Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 38
Filter
1.
Rev Bras Ortop (Sao Paulo) ; 59(1): e130-e135, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38524711

ABSTRACT

Rapid prototyping technology, known as three-dimensional (3D) printing, and its use in the medical field are advancing. Studies on severe bone deformity treatment with 3D printing showed benefits in postoperative outcomes thanks to this technology. Even so, preoperative planning guidance for surgeons is lacking. This technical note describes a practical step-by-step guide to help surgeons use this technology to optimize the therapeutic plan with free license software and an intuitive interface. This study aims to organize the 3D modeling process using a preoperative computed tomography (CT) scan. This technology allows a deeper understanding of the case and its particularities, such as the direction, planes, and dimensions of the deformity. Planning considering these topics may reduce the surgical time and result in better functional outcomes by understanding the deformity and how to correct it. Associating planning via software with 3D printing can further enhance this therapeutic method.

2.
Rev. bras. ortop ; 59(1): 130-135, 2024. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1559614

ABSTRACT

Abstract Rapid prototyping technology, known as three-dimensional (3D) printing, and its use in the medical field are advancing. Studies on severe bone deformity treatment with 3D printing showed benefits in postoperative outcomes thanks to this technology. Even so, preoperative planning guidance for surgeons is lacking. This technical note describes a practical step-by-step guide to help surgeons use this technology to optimize the therapeutic plan with free license software and an intuitive interface. This study aims to organize the 3D modeling process using a preoperative computed tomography (CT) scan. This technology allows a deeper understanding of the case and its particularities, such as the direction, planes, and dimensions of the deformity. Planning considering these topics may reduce the surgical time and result in better functional outcomes by understanding the deformity and how to correct it. Associating planning via software with 3D printing can further enhance this therapeutic method.


Resumo Observa-se o avanço da tecnologia de prototipagem rápida, conhecida como impressão tridimensional (3D) e seu uso na área médica. Existem estudos a respeito do tratamento de deformidades ósseas graves com impressão 3D, os quais mostram benefícios no resultado pós-operatório às custas do uso da tecnologia em questão. Ainda assim, nota-se a escassez quando o assunto é disponibilizar ao cirurgião orientações para planejamento pré-operatório. O objetivo desta nota técnica é descrever um passo-a-passo prático para auxiliar cirurgiões a utilizarem a tecnologia como ferramenta para otimizar o plano terapêutico, dispondo de um programa de licença gratuita e de interface intuitiva. Este é um estudo que visa a organização do processo de modelagem 3D, no qual foi utilizado um exame de tomografia computadorizada (TC) pré-operatória. Com esta tecnologia, é possível uma compreensão mais profunda do caso e suas particularidades como direção, planos e dimensões das deformidades. Acredita-se que um planejamento que leve em consideração tais tópicos gera redução do tempo cirúrgico e melhores resultados funcionais devido ao entendimento da deformidade e maneiras de correção. Associar o planejamento via software com a impressão 3D pode potencializar ainda mais na elaboração do método terapêutico.

3.
Rev Bras Ortop (Sao Paulo) ; 58(2): 191-198, 2023 Apr.
Article in English | MEDLINE | ID: mdl-37252311

ABSTRACT

Historically, surgeries on the immature skeleton were reserved for open or articular fractures. In recent years, the improvement in the quality and safety of anesthesia, new imaging equipment, implants designed especially for pediatric fractures, associated with the possibility of shorter hospitalization time and rapid return to social life has demonstrated a new tendency to evaluate and treat fractures in children. The purpose of this update article is to answer the following questions: (1) Are we really turning more surgical in addressing fractures in children? (2) If this is true, is this surgical conduct based on scientific evidence? In fact, in recent decades, the medical literature demonstrates articles that support better evolution of fractures in children with surgical treatment. In the upper limbs, this is very evident in the systematization of the reduction and percutaneous fixation of supracondylar fractures of the humerus and fractures of the forearm bones. In the lower limbs, the same occurs with diaphyseal fractures of the femur and tibia. However, there are gaps in the literature. The available published studies show low scientific evidence. Thus, it can be inferred that, even though the surgical approach is more present, the treatment of pediatric fractures should always be individualized and conducted according to the knowledge and experience of the professional physician, taking into account the presence of technological resources available for the care of the small patient. All possibilities, non-surgical and/or surgical, should be included, always instituting actions based on science and in agreement with the family's wishes.

4.
Rev. bras. ortop ; 58(2): 191-198, Mar.-Apr. 2023. graf
Article in English | LILACS | ID: biblio-1449794

ABSTRACT

Abstract Historically, surgeries on the immature skeleton were reserved for open or articular fractures. In recent years, the improvement in the quality and safety of anesthesia, new imaging equipment, implants designed especially for pediatric fractures, associated with the possibility of shorter hospitalization time and rapid return to social life has demonstrated a new tendency to evaluate and treat fractures in children. The purpose of this update article is to answer the following questions: (1) Are we really turning more surgical in addressing fractures in children? (2) If this is true, is this surgical conduct based on scientific evidence? In fact, in recent decades, the medical literature demonstrates articles that support better evolution of fractures in children with surgical treatment. In the upper limbs, this is very evident in the systematization of the reduction and percutaneous fixation of supracondylar fractures of the humerus and fractures of the forearm bones. In the lower limbs, the same occurs with diaphyseal fractures of the femur and tibia. However, there are gaps in the literature. The available published studies show low scientific evidence. Thus, it can be inferred that, even though the surgical approach is more present, the treatment of pediatric fractures should always be individualized and conducted according to the knowledge and experience of the professional physician, taking into account the presence of technological resources available for the care of the small patient. All possibilities, non-surgical and/or surgical, should be included, always instituting actions based on science and in agreement with the family's wishes.


