Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 51
1.
Article En | MEDLINE | ID: mdl-38499825

BACKGROUND: Cardioneuroablation has been emerging as a potential treatment alternative in appropriately selected patients with cardioinhibitory vasovagal syncope (VVS) and functional AV block (AVB). However the majority of available evidence has been derived from retrospective cohort studies performed by experienced operators. METHODS: The Cardioneuroablation for the Management of Patients with Recurrent Vasovagal Syncope and Symptomatic Bradyarrhythmias (CNA-FWRD) Registry is a multicenter prospective registry with cross-over design evaluating acute and long-term outcomes of VVS and AVB patients treated by conservative therapy and CNA. RESULTS: The study is a prospective observational registry with cross-over design for analysis of outcomes between a control group (i.e., behavioral and medical therapy only) and intervention group (Cardioneuroablation). Primary and secondary outcomes will only be assessed after enrollment in the registry. The follow-up period will be 3 years after enrollment. CONCLUSIONS: There remains a lack of prospective multicentered data for long-term outcomes comparing conservative therapy to radiofrequency CNA procedures particularly for key outcomes including recurrence of syncope, AV block, durable impact of disruption of the autonomic nervous system, and long-term complications after CNA. The CNA-FWRD registry has the potential to help fill this information gap.

2.
IEEE J Biomed Health Inform ; 28(5): 2650-2661, 2024 May.
Article En | MEDLINE | ID: mdl-38300786

Atrial fibrillation (AF) is a common cardiac arrhythmia with serious health consequences if not detected and treated early. Detecting AF using wearable devices with photoplethysmography (PPG) sensors and deep neural networks has demonstrated some success using proprietary algorithms in commercial solutions. However, to improve continuous AF detection in ambulatory settings towards a population-wide screening use case, we face several challenges, one of which is the lack of large-scale labeled training data. To address this challenge, we propose to leverage AF alarms from bedside patient monitors to label concurrent PPG signals, resulting in the largest PPG-AF dataset so far (8.5 M 30-second records from 24,100 patients) and demonstrating a practical approach to build large labeled PPG datasets. Furthermore, we recognize that the AF labels thus obtained contain errors because of false AF alarms generated from imperfect built-in algorithms from bedside monitors. Dealing with label noise with unknown distribution characteristics in this case requires advanced algorithms. We, therefore, introduce and open-source a novel loss design, the cluster membership consistency (CMC) loss, to mitigate label errors. By comparing CMC with state-of-the-art methods selected from a noisy label competition, we demonstrate its superiority in handling label noise in PPG data, resilience to poor-quality signals, and computational efficiency.


Algorithms , Atrial Fibrillation , Photoplethysmography , Signal Processing, Computer-Assisted , Humans , Photoplethysmography/methods , Atrial Fibrillation/physiopathology , Atrial Fibrillation/diagnosis , Clinical Alarms , Machine Learning , Wearable Electronic Devices
5.
Heart Rhythm ; 20(12): 1708-1717, 2023 Dec.
Article En | MEDLINE | ID: mdl-37659454

BACKGROUND: Recurrent ventricular tachycardia (VT) after prior endocardial catheter ablation(s) presents challenges in the setting of prior cardiac surgery where percutaneous epicardial access may not be feasible. OBJECTIVE: The purpose of this study was to compare the outcomes of cryothermal vs radiofrequency ablation in direct surgical epicardial access procedures. METHODS: We performed a retrospective study of consecutive surgical epicardial VT ablation cases. Surgical cases using cryothermal vs radiofrequency ablation were analyzed and outcomes were compared. RESULTS: Between 2009 and 2022, 43 patients underwent either a cryothermal (n = 17) or a radiofrequency (n = 26) hybrid epicardial ablation procedure with direct surgical access. Both groups were similarly matched for age, sex, etiology of VT, and comorbidities with a high burden of refractory VT despite previous endocardial and/or percutaneous epicardial ablation procedures. The surgical access site was lateral thoracotomy (76.5%) in the cryothermal ablation group compared with lateral thoracotomy (42.3%) and subxiphoid approach (38.5%) in the radiofrequency group, with the remainder in both groups performed via median sternotomy. The ablation time was significantly shorter in those undergoing cryothermal ablation vs radiofrequency ablation (11.54 ± 15.5 minutes vs 48.48 ± 23.6 minutes; P < .001). There were no complications in the cryothermal ablation group compared with 6 patients with complications in the radiofrequency group. Recurrent VT episodes and all-cause mortality were similar in both groups. CONCLUSION: Hybrid surgical VT ablation with cryothermal or radiofrequency energy demonstrated similar efficacy outcomes. Cryothermal ablation was more efficient and safer than radiofrequency in a surgical setting and should be considered when surgical access is required.


