IEEE Open J Eng Med Biol ; 5: 498-504, 2024.
Article in English | MEDLINE | ID: mdl-39050973

ABSTRACT

Goal: To develop and validatea novel neonatal non-invasive respiratory support device prototype designed to operate in low-resource settings. Methods: The device integrates a blower-based ventilator and a portable oxygen concentrator. A novel control algorithm was designed to achieve the desired fraction of inspired oxygen (FiO2) while minimizing power consumption. The accuracy of the delivered FiO2 and the device power consumption were evaluated in vitro, and a formative usability test was conducted in a rural hospital in Uganda. Results: The agreement between the set and delivered FiO2 was high (limit of agreement:-5.6 ÷ 3.8%). For FiO2 below 60%, the control algorithm reduced the power drain by 50%. The device was also appreciated by intended users. Conclusion: The prototype proved effective in delivering oxygen-enriched continuous positive airway pressure in the absence of compressed air and oxygen, holding promise for a sustainable and effective implementation of neonatal respiratory support in low-resource settings.

2.
Eur Respir J ; 2024 Jul 26.
Article in English | MEDLINE | ID: mdl-39060013

ABSTRACT

OBJECTIVE: This multicenter, international, retrospective study aims to investigate whether respiratory system reactance (Xrs) assessed by respiratory oscillometry on the 7th day of life is associated with respiratory outcomes in preterm infants below 32 weeks' gestation. METHODS: Sinusoidal pressure oscillations (2-5 cmH2O peak-to-peak, 10 Hz) were superimposed on the positive end-expiratory pressure (PEEP). We assessed the association of Xrs z-score with the duration of respiratory support using linear regression and with bronchopulmonary dysplasia (BPD, according to Jensen et al. 2019) using logistic regression. We used the likelihood ratio test to evaluate whether Xrs z-score adds significantly to clinical predictors, including gestational age (GA), birth weight (BW) and the National Institute of Child Health and Human Development (NICHD) BPD prediction model. RESULTS: One hundred and thirty-seven infants (median (Q1, Q3) GA=28.43 (26.11, 30.29) weeks) were included; 44 (32%) developed BPD. Xrs z-score was significantly associated with the duration of respiratory support (R2=0.35). Xrs z-score was significantly higher in infants who developed BPD (p<0.001); the optimal cut-off value was 2.6, associated with 77% sensitivity and 80% specificity. In univariable analysis, per z-score increase in Xrs, the OR for BPD increased by 60% and the respiratory support by eight days. In multivariable analysis, Xrs z-score added significantly to the NICHD model and to GA and BW z-score to predict respiratory support duration (p=0.016 and p=0.014, respectively) and BPD development (p=0.003 and p<0.001, respectively). CONCLUSION: Xrs z-score on the 7th day after birth improves the prediction of respiratory outcome in preterm infants.

3.
Arch Dis Child ; 109(8): 666-672, 2024 Jul 18.
Article in English | MEDLINE | ID: mdl-38789116

ABSTRACT

OBJECTIVE: We analysed the relationship between oscillatory volume (VOSC) and pressure amplitude (ΔP) in six neonatal high-frequency oscillatory (HFO) ventilators and related it to (1) the accuracy of VOSC and ΔP measurements and (2) the maximal delivered ΔP. DESIGN: In vitro study. SETTING: Neonatal intensive care unit. INTERVENTIONS: Ventilators tested were VN800 (Dräger), Servo-n (Maquet Getinge), SensorMedics 3100A (Vyaire Medical), Fabian HFOi (Vyaire Medical), SLE6000 (SLE UK) and Humming Vue (Metran). We changed various settings and mechanical characteristics of the test lung to mimic preterm and term conditions. MAIN OUTCOME MEASURES: For each condition, we measured VOSC and ΔP. We assessed the accuracy of the VOSC and ΔP measurements versus a reference measurement system using linear regression and Bland-Altman analysis. We evaluated the maximum delivered ΔP at different oscillatory frequencies. RESULTS: We observed large variability between machines in the ΔP displayed at any target VOSC. Most ventilators over-read ΔP with errors up to 30 cmH2O or 60%. The error in the measurement of VOSC was up to ±2 mL or ±30%. We observed high variability in the accuracy of ΔP and VOSC measurements; the SLE6000 committed the lowest errors in ΔP measurements and the Fabian HFOi in VOSC. The maximum delivered ΔP varied depending on the ventilator, being maximal for the Humming Vue, followed by the SLE6000 and SensorMedics 3100A. CONCLUSIONS: The variability in the relationship between VOSC and ΔP among HFO ventilators is largely explained by the variable accuracy in ΔP and VOSC measurement. Different ventilators also exhibit important differences in the maximal generated ΔP.


