Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
2.
Eur Heart J Digit Health ; 4(3): 155-164, 2023 May.
Article in English | MEDLINE | ID: mdl-37265873

ABSTRACT

Aims: We aimed to investigate the concordance between heart rate variability (HRV) derived from the photoplethysmographic (PPG) signal of a commercially available smartwatch compared with the gold-standard high-resolution electrocardiogram (ECG)-derived HRV in patients with cardiovascular disease. Methods and results: We prospectively enrolled 104 survivors of acute ST-elevation myocardial infarction, 129 patients after an ischaemic stroke, and 30 controls. All subjects underwent simultaneous recording of a smartwatch (Garmin vivoactive 4; Garmin Ltd, Olathe, KS, USA)-derived PPG signal and a high-resolution (1000 Hz) ECG for 30 min under standardized conditions. HRV measures in time and frequency domain, non-linear measures, as well as deceleration capacity (DC) were calculated according to previously published technologies from both signals. Lin's concordance correlation coefficient (ρc) between smartwatch-derived and ECG-based HRV markers was used as a measure of diagnostic accuracy. A very high concordance within the whole study cohort was observed for the mean heart rate (ρc = 0.9998), standard deviation of the averages of normal-to-normal (NN) intervals in all 5min segments (SDANN; ρc = 0.9617), and very low frequency power (VLF power; ρc = 0.9613). In contrast, detrended fluctuation analysis (DF-α1; ρc = 0.5919) and the square mean root of the sum of squares of adjacent NN-interval differences (rMSSD; ρc = 0.6617) showed only moderate concordance. Conclusion: Smartwatch-derived HRV provides a practical alternative with excellent accuracy compared with ECG-based HRV for global markers and those characterizing lower frequency components. However, caution is warranted with HRV markers that predominantly assess short-term variability.

3.
Nat Med ; 28(9): 1823-1830, 2022 09.
Article in English | MEDLINE | ID: mdl-36031651

ABSTRACT

Digital smart devices have the capability of detecting atrial fibrillation (AF), but the efficacy of this type of digital screening has not been directly compared to usual care for detection of treatment-relevant AF. In the eBRAVE-AF trial ( NCT04250220 ), we randomly assigned 5,551 policyholders of a German health insurance company who were free of AF at baseline (age 65 years (median; interquartile range (11) years, 31% females)) to digital screening (n = 2,860) or usual care (n = 2,691). In this siteless trial, for digital screening, participants used a certified app on their own smartphones to screen for irregularities in their pulse waves. Abnormal findings were evaluated by 14-day external electrocardiogram (ECG) loop recorders. The primary endpoint was newly diagnosed AF within 6 months treated with oral anti-coagulation by an independent physician not involved in the study. After 6 months, participants were invited to cross-over for a second study phase with reverse assignment for secondary analyses. The primary endpoint of the trial was met, as digital screening more than doubled the detection rate of treatment-relevant AF in both phases of the trial, with odds ratios of 2.12 (95% confidence interval (CI), 1.19-3.76; P = 0.010) and 2.75 (95% CI, 1.42-5.34; P = 0.003) in the first and second phases, respectively. This digital screening technology provides substantial benefits in detecting AF compared to usual care and has the potential for broad applicability due to its wide availability on ordinary smartphones. Future studies are needed to test whether digital screening for AF leads to better treatment outcomes.


Subject(s)
Atrial Fibrillation , Atrial Fibrillation/diagnosis , Atrial Fibrillation/drug therapy , Child , Delivery of Health Care , Electrocardiography , Female , Humans , Male , Mass Screening , Smartphone
4.
Eur Heart J ; 43(28): 2698-2709, 2022 07 21.
Article in English | MEDLINE | ID: mdl-35417553

ABSTRACT

AIMS: Newborn mice and humans display transient cardiac regenerative potential that rapidly declines postnatally. Patients who survive a myocardial infarction (MI) often develop chronic heart failure due to the heart's poor regeneration capacity. We hypothesized that the cardiac 'regenerative-to-scarring' transition might be driven by the perinatal shifts observed in the circulating T-cell compartment. METHODS AND RESULTS: Post-MI immune responses were characterized in 1- (P1) vs. 7-day-old (P7) mice subjected to left anterior descending artery ligation. Myocardial infarction induced robust early inflammatory responses (36 h post-MI) in both age groups, but neonatal hearts exhibited rapid resolution of inflammation and full functional recovery. The perinatal loss of myocardial regenerative capacity was paralleled by a baseline increase in αß-T cell (CD4+ and CD8+) numbers. Strikingly, P1-infarcted mice reconstituted with adult T-cells shifted to an adult-like healing phenotype, marked by irreversible cardiac functional impairment and increased fibrosis. Infarcted neonatal mice harbouring adult T-cells also had more monocyte-derived macrophage recruitment, as typically seen in adults. At the transcriptome level, infarcted P1 hearts that received isolated adult T-cells showed enriched gene sets linked to fibrosis, inflammation, and interferon-gamma (IFN-γ) signalling. In contrast, newborn mice that received isolated Ifng-/- adult T-cells prior to MI displayed a regenerative phenotype that resembled that of its age-matched untreated controls. CONCLUSION: Physiological T-cell development or adoptive transfer of adult IFN-γ-producing T-cells into neonates contributed to impaired cardiac regeneration and promoted irreversible structural and functional cardiac damage. These findings reveal a trade-off between myocardial regenerative potential and the development of T-cell competence.