Catheter Ablation , Tachycardia, Ventricular , Humans , Retrospective Studies , Catheter Ablation/adverse effects , Catheter Ablation/methods , Endocardium , Pericardium/surgery , Treatment Outcome
6.
JACC Cardiovasc Imaging ; 16(10): 1348-1352, 2023 10.
Article En | MEDLINE | ID: mdl-37656118

Right ventricular perforation is a catastrophic complication of catheter-based intracardiac interventions. In this context, appreciation of 5 attachments of the right ventricle to the aortoventricular unit is essential to recognize extent of right ventricular free wall. We herein present progressive dissection and virtual and photographic endoscopic images of the hearts without distortion. Real dissection images show us how and where to avoid this complication by indicating the true muscular component of the ventricular septum. Both virtual and photographic endoscopic images, when combined with transillumination, beautifully shows the thin wall regions and trabeculations with unprecedented clarity. We believe recognition of these anatomical nuances can reduce the likelihood of right ventricular perforation.


Heart Injuries , Ventricular Septum , Humans , Heart Ventricles/diagnostic imaging , Heart Ventricles/surgery , Predictive Value of Tests , Diagnostic Imaging
7.
JACC Case Rep ; 16: 101888, 2023 Jun 21.
Article En | MEDLINE | ID: mdl-37396330

We show the virtual simulation of the fluoroscopic location of the membranous septum using preprocedural cardiac computed tomographic data sets. Recognizing the risk distance before the procedure can help individualize implantation strategy to reduce the risk of atrioventricular conduction axis damage during transcatheter aortic valve replacement. (Level of Difficulty: Advanced.).

8.
JACC Clin Electrophysiol ; 9(7 Pt 1): 936-948, 2023 07.
Article En | MEDLINE | ID: mdl-37438043

BACKGROUND: The clinical relevance and prognostic implications of ventricular parasystole are unknown. OBJECTIVES: This study sought to assess the prevalence of ventricular parasystole in patients with implantable cardioverter-defibrillators (ICDs) and ventricular parasystole's association with ventricular arrhythmias and conduction system abnormalities. METHODS: This study retrospectively evaluated patients who underwent ICD interrogation at a single center between June 1, 2019, and August 31, 2020, and reviewed all available ICD and electrocardiogram data. This study identified patients with ventricular parasystole and compared the prevalence of ventricular fibrillation (VF), ventricular tachycardia (VT), and new conduction system abnormalities in those with ≥5 years of intrinsic QRS-complex electrocardiograms to those without parasystole. RESULTS: This study included 374 patients (age 57 ± 21 years, 72% male, 45% nonischemic, 32% ischemic cardiomyopathy), of which, 104 (28%) had VT only, 39 (10%) VF only, and 10 (3%) both VT/VF. Ventricular parasystole was identified in 33 patients (9%); parasystolic foci were predominantly from the His-Purkinje system. Compared with those without parasystole, patients with parasystole had a significantly higher rate of VF (36% vs 11%; P < 0.01), but not VT (42% vs 29%; P = 0.12). Patients with parasystole, compared with those without parasystole, had a higher prevalence of new conduction abnormalities, particularly progressive intraventricular conduction delay (11 of 18 [61%] vs 12 of 83 [14%]; P < 0.01) and new right bundle branch block (4 of 18 [22%] vs 1 of 83 [1%]; P < 0.01). CONCLUSIONS: Ventricular parasystole was strongly associated with new conduction system abnormalities and VF in patients who have cardiomyopathy with ICDs, suggesting a potential link between VF and His-Purkinje damage in this patient population.


