1.
Neuromodulation ; 2024 Feb 15.
Article in English | MEDLINE | ID: mdl-38363246

ABSTRACT

BACKGROUND: Stimulation of diuresis is an essential component of heart failure treatment to reduce fluid overload. Over time, increasing doses of loop diuretics are required to achieve adequate urine output, and approximately 30% to 45% of patients develop diuretic resistance. We investigated the feasibility of affecting renal afferent sensory nerves by dorsal root ganglion neurostimulation as an alternative to medication to increase diuresis. MATERIALS AND METHODS: Acute volume overload with an elevated and stable pulmonary capillary wedge pressure (PCWP) was induced by infusion of isotonic fluid in swine (N = 7). In each experiment, diuresis and blood electrolyte levels were measured during cycles of up to two hours (baseline, stimulation, poststimulation) through bladder catheterization. Efficacy was tested using bilateral dorsal root ganglion (bDRG) stimulation at the T11 and/or T12 vertebral levels. RESULTS: An elevated, stable PCWP (15 ± 4 mm Hg, N = 7) was obtained after uploading. Under these conditions, average diuresis increased 20% to 205% compared with no stimulation. Side effects such as motor stimulation were mitigated by decreasing current or terminated spontaneously without intervention. There was no negative effect on acute kidney function because blood electrolyte concentrations remained stable. When stimulation was deactivated, urine output decreased significantly but did not return to baseline levels, suggesting a carry-over effect of up to two hours. CONCLUSIONS: Electrical stimulation (bDRG) at T11 and/or T12 increased diuresis in an acute volume overload model. Side effects caused by unintended (motor) stimulation could be eliminated by reducing the electrical current while sustaining increased diuresis.

2.
Heart Rhythm ; 20(9): 1316-1324, 2023 09.
Article in English | MEDLINE | ID: mdl-37247684

ABSTRACT

BACKGROUND: Continuous optimization of atrioventricular (AV) delay for cardiac resynchronization therapy (CRT) is mainly performed by electrical means. OBJECTIVE: The purpose of this study was to develop an estimation model of cardiac function that uses a piezoelectric microphone embedded in a pulse generator to guide CRT optimization. METHODS: Electrocardiogram, left ventricular pressure (LVP), and heart sounds were simultaneously collected during CRT device implantation procedures. A piezoelectric alarm transducer embedded in a modified CRT device facilitated recording of heart sounds in patients undergoing a pacing protocol with different AV delays. Machine learning (ML) was used to produce a decision-tree ensemble model capable of estimating absolute maximal LVP (LVPmax) and maximal rise of LVP (LVdP/dtmax) using 3 heart sound-based features. To gauge the applicability of ML in AV delay optimization, polynomial curves were fitted to measured and estimated values. RESULTS: In the data set of ∼30,000 heartbeats, ML indicated S1 amplitude, S2 amplitude, and S1 integral (S1 energy for LVdP/dtmax) as most prominent features for AV delay optimization. ML resulted in single-beat estimation precision for absolute values of LVPmax and LVdP/dtmax of 67% and 64%, respectively. For 20-30 beat averages, cross-correlation between measured and estimated LVPmax and LVdP/dtmax was 0.999 for both. The estimated optimal AV delays were not significantly different from those measured using invasive LVP (difference -5.6 ± 17.1 ms for LVPmax and +5.1 ± 6.7 ms for LVdP/dtmax). The difference in function at estimated and measured optimal AV delays was not statiscally significant (1 ± 3 mm Hg for LVPmax and 9 ± 57 mm Hg/s for LVdP/dtmax). CONCLUSION: Heart sound sensors embedded in a CRT device, powered by a ML algorithm, provide a reliable assessment of optimal AV delays and absolute LVPmax and LVdP/dtmax.


Subject(s)
Cardiac Resynchronization Therapy , Heart Failure , Heart Sounds , Humans , Cardiac Resynchronization Therapy/methods , Electrocardiography/methods , Cardiac Resynchronization Therapy Devices , Ultrasonography , Heart Failure/diagnosis , Heart Failure/therapy
3.
Heart Rhythm ; 20(4): 572-579, 2023 04.
Article in English | MEDLINE | ID: mdl-36574867

ABSTRACT

BACKGROUND: Phonocardiography (PCG) can be used to determine systolic time intervals (STIs) from ventricular pacing spike to the first heart sound (VS1) and from the first to the second heart sound (S1S2). OBJECTIVE: The purpose of this study was to investigate the relations between STIs and hemodynamics during atrioventricular (AV) delay optimization of biventricular pacing (BiVP) in animals and patients. METHODS: Five pigs with AV block underwent BiVP, while PCG was collected from an epicardial accelerometer. In 21 patients undergoing cardiac resynchronization therapy device implantation, PCG was recorded with a pulse generator-embedded microphone. Optimal AV delays derived from shortest VS1 and longest S1S2 were compared with AV delays derived from highest left ventricular pressure (LVP), maximal rate of rise in LVP, and stroke work. RESULTS: In pigs, VS1 and S1S2 predicted the AV delays with optimal hemodynamics (highest LVP, maximal rate of rise in LVP, and stroke work) by a median error of 2-28 ms, resulting in a median loss of <2% of pump function. In patients, VS1 and S1S2 predicted the optimal AV delay by errors of 32.5 and 37.5 ms, respectively, resulting in 0.2%-0.9% lower LVP and stroke work, which were reduced to 21 and 24 ms in 8 patients with a full-capture AV delay of >180 ms. CONCLUSION: During BiVP with varying AV delays, close relations exist between PCG-derived STIs and hemodynamic parameters. AV delays advised by PCG-derived STIs cause only a minimal loss of pump function compared with those based on invasive hemodynamic measurements. TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT01832493.