Resumo Historicamente, as cirurgias no esqueleto imaturo eram reservadas às fraturas expostas ou articulares. Nos últimos anos, a melhora na qualidade e segurança das anestesias, novos equipamentos de imagem, implantes desenhados especialmente para fraturas pediátricas, associados à possibilidade de menor tempo de hospitalização e rápido retorno ao convívio social vêm demonstrando uma nova tendência de avaliar e tratar fraturas na criança. O objetivo deste artigo de atualização é responder às seguintes questões: (1) estamos realmente ficando mais cirúrgicos na abordagem das fraturas em crianças? (2) Caso isto seja verdadeiro, esta conduta cirúrgica está baseada em evidências científicas? De fato, nas últimas décadas, a literatura médica demonstra artigos que suportam melhor evolução das fraturas na criança com o tratamento cirúrgico. Nos membros superiores, isto fica muito evidente na sistematização da redução e fixação percutânea das fraturas supracondilianas do úmero e das fraturas de ossos do antebraço. Nos membros inferiores, o mesmo ocorre com fraturas diafisárias do fêmur e tíbia. No entanto, há lacunas na literatura. Os estudos publicados são geralmente com baixa evidência científica. Assim, pode-se deduzir que, mesmo sendo a abordagem cirúrgica mais presente, o tratamento de fraturas pediátricas deve ser sempre individualizado e conduzido de acordo com o conhecimento e experiência do médico profissional, levando em conta a presença de recursos tecnológicos disponíveis para o atendimento do pequeno paciente. Deve-se incluir todas as possibilidades, não cirúrgicas e/ou cirúrgicas, sempre instituindo ações baseadas na ciência e em concordância com os anseios da família.


Subject(s)
Humans , Child, Preschool , Child , Fractures, Bone , Salter-Harris Fractures , Fracture Fixation, Internal , Growth Plate/surgery
5.
Rev Bras Ortop (Sao Paulo) ; 54(6): 665-672, 2019 Dec.
Article in English | MEDLINE | ID: mdl-31875065

ABSTRACT

Objective To develop a predictive model of early postoperative morbidity and mortality with the purpose of assisting in the selection of the candidates for spinal metastasis surgery. Methods A retrospective analysis of consecutive patients operated for metastatic spinal disease. The possible prognostic preoperative characteristics were gender, age, comorbidities, tumor growth rate, and leukocyte and lymphocyte count in the peripheral blood. The postoperative outcomes were 30-day mortality, 90-day mortality and presence of complications. A predictive model was developed based on factors independently associated with these three outcomes. The final model was then tested for the tendency to predict adverse events, discrimination capacity and calibration. Results A total of 205 patients were surgically treated between 2002 and 2015. The rates of the 30-day mortality, 90-day mortality and presence of complications were of 17%, 42% and 31% respectively. The factors independently associated with these three outcomes, which constituted the predictive model, were presence of comorbidities, no slow-growing primary tumor, and lymphocyte count below 1,000 cells/µL. Exposure to none, one, two or three factors was the criterion for the definition of the following categories of the predictive model: low, moderate, high and extreme risk respectively. Comparing the risk categories, there was a progressive increase in the occurrence of outcomes, following a linear trend. The discrimination capacity was of 72%, 73% and 70% for 30-day mortality, 90-day mortality and complications respectively. No lack of calibration occurred. Conclusion The predictive model estimates morbidity and mortality after spinal metastasis surgery and hierarchizes risks as low, moderate, high and extreme.

6.
Rev. bras. ortop ; 54(6): 665-672, Nov.-Dec. 2019. tab, graf
Article in English | LILACS | ID: biblio-1057956

ABSTRACT

Abstract Objective To develop a predictive model of early postoperative morbidity and mortality with the purpose of assisting in the selection of the candidates for spinal metastasis surgery. Methods A retrospective analysis of consecutive patients operated for metastatic spinal disease. The possible prognostic preoperative characteristics were gender, age, comorbidities, tumor growth rate, and leukocyte and lymphocyte count in the peripheral blood. The postoperative outcomes were 30-day mortality, 90-day mortality and presence of complications. A predictive model was developed based on factors independently associated with these three outcomes. The final model was then tested for the tendency to predict adverse events, discrimination capacity and calibration. Results A total of 205 patients were surgically treated between 2002 and 2015. The rates of the 30-day mortality, 90-day mortality and presence of complications were of 17%, 42% and 31% respectively. The factors independently associated with these three outcomes, which constituted the predictive model, were presence of comorbidities, no slow-growing primary tumor, and lymphocyte count below 1,000 cells/µL. Exposure to none, one, two or three factors was the criterion for the definition of the following categories of the predictive model: low, moderate, high and extreme risk respectively. Comparing the risk categories, there was a progressive increase in the occurrence of outcomes, following a linear trend. The discrimination capacity was of 72%, 73% and 70% for 30-day mortality, 90-day mortality and complications respectively. No lack of calibration occurred. Conclusion The predictive model estimates morbidity and mortality after spinal metastasis surgery and hierarchizes risks as low, moderate, high and extreme.


Resumo Objetivo Desenvolver um modelo preditivo de morbimortalidade pós-operatória precoce com o intuito de auxiliar na seleção dos candidatos à cirurgia para metástase vertebral. Métodos Análise retrospectiva de pacientes consecutivos operados por doença metastática vertebral. As características pré-operatórias consideradas possivelmente prognósticas foram: sexo, idade, comorbidades, velocidade de progressão tumoral e contagem de leucócitos e linfócitos no sangue periférico. Os desfechos pós-operatórios analisados foram: mortalidade em 30 dias e em 90 dias, e presença de complicações. Um modelo preditivo foi desenvolvido a partir de fatores independentemente associados a esses três desfechos. Testou-se então o modelo estabelecido quanto à tendência de prever eventos adversos, à capacidade de discriminação e à calibração. Resultados Um total de 205 pacientes foram operados entre 2002 e 2015. A mortalidade em 30 dias e em 90 dias e a incidência de complicações foram de 17%, 42% e 31%, respectivamente. Os fatores independentemente associados a esses três desfechos, e que constituíram o modelo preditivo, foram: presença de comorbidades, tumor primário de progressão não lenta, e linfócitos abaixo de 1.000 células/µL. A exposição a nenhum, um, dois ou três fatores definiu as categorias do modelo preditivo: baixo, moderado, alto e de extremo risco, respectivamente. Comparando-se as categorias, houve aumento progressivo na ocorrência dos desfechos, seguindo tendência linear. A capacidade de discriminação foi de 72%, 73% e 70% para mortalidade em 30 dias, em 90 dias e incidência de complicações, respectivamente. Não ocorreu falta de calibração. Conclusão O modelo preditivo permite estimar a morbimortalidade após a cirurgia para metástase vertebral e hierarquizar os riscos em baixo, moderado, alto e extremo.