Subject(s)
High-Frequency Ventilation , Ventilators, Mechanical , Humans , High-Frequency Ventilation/instrumentation , High-Frequency Ventilation/methods , Infant, Newborn , Ventilators, Mechanical/standards , Intensive Care Units, Neonatal , Infant, Premature/physiology , Equipment Design , Pressure
4.
Am J Physiol Lung Cell Mol Physiol ; 327(2): L203-L217, 2024 Aug 01.
Article in English | MEDLINE | ID: mdl-38771135

ABSTRACT

This study investigated the relationship between three respiratory support approaches on lung volume recruitment during the first 2 h of postnatal life in preterm lambs. We estimated changes in lung aeration, measuring respiratory resistance and reactance by oscillometry at 5 Hz. We also measured intratracheal pressure in subsets of lambs. The first main finding is that sustained inflation (SI) applied noninvasively (Mask SI; n = 7) or invasively [endotracheal tube (ETT) SI; n = 6] led to similar rapid lung volume recruitment (∼6 min). In contrast, Mask continuous positive airway pressure (CPAP) without SI (n = 6) resuscitation took longer (∼30-45 min) to reach similar lung volume recruitment. The second main finding is that, in the first 15 min of postnatal life, the Mask CPAP without SI group closed their larynx during custom ventilator-driven expiration, leading to intratracheal positive end-expiratory pressure of ∼17 cmH2O (instead of 8 cmH2O provided by the ventilator). In contrast, the Mask SI group used the larynx to limit inspiratory pressure to ∼26 cmH2O (instead of 30 cmH2O provided by the ventilator). These different responses affected tidal volume, being larger in the Mask CPAP without SI group [8.4 mL/kg; 6.7-9.3 interquartile range (IQR)] compared to the Mask SI (5.0 mL/kg; 4.4-5.2 IQR) and ETT SI groups (3.3 mL/kg; 2.6-3.7 IQR). Distinct physiological responses suggest that spontaneous respiratory activity of the larynx of preterm lambs at birth can uncouple pressure applied by the ventilator to that applied to the lung, leading to unpredictable lung pressure and tidal volume delivery independently from the ventilator settings.NEW & NOTEWORTHY We compared invasive and noninvasive resuscitation on lambs at birth, including or not sustained inflation (SI). Lung volume recruitment was faster in those receiving SI. During noninvasive resuscitation, larynx modulation reduced tracheal pressure from that applied to the mask in lambs receiving SI, while it led to increased auto-positive end-expiratory pressure and very large tidal volumes in lambs not receiving SI. Our results highlight the need for individualizing pressures and monitoring tidal volumes during resuscitation at birth.