Subject(s)
Cardiac Resynchronization Therapy , Heart Failure , Heart Sounds , Sexually Transmitted Diseases , Animals , Swine , Cardiac Resynchronization Therapy/methods , Systole , Heart Failure/diagnosis , Heart Failure/therapy , Hemodynamics , Sexually Transmitted Diseases/therapy , Treatment Outcome , Cardiac Pacing, Artificial
4.
Front Cardiovasc Med ; 9: 979581, 2022.
Article in English | MEDLINE | ID: mdl-36186985

ABSTRACT

Background: Cardiac resynchronization therapy (CRT) is helpful in selected patients; however, responder rates rarely exceed 70%. Optimization of CRT may therefore benefit a large number of patients. Time-to-peak dP/dt (Td) is a novel marker of myocardial synergy that reflects the degree of myocardial dyssynchrony with the potential to guide and optimize treatment with CRT. Optimal electrical activation is a prerequisite for CRT to be effective. Electrical activation can be altered by changing the electrical wave-front fusion resulting from pacing to optimize resynchronization. We designed this study to understand the acute effects of different electrical wave-front fusion strategies and LV pre-/postexcitation on Td and QRS duration (QRSd). A better understanding of measuring and optimizing resynchronization can help improve the benefits of CRT. Methods: Td and QRSd were measured in 19 patients undergoing a CRT implantation. Two biventricular pacing groups were compared: pacing the left ventricle (LV) with fusion with intrinsic right ventricular activation (FUSION group) and pacing the LV and right ventricle (RV) at short atrioventricular delay (STANDARD group) to avoid fusion with intrinsic RV activation. A quadripolar LV lead enabled pacing from widely separated electrodes; distal (DIST), proximal (PROX) and both electrodes combined (multipoint pacing, MPP). The LV was stimulated relative in time to RV activation (either RV pace-onset or QRS-onset), with the LV stimulated prior to (PRE), simultaneous with (SIM) or after (POST) RV activation. In addition, we analyzed the interactions of the two groups (FUSION/STANDARD) with three different electrode configurations (DIST, PROX, MPP), each paced with three different degrees of LV pre-/postexcitation (PRE, SIM, POST) in a statistical model. Results: We found that FUSION provided shorter Td and QRSd than STANDARD, MPP provided shorter Td and QRSd than DIST and PROX, and SIM provided both the shortest QRSd and Td compared to PRE and POST. The interaction analysis revealed that pacing MPP with fusion with intrinsic RV activation simultaneous with the onset of the QRS complex (MPP*FUSION*SIM) shortened QRSd and Td the most compared to all other modes and configurations. The difference in QRSd and Td from their respective references were significantly correlated (ß = 1, R = 0.9, p < 0.01). Conclusion: Pacing modes and electrode configurations designed to optimize electrical wave-front fusion (intrinsic RV activation, LV multipoint pacing and simultaneous RV and LV activation) shorten QRSd and Td the most. As demonstrated in this study, electrical and mechanical measures of resynchronization are highly correlated. Therefore, Td can potentially serve as a marker for CRT optimization.

5.
Front Physiol ; 13: 847164, 2022.
Article in English | MEDLINE | ID: mdl-36304577

ABSTRACT

The proto-diastolic third heart sound (S3) is observed in various hemodynamic conditions in both normal and diseased hearts. We propose a novel, one-degree of freedom mathematical model of mechanical vibrations of heart and blood that generates the third heart sound, implemented in a real-time model of the cardiovascular system (CircAdapt). To examine model functionality, S3 simulations were performed for conditions mimicking the normal heart as well as heart failure with preserved ejection fraction (HFpEF), atrioventricular valve regurgitation (AVR), atrioventricular valve stenosis (AVS) and septal shunts (SS). Simulated S3 showed both qualitative and quantitative agreements with measured S3 in terms of morphology, frequency, and timing. It was shown that ventricular mass, ventricular viscoelastic properties as well as inflow momentum play a key role in the generation of S3. The model indicated that irrespective of cardiac conditions, S3 vibrations are always generated, in both the left and right sides of the heart, albeit at different levels of audibility. S3 intensities increased in HFpEF, AVR and SS, but the changes of acoustic S3 features in AVS were not significant, as compared with the reference simulation. S3 loudness in all simulated conditions was proportional to the level of cardiac output and severity of cardiac conditions. In conclusion, our hemodynamics-driven mathematical model provides a fast and realistic simulation of S3 under various conditions which may be helpful to find new indicators for diagnosis and prognosis of cardiac diseases.