Subject(s)
Humans , Male , Female , Postoperative Complications , Spinal Diseases , Spine/surgery , Lymphocytes , Comorbidity , Indicators of Morbidity and Mortality , Morbidity , Mortality , Lymphocyte Count , Neoplasm Metastasis
7.
J Pediatr Orthop B ; 28(6): 559-563, 2019 Nov.
Article in English | MEDLINE | ID: mdl-31356504

ABSTRACT

The supracondylar humerus fracture is the most common elbow fracture in children, corresponding to 58% of these cases. The objective of this study is to report a rare postoperative complication, the pseudoaneurysm of the brachial artery. A 9-year-old girl with was admitted with a Gartland III supracondylar fracture of the right humerus, presenting normal neurological and vascular exams. The patient underwent a surgical treatment with percutaneous fixation and immobilization and was re-evaluated after 2 and 4 weeks. In the last evaluation the immobilization and fixation were removed. She returned after 3 months, presenting a progressive palpable, painless mass in the 1/3 distal right arm. The arterial ultrasound showed a mass in the cubital fossa, which presented internal flow and some wall thrombi, compatible with pseudoaneurysm of the brachial artery. After diagnosis, the treatment was a vascular surgery for dissection and reconstruction of the artery. The incidence of vascular involvement in Gartland III fractures ranges from 2% to 38%. False aneurysms originate from arterial hematomas caused by trauma to the arterial lumen, and their developing time can vary. There are few reports of this complication, so there is no consensus about the treatment.


Subject(s)
Aneurysm, False/diagnostic imaging , Brachial Artery/diagnostic imaging , Fracture Fixation, Internal/adverse effects , Humeral Fractures/diagnostic imaging , Humeral Fractures/surgery , Aneurysm, False/etiology , Child , Female , Fracture Fixation, Internal/trends , Humans
8.
Rev. bras. ortop ; 53(5): 564-569, Sept.-Oct. 2018. tab, graf
Article in English | LILACS | ID: biblio-977875

ABSTRACT

ABSTRACT Objective: The aim of the study was to compare the mechanical behavior of interference screw tibial fixation vs. screw-plus-staple tibial fixation in an animal model. Methods: Thirty-six pieces of swine knee specimens were selected and divided into two groups: Group 1, tibial fixation with interference screw (n = 17), and Group 2, fixation with interference screw and staple (n = 19). The models were submitted to a single cycle of tension testing. The following variables were measured: graft cross-sectional area, failure point on 10 mm (F10), yield load (Fy), and stiffness. Results: The mean values of graft cross-sectional area, F10, Fy, and stiffness did not present significant differences between the groups. Conclusion: The addition of a second staple-type ligament fixation device, complementing the interference screw, did not increase the mechanical safety of the system.


RESUMO Objetivo: Comparar o comportamento mecânico da fixação tibial com parafuso de interferência versus parafuso de interferência com agrafe, em modelo animal. Métodos: Foram selecionadas 36 peças de joelho suíno e divididas em dois grupos: Grupo 1, fixação tibial com parafuso de interferência (n = 17) e Grupo 2, fixação com parafuso de interferência e agrafe (n = 19). Os modelos foram submetidos a teste de ciclo único de tração. Foram mensuradas as seguintes variáveis: medida da área de seção transversal do enxerto, ponto de falha nos 10 mm (F10), yield load (Fy) e rigidez. Resultados: Os valores médios de área de seção transversal do enxerto, F10, Fy, e rigidez não apresentaram diferenças significativas entre os grupos. Conclusão: A adição de um segundo dispositivo de fixação ligamentar tibial tipo agrafe, complementar ao parafuso de interferência, não aumentou a segurança mecânica do sistema.


Subject(s)
Animals , Orthopedic Fixation Devices , Tendons , Tibia , Biomechanical Phenomena , Anterior Cruciate Ligament
9.
Rev Bras Ortop ; 53(5): 564-569, 2018.
Article in English | MEDLINE | ID: mdl-30245995

ABSTRACT

OBJECTIVE: The aim of the study was to compare the mechanical behavior of interference screw tibial fixation vs. screw-plus-staple tibial fixation in an animal model. METHODS: Thirty-six pieces of swine knee specimens were selected and divided into two groups: Group 1, tibial fixation with interference screw (n = 17), and Group 2, fixation with interference screw and staple (n = 19). The models were submitted to a single cycle of tension testing. The following variables were measured: graft cross-sectional area, failure point on 10 mm (F10), yield load (Fy), and stiffness. RESULTS: The mean values of graft cross-sectional area, F10, Fy, and stiffness did not present significant differences between the groups. CONCLUSION: The addition of a second staple-type ligament fixation device, complementing the interference screw, did not increase the mechanical safety of the system.


OBJETIVO: Comparar o comportamento mecânico da fixação tibial com parafuso de interferência versus parafuso de interferência com agrafe, em modelo animal. MÉTODOS: Foram selecionadas 36 peças de joelho suíno e divididas em dois grupos: Grupo 1, fixação tibial com parafuso de interferência (n = 17) e Grupo 2, fixação com parafuso de interferência e agrafe (n = 19). Os modelos foram submetidos a teste de ciclo único de tração. Foram mensuradas as seguintes variáveis: medida da área de seção transversal do enxerto, ponto de falha nos 10 mm (F10), yield load (Fy) e rigidez. RESULTADOS: Os valores médios de área de seção transversal do enxerto, F10, Fy, e rigidez não apresentaram diferenças significativas entre os grupos. CONCLUSÃO: A adição de um segundo dispositivo de fixação ligamentar tibial tipo agrafe, complementar ao parafuso de interferência, não aumentou a segurança mecânica do sistema.

