1.
Blood Coagul Fibrinolysis ; 29(2): 196-204, 2018 Mar.
Article in English | MEDLINE | ID: mdl-29369078

ABSTRACT

: Hemostasis disorders are one of the major clinical conditions of snakebites and are because of mechanisms which may disrupt vessels, platelets, clotting factors and fibrinolysis. Thromboelastography (TEG) could help to understand these effects in the clinical practice. A retrospective study reports a series of patients presenting a snakebite-related coagulopathy, treated with antivenom and monitored with conventional tests and TEG in a French military treatment facility (Republic of Djibouti, East Africa) between August 2011 and September 2013. Conventional coagulation assays (platelets, prothrombin time, activated partial thromboplastin time, fibrinogen) and TEG measurements were taken on arrival and at various times during the first 72 h of hospitalization, at the discretion of the physician. The study included 14 patients (median age 28 years). Bleedings were present in five patients. All patients received antivenom. A coagulopathy was present in all patients and was detected by both conventional assays and TEG. None exhibited thrombocytopenia. Prothrombin time and fibrinogen remained abnormal for most of patients during the first 72 h. The TEG profiles of 11 patients (79%) showed incoagulability at admission (R-time > 60 min). TEG distinguished 10 patients with a generalized clotting factor deficiency and 4 patients with an isolated fibrinogen deficiency after an initial profile of incoagulability. Hyperfibrinolysis was evident for 12 patients (86%) after Hour 6. Snake envenomations in Djibouti involve a consumption coagulopathy in conjunction with delayed hyperfibrinolysis. TEG could improve medical management of the condition and assessment of additional therapeutics associated with the antivenom.


Subject(s)
Snake Bites/blood , Thrombelastography/methods , Adult , Animals , Djibouti , Female , Humans , Male , Retrospective Studies , Snake Bites/complications
2.
Simul Healthc ; 9(2): 81-4, 2014 Apr.
Article in English | MEDLINE | ID: mdl-24695079

ABSTRACT

INTRODUCTION: The use of a stethoscope is essential to the delivery of continuous, supportive en route care during aeromedical evacuations. We compared the capability of 2 stethoscopes (electronic, Litmann 3000; conventional, Litmann Cardiology III) at detecting pathologic heart and lung sounds, aboard a C135, a medical transport aircraft. METHODS: Sounds were mimicked using a mannequin-based simulator SimMan. Five practitioners examined the mannequin during a fly, with a variety of abnormalities as follows: crackles, wheezing, right and left lung silence, as well as systolic, diastolic, and Austin-Flint murmur. The comparison for diagnosis assessed (correct or wrong) between using the electronic and conventional stethoscopes were performed as a McNemar test. RESULTS: A total of 70 evaluations were performed. For cardiac sounds, diagnosis was right in 0/15 and 4/15 auscultations, respectively, with conventional and electronic stethoscopes (McNemar test, P = 0.13). For lung sounds, right diagnosis was found with conventional stethoscope in 10/20 auscultations versus 18/20 with electronic stethoscope (P = 0.013). CONCLUSIONS: Flight practitioners involved in aeromedical evacuation on C135 plane are more able to practice lung auscultation on a mannequin with this amplified stethoscope than with the traditional one. No benefit was found for heart sounds.


Subject(s)
Air Ambulances , Auscultation/instrumentation , Heart/physiology , Lung/physiology , Stethoscopes , Adult , Computer Simulation , Female , Humans , Male , Manikins , Middle Aged , Noise, Transportation , Vibration