Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters











Language
Publication year range
1.
Urology ; 184: 266-271, 2024 Feb.
Article in English | MEDLINE | ID: mdl-37972898

ABSTRACT

OBJECTIVE: To determine the role of androgens in penile and urethral health, we sought to understand what impact hypogonadism may have on artificial urinary sphincter (AUS) and inflatable penile prosthesis (IPP) outcomes. We hypothesize that patients with hypogonadism are at increased risk of reinterventions, complications, and infections. METHODS: We queried the TriNetX Global Database in March 2023 for patients receiving an AUS or IPP, looking at lifetime reintervention, complication, and infection rates. We conducted multiple comparisons: (1) eugonadal patients against hypogonadal patients, (2) hypogonadal patients on testosterone replacement therapy (TRT) against hypogonadal patients not on TRT, and (3) hypogonadal patients on TRT against eugonadal patients. RESULTS: Hypogonadal patients undergoing AUS had more complications (33.5% vs 28.3%), higher reintervention rates (27.7% vs 24.3%) and higher infection rates (7.3% vs 6.8%), albeit none reaching significance. Hypogonadal patients undergoing IPP had significantly higher infection rates (6.3% vs 4.4%, RR 1.5 (1.04, 2.04)) and reintervention rates (14.9% vs 11.9%, RR 1.3 (1.04, 1.61)), but not complication rates (21.9% vs 18.9%). When comparing patients with hypogonadism on TRT vs off TRT, there was not a significant difference in reinterventions, or complications, in AUS and IPP patients, but there were significantly more infections in IPP patients (7.0% vs 3.9%, RR 1.9 (1.002, 3.5)). CONCLUSION: Hypogonadal patients have more reinterventions, complications, and infections following urologic implant surgery, to varying levels of significance. TRT may not be completely protective to improve tissue health but with many limitations that should be explored in further research.


Subject(s)
Penile Implantation , Penile Prosthesis , Urinary Sphincter, Artificial , Humans , Male , Urinary Sphincter, Artificial/adverse effects , Androgens/therapeutic use , Penile Prosthesis/adverse effects , Urethra
2.
Urology ; 174: 191-195, 2023 04.
Article in English | MEDLINE | ID: mdl-36754235

ABSTRACT

OBJECTIVE: To understand whether patients taking sodium-glucose co-transporter 2 inhibitors (SGLT2i) would be at a similar risk of genitourinary device infection or failure as patients not taking these medications. METHODS: We queried the TriNetX database for all adult male patients undergoing artificial urinary sphincter (AUS) or inflatable penile prosthesis (IPP) and compared patients taking SGLT2i against those not. Cohorts and outcomes were defined using current procedural terminology and International Classification of Diseases (ICD-10) codes. We used Age, body mass index, diabetes, smoking history and history of prostatectomy to generate propensity score matching. Our primary outcome was need for reintervention after implantation based on current procedural terminology codes. Secondary outcomes included infection rate and overall complication rate based on ICD-10 codes. Analytics were performed via TriNetX which calculated risk ratios. RESULTS: Analyses were run on November 28, 2022. After propensity score matching, there were 319 and 83 patients in each IPP and AUS cohort and comorbidity profiles were similar. Patients with an IPP on an SGLT2i were at a lower risk of overall complication (10.6% vs 16.1%, RR 0.66, P = .049). There was similar rates for AUS and risk of complication and for either implant on risk of infection or reintervention. CONCLUSION: Patients taking SGLT2is may be safely offered urologic implants. Patients taking an SGLT2 had a lower risk of complication for IPP, and there were similar rates of infection and reintervention for both IPP and AUS.


Subject(s)
Penile Implantation , Penile Prosthesis , Symporters , Urinary Sphincter, Artificial , Adult , Humans , Male , Glucose , Retrospective Studies , Sodium , Urinary Sphincter, Artificial/adverse effects , Sodium-Glucose Transporter 2 Inhibitors/therapeutic use
5.
Urology ; 146: 6-14, 2020 12.
Article in English | MEDLINE | ID: mdl-32991908

ABSTRACT

The implantation of penile protheses for the surgical treatment of erectile dysfunction has risen in popularity over the past several decades. Considerable advances have been made in surgical protocol and device design, specifically targeting infection prevention. Despite these efforts, device infection remains a critical problem, which causes significant physical and emotional burden to the patient. The aim of this review is to broaden the discussion of best practices by not only examining practices in urology, but additionally delving into the field of orthopedic surgery to identify techniques and approaches that may be applied to penile prothesis surgery.