10.
Rev Bras Ortop ; 53(3): 293-299, 2018.
Article in English | MEDLINE | ID: mdl-29892579

ABSTRACT

OBJECTIVE: To analyze, from the immunohistochemical perspective, the effects of hyaluronic acid of different molecular weights in an experimental model of osteoarthritis in rabbits. METHODS: Forty-four male California rabbits were randomly assigned to three different groups (PR, S, and P) and submitted to the resection of the anterior cruciate ligament of the right knee. Three weeks after the surgical procedure, three intra-articular weekly injections were carried out with low-molecular-weight native hyaluronic acid (Hyalgan®) to PR group, high molecular weight branched chain hyaluronic acid (Synvisc®) to group S, and saline solution 0.9% to group P. All animals were sacrificed 12 weeks after the surgical procedure, and the tibial plateaus of the infiltrated knees were then dissected. Histological sections of cartilage from the tibial plateau support areas were stained with immunohistochemical markers in order to investigate the amount of metalloproteases (MMPs 3 and 13) and their inhibitors (TIMPs 1 and 3). The staining intensity was quantified on a Zeiss Imager.Z2 Metasystems microscope and analyzed by Metafer4 Msearch software. RESULTS: The chondroprotective effect of the hyaluronic acids used in the study was demonstrated when compared to the control group. However, the comparison between them presented no significant statistical difference regarding chondroprotection. CONCLUSION: The injection of saline solution demonstrated signs of OA development, while adding native hyaluronic acid of low molecular weight (Hyalgan®) and hyaluronic acid of high molecular weight (Synvisc®) protected the articular cartilage in this model of OA.


OBJETIVO: Analisar do ponto de vista imuno-histoquímico os efeitos do ácido hialurônico de diferentes pesos moleculares em modelo experimental em coelhos. MÉTODOS: Foram alocados de modo aleatório 44 coelhos da raça California, machos, em três grupos (PR, S e P), e submetidos à ressecção do ligamento cruzado anterior do joelho direito. Decorridas três semanas do procedimento cirúrgico iniciaram-se as três injeções intra-articulares semanais de ácido hialurônico nativo de baixo peso molecular (Polireumin®) no grupo PR, ácido hialurônico de cadeia ramificada de alto peso molecular (Synvisc®) no grupo S e soro fisiológico 0,9% no grupo P. Todos os animais foram sacrificados após 12 semanas do ato cirúrgico e os platôs tibiais dos joelhos infiltrados foram dissecados. Cortes histológicos da cartilagem das áreas de apoio dos platôs tibiais foram corados com marcadores imuno-histoquímicos para pesquisa da quantidade de metaloproteases (MMPs-3,13) e seus inibidores (TIMPs-1,3). A intensidade de coloração foi quantificada em um aparelho de microscopia Zeiss Imager.Z2 Metasystems e analisada pelo software Metafer4 Msearch. RESULTADO: O efeito condroprotetor dos ácidos hialurônicos usados no estudo foi demonstrado quando comparados com o grupo controle, porém feita a comparação entre si não houve diferença estatística significante quanto à condroproteção. CONCLUSÃO: A injeção de solução salina demonstra sinais de desenvolvimento de OA enquanto que a adição de ácido hialurônico nativo de baixo peso molecular (Polireumin®) e ácido hialurônico de cadeia ramificada de alto peso molecular (Synvisc®) protegeram a cartilagem articular nesse modelo de OA.

11.
Rev. bras. ortop ; 53(3): 293-299, May-June 2018. tab, graf
Article in English | LILACS | ID: biblio-959152

ABSTRACT

ABSTRACT Objective: To analyze, from the immunohistochemical perspective, the effects of hyaluronic acid of different molecular weights in an experimental model of osteoarthritis in rabbits. Methods: Forty-four male California rabbits were randomly assigned to three different groups (PR, S, and P) and submitted to the resection of the anterior cruciate ligament of the right knee. Three weeks after the surgical procedure, three intra-articular weekly injections were carried out with low-molecular-weight native hyaluronic acid (Hyalgan®) to PR group, high molecular weight branched chain hyaluronic acid (Synvisc®) to group S, and saline solution 0.9% to group P. All animals were sacrificed 12 weeks after the surgical procedure, and the tibial plateaus of the infiltrated knees were then dissected. Histological sections of cartilage from the tibial plateau support areas were stained with immunohistochemical markers in order to investigate the amount of metalloproteases (MMPs 3 and 13) and their inhibitors (TIMPs 1 and 3). The staining intensity was quantified on a Zeiss Imager.Z2 Metasystems microscope and analyzed by Metafer4 Msearch software. Results: The chondroprotective effect of the hyaluronic acids used in the study was demonstrated when compared to the control group. However, the comparison between them presented no significant statistical difference regarding chondroprotection. Conclusion: The injection of saline solution demonstrated signs of OA development, while adding native hyaluronic acid of low molecular weight (Hyalgan®) and hyaluronic acid of high molecular weight (Synvisc®) protected the articular cartilage in this model of OA.