6.
Front Cardiovasc Med ; 9: 901267, 2022.
Article in English | MEDLINE | ID: mdl-35647062

ABSTRACT

The aim of the SYNSEQ (Left Ventricular Synchronous vs. Sequential MultiSpot Pacing for CRT) study was to evaluate the acute hemodynamic response (AHR) of simultaneous (3P-MPP syn) or sequential (3P-MPP seq) multi-3-point-left-ventricular (LV) pacing vs. single point pacing (SPP) in a group of patients at risk of a suboptimal response to cardiac resynchronization therapy (CRT). Twenty five patients with myocardial scar or QRS ≤ 150 or the absence of LBBB (age: 66 ± 12 years, QRS: 159 ± 12 ms, NYHA class II/III, LVEF ≤ 35%) underwent acute hemodynamic assessment by LV + dP/dtmax with a variety of LV pacing configurations at an optimized AV delay. The change in LV + dP/dt max (%ΔLV + dP/dt max) with 3P-MPP syn (15.6%, 95% CI: 8.8%-22.5%) was neither statistically significantly different to 3P-MPP seq (11.8%, 95% CI: 7.6-16.0%) nor to SPP basal (11.5%, 95% CI:7.1-15.9%) or SPP mid (12.2%, 95% CI:7.9-16.5%), but higher than SPP apical (10.6%, 95% CI:5.3-15.9%, p = 0.03). AHR (defined as a %ΔLV + dP/dt max ≥ 10%) varied between pacing configurations: 36% (9/25) for SPP apical, 44% (11/25) for SPP basal, 54% (13/24) for SPP mid, 56% (14/25) for 3P-MPP syn and 48% (11/23) for 3P-MPP seq.Fifteen patients (15/25, 60%) had an AHR in at least one pacing configuration. AHR was observed in 10/13 (77%) patients with a LBBB but only in 5/12 (42%) patients with a non-LBBB (p = 0.11). To conclude, simultaneous or sequential multipoint pacing compared to single point pacing did not improve the acute hemodynamic effect in a suboptimal CRT response population. Clinical Trial Registration: ClinicalTrials.gov, identifier: NCT02914457.

7.
Front Cardiovasc Med ; 9: 763048, 2022.
Article in English | MEDLINE | ID: mdl-35694657

ABSTRACT

Objective: A method to estimate absolute left ventricular (LV) pressure and its maximum rate of rise (LV dP/dtmax) from epicardial accelerometer data and machine learning is proposed. Methods: Five acute experiments were performed on pigs. Custom-made accelerometers were sutured epicardially onto the right ventricle, LV, and right atrium. Different pacing configurations and contractility modulations, using isoflurane and dobutamine infusions, were performed to create a wide variety of hemodynamic conditions. Automated beat-by-beat analysis was performed on the acceleration signals to evaluate amplitude, time, and energy-based features. For each sensing location, bootstrap aggregated classification tree ensembles were trained to estimate absolute maximum LV pressure (LVPmax) and LV dP/dtmax using amplitude, time, and energy-based features. After extraction of acceleration and pressure-based features, location specific, bootstrap aggregated classification ensembles were trained to estimate absolute values of LVPmax and its maximum rate of rise (LV dP/dtmax) from acceleration data. Results: With a dataset of over 6,000 beats, the algorithm narrowed the selection of 17 predefined features to the most suitable 3 for each sensor location. Validation tests showed the minimal estimation accuracies to be 93% and 86% for LVPmax at estimation intervals of 20 and 10 mmHg, respectively. Models estimating LV dP/dtmax achieved an accuracy of minimal 93 and 87% at estimation intervals of 100 and 200 mmHg/s, respectively. Accuracies were similar for all sensor locations used. Conclusion: Under pre-clinical conditions, the developed estimation method, employing epicardial accelerometers in conjunction with machine learning, can reliably estimate absolute LV pressure and its first derivative.