Subject(s)
Erectile Dysfunction/surgery , Orthopedic Procedures/methods , Penile Implantation/adverse effects , Penile Prosthesis/adverse effects , Penis/surgery , Prosthesis-Related Infections/prevention & control , Surgical Wound Infection/prevention & control , Urology/methods , Anti-Bacterial Agents/therapeutic use , Anti-Infective Agents/administration & dosage , Antibiotic Prophylaxis , Biofilms , Cost-Benefit Analysis , Humans , Male , Operating Rooms , Staphylococcus aureus
6.
Int. braz. j. urol ; 43(5): 911-916, Sept.-Oct. 2017. tab, graf
Article in English | LILACS | ID: biblio-892884

ABSTRACT

ABSTRACT Objective: Many patients who undergo inflatable penile prosthesis (IPP) replacement are often upsized to larger cylinders, suggesting the IPP may serve as a tissue expander and increase internal penile length. The objective of this study is to evaluate whether cylinder length increases with subsequent IPP insertion. Materials and Methods: We queried American Medical Systems and Coloplast Patient Information Form databases to identify patients who underwent IPP placement and replacement between 2004-2013. Patients were grouped by device type and time to replacement (<2 or ≥2 years). We selected the 2-year mark for subgroup analysis to allow time for tissue expansion to occur and to exclude patients who underwent early explantation (e.g. erosion or infection). Results: Two thousand, seven hundred and forty nine patients (1,532 AMS 700 LGX, 717 AMS 700 CX, and 500 Coloplast Titan) met the inclusion criteria. Mean time between implants was earlier for LGX (29 months) than CX (39 months) and Titan (48 months) patients (p<0.001). Patients who underwent device replacement at <2 years did not experience an increase in mean cylinder length. On the contrary, patients who underwent device replacement at ≥2 years did experience significant increases in mean cylinder length (LGX 1.2 cm, CX 1.1 cm, and Titan 0.9 cm, p<0.001). The mean increases in length at ≥2 years were similar between the 3 devices (p=0.20). Sixty percent of patients demonstrated increases of >0.5 cm and 40% demonstrated increases of ≥1 cm. Conclusions: As demonstrated, the IPP may provide tissue expansion over time. Further evaluation is needed to determine if increased cylinder length correlates to increased functional length and patient satisfaction.


Subject(s)
Humans , Male , Penis/surgery , Penile Prosthesis , Tissue Expansion Devices , Patient Satisfaction , Penis/anatomy & histology , Time Factors , Middle Aged
7.
Int Braz J Urol ; 43(5): 911-916, 2017.
Article in English | MEDLINE | ID: mdl-28537700

ABSTRACT

OBJECTIVE: Many patients who undergo inflatable penile prosthesis (IPP) replacement are often upsized to larger cylinders, suggesting the IPP may serve as a tissue expander and increase internal penile length. The objective of this study is to evaluate whether cylinder length increases with subsequent IPP insertion. MATERIALS AND METHODS: We queried American Medical Systems and Coloplast Patient Information Form databases to identify patients who underwent IPP placement and replacement between 2004-2013. Patients were grouped by device type and time to replacement (<2 or ≥2 years). We selected the 2-year mark for subgroup analysis to allow time for tissue expansion to occur and to exclude patients who underwent early explantation (e.g. erosion or infection). RESULTS: Two thousand, seven hundred and forty nine patients (1,532 AMS 700 LGX, 717 AMS 700 CX, and 500 Coloplast Titan) met the inclusion criteria. Mean time between implants was earlier for LGX (29 months) than CX (39 months) and Titan (48 months) patients (p<0.001). Patients who underwent device replacement at <2 years did not experience an increase in mean cylinder length. On the contrary, patients who underwent device replacement at ≥2 years did experience significant increases in mean cylinder length (LGX 1.2 cm, CX 1.1 cm, and Titan 0.9 cm, p<0.001). The mean increases in length at ≥2 years were similar between the 3 devices (p=0.20). Sixty percent of patients demonstrated increases of >0.5 cm and 40% demonstrated increases of ≥1 cm. CONCLUSIONS: As demonstrated, the IPP may provide tissue expansion over time. Further evaluation is needed to determine if increased cylinder length correlates to increased functional length and patient satisfaction.


Subject(s)
Patient Satisfaction , Penile Prosthesis , Penis/surgery , Tissue Expansion Devices , Humans , Male , Middle Aged , Penis/anatomy & histology , Time Factors
SELECTION OF CITATIONS
SEARCH DETAIL