Cardiomyopathies , Parasystole , Tachycardia, Ventricular , Humans , Male , Adult , Middle Aged , Aged , Female , Ventricular Fibrillation/epidemiology , Ventricular Fibrillation/etiology , Retrospective Studies , Arrhythmias, Cardiac , Tachycardia, Ventricular/epidemiology , Cardiomyopathies/complications , Cardiomyopathies/epidemiology , Bundle-Branch Block
10.
Pacing Clin Electrophysiol ; 46(7): 717-720, 2023 07.
Article En | MEDLINE | ID: mdl-37335091

BACKGROUND: The use of left bundle branch pacing (LBBP) has dramatically increased since it was first described in 2016, but to date there are no published data on the safety of performing magnetic resonance imaging (MRI) in these patients. METHODS: Patients with LBBP who underwent MRI between January 2016 and October 2022 were retrospectively studied in our clinical center, which has a special program for imaging patients with cardiac devices. All patients underwent close cardiac monitoring throughout the MRI scans. Occurrence of arrhythmias or other adverse effects during MRI were assessed. LBBP lead parameters immediately pre- and post-MRI and at an outpatient follow-up were compared. RESULTS: Fifteen patients with LBBP underwent a total of 19 MRI sessions during the study period. Lead parameters did not significantly change after the MRI or on follow-up, which took place at a median of 91 days after the MRI. No patient developed arrhythmias during the MRI sessions, and no adverse effects such as lead dislodgement were reported. CONCLUSION: Although larger studies are necessary to verify our findings, MRI in patients with LBBP appears safe based on this initial case series.


Bundle of His , Bundle-Branch Block , Humans , Bundle-Branch Block/diagnostic imaging , Bundle-Branch Block/therapy , Bundle-Branch Block/etiology , Cardiac Pacing, Artificial/methods , Retrospective Studies , Electrocardiography/methods , Treatment Outcome
11.
Pacing Clin Electrophysiol ; 46(7): 583-591, 2023 07.
Article En | MEDLINE | ID: mdl-37221975

BACKGROUND: Bradyarrhythmias including sinus node dysfunction (SND) and atrioventricular block (AVB) can necessitate pacemaker (PPM) implantation in orthotopic heart transplant (OHT) recipients. Prior studies have shown conflicting findings regarding the effect of PPM implantation on survival. We evaluated the effect of PPM indication on long-term re-transplant-free survival in OHT patients. METHODS: We conducted a retrospective cohort study of OHT patients at UCLA Medical Center from 1985 to 2018. Indication for PPM (SND, AVB) was identified. Cox proportional hazards model with pacemaker implantation as a time-varying covariate was used to evaluate its effect on the primary endpoint of retransplant or death. We included 1609 OHTs in 1511 adult patients with median follow-up of 12 years. RESULTS: At transplant, patients were aged 53 ± 13 years and 1125 (74.5%) were male. Pacemakers were implanted in 109 (7.2%) patients; 65 for SND (4.3%) and 43 for AVB (2.8%). Repeat OHT was performed in 103 (6.4%) cases and 798 (52.8%) patients died during the follow-up period. The risk of the primary endpoint was significantly higher in patients requiring PPM for AVB (HR 3.0, 95% CI 2.1-4.2, p < .01) after controlling for age at OHT, gender, hypertension, diabetes, renal disease, history of repeat OHT, acute rejection, transplant coronary vasculopathy, and atrial fibrillation, but not PPM for SND (HR 1.0, 95% CI 0.70-1.4, p = 1.0). CONCLUSIONS: Patients who required PPM for AVB, but not SND, were at significantly higher risk of death or retransplant compared to patients who did not require PPM.