8.
ESC Heart Fail ; 8(6): 5222-5236, 2021 12.
Article in English | MEDLINE | ID: mdl-34514746

ABSTRACT

AIMS: We tested the hypothesis that shortening of time-to-peak left ventricular pressure rise (Td) reflect resynchronization in an animal model and that Td measured in patients will be helpful to identify long-term volumetric responders [end-systolic volume (ESV) decrease >15%] in cardiac resynchronization therapy (CRT). METHODS: Td was analysed in an animal study (n = 12) of left bundle-branch block (LBBB) with extensive instrumentation to detect left ventricular myocardial deformation, electrical activation, and pressures during pacing. The sum of electrical delays from the onset of pacing to four intracardiac electrodes formed a synchronicity index (SI). Pacing was performed at baseline, with LBBB, right and left ventricular pacing and finally with biventricular pacing (BIVP). We then studied Td at baseline and with BIVP in a clinical observational study in 45 patients during the implantation of CRT and followed up for up to 88 months. RESULTS: We found a strong relationship between Td and SI in the animals (R = 0.84, P < 0.01). Td and SI increased from narrow QRS at baseline (Td = 95 ± 2 ms, SI = 141 ± 8 ms) to LBBB (Td = 125 ± 2 ms, SI = 247 ± 9 ms, P < 0.01), and shortened with biventricular pacing (BIVP) (Td = 113 ± 2 ms and SI = 192 ± 7 ms, P < 0.01). Prolongation of Td was associated with more wasted deformation during the preejection period (R = 0.77, P < 0.01). Six patients increased ESV by 2.5 ± 18%, while 37 responders (85%) had a mean ESV decrease of 40 ± 15% after more than 6 months of follow-up. Responders presented with a higher Td at baseline than non-responders (163 ± 26 ms vs. 121 ± 19 ms, P < 0.01). Td decreased to 156 ± 16 ms (P = 0.02) with CRT in responders, while in non-responders, Td increased to 148 ± 21 ms (P < 0.01). A decrease in Td with BIVP to values similar or below what was found at baseline accurately identified responders to therapy (AUC 0.98, P < 0.01). Td at baseline and change in Td from baseline was linear related to the decrease in ESV at follow-up. All-cause mortality was high among six non-responders (n = 4), while no patients died in the responder group during follow-up. CONCLUSIONS: Prolongation of Td is associated with cardiac dyssynchrony and more wasted deformation during the preejection period. Shortening of a prolonged Td with CRT in patients accurately identifies volumetric responders to CRT with incremental value on top of current guidelines and practices. Thus, Td carries the potential to become a biomarker to predict long-term volumetric response in CRT candidates.


Subject(s)
Cardiac Resynchronization Therapy , Heart Failure , Animals , Arrhythmias, Cardiac/complications , Bundle-Branch Block/therapy , Humans , Ventricular Pressure
9.
PLoS Comput Biol ; 17(9): e1009361, 2021 09.
Article in English | MEDLINE | ID: mdl-34550969

ABSTRACT

NEW & NOTEWORTHY: To the best of our knowledge, this is the first hemodynamic-based heart sound generation model embedded in a complete real-time computational model of the cardiovascular system. Simulated heart sounds are similar to experimental and clinical measurements, both quantitatively and qualitatively. Our model can be used to investigate the relationships between heart sound acoustic features and hemodynamic factors/anatomical parameters.


Subject(s)
Heart Sounds/physiology , Hemodynamics/physiology , Models, Cardiovascular , Animals , Atrioventricular Block/physiopathology , Biomechanical Phenomena , Computational Biology , Computer Simulation , Computer Systems , Disease Models, Animal , Exercise/physiology , Heart Failure/physiopathology , Heart Valves/physiopathology , Humans , Mathematical Concepts , Phonocardiography/statistics & numerical data , Swine
10.
Open Heart ; 8(1)2021 05.
Article in English | MEDLINE | ID: mdl-33963078

ABSTRACT

BACKGROUND: We designed this study to assess the acute effects of different fusion strategies and left ventricular (LV) pre-excitation/post-excitation on LV dP/dtmax and QRS duration (QRSd). METHODS: We measured LV dP/dtmax and QRSd in 19 patients having cardiac resynchronisation therapy (CRT). Two groups of biventricular pacing were compared: pacing the left ventricle (LV) with FUSION with intrinsic right ventricle (RV) activation (FUSION), and pacing the LV and RV with NO FUSION with intrinsic RV activation. In the NO FUSION group, the RV was paced before the expected QRS onset. A quadripolar LV lead enabled distal, proximal and multipoint pacing (MPP). The LV was stimulated relative in time to either RV pace or QRS-onset in four pre-excitation/post-excitation classes (PCs). We analysed the interactions of two groups (FUSION/NO FUSION) with three different electrode configurations, each paced with four different degrees of LV pre-excitation (PC1-4) in a statistical model. RESULTS: LV dP/dtmax was higher with NO FUSION than with FUSION (769±46 mm Hg/s vs 746±46 mm Hg/s, p<0.01), while there was no difference in QRSd (NO FUSION 156±2 ms and FUSION 155±2 ms). LV dP/dtmax and QRSd increased with LV pre-excitation compared with pacing timed to QRS/RV pace-onset regardless of electrode configuration. Overall, pacing LV close to QRS-onset (FUSION) with MPP shortened QRSd the most, while LV dP/dtmax increased the most with LV pre-excitation. CONCLUSION: We show how a beneficial change in QRSd dissociates from the haemodynamic change in LV dP/dtmax with different biventricular pacing strategies. In this study, LV pre-excitation was the main determinant of LV dP/dtmax, while QRSd shortens with optimal resynchronisation.