RESUMO Objetivo: Analisar do ponto de vista imuno-histoquímico os efeitos do ácido hialurônico de diferentes pesos moleculares em modelo experimental em coelhos. Métodos: Foram alocados de modo aleatório 44 coelhos da raça California, machos, em três grupos (PR, S e P), e submetidos à ressecção do ligamento cruzado anterior do joelho direito. Decorridas três semanas do procedimento cirúrgico iniciaram-se as três injeções intra-articulares semanais de ácido hialurônico nativo de baixo peso molecular (Polireumin®) no grupo PR, ácido hialurônico de cadeia ramificada de alto peso molecular (Synvisc®) no grupo S e soro fisiológico 0,9% no grupo P. Todos os animais foram sacrificados após 12 semanas do ato cirúrgico e os platôs tibiais dos joelhos infiltrados foram dissecados. Cortes histológicos da cartilagem das áreas de apoio dos platôs tibiais foram corados com marcadores imuno-histoquímicos para pesquisa da quantidade de metaloproteases (MMPs-3,13) e seus inibidores (TIMPs-1,3). A intensidade de coloração foi quantificada em um aparelho de microscopia Zeiss Imager.Z2 Metasystems e analisada pelo software Metafer4 Msearch. Resultado: O efeito condroprotetor dos ácidos hialurônicos usados no estudo foi demonstrado quando comparados com o grupo controle, porém feita a comparação entre si não houve diferença estatística significante quanto à condroproteção. Conclusão: A injeção de solução salina demonstra sinais de desenvolvimento de OA enquanto que a adição de ácido hialurônico nativo de baixo peso molecular (Polireumin®) e ácido hialurônico de cadeia ramificada de alto peso molecular (Synvisc®) protegeram a cartilagem articular nesse modelo de OA.


Subject(s)
Animals , Rabbits , Rabbits , Immunohistochemistry , Animal Experimentation , Hyaluronic Acid
12.
Rev. bras. ortop ; 50(2): 174-179, Mar-Apr/2015. tab, graf
Article in English | LILACS | ID: lil-748357

ABSTRACT

OBJECTIVE: To verify whether the combination of tibial cross pin fixation and femoral screw fixation presents biomechanical advantages when compared to femoral cross pin fixation and tibial screw fixation for the reconstruction of the anterior cruciate ligament (ACL). METHODS: Thirty-eight porcine knees and bovine extensor digitorum tendons were used as the graft materials. The tests were performed in three groups: (1) standard, used fourteen knees, and the grafts were fixated with the combination of femoral cross pin and a tibial screw; (2) inverted, used fourteen knees with an inverted combination of tibial cross pin and a femoral screw; (3) control, ten control tests performed with intact ACL. After the grafts fixation, all the knees were subjected to tensile testing to determine yield strength and ultimate strength. RESULTS: There was no statistically significant difference in survival techniques in regard to strength, yield load and tension. There was a higher survival compared in the standard curves of yield stress (p < 0.05). CONCLUSION: There is no biomechanical advantage, observed in animal models testing, in the combination of tibial cross pin fixation and femoral screw when compared to femoral cross pin fixation and tibial screw.


OBJETIVO: investigar se a fixação transversa tibial com parafuso femoral apresenta vantagens biomecânicas sobre a fixação transversa femoral com parafuso tibial na reconstrução do ligamento cruzado anterior (LCA). MÉTODO: foram usados como modelos de testes joelhos suínos e tendões extensores digitais bovinos. Foram submetidos à reconstrução do LCA 28 joelhos: 14 foram fixados com parafuso na tíbia e implante transverso no fêmur (grupo padrão) e 14 com parafuso no fêmur e fixação transversa na tíbia (grupo invertido). Os modelos foram submetidos aos testes de tração. RESULTADOS: não houve diferença estatisticamente significante na sobrevivência das técnicas no que tange a força, força máxima sem falha e tensão. Houve uma sobrevivência maior no grupo padrão na comparação das curvas de tensão de limite elástico (p < 0,05). CONCLUSÃO: não há vantagem biomecânica da fixação transversa tibial com parafuso femoral em relação à fixação transversa femoral com parafuso tibial, observada em testes com modelos animais.


Subject(s)
Animals , Anterior Cruciate Ligament , Femur , Mechanics , Orthopedic Fixation Devices , Tendons , Cattle , Swine
13.
Rev. bras. ortop ; 49(5): 494-498, Sep-Oct/2014. tab, graf
Article in English | LILACS | ID: lil-727690

ABSTRACT

Objective: To study the anatomy of the posterior cruciate ligament (PCL) and define anatomical parameters with the knee flexed at 90°. Methods: Eight knees from cadavers were dissected in order to make measurements from the center of the anterolateral band to the roof (AL1), from the center of the anterolateral band to the anterior cartilage (AL2), from the center of the posteromedial band to the roof (PM1), from the center of the posteromedial band to the anterior cartilage (PM2), from the center of the tibial insertion to the medial region of the tibia (TIM), from the center of the tibial insertion to the lateral region of the tibia (TIL), from the center of the medial insertion to the medial meniscus (IMM) and the width of the origin of the PCL (WO). To obtain the results from each anatomical structure, the means and standard deviations of the measurements were calculated. Results: The measurements in millimeters that were found were AL1, 6.2; AL2, 4.9; PM1, 11.7; PM2, 5.5; TIM, 32.5; TIL, 40.6; IMM, 9.4; and WO, 32.5. Conclusions: The PCL has an extensive origin. The center of the anterolateral band is 6 mm from the roof and 5 mm from the anterior cartilage of the knee. The tibial insertion is slightly medial and 10 mm distal to the posterior cornu of the medial meniscus...


Objetivo: Estudar a anatomia do ligamento cruzado posterior (LCP) e definir parâmetros anatômicos com o joelho em 90° de flexão. Métodos: Oito joelhos de cadáveres foram dissecados para tirar as medidas do centro da banda anterolateral ao teto (AL1), do centro da banda anterolateral à cartilagem anterior (AL2), do centro da banda posteromedial ao teto (PM1), do centro da banda posteromedial à cartilagem anterior (PM2), do centro da inserção tibial à região medial da tíbia (ITM), do centro da inserção tibial à região lateral da tíbia (ITL), do centro da inserção medial ao menisco medial (IMM) e da largura da origem do LCP (LO). Para a obtenção dos resultados de cada estrutura anatômica foram calculados os valores de média e desvio padrão das medições. Resultados: As medidas, em milímetros, encontradas foram AL1, 6,2; AL2, 4,9; PM1, 11,7; PM2, 5,5; ITM, 32,5; ITL, 40,6; IMM, 9,4; e LO, 32,5. Conclusões: o LCP tem uma origem extensa. O centro da banda anterolateral fica a 6 mm do teto e a 5 mm da cartilagem anterior do joelho. A inserção tibial fica levemente medial e 10 mm distal ao corno posterior do menisco medial...