Atrial Fibrillation , Atrioventricular Block , Heart Transplantation , Pacemaker, Artificial , Adult , Humans , Male , Female , Retrospective Studies , Risk Factors , Heart Transplantation/adverse effects , Atrioventricular Block/therapy , Atrioventricular Block/etiology , Atrial Fibrillation/etiology , Sick Sinus Syndrome/therapy
13.
JACC Case Rep ; 8: 101728, 2023 Feb 15.
Article En | MEDLINE | ID: mdl-36860567

We describe the case of a 92-year-old male patient presenting with shortness of breath and an electrocardiogram showing bradycardia with irregular rhythm and varying QRS morphology. A differential diagnosis is discussed. (Level of Difficulty: Advanced.).

14.
J Interv Card Electrophysiol ; 66(5): 1253-1263, 2023 Aug.
Article En | MEDLINE | ID: mdl-36510109

BACKGROUND: Positron emission tomography computed tomography (PET-CT) is not routinely used for premature ventricular complexes (PVCs). Whether specific clinical factors are associated with abnormal PET-CT results is not clear. METHODS: The treatment courses and baseline characteristics of consecutive patients in a single center between 2012 and 2021, age > 18 years old, and who received 18F-fluorodeoxyglucose (FDG) PET-CT imaging for evaluation of PVCs were retrospectively analyzed. RESULTS: A total of 102 patients was included. Of these, 27 patients (26.4%) had abnormal PET-CT and 61 (59.8%) had normal imaging. Abnormal PET-CT findings were associated with non-sustained ventricular tachycardia (NSVT) (95.2% vs. 52.6%, p = 0.001), higher number of PVC morphologies (2.29 ± 0.7 vs. 1.31 ± 0.6, p < 0.001), greater PVC coupling interval dispersion (72.47 ± 66.4 ms vs. 13.42 ± 17.9 ms, p < 0.001), and greater likelihood of fast heart rate dependent PVCs (78.5% vs. 38.2%, p = 0.017). Fourteen (51.8%) patients had an abnormal PET-CT and abnormal late gadolinium enhancement (LGE). Patients with abnormal PET-CT were more frequently treated with immunosuppression (81.4% vs. 3.2%, p < .0001) than with catheter ablation (11.1% vs. 45.9%, p = 0.002) compared to the normal PET-CT group. Over a median follow-up of 862 days (IQR 134, 1407), PVC burden decreased in both groups [from 23 ± 16% to 9 ± 10% (p < 0.001) in abnormal PET-CT group and from 21 ± 15% to 7 ± 10% (p < 0.001) in normal PET-CT group]. CONCLUSIONS: Abnormal PET-CT findings were more commonly associated with NSVT, multiform PVCs, greater PVC coupling interval dispersion, and fast heart rate dependent PVCs. LGE was not sensitive for detecting inflammation. Immunosuppression was effective in managing PVCs with abnormal PET-CT.


Catheter Ablation , Ventricular Premature Complexes , Humans , Adult , Middle Aged , Ventricular Premature Complexes/diagnostic imaging , Ventricular Premature Complexes/surgery , Positron Emission Tomography Computed Tomography , Retrospective Studies , Contrast Media , Stroke Volume/physiology , Gadolinium , Positron-Emission Tomography , Inflammation , Catheter Ablation/methods
15.
Crit Pathw Cardiol ; 21(3): 105-113, 2022 09 01.
Article En | MEDLINE | ID: mdl-35994718

Atrial fibrillation (AF) is the most common cardiac arrhythmia and its prevalence is continuously increasing in the United States, leading to a progressive rise in the number of disease-related emergency department (ED) visits and hospitalizations. Although optimal long-term outpatient management for AF is well defined, the guidelines for optimal ED management of acute AF episodes is less clear. Studies have demonstrated that discharging patients with AF from the ED after acute stabilization is both safe and cost effective; however, the majority of these patients in the United States and in our institution are admitted to the hospital. To improve care of these patients, we established a multidisciplinary collaboration to develop an evidence-based systematic approach for the treatment and management of AF in the ED, that led to the creation of the University of California-Cardioversion, Anticoagulation, Rate Control, Expedited Follow-up/Education Atrial Fibrillation Pathway. Our pathway focuses on the acute stabilization of AF, adherence to best practices for anticoagulation, and reduction in unnecessary admissions through discharge from the ED with expedited outpatient follow-up whenever safe. A novel aspect of our pathway is that it is primarily driven by the ED physicians, while other published protocols primarily involve consulting cardiologists to guide management in the ED. Our protocol is very pertinent considering the current trend toward increased AF prevalence in the United States, coupled with a need for widespread implementation of strategies aimed at improving management of these patients while safely reducing hospital admissions and the economic burden of AF.