Subject(s)
Cardiac Resynchronization Therapy Devices , Cardiac Resynchronization Therapy/methods , Heart Failure/therapy , Heart Ventricles/physiopathology , Hemodynamics/physiology , Practice Guidelines as Topic , Adolescent , Adult , Aged , Aged, 80 and over , Electrocardiography , Female , Heart Failure/physiopathology , Humans , Male , Middle Aged , Young Adult
11.
Physiol Rep ; 9(1): e14687, 2021 01.
Article in English | MEDLINE | ID: mdl-33400386

ABSTRACT

Second heart sound (S2) splitting results from nonsimultaneous closures between aortic (A2) and pulmonic valves (P2) and may be used to detect timing differences (dyssynchrony) in relaxation between right (RV) and left ventricle (LV). However, overlap of A2 and P2 and the change in heart sound morphologies have complicated detection of the S2 splitting interval. This study introduces a novel S-transform amplitude ridge tracking (START) algorithm for estimating S2 splitting interval and investigates the relationship between S2 splitting and interventricular relaxation dyssynchrony (IRD). First, the START algorithm was validated in a simulated model of heart sound. It showed small errors (<5 ms) in estimating splitting intervals from 10 to 70 ms, with A2/P2 amplitude ratios from 0.2 to 5, and signal-to-noise ratios from 10 to 30 dB. Subsequently, the START algorithm was evaluated in a porcine model employing a wide range of paced RV-LV delays. IRD was quantified by the time difference between invasively measured LV and RV pressure downslopes. Between LV pre-excitation to RV pre-excitation, mean S2 splitting interval decreased from 47 ms to 23 ms (p < .001), accompanied by a decrease in mean IRD from 8 ms to -18 ms (p < .001). S2 splitting interval was significantly correlated with IRD in each experiment (p < .001). In conclusion, the START algorithm can accurately assess S2 splitting and may serve as a useful tool to assess interventricular dyssynchrony.


Subject(s)
Echocardiography, Doppler/methods , Heart Failure/physiopathology , Heart Sounds , Ventricular Dysfunction/physiopathology , Algorithms , Animals , Heart Failure/diagnostic imaging , Male , Swine , Ventricular Dysfunction/diagnostic imaging
12.
Eur Heart J ; 41(48): 4556-4564, 2020 12 21.
Article in English | MEDLINE | ID: mdl-32128588

ABSTRACT

Providing therapies tailored to each patient is the vision of precision medicine, enabled by the increasing ability to capture extensive data about individual patients. In this position paper, we argue that the second enabling pillar towards this vision is the increasing power of computers and algorithms to learn, reason, and build the 'digital twin' of a patient. Computational models are boosting the capacity to draw diagnosis and prognosis, and future treatments will be tailored not only to current health status and data, but also to an accurate projection of the pathways to restore health by model predictions. The early steps of the digital twin in the area of cardiovascular medicine are reviewed in this article, together with a discussion of the challenges and opportunities ahead. We emphasize the synergies between mechanistic and statistical models in accelerating cardiovascular research and enabling the vision of precision medicine.


Subject(s)
Artificial Intelligence , Cardiology , Algorithms , Humans , Precision Medicine
13.
J Am Coll Cardiol ; 75(4): 347-359, 2020 02 04.
Article in English | MEDLINE | ID: mdl-32000945

ABSTRACT

BACKGROUND: Cardiac resynchronization therapy (CRT) is usually performed by biventricular (BiV) pacing. Previously, feasibility of transvenous implantation of a lead at the left ventricular (LV) endocardial side of the interventricular septum, referred to as LV septal (LVs) pacing, was demonstrated. OBJECTIVES: The authors sought to compare the acute electrophysiological and hemodynamic effects of LVs with BiV and His bundle (HB) pacing in CRT patients. METHODS: Temporary LVs pacing (transaortic approach) alone or in combination with right ventricular (RV) (LVs+RV), BiV, and HB pacing was performed in 27 patients undergoing CRT implantation. Electrophysiological changes were assessed using electrocardiography (QRS duration), vectorcardiography (QRS area), and multielectrode body surface mapping (standard deviation of activation times [SDAT]). Hemodynamic changes were assessed as the first derivative of LV pressure (LVdP/dtmax). RESULTS: As compared with baseline, LVs pacing resulted in a larger reduction in QRS area (to 73 ± 22 µVs) and SDAT (to 26 ± 7 ms) than BiV (to 93 ± 26 µVs and 31 ± 7 ms; both p < 0.05) and LVs+RV pacing (to 108 ± 37 µVs; p < 0.05; and 29 ± 8 ms; p = 0.05). The increase in LVdP/dtmax was similar during LVs and BiV pacing (17 ± 10% vs. 17 ± 9%, respectively) and larger than during LVs+RV pacing (11 ± 9%; p < 0.05). There were no significant differences between basal, mid-, or apical LVs levels in LVdP/dtmax and SDAT. In a subgroup of 16 patients, changes in QRS area, SDAT, and LVdP/dtmax were comparable between LVs and HB pacing. CONCLUSIONS: LVs pacing provides short-term hemodynamic improvement and electrical resynchronization that is at least as good as during BiV and possibly HB pacing. These results indicate that LVs pacing may serve as a valuable alternative for CRT.


