Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 10 de 10
Filter
1.
Curr Opin Cardiol ; 39(5): 417-425, 2024 Sep 01.
Article in English | MEDLINE | ID: mdl-38606620

ABSTRACT

PURPOSE OF REVIEW: The no-touch technique is an established method to harvest the saphenous vein (NT-SV), which is the most commonly used conduit in coronary artery bypass grafting. Herein, we summarize the foundational evidence, as well as highlight recent innovations and ongoing clinical trials involving NT-SV. RECENT FINDINGS: Through preservation of perivascular tissue for atraumatic handling and omission of manual distension, the NT-SV maintains endothelial nitrous oxide synthase levels and experiences less vascular smooth muscle cell activation, which translates to slower progression of atherosclerosis and less size mismatch of the graft and target vessel. These biomolecular advantages allow NT-SV to provide superior graft patency compared to conventional skeletonized saphenous vein and approximating that of the radial artery. Nonetheless, the clinical benefits of NT-SV for mortality and reduction in major adverse cardiac and cerebrovascular events are insufficiently studied in the long-term. The drawback of NT-SV is the short-term harvest site complications, which may potentially be addressed by the advent of endoscopic no-touch technique. SUMMARY: NT-SV is a promising conduit, and its role will be further clarified in upcoming clinical trials and as follow-up lengthens. However, conduit selection and harvest technique should ultimately be personalized to the individual patient.


Subject(s)
Coronary Artery Bypass , Saphenous Vein , Tissue and Organ Harvesting , Humans , Coronary Artery Bypass/methods , Tissue and Organ Harvesting/methods , Vascular Patency , Coronary Artery Disease/surgery
2.
Can J Cardiol ; 40(3): 478-495, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38052303

ABSTRACT

Aortic arch pathology is relatively rare but potentially highly fatal and associated with considerable comorbidity. Operative mortality and complication rates have improved over time but remain high. In response, aortic arch surgery is one of the most rapidly evolving areas of cardiac surgery in terms of surgical volume and improved outcomes. Moreover, there has been a surge in novel devices and techniques, many of which have been developed by or codeveloped with vascular surgeons and interventional radiologists. Nevertheless, the extent of arch surgery, the choice of nadir temperature, cannulation, and perfusion strategies, and the use of open, endovascular, or hybrid options vary according to country, centre, and surgeon. In this review article, we provide a technical overview of the surgical, total endovascular, and hybrid repair options for aortic arch pathology through historical developments and contemporary results. We highlight key information for surgeons, cardiologists, and trainees to understand the management of patients with aortic arch pathology. We conclude by discussing training paradigms, the role of aortic teams, and gaps in knowledge, arguing for the need for wire skills for the future "interventional aortic surgeon" and increased research into techniques and novel devices to continue improving outcomes for aortic arch surgery.


Subject(s)
Aortic Aneurysm, Thoracic , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Surgeons , Humans , Aorta, Thoracic/diagnostic imaging , Aorta, Thoracic/surgery , Blood Vessel Prosthesis Implantation/methods , Endovascular Procedures/methods , Comorbidity , Aortic Aneurysm, Thoracic/surgery , Treatment Outcome , Stents
3.
Asian Cardiovasc Thorac Ann ; 31(4): 382-385, 2023 May.
Article in English | MEDLINE | ID: mdl-37020336

ABSTRACT

The commonly used central shunt (i.e. direct connection of the divided main pulmonary artery to the ascending aorta) to facilitate the growth of the diminutive branch pulmonary artery in patients with pulmonary atresia with major aortopulmonary collateral arteries can cause main pulmonary artery distortion, and subsequent disproportional branch pulmonary artery flow and growth. This report describes a novel technique of shunt construction to minimize pulmonary artery torque and tension by using a modified central shunt constructed from autologous pericardium that is anastomosed in an end-to-side fashion to the lateral aspect of the ascending aorta. This shunt will serve as an intermediary conduit to facilitate the main pulmonary artery anastomosis while minimizing torque and tension on the main pulmonary artery. The tension-free connection between the main pulmonary artery and the aorta enabled by the modified central shunt supports proportional pulmonary artery flow and growth in patients with pulmonary atresia, ventricular septal defect, or multiple aortopulmonary collateral arteries and concomitant diminutive native pulmonary arteries.