Subject(s)
Animals, Newborn , Lung , Tidal Volume , Trachea , Animals , Tidal Volume/physiology , Sheep , Lung/physiology , Trachea/physiology , Respiratory Mechanics/physiology , Continuous Positive Airway Pressure/methods , Resuscitation/methods , Intubation, Intratracheal/methods , Pressure , Positive-Pressure Respiration/methods
5.
J Clin Med ; 13(7)2024 Mar 24.
Article in English | MEDLINE | ID: mdl-38610633

ABSTRACT

Background: Oscillometry allows for the non-invasive measurements of lung mechanics. In COVID-19 ARDS patients treated with Non-Invasive Oxygen Support (NI-OS), we aimed to (1) observe lung mechanics at the patients' admission and their subsequent changes, (2) compare lung mechanics with clinical and imaging data, and (3) evaluate whether lung mechanics helps to predict clinical outcomes. Methods: We retrospectively analyzed the data from 37 consecutive patients with moderate-severe COVID-19 ARDS. Oscillometry was performed on their 1st, 4th, and 7th day of hospitalization. Resistance (R5), reactance (X5), within-breath reactance changes (ΔX5), and the frequency dependence of the resistance (R5-R19) were considered. Twenty-seven patients underwent computed tomographic pulmonary angiography (CTPA): collapsed, poorly aerated, and normally inflated areas were quantified. Adverse outcomes were defined as intubation or death. Results: Thirty-two patients were included in this study. At the first measurement, only 44% of them had an abnormal R5 or X5. In total, 23 patients had measurements performed on their 3rd day and 7 on their 7th day of hospitalization. In general, their R5, R5-R19, and ΔX decreased with time, while their X5 increased. Collapsed areas on the CTPA correlated with the X5 z-score (ρ = -0.38; p = 0.046), while poorly aerated areas did not. Seven patients had adverse outcomes but did not present different oscillometry parameters on their 1st day of hospitalization. Conclusions: Our study confirms the feasibility of oscillometry in critically ill patients with COVID-19 pneumonia undergoing NI-OS. The X5 z-scores indicates collapsed but not poorly aerated lung areas in COVID-19 pneumonia. Our data, which show a severe impairment of gas exchange despite normal reactance in most patients with COVID-19 ARDS, support the hypothesis of a composite COVID-19 ARDS physiopathology.

6.
J Appl Physiol (1985) ; 136(6): 1499-1506, 2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38634505

ABSTRACT

Data on static compliance of the chest wall (Ccw) in preterm infants are scarce. We characterized the static compliance of the lung (CL) and Ccw to determine their relative contribution to static compliance of the respiratory system (Crs) in very preterm infants at 36 wk postmenstrual age (PMA). We also aimed to investigate how these compliances were influenced by the presence of bronchopulmonary dysplasia (BPD) and impacted breathing variables. Airway opening pressure, esophageal pressure, and tidal volume (VT) were measured simultaneously during a short apnea evoked by the Hering-Breuer reflex. We computed tidal breathing variables, airway resistance (R), and dynamic lung compliance (CL,dyn), inspiratory capacity (IC), and Crs, CL, and Ccw. Functional residual capacity was assessed by the multiple breath washout technique (FRCmbw). Breathing variables, compliances, and lung volumes were adjusted for body weight. Twenty-three preterm infants born at 27.2 ± 2.0 wk gestational age (GA) were studied at 36.6 ± 0.6 wk PMA. Median and interquartile range (IQR) Crs/kg is 0.69 (0.6), CL/kg 0.95 (1.0), and Ccw/kg 3.0 (2.4). Infants with BPD (n = 11) had lower Crs/kg (P = 0.013), CL/kg (P = 0.019), and Ccw/kg (P = 0.027) compared with infants without BPD. Ccw/CL ratio was equal between groups. FRCmbw/kg (P = 0.044) and IC/kg (P = 0.005) were decreased in infants with BPD. Infants with BPD have reduced static compliance of the respiratory system, the lungs, and chest wall. Decreased Crs, CL, and Ccw in infants with BPD explain the lower FRC and IC seen in these infants.NEW & NOTEWORTHY Data on chest wall compliance in very preterm infants in the postsurfactant era are scarce. To our knowledge, we are the first group to report data on static respiratory system compliance (Crs), lung compliance (CL), and chest wall compliance (Ccw) in preterm infants with and without bronchopulmonary dysplasia (BPD) in the postsurfactant era.