Subject(s)
Cardiac Resynchronization Therapy/methods , Electrophysiological Phenomena , Heart Ventricles/physiopathology , Hemodynamics , Aged , Bundle-Branch Block/therapy , Electrocardiography , Electrodes , Female , Fluoroscopy , Heart Failure/physiopathology , Heart Septum/pathology , Humans , Male , Middle Aged , Prospective Studies , Ventricular Function, Left
14.
Eur Heart J Digit Health ; 1(1): 40-50, 2020 Nov.
Article in English | MEDLINE | ID: mdl-36713963

ABSTRACT

Aims: The relative impact of left ventricular (LV) diastolic dysfunction (LVDD) and impaired left atrial (LA) function on cardiovascular haemodynamics in heart failure with preserved ejection fraction (HFpEF) is largely unknown. We performed virtual patient simulations to elucidate the relative effects of these factors on haemodynamics at rest and during exercise. Methods and results: The CircAdapt cardiovascular system model was used to simulate cardiac haemodynamics in wide ranges of impaired LV relaxation function, increased LV passive stiffness, and impaired LA function. Simulations showed that LV ejection fraction (LVEF) was preserved (>50%), despite these changes in LV and LA function. Impairment of LV relaxation function decreased E/A ratio and mildly increased LV filling pressure at rest. Increased LV passive stiffness resulted in increased E/A ratio, LA dilation and markedly elevated LV filling pressure. Impairment of LA function increased E/A ratio and LV filling pressure, explaining inconsistent grading of LVDD using echocardiographic indices. Exercise simulations showed that increased LV passive stiffness exerts a stronger exercise-limiting effect than impaired LV relaxation function does, especially with impaired LA function. Conclusion: The CircAdapt model enabled realistic simulation of virtual HFpEF patients, covering a wide spectrum of LVDD and related limitations of cardiac exercise performance, all with preserved resting LVEF. Simulations suggest that increased LV passive stiffness, more than impaired relaxation function, reduces exercise tolerance, especially when LA function is impaired. In future studies, the CircAdapt model can serve as a valuable platform for patient-specific simulations to identify the disease substrate(s) underlying the individual HFpEF patient's cardiovascular phenotype.

15.
EuroIntervention ; 15(10): 902-911, 2019 Nov 20.
Article in English | MEDLINE | ID: mdl-31746755

ABSTRACT

AIMS: Correction of mitral and/or tricuspid regurgitation (MR, TR) frequently leads to poor outcomes in the days following intervention. We sought to understand how abrupt correction of MR and TR affects ventricular load and to investigate if gradual correction is beneficial. METHODS AND RESULTS: MR and TR were simulated using the CircAdapt cardiovascular system model with effective regurgitant orifice (ERO) areas of 0.5 cm2 and 0.7 cm2. Ventricular and atrial contractility reductions to 40% of normal and pulmonary hypertension were simulated. Abrupt and gradual ERO closure were simulated with homeostatic regulation of blood pressure and volume. Abrupt correction of MR increased left and right ventricular fibre stress by 40% and 15%, respectively, whereas TR correction increased left and right ventricular fibre stress by 26% and 19%, respectively. This spike was followed by a rapid drop in fibre stress. Myocardial dysfunction prolonged the spike but reduced its amplitude. Right ventricular fibre stress increased more with pulmonary hypertension and TR. Gradual correction demonstrated no spike in tissue load. CONCLUSIONS: Simulations demonstrated that abrupt ERO closure creates a transient increase in ventricular load that is prolonged by worsened myocardial condition and exacerbated by pulmonary hypertension. Gradual closure of the ERO abolishes this spike and merits clinical investigation.


Subject(s)
Hypertension, Pulmonary , Mitral Valve Insufficiency , Tricuspid Valve Insufficiency , Heart Atria , Heart Ventricles , Humans
16.
J Cardiovasc Electrophysiol ; 30(9): 1610-1619, 2019 09.
Article in English | MEDLINE | ID: mdl-31115945

ABSTRACT

INTRODUCTION: New pacing technologies offer a greater choice of left ventricular pacing sites and greater personalization of cardiac resynchronization therapy (CRT). The effects on cardiac function of novel pacing configurations are often compared using multi-beat averages of acute hemodynamic measurements. In this analysis of the iSpot trial, we explore whether this is sufficient. MATERIALS AND METHODS: The iSpot trial was an international, prospective, acute hemodynamic trial that assessed seven CRT configurations: standard CRT, MultiSpot (posterolateral vein), and MultiVein (anterior and posterior vein) pacing. Invasive and noninvasive blood pressure, and left ventricular (LV) dP/dtmax were recorded. Eight beats were recorded before and after an alternation from AAI to the tested pacing configuration and vice-versa. Eight alternations were performed for each configuration at each of the five atrioventricular delays. RESULTS: Twenty-five patients underwent the full protocol of eight alternations. Only four (16%) patients had a statistically significant >3 mm Hg improvement over conventional CRT configuration (posterolateral vein, distal electrode). However, if only one alternation was analyzed (standard multi-beat averaging protocol), 15 (60%) patients falsely appeared to have a superior nonconventional configuration. Responses to pacing were significantly correlated between the different hemodynamic measures: invasive systolic blood pressure (SBP) vs noninvasive SBP r = 0.82 (P < .001); invasive SBP vs LV dP/dt r = 0.57, r2 = 0.32 (P < .001). CONCLUSIONS: Current standard multibeat acquisition protocols are unfortunately unable to prevent false impressions of optimality arising in individual patients. Personalization processes need to include distinct repeated transitions to the tested pacing configuration in addition to averaging multiple beats. The need is not only during research stages but also during clinical implementation.