Subject(s)
Humans , Anatomy , Cadaver , Posterior Cruciate Ligament/anatomy & histology
14.
Rev. bras. ortop ; 49(4): 379-385, Jul-Aug/2014. tab, graf
Article in English | LILACS | ID: lil-722699

ABSTRACT

Objective: To compare healing strength of the infraspinatus tendon of rats with corticoid inoculation, regarding maximum tension, maximum force and rupture force, after injury and experimental repair. Methods: A total of 60 Wistar rats were subjected to tenotomy of the infraspinatus tendon, which was then sutured. Before the surgery, they were divided into a control group (C) inoculated with serum and a study group (S) inoculated with corticoids over the tendon. After repair, the rats were sacrificed in groups of 10 individuals in the control group and 10 in the study group at the times of one week (C1 and S1), three weeks (C3 and S3) and five weeks (C5 and S5). The rats were dissected, separating out the infraspinatus tendon with the humerus. The study specimens were subjected to a traction test, with evaluation of the maximum tension (kgf/cm2), maximum force (kgf) and rupture force (kgf), comparing the study group with the respective control groups. Results: Among the rats sacrificed one week after the procedure, we observed greater maximum tension in group C1 than in group S1. The variables of maximum force (kgf) and rupture force did not differ statistically between the groups investigated. In the same way, among the rats sacrificed three weeks after the procedure, group C3 only showed greater maximum tension than group S3 (p = 0.007), and the other variables did not present differences. Among the rats sacrificed five weeks after the procedure (C5 and S5), none of the parameters studied presented statistical differences. Conclusion: We concluded that corticoid diminished the resistance to maximum tension in the groups sacrificed one and three weeks after the procedure, in comparison with the respective control groups. The other parameters did not show differences between the study and control groups...


Objetivo: Comparar a resistência da cicatrização, com relação a tensão máxima, força máxima e força de ruptura, do tendão infraespinhal de ratos submetidos a inoculação de corticoides após a lesão e a reparos experimentais. Métodos: Foram submetidos 60 ratos Wistar a tenotomia do tendão infraespinhal e suturados. Previamente à cirurgia foram divididos em grupo controle (C), inoculados com soro, e grupo de estudo (E), inoculados com corticoides sobre o tendão. Após o reparo os ratos foram sacrificados em grupos de 10 indivíduos do grupo controle e 10 do grupo de estudo em intervalos de uma semana (C1 e E1), três semanas (C3 e E3) e cinco semanas (C5 e E5). Os ratos foram dissecados com a separação do tendão infraespinhal do úmero. As peças de estudo foram submetidas a teste de tração e avaliadas – tensão máxima (kgf/cm2), força máxima (kgf) e força de ruptura (kgf) – e comparando os grupos de estudo com os grupos controle. Resultados: Dentre os ratos sacrificados com uma semana observamos maior tensão máxima do grupo C1 em comparação com o grupo E1. As variáveis força máxima (kgf) e força de ruptura (kgf) não diferiram estatisticamente entre os grupos pesquisados. Da mesma forma, nos ratos sacrificados com três semanas o grupo C3 mostrou apenas resistência maior na tensão máxima em comparação com o grupo E3 (p = 0,007). As demais variáveis não apresentaram diferenças. Nos ratos sacrificados com cinco semanas (C5 e E5), nenhum dos parâmetros estudados apresentou diferenças estatísticas. Conclusão: A inoculação com corticoide sobre o manguito rotador levou a diminuição da resistência a tensão máxima da cicatriz...


Subject(s)
Animals , Rats , Adrenal Cortex Hormones , Rotator Cuff , Tendons
15.
Rev. bras. ortop ; 49(2): 121-128, Mar-Apr/2014. tab, graf
Article in English | LILACS | ID: lil-711166

ABSTRACT

OBJECTIVE: to evaluate the data obtained from patients with transtrochanteric fractures who were attended at a tertiary-level trauma referral hospital, between admission and discharge, gathered prospectively by means of the SINPE(c) software. METHODS: 109 consecutive patients who were admitted between April 2011 and January 2012 were evaluated using an electronic storage and analysis database in SINPE(c) . The data were gathered prospectively, including evaluations on personal information about the patients, history-taking, fracture classification (Evans-Jensen, AO/OTA and Tronzo), treatment and discharge. RESULTS: the sample was composed of 43 men and 66 women. Their ages ranged from 20 to 105 years, with a mean of 69 years. Falling was the trauma mechanism for 92 patients and traffic accidents for 17. The most prevalent chronic diseases were systemic arterial hypertension and diabetes mellitus. According to the AO/OTA classification, the commonest fracture type was 31 A1. According to the Tronzo classification, type III was commonest. The fracture was fixed by means of a cephalomedullary nail in 64 cases and a sliding screw-plate in 44 cases. One fracture was fixed with a 95◦ screw-plate. Seven patients presented some form of clinical complication and three died during the hospital stay. All the patients who were discharged were instructed to only partially bear weight on the repair. CONCLUSION: through SINPE(c) , it was possible to evaluate the personal information, history-taking, classification, treatment and discharge of patients with transtrochanteric fractures, from hospital admission to discharge...