Subject(s)
Bronchopulmonary Dysplasia , Infant, Premature , Lung , Respiratory Mechanics , Thoracic Wall , Humans , Thoracic Wall/physiopathology , Thoracic Wall/physiology , Infant, Newborn , Male , Female , Respiratory Mechanics/physiology , Bronchopulmonary Dysplasia/physiopathology , Lung Compliance/physiology , Infant, Premature/physiology , Lung/physiopathology , Tidal Volume/physiology , Airway Resistance/physiology , Infant, Extremely Premature/physiology , Gestational Age , Functional Residual Capacity/physiology
7.
Am J Physiol Lung Cell Mol Physiol ; 326(6): L770-L785, 2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38563994

ABSTRACT

Novel therapies are needed for bronchopulmonary dysplasia (BPD) because no effective treatment exists. Mesenchymal stromal cell extracellular vesicles (MSC-sEVs) have therapeutic efficacy in a mouse pup neonatal hyperoxia BPD model. We tested the hypothesis that MSC-sEVs will improve lung functional and structural development in mechanically ventilated preterm lambs. Preterm lambs (∼129 days; equivalent to human lung development at ∼28 wk gestation) were exposed to antenatal steroids, surfactant, caffeine, and supported by mechanical ventilation for 6-7 days. Lambs were randomized to blinded treatment with either MSC-sEVs (human bone marrow MSC-derived; 2 × 1011 particles iv; n = 8; 4 F/4 M) or vehicle control (saline iv; 4 F/4 M) at 6 and 78 h post delivery. Physiological targets were pulse oximetry O2 saturation 90-94% ([Formula: see text] 60-90 mmHg), [Formula: see text] 45-60 mmHg (pH 7.25-7.35), and tidal volume 5-7 mL/kg. MSC-sEVs-treated preterm lambs tolerated enteral feedings compared with vehicle control preterm lambs. Differences in weight patterns were statistically significant. Respiratory severity score, oxygenation index, A-a gradient, distal airspace wall thickness, and smooth muscle thickness around terminal bronchioles and pulmonary arterioles were significantly lower for the MSC-sEVs group. S/F ratio, radial alveolar count, secondary septal volume density, alveolar capillary surface density, and protein abundance of VEGF-R2 were significantly higher for the MSC-sEVs group. MSC-sEVs improved respiratory system physiology and alveolar formation in mechanically ventilated preterm lambs. MSC-sEVs may be an effective and safe therapy for appropriate functional and structural development of the lung in preterm infants who require mechanical ventilation and are at risk of developing BPD.NEW & NOTEWORTHY This study focused on potential treatment of preterm infants at risk of developing bronchopulmonary dysplasia (BPD), for which no effective treatment exists. We tested treatment of mechanically ventilated preterm lambs with human mesenchymal stromal cell extracellular vesicles (MSC-sEVs). The results show improved respiratory gas exchange and parenchymal growth of capillaries and epithelium that are necessary for alveolar formation. Our study provides new mechanistic insight into potential efficacy of MSC-sEVs for preterm infants at risk of developing BPD.


Subject(s)
Animals, Newborn , Bronchopulmonary Dysplasia , Extracellular Vesicles , Lung , Mesenchymal Stem Cells , Respiration, Artificial , Animals , Extracellular Vesicles/metabolism , Extracellular Vesicles/transplantation , Mesenchymal Stem Cells/metabolism , Lung/metabolism , Lung/pathology , Respiration, Artificial/adverse effects , Respiration, Artificial/methods , Sheep , Bronchopulmonary Dysplasia/pathology , Bronchopulmonary Dysplasia/therapy , Bronchopulmonary Dysplasia/metabolism , Humans , Female
8.
J Appl Physiol (1985) ; 136(4): 928-937, 2024 Apr 01.
Article in English | MEDLINE | ID: mdl-38420682