Subject(s)
Bundle-Branch Block/therapy , Cardiac Resynchronization Therapy , Heart Failure/therapy , Hemodynamic Monitoring , Hemodynamics , Blood Pressure , Bundle-Branch Block/diagnosis , Bundle-Branch Block/physiopathology , Heart Failure/diagnosis , Heart Failure/physiopathology , Heart Rate , Humans , Predictive Value of Tests , Prospective Studies , Time Factors , Treatment Outcome , Ventricular Function, Left , Ventricular Pressure
17.
Int J Cardiol Heart Vasc ; 19: 14-19, 2018 Jun.
Article in English | MEDLINE | ID: mdl-29946558

ABSTRACT

BACKGROUND: We sought to determine whether presence, amount and distribution of scar impacts the degree of acute hemodynamic response (AHR) with multisite pacing.Multi-vein pacing (MVP) or multipolar pacing (MPP) with a multi-electrode left ventricular (LV) lead may offer benefits over conventional biventricular pacing in patients with myocardial scar. METHODS: In this multi-center study left bundle branch block patients underwent an hemodynamic pacing study measuring LV dP/dtmax. Patients had cardiac magnetic resonance scar imaging to assess the effect of scar presence, amount and distribution on AHR. RESULTS: 24 patients (QRS 171 ±â€¯20 ms) completed the study (83% male). An ischemic etiology was present in 58% and the mean scar volume was 6.0 ±â€¯7.0%. Overall discounting scar, MPP and MVP showed no significant AHR increase compared to an optimized "best BiV" (BestBiV) site. In a minority of patients (6/24) receiver-operator characteristic analysis of scar volume (cut off 8.48%) predicted a small AHR improvement with MPP (sensitivity 83%, specificity 94%) but not MVP. Patients with scar volume > 8.48% had a MPP-BestBiV of 3 ±â€¯6.3% vs. -6.4 ±â€¯7.7% for those below the cutoff. There was a significant correlation between the difference in AHR and scar volume for MPP-BestBiV (R = 0.49, p = 0.02) but not MVP-BestBiV(R = 0.111, p = 0.62). The multielectrode lead positioned in scar predicted MPP AHR improvement (p = 0.04). CONCLUSIONS: Multisite pacing with MPP and MVP shows no AHR benefit in all-comers compared to optimized BestBiV pacing. There was a minority of patients with significant scar volume in relation to the LV site that exhibited a small AHR improvement with MPP.(Study identifier NCT01883141).

18.
Europace ; 20(8): 1294-1302, 2018 08 01.
Article in English | MEDLINE | ID: mdl-29036446

ABSTRACT

Aims: A difficult cardiac resynchronization therapy (CRT) implantation scenario emerges when no lateral pacing option exists. The aim of this study was to explore the effect of biventricular pacing (BIVP) on vectorcardiographic parameters in patients with a non-lateral left ventricular (LV) lead position. We hypothesized that perimeter and area reduction for both the QRS complex and T-wave would predict acute CRT response. Methods and results: Twenty-six patients (14 ischaemic) with a mean age of 63 ± 10 years and standard CRT indication underwent device implantation with continuous LV pressure registration. The LV lead was placed in either an anterior or apical position. Biventricular pacing was performed at a rate 10% above intrinsic rhythm with acute CRT response defined as LV ΔdP/dtmax >10%. Using this criterion 12 patients were identified as acute CRT responders (responders: 16.7 ± 4.8% vs. non-responders: 1.9 ± 5.3%, P < 0.001). Vectorcardiographic assessment of the QRS complex and T-wave were performed at baseline and under BIVP. Based on the observed changes in three-dimensional area and perimeter, ΔQRS-area (responders: -46.7 ± 39.6% vs. non-responders: 1.1 ± 50.9%, P = 0.006) was considered as the preferred parameter. Receiver operating characteristic curve analysis identified -40% as the optimal cut-off value (sensitivity 67% and specificity 93%) for prediction of acute CRT response (AUC = 0.81, P < 0.01). A significant correlation was observed between LV ΔdP/dtmax and ΔQRS-area (R2 = 0.37, P = 0.001). Conclusion: ΔQRS-area is correlated to LV ΔdP/dtmax and predicts acute CRT response in patients with a non-lateral LV lead position. Assessment of ΔQRS-area might be a useful tool for patient specific LV lead placement when no lateral pacing option exists.