Atrial Fibrillation , Anticoagulants/therapeutic use , Atrial Fibrillation/epidemiology , Atrial Fibrillation/therapy , Critical Pathways , Emergency Service, Hospital , Hospitalization , Humans , United States/epidemiology
16.
Heart Rhythm ; 19(12): 2064-2072, 2022 12.
Article En | MEDLINE | ID: mdl-35932988

BACKGROUND: The use of cardiac positron emission tomography-computed tomography (PET-CT) is increasingly used for the detection of underlying inflammation in patients with ventricular arrhythmias (ventricular tachycardia/ventricular fibrillation [VT/VF]), but the role of PET-CT remains undefined, particularly for patients who do not meet Task Force criteria for sarcoidosis. OBJECTIVE: The purpose of this study was to determine the utility of PET-CT for clinical evaluation of VT/VF in patients with nonischemic cardiomyopathy. METHODS: Consecutive patients with nonischemic cardiomyopathy and VT/VF who underwent cardiac PET-CT to detect inflammation between 2012 and 2019 were analyzed for baseline demographic characteristics, imaging results, and outcomes. Patients with known sarcoidosis or other conditions requiring immunosuppressive therapy were excluded. RESULTS: PET-CT was performed in 133 patients with mean age 56.3 ± 13.5 years and left ventricular ejection fraction 43% ± 16.1%, with evidence of myocardial inflammation detected in 32 (23.5%). Patients with myocardial inflammation were managed conservatively with medical therapy including immunosuppressive agents. Ten patients with myocardial inflammation ultimately required catheter ablation for ongoing arrhythmias. There was no significant difference in arrhythmia recurrence between PET-positive and PET-negative groups (37.5% vs 32.4%; P = .43) or in time to recurrence (P = .26), in spite of the disparate management strategies. Gadolinium-enhanced cardiac magnetic resonance imaging was performed in 96 patients (72%); however, magnetic resonance imaging did not detect 31% of cases with active inflammation that were otherwise detected on PET-CT. CONCLUSION: The use of PET-CT significantly improves the detection of underlying myocardial inflammation contributing to ventricular arrhythmias. Management of these patients with immunosuppressive medical therapy is effective for arrhythmia control and may obviate the need for invasive ablation procedures in some patients.


Cardiomyopathies , Myocarditis , Sarcoidosis , Tachycardia, Ventricular , Humans , Adult , Middle Aged , Aged , Stroke Volume , Positron Emission Tomography Computed Tomography , Ventricular Function, Left , Tachycardia, Ventricular/diagnosis , Tachycardia, Ventricular/etiology , Tachycardia, Ventricular/therapy , Positron-Emission Tomography , Cardiomyopathies/diagnosis , Cardiomyopathies/diagnostic imaging , Arrhythmias, Cardiac/diagnosis , Arrhythmias, Cardiac/etiology , Arrhythmias, Cardiac/therapy , Sarcoidosis/complications , Sarcoidosis/diagnosis , Sarcoidosis/therapy , Ventricular Fibrillation , Myocarditis/diagnosis , Myocarditis/diagnostic imaging , Inflammation/complications , Inflammation/diagnosis
17.
Resuscitation ; 179: 1-8, 2022 10.
Article En | MEDLINE | ID: mdl-35905864

