1.
J Pers Med ; 13(7)2023 Jun 26.
Article in English | MEDLINE | ID: mdl-37511659

ABSTRACT

Due to the high heterogeneity in outcome measures after total hip arthroplasty (THA), the prospective observational study investigated the relationships between symmetry-based (SBMs), performance-based (PBMs), and functional outcome measures in THA patients to determine necessary or redundant categories of tests. The study material consisted of 24 patients with end-stage hip osteoarthritis scheduled for THA. The patients were examined one day before surgery and consecutively on the 4th day, 9th day, and 10th week postoperatively using the SBMs (weight-bearing chair-rising test, measurements of the maximal isometric torque of the quadriceps muscle); the PBMs (10-m walk, timed up-and-go, and stair-climbing tests); and the functional outcome measure (Harris Hip Score). The results obtained in a given category of tests at different time points were compared, and the correlations between the tests were determined. The reliability of the outcome measures was determined. The results of tests in the studied categories statistically significantly (p < 0.05) improved at the 10th week postoperatively compared to preoperative results. No strong correlations were revealed between the three studied types of outcome measures in THA patients. Therefore, none of them can be considered redundant. It also means that the relevance of symmetry for a core measurement set to describe the domain function in THA patients must be further clarified.

2.
J Clin Med ; 12(2)2023 Jan 11.
Article in English | MEDLINE | ID: mdl-36675531

ABSTRACT

The number of blood flow restriction (BFR) training practitioners is rapidly increasing, so understanding the safety issues associated with limb occlusion is strongly needed. The present study determined the effect of BFR by an inflatable cuff worn around the arm on the wrist joint position sense (JPS) in healthy recreational athletes. In the prospective randomized, double-blind placebo control study, sixty healthy right-handed recreational athletes aged x = 22.93 ± 1.26 years were assigned to groups of equal size and gender rates: BFR, placebo, and control. The active wrist JPS was assessed in two separate sessions using an isokinetic dynamometer. The first assessment was performed with no cuffs. In the second session, a cuff with a standardized pressure was worn on the examined limb in the BFR group. In the placebo group, the cuff was uninflated. A between-session comparison in each group of collected angular errors expressed in degrees was carried out. The angular error in the BFR group was larger during the second measurement than the first one (p = 0.011-0.336). On the contrary, in the placebo (p = 0.241-0.948) and control (p = 0.093-0.904) groups, the error value in the second session was comparable or smaller. It was determined that BFR by an inflatable cuff around the arm impairs the wrist position sense. Hence, BFR training should be performed with caution.

3.
Biology (Basel) ; 11(4)2022 Apr 11.
Article in English | MEDLINE | ID: mdl-35453777

ABSTRACT

The Athletic Shoulder (ASH) test was introduced as a tool for quantifying the ability to produce and transfer force across the shoulder girdle. Whether using the portable isometric-based strength training device Active5™ is a reliable alternative to a gold standard force plate for ASH testing purposes remains unknown; therefore, the present study determined the reliability and validity of Active5™ usage in the ASH test compared to force plates. Fifty-one healthy participants performed the ASH test using Active5™ and K-Force plates in three separate sessions. The maximal force was measured bilaterally in a prone position at three shoulder abduction angles, precisely at 180°, 135°, and 90°. The first rater carried out the first and third sessions, spaced at a one-week interval. A second rater performed the second session. The reliability was assessed using the intraclass correlation coefficient (ICC). The linear Pearson's correlation coefficient (r) calculation was used to determine the relationship between ASH test results using the two devices. The ICC = 0.77-0.99 result indicated good to excellent reliability for Active5™ usage. A high to a very high correlation between the two devices at 180° and 90° was noted (r = 0.75-0.95). This data supports the isometric-based strength training device Active5™ as a reliable and valid tool for ASH test performance.