesize conventional weighted images from MR multitasking spatial factors in the brain, enabling the simultaneous acquisition of multiparametric quantitative maps and clinical contrast-weighted images in a single scan.


Subject(s)
Deep Learning , Humans , Brain/diagnostic imaging , Magnetic Resonance Imaging/methods , Neural Networks, Computer , Image Processing, Computer-Assisted/methods
SELECTION OF CITATIONS
SEARCH DETAIL