Subject(s)
Heart Defects, Congenital , Heart Septal Defects, Ventricular , Pulmonary Atresia , Humans , Infant , Pulmonary Atresia/diagnostic imaging , Pulmonary Atresia/surgery , Pulmonary Artery/diagnostic imaging , Pulmonary Artery/surgery , Pulmonary Artery/abnormalities , Heart Septal Defects, Ventricular/surgery , Aorta/diagnostic imaging , Aorta/surgery , Collateral Circulation
4.
World J Pediatr Congenit Heart Surg ; 14(2): 235-238, 2023 03.
Article in English | MEDLINE | ID: mdl-36380596

ABSTRACT

While unusual, aberrant right subclavian artery (ARSCA) can occasionally be a source of significant dysphagia in children. We present a case of a 13-year-old female who reported a three-year history of dysphagia to solid foods and was found to have ARSCA on a barium swallow study and computed tomography scan of the chest. We reimplanted the ARSCA into the right carotid artery in end-to-side fashion using a partial median sternotomy approach. At six months follow-up, her symptoms had completely resolved, and her postoperative echocardiogram showed an unobstructed reimplanted ARSCA. Meeting presentation: AATS 102nd Annual Meeting; May 14, 2022; Boston, MA.


Subject(s)
Cardiovascular Abnormalities , Deglutition Disorders , Female , Child , Humans , Adolescent , Deglutition Disorders/etiology , Deglutition Disorders/surgery , Deglutition Disorders/diagnosis , Sternotomy/adverse effects , Cardiovascular Abnormalities/complications , Cardiovascular Abnormalities/diagnostic imaging , Cardiovascular Abnormalities/surgery , Subclavian Artery/diagnostic imaging , Subclavian Artery/surgery
6.
Braz J Cardiovasc Surg ; 37(Spec 1): 7-31, 2022 09 02.
Article in English | MEDLINE | ID: mdl-36053998

ABSTRACT

INTRODUCTION: The second best conduit for coronary artery bypass grafting is uncertain. The objective of this study is to determine the second best conduit according to graft patency results from randomized controlled trials using a network meta-analysis. METHODS: A systematic literature search was conducted for randomized controlled trials comparing the angiographic patency rate of the no-touch saphenous vein (NT-SV), the radial artery (RA), the right internal thoracic artery (RITA), and the gastroepiploic artery (GEA) in reference to the conventionally harvested saphenous vein (CON-SV). The primary outcome was graft occlusion, and the secondary outcome was all-cause mortality. RESULTS: A total of 859 studies were retrieved, of which 18 were included. A total of 6,543 patients and 8,272 grafts were analyzed. The weighted mean angiographic follow-up time was 3.5 years. Compared with CON-SV, RA (incidence rate ratio [IRR] 0.56; 95% confidence interval [CI], 0.43-0.74) and NT-SV (IRR 0.56; 95% CI, 0.44-0.70) demonstrated lower graft occlusion. NT-SV and RA were ranked as the best conduits (rank score for NT-SV 0.88 vs. 0.87 for RA, 0.29 for GEA, 0.27 for CON-SV, and 0.20 for RITA). There was no significant difference in late mortality between different conduit types. CONCLUSION: RA and NT-SV are associated with significantly lower graft occlusion rates and are comparably ranked as the best conduit for patency.


Subject(s)
Coronary Artery Bypass , Saphenous Vein , Coronary Angiography , Coronary Artery Bypass/methods , Humans , Network Meta-Analysis , Randomized Controlled Trials as Topic , Saphenous Vein/transplantation , Treatment Outcome , Vascular Patency
7.
J Card Surg ; 37(4): 1080-1082, 2022 Apr.
Article in English | MEDLINE | ID: mdl-35083800

ABSTRACT

This case report describes the management of a large iatrogenic ventricular septal defect (VSD) created by the coring device during systemic ventricular assist device (right ventricular assist device [RVAD]) insertion in a 16-year-old patient with congenitally corrected transposition of the great arteries. The VSD was closed by a bovine pericardial patch and the ventriculotomy was extended laterally to relocate the VAD sewing ring. After RVAD implantation, the patient initially remained cyanotic, potentially due to a tiny VSD patch leak with right-to-left shunting. Hypoxia was successfully corrected by rescue nitric oxide infusion and the patient was bridged to transplant after 91 days.