ABSTRACT

Abdominal inflation with CO2 is used to facilitate laparoscopic surgeries, however, providing adequate mechanical ventilation in this scenario is of major importance during anesthesia management. We characterized high-frequency percussive ventilation (HFPV) in protecting from the gas exchange and respiratory mechanical impairments during capnoperitoneum. In addition, we aimed to assess the difference between conventional pressure-controlled mechanical ventilation (CMV) and HFPV modalities generating the high-frequency signal intratracheally (HFPVi) or extrathoracally (HFPVe). Anesthetized rabbits (n = 16) were mechanically ventilated by random sequences of CMV, HFPVi, and HFPVe. The ventilator superimposed the conventional waveform with two high-frequency signals (5 Hz and 10 Hz) during intratracheal HFPV (HFPVi) and HFPV with extrathoracic application of oscillatory signals through a sealed chest cuirass (HFPVe). Lung oxygenation index ([Formula: see text]/[Formula: see text]), arterial partial pressure of carbon dioxide ([Formula: see text]), intrapulmonary shunt (Qs/Qt), and respiratory mechanics were assessed before abdominal inflation, during capnoperitoneum, and after abdominal deflation. Compared with CMV, HFPVi with additional 5-Hz oscillations during capnoperitoneum resulted in higher [Formula: see text]/[Formula: see text], lower [Formula: see text], and decreased Qs/Qt. These improvements were smaller but remained significant during HFPVi with 10 Hz and HFPVe with either 5 or 10 Hz. The ventilation modes did not protect against capnoperitoneum-induced deteriorations in respiratory tissue mechanics. These findings suggest that high-frequency oscillations combined with conventional pressure-controlled ventilation improved lung oxygenation and CO2 removal in a model of capnoperitoneum. Compared with extrathoracic pressure oscillations, intratracheal generation of oscillatory pressure bursts appeared more effective. These findings may contribute to the optimization of mechanical ventilation during laparoscopic surgery.NEW & NOTEWORTHY The present study examines an alternative and innovative mechanical ventilation modality in improving oxygen delivery, CO2 clearance, and respiratory mechanical abnormalities in a clinically relevant experimental model of capnoperitoneum. Our data reveal that high-frequency oscillations combined with conventional ventilation improve gas exchange, with intratracheal oscillations being more effective than extrathoracic oscillations in this clinically relevant translational model.


Subject(s)
Cytomegalovirus Infections , High-Frequency Ventilation , Respiratory Insufficiency , Animals , Rabbits , Carbon Dioxide , High-Frequency Ventilation/methods , Respiration, Artificial/methods , Lung
9.
Children (Basel) ; 11(2)2024 Jan 26.
Article in English | MEDLINE | ID: mdl-38397269

ABSTRACT

(1) Background: Our survey aimed to gather information on respiratory care in Neonatal Intensive Care Units (NICUs) in the European and Mediterranean region. (2) Methods: Cross-sectional electronic survey. An 89-item questionnaire focusing on the current modes, devices, and strategies employed in neonatal units in the domain of respiratory care was sent to directors/heads of 528 NICUs. The adherence to the "European consensus guidelines on the management of respiratory distress syndrome" was assessed for comparison. (3) Results: The response rate was 75% (397/528 units). In most Delivery Rooms (DRs), full resuscitation is given from 22 to 23 weeks gestational age. A T-piece device with facial masks or short binasal prongs are commonly used for respiratory stabilization. Initial FiO2 is set as per guidelines. Most units use heated humidified gases to prevent heat loss. SpO2 and ECG monitoring are largely performed. Surfactant in the DR is preferentially given through Intubation-Surfactant-Extubation (INSURE) or Less-Invasive-Surfactant-Administration (LISA) techniques. DR caffeine is widespread. In the NICUs, most of the non-invasive modes used are nasal CPAP and nasal intermittent positive-pressure ventilation. Volume-targeted, synchronized intermittent positive-pressure ventilation is the preferred invasive mode to treat acute respiratory distress. Pulmonary recruitment maneuvers are common approaches. During NICU stay, surfactant administration is primarily guided by FiO2 and SpO2/FiO2 ratio, and it is mostly performed through LISA or INSURE. Steroids are used to facilitate extubation and prevent bronchopulmonary dysplasia. (4) Conclusions: Overall, clinical practices are in line with the 2022 European Guidelines, but there are some divergences. These data will allow stakeholders to make comparisons and to identify opportunities for improvement.