OBJETIVO: avaliar os dados obtidos de pacientes com fratura transtrocantérica atendidos em um hospital de referência terciária de trauma, desde a admissão até a alta hospitalar, coletados prospectivamente por meio do Sinpe(c) . MÉTODOS: foram avaliados 109 pacientes consecutivos admitidos de abril de 2011 até janeiro de 2012. Usou-se uma base eletrônica de armazenamento e análise de dados, o software Sinpe(c) . A coleta dos dados deu-se de maneira prospectiva e informações sobre dados pessoais do paciente, anamnese, classificação das fraturas (Evans-Jensen, AO/OTA e Tronzo), tratamento e alta foram avaliadas. RESULTADOS: a amostra foi composta por 43 homens e 66 mulheres. A idade variou de 20 a 105 anos, com média de 69. A queda foi o mecanismo de trauma em 92 pacientes e os acidentes de trânsito foram em 17. As doenças crônicas mais prevalentes foram a hipertensão arterial sistêmica e o diabetes mellitus. Pela classificação AO/OTA, o tipo mais comum de fratura foi a 31 A1. Pela classificação de Tronzo, a tipo III foi a mais comum. A fratura foi fixada com haste cefalomedular em 64 casos e com placa-parafuso deslizante em 44 casos. Uma fratura foi fixada com placa-parafuso 95◦ . Sete pacientes apresentaram alguma complicação clínica e três foram a óbito durante o internamento. Todos os pacientes que receberam alta foram orientados a fazer apoio parcial. CONCLUSÃO: por meio do Sinpe(c) foi possível avaliar as informações relacionadas a dados pessoais, anamnese, classificação, tratamento e alta de pacientes com fratura transtrocantérica desde a admissão até a alta hospitalar...


Subject(s)
Humans , Male , Female , Young Adult , Middle Aged , Aged, 80 and over , Hip Fractures/epidemiology , Hip Fractures/etiology , Retrospective Studies , Data Collection
16.
Rev. bras. ortop ; 49(1): 62-68, Jan-Feb/2014. tab, graf
Article in Portuguese | LILACS | ID: lil-707174

ABSTRACT

Objetivo: analisar os efeitos do ácido hialurônico de diferentes pesos moleculares em modelo experimental de osteoartrose em coelhos. Métodos: foram alojados de modo aleatório 44 coelhos da raça California, machos, em três grupos (PR, S e P) e submetidos a ressecção do ligamento cruzado anterior do joelho direito. Decorridas três semanas do procedimento cirúrgico iniciaram-se as três injeções intra-articulares semanais de ácido hialurônico nativo (Polireumin®)-PR, ácido hialurônico de cadeia ramificada (Synvisc®)-S e soro fisiológico 0,9%-P. Todos os animais foram sacrificados após 12 semanas do ato cirúrgico e os platôs tibiais dos joelhos infiltrados foram dissecados. Cortes histológicos da cartilagem das áreas de apoio com maior espessura dos platôs tibiais foram corados com Alcian Blue pH = 1,0, Alcian Blue pH = 2,5 e Azul de Toluidina para pesquisa da quantidade de proteoglicanos. A intensidade de coloração foi quantificada em um aparelho de microscopia ZeissImager Z2 Metasystems e analisada pelo software MetaferMsearch. A análise estatística consistiu no uso dos testes Kolmorov-Smirnov, análise de variância (Anova), t de Student e qui-quadrado. O nível de significância usado foi de 5%. Resultado: o efeito condroprotetor dos ácidos hialurônicos usados no estudo foi demonstrado quando comparado ao do grupo controle, porém, feita a comparação entre si, não houve diferença estatística quanto à condroproteção. Conclusão: os ácidos hialurônicos testados obtiveram efeito condroprotetor, sem diferença estatística com relação aos diferentes pesos moleculares. .


Objective: to analyze the effects of hyaluronic acid of different molecular weights in an experimental model of osteoarthritis in rabbits. Methods: forty-four male California rabbits were divided randomly into three groups and underwent resection of the anterior cruciate ligament in his right knee. After three weeks of the surgical procedure began three weekly intra-articular injections of hyaluronic acid native (Polireumin®)-PR, hyaluronic acid branched chain (Synvisc®)-S and 0.9% saline-P. All animals were sacrificed after twelve weeks of surgery and tibial plateau infiltrated the knees were dissected. Histological cartilage of the support areas of the tibial plateaus were stained with Alcian Blue pH 1.0, Alcian Blue pH = 2.5 and toluidine blue for research on the amount of proteoglycans. The intensity of staining was quantified on a Zeiss microscope apparatus Imager Z2 MetaSystems and analyzed by software MetaferMsearch. Results: the effect of chondroprotetor hyaluronic acids used in the study was confirmed when compared to the control group, but the comparison made between them, there was no statistically significant difference regarding chondroprotetion. Conclusion: the hyaluronic acids tested had chondroprotective effect, with no statistical difference with regard to the different molecular weights. .


Subject(s)
Animals , Rabbits , Anterior Cruciate Ligament , Hyaluronic Acid , Models, Animal , Osteoarthritis
17.
Rev. bras. ortop ; 48(6): 563-566, Nov-Dec/2013. graf
Article in English | LILACS | ID: lil-703130

ABSTRACT

This case shows a rare tumor (chondromyxoid fibroma) in distal fibula in a pediatric patient who presented with local pain and tumescence. A final diagnosis was made only after the second operation, wherein the pathology was compared with CT imaging method and use of adjuvants.


Este caso retrata um raro tumor (fibroma condromixoide) em fíbula distal em paciente pediátrico, que se apresentava com dor e edema local. O diagnóstico final só foi feito após a segunda intervenção cirúrgica, em que o anatomopatológico foi comparado com as imagens tomográficas e o uso de métodos adjuvantes. .


Subject(s)
Humans , Male , Adolescent , Fibroma , Fibula , Neoplasms
18.
Rev. bras. ortop ; 48(5): 417-420, Sept-Oct/2013. tab, graf
Article in English | LILACS | ID: lil-697312

ABSTRACT

OBJECTIVE: To study the anatomy of the hamstring tendons insertion and anatomical rela-tionships. METHODS: Ten cadaver knees with medial and anterior intact structures were selected. The dissection was performed from anteromedial access to exposure of the insertion of the flexor tendons (FT), tibial plateau (TP) and tibial tuberosity (TT). A needle of 40 × 12 and a caliper were used to measure the distance of the tibial plateau of the knee flexor tendons insertion at 15 mm from the medial border of the patellar tendon and tibial tuberosity to the insertion of the flexor tendons of the knee. The angle between tibial plateau and the insertion of the flexor tendons of the knee (A-TP-FT) was calculated using Image Pro Plus software. RESULTS: The mean distance TP-FT was 41 ± 4.6 mm. The distance between the TT-FT was 6.88 ± 1 mm. The (A-TP-FT) was 20.3 ± 4.9°. CONCLUSION: In the anterior tibial flexor tendons are about 40 mm from the plateau with an average of 20°. .