Subject(s)
Cardiac Resynchronization Therapy/methods , Heart Failure/therapy , Vectorcardiography , Ventricular Function, Left , Ventricular Pressure , Action Potentials , Aged , Cardiac Resynchronization Therapy/adverse effects , Cardiac Resynchronization Therapy Devices , Female , Heart Failure/diagnosis , Heart Failure/physiopathology , Heart Rate , Humans , Male , Middle Aged , Predictive Value of Tests , Recovery of Function , Time Factors , Treatment Outcome
19.
Open Heart ; 5(2): e000874, 2018.
Article in English | MEDLINE | ID: mdl-30613408

ABSTRACT

Background: Patient-specific left ventricular (LV) lead optimisation strategies with immediate feedback on cardiac resynchronisation therapy (CRT) effectiveness are needed. The purpose of this study was to compare contractility surrogates derived from biventricular lead motion analysis to the peak positive time derivative of LV pressure (dP/dtmax) in patients undergoing CRT implantation. Methods: Twenty-seven patients underwent CRT implantation with continuous haemodynamic monitoring. The right ventricular (RV) lead was placed in apex and a quadripolar LV lead was placed laterally. Biplane fluoroscopy cine films facilitated construction of three-dimensional RV-LV interlead distance waveforms at baseline and under biventricular pacing (BIVP) from which the following contractility surrogates were derived; fractional shortening (FS), time to peak systolic contraction and peak shortening of the interlead distance (negative slope). Acute haemodynamic CRT response was defined as LV ∆dP/dtmax ≥ 10 %. Results: We observed a mean increase in dP/dtmax under BIVP (899±205 mm Hg/s vs 777±180 mm Hg/s, p<0.001). Based on ΔdP/dtmax, 18 patients were classified as acute CRT responders and nine as non-responders (23.3%±10.6% vs 1.9±5.3%, p<0.001). The baseline RV-LV interlead distance was associated with echocardiographic LV dimensions (end diastole: R=0.61, p=0.001 and end systole: R=0.54, p=0.004). However, none of the contractility surrogates could discriminate between the acute CRT responders and non-responders (ΔFS: -2.5±2.6% vs - 2.0±3.1%, p=0.50; Δtime to peak systolic contraction: -9.7±18.1% vs -10.8±15.1%, p=0.43 and Δpeak negative slope: -8.7±45.9% vs 12.5±54.8 %, p=0.09). Conclusion: The baseline RV-LV interlead distance was associated with echocardiographic LV dimensions. In CRT recipients, contractility surrogates derived from the RV-LV interlead distance waveform could not discriminate between acute haemodynamic responders and non-responders.

20.
J Cardiovasc Electrophysiol ; 28(2): 192-200, 2017 02.
Article in English | MEDLINE | ID: mdl-27885752

ABSTRACT

INTRODUCTION: Vectorcardiographic (VCG) QRS area of left bundle branch block (LBBB) predicts acute hemodynamic response in cardiac resynchronization therapy (CRT) patients. We hypothesized that changes in QRS area occurring with biventricular pacing (BV) might predict acute hemodynamic CRT response (AHR). METHODS AND RESULTS: VCGs of 624 BV paced electrocardiograms (25 LBBB patients with 35 different pacing configurations) were calculated according to Frank's orthogonal lead system. Maximum QRS vector amplitudes (XAmpl , YAmpl , ZAmpl , and 3DAmp ) and QRS areas (XArea , YArea , ZArea , and 3DArea ) in the orthogonal leads (X, Y, and Z) and in 3-dimensional projection were measured. Volume of the 3D vector loop and global QRS duration (QRSD) on the surface electrocardiogram were assessed. Differences (Δ) in VCG parameters between BV paced and LBBB QRS complexes were calculated. An increase of 10% in dP/dt max was considered as AHR. LBBB conduction is characterized by a large ZArea (109 µVs, interquartile range [IQR]:75;135), significantly larger than XArea (22 µVs, IQR:10;57) and YArea (44 µVs, IQR:32;62, P < 0.001). Overall, QRS duration, amplitudes, and areas decrease significantly with BV pacing (P < 0.001). Of all VCG parameters, 3DAmpl , Δ3DAmpl , ZArea, ΔZArea , Δ3DArea , and ΔQRSD differentiate AHR response from nonresponse (P < 0.05). ΔZArea predicted best positive AHR (area under the curve = 0.813) and outperformed any other VCG parameter or QRSD measurement. CONCLUSION: Of all VCG parameters, reduction in QRS area, calculated in Frank's Z lead, predicts acute hemodynamic response best. This method might be an easy, noninvasive tool to guide CRT implantation and optimization.


Subject(s)
Action Potentials , Bundle-Branch Block/therapy , Cardiac Resynchronization Therapy , Electrocardiography , Heart Rate , Aged , Area Under Curve , Bundle-Branch Block/diagnosis , Bundle-Branch Block/physiopathology , Europe , Female , Humans , Male , Middle Aged , Middle East , Predictive Value of Tests , Prospective Studies , ROC Curve , Stroke Volume , Time Factors , Treatment Outcome , Vectorcardiography , Ventricular Function, Left