INTRODUCTION: Respiratory failure is a common cause of pulseless electrical activity (PEA) and asystolic cardiac arrest, but the changes in heart rate (HR) pre-arrest are not well described. We describe HR dynamics prior to in-hospital cardiac arrest (IHCA) among PEA/asystole arrest patients with respiratory etiology. METHODS: In this retrospective study, we evaluated 139 patients with 3-24 hours of continuous electrocardiogram data recorded preceding PEA/asystole IHCA from 2010-2017. We identified respiratory failure cases by chart review and evaluated electrocardiogram data to identify patterns of HR changes, sinus bradycardia or sinus arrest, escape rhythms, and development right ventricular strain prior to IHCA. RESULTS: A higher proportion of respiratory cases (58/73, 79 %) fit a model of HR response characterized by tachycardia followed by rapid HR decrease prior to arrest, compared to non-respiratory cases (30/66, 45 %, p < 0.001). Among the 58 respiratory cases fitting this model, 36 (62 %) had abrupt increase in HR occurring 64 (IQR 23-191) minutes prior to arrest, while 22 (38 %) had stable tachycardia until time of HR decrease. Mean peak HR was 123 ± 21 bpm. HR decrease occurred 3.0 (IQR 2.0-7.0) minutes prior to arrest. Sinus arrest occurred during the bradycardic phase in 42/58 of cases; escape rhythms were present in all but 2/42 (5 %) cases. Right ventricular strain ECG pattern, when present, occurred at a median of 2.2 (IQR -0.05-17) minutes prior to onset of HR decrease. CONCLUSION: IHCAs of respiratory etiology follow a model of HR increase from physiologic compensation to hypoxia, followed by rapid HR decrease prior to arrest.


Cardiopulmonary Resuscitation , Heart Arrest , Respiratory Insufficiency , Heart Arrest/complications , Heart Arrest/therapy , Heart Rate/physiology , Hospitals , Humans , Retrospective Studies
18.
J Forensic Sci ; 67(5): 1924-1931, 2022 Sep.
Article En | MEDLINE | ID: mdl-35883263

Cardiac implantable electronic devices (CIEDs) store information continuously; however, the log of these devices is rarely analyzed in forensic practice. We retrospectively reviewed all cases referred for CIED interrogation by the Los Angeles County Department of Medical Examiner-Coroner between 2001 and 2020. According to the Department's practice, CIED interrogation may be requested for decedents in which details or cause of death are not clear from autopsy and clinical history. The CIED analysis was considered informative for the coroner's investigation either if it detected an arrhythmia or malfunction likely related to decedent's terminal event or if it was essential to determine time of death or identity of decedent. A total of 57 CIEDs were evaluated during the 20-year period. In almost half of cases (26/57: 45.6%), device analysis was informative for coroner's investigation. Arrhythmias likely related to terminal event were commonly detected (21/57: 36.8%). Device malfunction was identified as the likely cause of death in almost 10% of decedents (5/57: 8.8%), including three cases of battery depletion (3/57: 5.3%), one case of misclassification of ventricular tachycardia as supraventricular tachycardia with failure to deliver therapy (1/57: 1.7%), and one case of lead failure due to a broken pacing wire (1/57: 1.7%). Not infrequently, CIED interrogation was essential for determination of time of death (9/57: 15.8%), and there was one case (1/57: 1.7%) in which interrogation was essential for identifying the decedent. Our study shows that postmortem CIED interrogation can provide unique information regarding mechanism and time of death, and decedent's identity.


Defibrillators, Implantable , Pacemaker, Artificial , Arrhythmias, Cardiac , Coroners and Medical Examiners , Humans , Los Angeles , Retrospective Studies
19.
JACC Case Rep ; 4(24): 101645, 2022 Dec 21.
Article En | MEDLINE | ID: mdl-36684037

Infection of leadless pacemakers (LPM) is rare, even in patients at high risk for infections. Only 3 cases of LPM infection have been documented in the literature, all occurring within 1 month of device implantation. We report the first case, to our knowledge, of late-onset LPM infection, developing almost 2 years after implantation. (Level of Difficulty: Beginner.).

20.
JACC Case Rep ; 3(1): 47-52, 2021 Jan.
Article En | MEDLINE | ID: mdl-34317467

A 62-year-old male with symptomatic persistent atrial fibrillation underwent radiofrequency catheter ablation. During exchange of the saline irrigation bag, the patient developed sudden hypotension and bradycardia and was found to have a massive air embolism. Air was successfully aspirated with catheters, and the patient did not suffer any permanent sequelae. (Level of Difficulty: Intermediate.).

...