11.
Respir Res ; 25(1): 4, 2024 Jan 04.
Article in English | MEDLINE | ID: mdl-38178216

ABSTRACT

RATIONALE: Lung recruitment and continuous distending pressure (CDP) titration are critical for assuring the efficacy of high-frequency ventilation (HFOV) in preterm infants. The limitation of oxygenation (peripheral oxygen saturation, SpO2) in optimizing CDP calls for evaluating other non-invasive bedside measurements. Respiratory reactance (Xrs) at 10 Hz measured by oscillometry reflects lung volume recruitment and tissue strain. In particular, lung volume recruitment and decreased tissue strain result in increased Xrs values. OBJECTIVES: In extremely preterm infants treated with HFOV as first intention, we aimed to measure the relationship between CDP and Xrs during SpO2-driven CDP optimization. METHODS: In this prospective observational study, extremely preterm infants born before 28 weeks of gestation undergoing SpO2-guided lung recruitment maneuvers were included in the study. SpO2 and Xrs were recorded at each CDP step. The optimal CDP identified by oxygenation (CDPOpt_SpO2) was compared to the CDP providing maximal Xrs on the deflation limb of the recruitment maneuver (CDPXrs). RESULTS: We studied 40 infants (gestational age at birth = 22+ 6-27+ 5 wk; postnatal age = 1-23 days). Measurements were well tolerated and provided reliable results in 96% of cases. On average, Xrs decreased during the inflation limb and increased during the deflation limb. Xrs changes were heterogeneous among the infants for the amount of decrease with increasing CDP, the decrease at the lowest CDP of the deflation limb, and the hysteresis of the Xrs vs. CDP curve. In all but five infants, the hysteresis of the Xrs vs. CDP curve suggested effective lung recruitment. CDPOpt_SpO2 and CDPXrs were highly correlated (ρ = 0.71, p < 0.001) and not statistically different (median difference [range] = -1 [-3; 9] cmH2O). However, CDPXrs were equal to CDPOpt_SpO2 in only 6 infants, greater than CDPOpt_SpO2 in 10, and lower in 24 infants. CONCLUSIONS: The Xrs changes described provide complementary information to oxygenation. Further investigation is warranted to refine recruitment maneuvers and CPD settings in preterm infants.


Subject(s)
High-Frequency Ventilation , Infant, Extremely Premature , Humans , Infant, Newborn , Oscillometry , Lung , Lung Volume Measurements/methods , High-Frequency Ventilation/methods
12.
Arch. bronconeumol. (Ed. impr.) ; 55(10): 519-525, oct. 2019. graf, tab
Article in English | IBECS | ID: ibc-186201