Subject(s)
Heart Septal Defects, Ventricular , Heart-Assist Devices , Transposition of Great Vessels , Adolescent , Animals , Cattle , Congenitally Corrected Transposition of the Great Arteries , Heart Septal Defects, Ventricular/etiology , Heart Septal Defects, Ventricular/surgery , Heart-Assist Devices/adverse effects , Humans , Iatrogenic Disease , Transposition of Great Vessels/complications , Transposition of Great Vessels/surgery
8.
Semin Thorac Cardiovasc Surg ; 34(3): 840-841, 2022.
Article in English | MEDLINE | ID: mdl-34098117

Subject(s)
Stents , Humans
9.
Acta Anaesthesiol Scand ; 66(1): 3-16, 2022 01.
Article in English | MEDLINE | ID: mdl-34514595

ABSTRACT

BACKGROUND: Bleeding is the leading cause of maternal mortality in the world. Tranexamic acid reduces bleeding in trauma and surgery. Several systematic reviews of randomized trials have investigated tranexamic acid in the prevention of bleeding in cesarean delivery. However, the conclusions from systematic reviews are conflicting. This overview aims to summarize the evidence and explore the reasons for conflicting conclusions across the systematic reviews. METHODS: A comprehensive literature search of Medline, Embase, and Cochrane Database of Systematic Reviews was conducted from inception to April 2021. Screening, data extraction, and quality assessments were performed by two independent reviewers. A Measurement Tool to Assess Reviews 2 and the Risk of Bias Assessment Tool for Systematic Reviews were used for study appraisal. A qualitative synthesis of evidence is presented. RESULTS: In all, 14 systematic reviews were included in our analysis. Across these reviews, there were 32 relevant randomized trials. A modest reduction in blood transfusions and bleeding outcomes was found by most systematic reviews. Overall confidence in results varied from low to critically low. All of the included systematic reviews were at high risk of bias. Quality of evidence from randomized trials was uncertain. CONCLUSIONS: Systematic reviews investigating prophylactic tranexamic acid in cesarean delivery are heterogeneous in terms of methodological and reporting quality. Tranexamic acid may reduce blood transfusion and bleeding outcomes, but rigorous well-designed research is needed due to the limitations of the included studies. Data on safety and adverse effects are insufficient to draw conclusions.


Subject(s)
Antifibrinolytic Agents , Tranexamic Acid , Antifibrinolytic Agents/therapeutic use , Blood Transfusion , Female , Hemorrhage , Humans , Pregnancy , Systematic Reviews as Topic , Tranexamic Acid/therapeutic use
10.
Rev. bras. cir. cardiovasc ; 37(spe1): 7-31, 2022. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1407340

ABSTRACT

ABSTRACT Introduction: The second best conduit for coronary artery bypass grafting is uncertain. The objective of this study is to determine the second best conduit according to graft patency results from randomized controlled trials using a network meta-analysis. Methods: A systematic literature search was conducted for randomized controlled trials comparing the angiographic patency rate of the no-touch saphenous vein (NT-SV), the radial artery (RA), the right internal thoracic artery (RITA), and the gastroepiploic artery (GEA) in reference to the conventionally harvested saphenous vein (CON-SV). The primary outcome was graft occlusion, and the secondary outcome was all-cause mortality. Results: A total of 859 studies were retrieved, of which 18 were included. A total of 6,543 patients and 8,272 grafts were analyzed. The weighted mean angiographic follow-up time was 3.5 years. Compared with CON-SV, RA (incidence rate ratio [IRR] 0.56; 95% confidence interval [CI], 0.43-0.74) and NT-SV (IRR 0.56; 95% CI, 0.44-0.70) demonstrated lower graft occlusion. NT-SV and RA were ranked as the best conduits (rank score for NT-SV 0.88 vs. 0.87 for RA, 0.29 for GEA, 0.27 for CON-SV, and 0.20 for RITA). There was no significant difference in late mortality between different conduit types. Conclusion: RA and NT-SV are associated with significantly lower graft occlusion rates and are comparably ranked as the best conduit for patency.

SELECTION OF CITATIONS
SEARCH DETAIL