OBJETIVO: Determinar parâmetros anatômicos para localizar a inserção dos tendões flexores do joelho na tíbia. MÉTODOS: Foram selecionados 10 joelhos de cadáveres com estruturas mediais e anteriores íntegras. A dissecção foi feita por acesso ânteromedial até a exposição adequada da inserção dos tendões flexores (TF), do planalto tibial (PT) e da tuberosidade anterior da tíbia (TAT). Uma agulha 40×12 e um paquímetro digital foram usados para aferir a distância do planalto tibial da inserção dos tendões flexores do joelho a 15 mm da borda medial ao tendão patelar e da tuberosidade anterior da tíbia à inserção dos tendões flexores do joelho. O ângulo o planalto tibial e a inserção dos tendões flexores do joelho (PT-TF) foi calculado com o auxílio do software ImagePro Plus(r). RESULTADOS: A distância PT-TF foi de 41 ± 4,6 mm em média. A distância entre a TAT-TF foi de 6,88 ± 1 mm. A angulação (PT-TF) foi de 20,3 ± 4,9 graus. CONCLUSÃO: Na região anterior da tíbia os tendões flexores estão a cerca de 40 mm do planalto com um ângulo médio de 20 graus. .


Subject(s)
Humans , Anatomy , Cadaver , Knee/anatomy & histology
19.
Rev. bras. ortop ; 48(5): 402-405, Sept-Oct/2013. tab, graf
Article in English | LILACS | ID: lil-697320

ABSTRACT

OBJECTIVE: To study the anatomy of the oblique popliteal ligament, as regards its dimensions, expansion and anatomical relationships. METHODS: Eleven cadaver knees were dissected in order to study the anatomy and take mea-surements of anatomical structures and relationships of the oblique popliteal ligament. The dissection was for posterior access to the proper exposure of the oblique popliteal ligament, the semimembranosus muscle and its expansions. For measurement of dimensions, 40 × 12 needles were used for marking the specific points and a caliper. The angles were calculated using the software ImagePro Plus(r) . RESULTS: The distance from the origin of the oblique popliteal ligament to the tibial plateau was 7.4 mm, the thickness at its origin was 7.3 mm, length was 33.6 mm and the tibial plateau angle 34.8°. The length of the expansion of the proximal oblique popliteal ligament was 39.2 mm, thickness 7.8 mm and angle of the oblique popliteal ligament with its expansion 32.2°. CONCLUSION: The oblique popliteal ligament is thick, rises in the semimembranosus and protrudes proximally forming an acute angle with the joint interline, crossing the popliteal fossa. In some cases it has a proximal expansion. .


OBJETIVO: Estudar a anatomia do ligamento poplíteo oblíquo no que se refere às suas dimensões, expansões e relações anatômicas. MÉTODOS: Onze joelhos de cadáveres foram dissecados com o intuito de se estudar a anatomia e fazer medições das estruturas e das relações anatômicas do ligamento poplíteo oblíquo. A dissecção foi por acesso posterior até a exposição adequada do ligamento poplíteo oblíquo, do músculo semimembranoso e de suas expansões. Para aferição das medidas, foram usados agulhas 40x12 na marcação dos pontos específicos e um paquímetro. Os ângulos foram calculados com o auxílio do software ImagePro Plus(r). RESULTADOS: A distância da origem do ligamento poplíteo oblíquo ao platô tibial foi de 7,4 mm, a espessura na sua origem foi de 7,3 mm, o comprimento foi de 33,6 mm e o ângulo com o platô tibial foi de 34,8°. O comprimento da expansão proximal do ligamento poplíteo oblíquo foi de 39,2 mm, a espessura foi de 7,8 mm e o ângulo do ligamento poplíteo oblíquo com sua expansão foi de 32,2°. CONCLUSÃO: O ligamento poplíteo oblíquo é espesso, nasce no músculo semimembranoso, projeta-se proximalmente, forma um ângulo agudo com a interlinha articular e cruza a fossa poplítea. Em alguns casos apresenta uma expansão proximal. .


Subject(s)
Anatomy , Cadaver , Knee
20.
Rev. bras. ortop ; 48(1): 80-86, Jan-Feb/2013. tab, graf
Article in English | LILACS | ID: lil-674585

ABSTRACT

OBJETIVO: Avaliar e comparar o comportamento biomecânico de duas diferentes configurações de sutura, em "X" e em "Laçada", no preparo dos tendões para reconstrução ligamentar no joelho. MÉTODOS: Usaram-se tendões extensores digitais comuns bovinos que podem substituir os tendões flexores humanos em estudos experimentais de tração. No primeiro grupo, ponto em "X", a sutura com fio Ethibond(r) nº 5 iniciou-se na porção distal do enxerto, com pontos transfixantes e com espaçamento entre os pontos de 7,5 mm até alcançar 3 cm distal ao início da sutura, retornando a sutura da mesma maneira, transfixando o tendão nos espaços livres e cruzando a sutura em configuração de "X". O segundo grupo, ponto em "Laçada", foi preparado com o mesmo tipo de fio Ethibond(r) nº 5, a agulha do fio foi retirada para uso somente do fio, que foi montado de maneira dupla em uma agulha avulsa formando um laço. Iniciou-se a sutura a 3 cm da extremidade do enxerto por meio de laçadas e pontos transfixantes em toda a substância do tendão, com espaçamento entre os pontos de 7,5 mm.


Subject(s)
Animals , Anterior Cruciate Ligament , Biomechanical Phenomena , Cattle , Suture Techniques , Transplantation
SELECTION OF CITATIONS