Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Micromachines (Basel) ; 15(7)2024 Jun 30.
Article in English | MEDLINE | ID: mdl-39064384

ABSTRACT

Laser-inscribed graphene (LIG) is an emerging material for micro-electronic applications and is being used to develop supercapacitors, soft actuators, triboelectric generators, and sensors. The fabrication technique is simple, yet the batch-to-batch variation of LIG quality is not well documented in the literature. In this study, we conduct experiments to characterize batch-to-batch variation in the manufacturing of LIG electrodes for applications in electrochemical sensing. Numerous batches of 36 LIG electrodes were synthesized using a CO2 laser system on polyimide film. The LIG material was characterized using goniometry, stereomicroscopy, open circuit potentiometry, and cyclic voltammetry. Hydrophobicity and electrochemical screening (cyclic voltammetry) indicate that LIG electrode batch-to-batch variation is less than 5% when using a commercial reference and counter electrode. Metallization of LIG led to a significant increase in peak current and specific capacitance (area between anodic/cathodic curve). However, batch-to-batch variation increased to approximately 30%. Two different platinum electrodeposition techniques were studied, including galvanostatic and frequency-modulated electrodeposition. The study shows that formation of metallized LIG electrodes with high specific capacitance and peak current may come at the expense of high batch variability. This design tradeoff has not been discussed in the literature and is an important consideration if scaling sensor designs for mass use is desired. This study provides important insight into the variation of LIG material properties for scalable development of LIG sensors. Additional studies are needed to understand the underlying mechanism(s) of this variability so that strategies to improve the repeatability may be developed for improving quality control. The dataset from this study is available via an open access repository.

2.
Annu Rev Anal Chem (Palo Alto Calif) ; 16(1): 285-309, 2023 06 14.
Article in English | MEDLINE | ID: mdl-37018797

ABSTRACT

The goal of protecting the health of future generations is a blueprint for future biosensor design. Systems-level decision support requires that biosensors provide meaningful service to society. In this review, we summarize recent developments in cyber physical systems and biosensors connected with decision support. We identify key processes and practices that may guide the establishment of connections between user needs and biosensor engineering using an informatics approach. We call for data science and decision science to be formally connected with sensor science for understanding system complexity and realizing the ambition of biosensors-as-a-service. This review calls for a focus on quality of service early in the design process as a means to improve the meaningful value of a given biosensor. We close by noting that technology development, including biosensors and decision support systems, is a cautionary tale. The economics of scale govern the success, or failure, of any biosensor system.


Subject(s)
Aspirations, Psychological , Data Science , Engineering , Physical Examination
3.
Biosens Bioelectron ; 178: 113011, 2021 Apr 15.
Article in English | MEDLINE | ID: mdl-33517232

ABSTRACT

We review the challenges and opportunities for biosensor research in North America aimed to accelerate translational research. We call for platform approaches based on: i) tools that can support interoperability between food, environment and agriculture, ii) open-source tools for analytics, iii) algorithms used for data and information arbitrage, and iv) use-inspired sensor design. We summarize select mobile devices and phone-based biosensors that couple analytical systems with biosensors for improving decision support. Over 100 biosensors developed by labs in North America were analyzed, including lab-based and portable devices. The results of this literature review show that nearly one quarter of the manuscripts focused on fundamental platform development or material characterization. Among the biosensors analyzed for food (post-harvest) or environmental applications, most devices were based on optical transduction (whether a lab assay or portable device). Most biosensors for agricultural applications were based on electrochemical transduction and few utilized a mobile platform. Presently, the FEAST of biosensors has produced a wealth of opportunity but faces a famine of actionable information without a platform for analytics.


Subject(s)
Agriculture , Biosensing Techniques , Biological Assay , North America
SELECTION OF CITATIONS
SEARCH DETAIL