ABSTRACT

Objective: Hypersensitivity pneumonitis (HP) is an interstitial lung disease caused by the inhalation of specific organic antigens or low-molecular weight substances in genetically susceptible individuals. Although small airway involvement is prominent in patients with chronic HP, conventional pulmonary function tests (PFTs) are relatively insensitive to identify it. Thus, the authors aimed to evaluate resistance (R5) and reactance (X5) values at 5Hz on inspiration, expiration, and whole breath, as well as small airway resistance (R5-19) values using a forced oscillation technique (FOT) in patients with chronic HP, and their responses after bronchodilator. In addition, R5 and X5 values according to the presence or absence of mosaic attenuation on computed tomography (CT) were compared. Methods: PFTs with plethysmography, diffusing capacity of the lungs for carbon monoxide (DLCO) and FOT measurements were performed pre-bronchodilator and post-bronchodilator. High-resolution CT was performed at the same visit, and classified according to the presence or absence of mosaic attenuation. R5 and X5 values were then compared according to the presence or absence of mosaic attenuation on CT. Results: Twenty-eight patients with chronic HP (57.1% female; mean age, 56 ± 11.5 years; mean forced vital capacity 57 ± 17% predicted) were evaluated. All patients had low X5 values, reflecting lower lung compliance, and only three (8%) demonstrated elevated R5 (whole-breath) values. No patients exhibited bronchodilator response in R5, X5 and R5-19 values. In patients who exhibited greater extension of mosaic attenuation (n = 11), R5 and X5 values could not discriminate those with a greater presence of these areas on CT. Conclusions: The results suggest that FOT does not help to additionally characterise concomitant small airway involvement in patients with chronic fibrotic HP who demonstrate restrictive ventilatory pattern in conventional PFTs. Nevertheless, FOT appeared to better characterise decreased lung compliance due to fibrosis through X5. Bronchodilator therapy did not appear to induce an acute response in chronic HP patients with restrictive disease. The precise role of FOT in subacute HP and obstructive chronic HP, therefore, must be evaluated


Objetivo: La neumonitis por hipersensibilidad (HP) es una enfermedad pulmonar intersticial causada por la inhalación de antígenos orgánicos específicos o sustancias de bajo peso molecular en individuos genéticamente susceptibles. Aunque la implicación de las vías aéreas pequeñas es típica en pacientes con HP crónica, a las pruebas habituales de función pulmonar (PFP) les falta sensibilidad para detectarla. El objetivo fue evaluar los valores de resistencia (R5) y de reactancia (X5) a 5Hz durante la inspiración, la espiración y el ciclo completo, así como los valores de resistencia de las vías aéreas pequeñas y las respuestas tras broncodilatador. Para ello se utilizó la técnica de oscilación forzada (TOF) en pacientes con HP crónica. Además, se comprobaron los valores R5 y X5, de acuerdo con la presencia o ausencia de patrones de atenuación en mosaico mediante tomografía computarizada (TC). Métodos: Se evaluaron las PFP con pletismografía, la capacidad de difusión pulmonar para el monóxido de carbono (DLCO) y la TOF antes y después de broncodilatador (pre- y posbroncodilatador, respectivamente). La TC de alta resolución se realizó en la misma visita, y los resultados se clasificaron en función de la presencia o ausencia de patrones de atenuación en mosaico. Resultados: Se evaluaron 28 pacientes con HP crónica (57,1% mujeres; edad media: 56 ± 11,5 años; capacidad vital forzada media estimada: 57 ± 17%). Todos los pacientes tuvieron valores X5 bajos, indicativo de una distensibilidad pulmonar baja, y solo 3 (8%) presentaron valores elevados de R5 (respiración completa). Ningún paciente exhibió respuesta broncodilatadora en valores R5, X5 y R5-19. Los valores de R5 y X5 no permitieron discriminar a aquellos pacientes que presentaron patrón de atenuación en mosaico extenso en la TC (n = 11). Conclusiones: Los resultados sugieren que la TOF no proporciona información extra en la caracterización de la implicación concomitante de las vías aéreas pequeñas en pacientes con HP crónica que presentan patrones ventilatorios restrictivos en PFP convencionales. Sin embargo, la TOF parece permitir una mejor caracterización de la disminución de la distensibilidad pulmonar debido a fibrosis a través del valor X5. La terapia broncodilatadora no indujo respuesta aguda en pacientes con HP crónica y enfermedad restrictiva. Por tanto, se debe evaluar el papel específico de la TOF en la HP subaguda y la HP obstructiva crónica


Subject(s)
Humans , Male , Female , Middle Aged , Aged , Alveolitis, Extrinsic Allergic/diagnosis , Respiratory Function Tests/instrumentation , Vital Capacity , Respiratory Function Tests/methods , Tomography, Emission-Computed , Plethysmography , Forced Expiratory Volume , Oscillometry