Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
J Biomater Appl ; 30(7): 983-94, 2016 Feb.
Article in English | MEDLINE | ID: mdl-26494611

ABSTRACT

Nucleus pulposus replacement therapy could offer a less invasive alternative to restore the function of moderately degenerated intervertebral discs than current potentially destructive surgical procedures. Numerous nucleus pulposus substitutes have already been investigated, to assess their applicability for intradiscal use. Still, the current choice of testing methods often does not lead to efficient translation into clinical application. In this paper, we present the evaluation of a novel nucleus pulposus substitute, consisting of a hydromed core and an electrospun envelope. We performed three mechanical evaluations and an in vivo pilot experiment. Initially, the swelling pressure of the implant was assessed in confined compression. Next, we incorporated the implant into mechanically damaged caprine lumbar intervertebral discs to determine biomechanical segment behaviour in bending and torsion. Subsequently, segments were serially tested in native, damaged and repaired conditions under dynamic axial compressive loading regimes in a loaded disc culture system. Finally, nucleus pulposus substitutes were implanted in a live goat spine using a transpedicular approach. In confined compression, nucleus pulposus samples as well as implants showed some load-bearing capacity, but the implant exhibited a much lower absolute pressure. In bending and torsion, we found that the nucleus pulposus substitute could partly restore the mechanical response of the disc. During dynamic axial compression in the loaded disc culture system, on the other hand, the implant was not able to recover axial compressive behaviour towards the healthy situation. Moreover, the nucleus pulposus substitutes did not remain in place in the in vivo situation but migrated out of the disc area. From these results, we conclude that implants may mimic native disc behaviour in simple mechanical tests, yet fail in other, more realistic set-ups. Therefore, we recommend that biomaterials for nucleus pulposus replacement be tested in testing modalities of increasing complexity and in their relevant anatomical surroundings, for a more reliable prediction of clinical potential.


Subject(s)
Biocompatible Materials/chemistry , Intervertebral Disc/physiology , Nucleus Pulposus/physiology , Regenerative Medicine/methods , Tissue Engineering/methods , Animals , Biomechanical Phenomena , Compressive Strength , Female , Goats , Lumbar Vertebrae/physiology , Materials Testing , Movement , Prostheses and Implants , Stress, Mechanical , Translational Research, Biomedical , Weight-Bearing
2.
Article in English | MEDLINE | ID: mdl-25485264

ABSTRACT

The loaded disk culture system is an intervertebral disk (IVD)-oriented bioreactor developed by the VU Medical Center (VUmc, Amsterdam, The Netherlands), which has the capacity of maintaining up to 12 IVDs in culture, for approximately 3 weeks after extraction. Using this system, eight goat IVDs were provided with the essential nutrients and submitted to compression tests without losing their biomechanical and physiological properties, for 22 days. Based on previous reports (Paul et al., 2012, 2013; Detiger et al., 2013), four of these IVDs were kept in physiological condition (control) and the other four were previously injected with chondroitinase ABC (CABC), in order to promote degenerative disk disease (DDD). The loading profile intercalated 16 h of activity loading with 8 h of loading recovery to express the standard circadian variations. The displacement behavior of these eight IVDs along the first 2 days of the experiment was numerically reproduced, using an IVD osmo-poro-hyper-viscoelastic and fiber-reinforced finite element (FE) model. The simulations were run on a custom FE solver (Castro et al., 2014). The analysis of the experimental results allowed concluding that the effect of the CABC injection was only significant in two of the four IVDs. The four control IVDs showed no signs of degeneration, as expected. In what concerns to the numerical simulations, the IVD FE model was able to reproduce the generic behavior of the two groups of goat IVDs (control and injected). However, some discrepancies were still noticed on the comparison between the injected IVDs and the numerical simulations, namely on the recovery periods. This may be justified by the complexity of the pathways for DDD, associated with the multiplicity of physiological responses to each direct or indirect stimulus. Nevertheless, one could conclude that ligaments, muscles, and IVD covering membranes could be added to the FE model, in order to improve its accuracy and properly describe the recovery periods.

SELECTION OF CITATIONS
SEARCH DETAIL
...