Subject(s)
Myocardial Infarction , Myocytes, Cardiac , Adult , Animals , Disease Models, Animal , Female , Fibrosis , Humans , Inflammation/pathology , Interferon-gamma , Mice , Myocardium/pathology , Myocytes, Cardiac/physiology , Pregnancy , Regeneration/physiology
5.
Lancet Digit Health ; 4(2): e105-e116, 2022 02.
Article in English | MEDLINE | ID: mdl-35090674

ABSTRACT

BACKGROUND: Cardiac autonomic dysfunction after myocardial infarction identifies patients at high risk despite only moderately reduced left ventricular ejection fraction. We aimed to show that telemedical monitoring with implantable cardiac monitors in these patients can improve early detection of subclinical but prognostically relevant arrhythmic events. METHODS: We did a prospective investigator-initiated, randomised, multicentre, open-label, diagnostic trial at 33 centres in Germany and Austria. Survivors of acute myocardial infarction with left ventricular ejection fraction of 36-50% had biosignal analysis for assessment of cardiac autonomic function. Patients with abnormal periodic repolarisation dynamics (≥5·75 deg2) or abnormal deceleration capacity (≤2·5 ms) were randomly assigned (1:1) to telemedical monitoring with implantable cardiac monitors or conventional follow-up. Primary endpoint was time to detection of serious arrhythmic events defined by atrial fibrillation 6 min or longer, atrioventricular block class IIb or higher and fast non-sustained (>187 beats per min; ≥40 beats) or sustained ventricular tachycardia or fibrillation. This study is registered with ClinicalTrials.gov, NCT02594488. FINDINGS: Between May 12, 2016, and July 20, 2020, 1305 individuals were screened and 400 patients at high risk were randomly assigned (median age 64 years [IQR 57-73]); left ventricular ejection fraction 45% [40-48]) to telemedical monitoring with implantable cardiac monitors (implantable cardiac monitor group; n=201) or conventional follow-up (control group; n=199). During median follow-up of 21 months, serious arrhythmic events were detected in 60 (30%) patients of the implantable cardiac monitor group and 12 (6%) patients of the control group (hazard ratio 6·33 [IQR 3·40-11·78]; p<0·001). An improved detection rate by implantable cardiac monitors was observed for all types of serious arrhythmic events: atrial fibrillation 6 min or longer (47 [23%] patients vs 11 [6%] patients; p<0·001), atrioventricular block class IIb or higher (14 [7%] vs 0; p<0·001) and ventricular tachycardia or ventricular fibrillation (nine [4%] patients vs two [1%] patients; p=0·054). INTERPRETATION: In patients at high risk after myocardial infarction and cardiac autonomic dysfunction but only moderately reduced left ventricular ejection fraction, telemedical monitoring with implantable cardiac monitors was highly effective in early detection of subclinical, prognostically relevant serious arrhythmic events. FUNDING: German Centre for Cardiovascular Research (DZHK) and Medtronic Bakken Research Center.


Subject(s)
Arrhythmias, Cardiac/diagnosis , Monitoring, Physiologic/methods , Myocardial Infarction/complications , Myocardial Infarction/physiopathology , Risk Assessment/methods , Telemedicine/methods , Aged , Austria , Female , Germany , Humans , Male , Middle Aged , Prospective Studies
6.
Am Heart J ; 241: 26-34, 2021 11.
Article in English | MEDLINE | ID: mdl-34252387

ABSTRACT

Current guidelines recommend opportunistic screening for subclinical atrial fibrillation (AF) taking advantage of e-health-based technologies. However, the efficacy of a fully scalable e-health-based strategy for AF detection in a head-to-head comparison with routine symptom-based screening is unknown. eBRAVE-AF is an investigator-initiated, digital, prospective, randomized, siteless, open-label, cross-over study to evaluate an e-health-based strategy for detection of AF in a real-world setting. 67,488 policyholders of a large German health insurance company (Versicherungskammer Bayern, Germany) selected by age ≥ 50 years and a CHA2DS2-VASc score ≥ 1 (females ≥2) are invited to participate. Subjects with known AF or on treatment with oral anticoagulation are excluded. After obtaining electronic informed consent, at least 4,400 participants will be randomly assigned to an e-health-based screening strategy or routine symptom-based screening. The e-health-based strategy consists of repetitive one-minute photoplethysmographic (PPG) pulse wave assessments using a certified smartphone app (Preventicus Heartbeats, Preventicus, Jena, Germany), followed by a confirmatory 14-day ECG patch (CardioMem CM 100 XT, Getemed, Teltow, Germany) in case of abnormal findings. After 6 months, participants are crossed over to the other study arm. Primary endpoint is the incidence of newly diagnosed AF leading to oral anticoagulation indicated by an independent physician. Clinical follow-up will be at least 12 months. In both groups, follow-up is performed by 4-week app-based questionnaires, personal contact in case of abnormal findings, and matching with claim-based insurance data and medical reports. At time of writing enrollment is completed. First results are expected to be available in mid-2021.


Subject(s)
Asymptomatic Diseases/epidemiology , Atrial Fibrillation , Mobile Applications , Monitoring, Ambulatory , Telemedicine , Atrial Fibrillation/complications , Atrial Fibrillation/diagnosis , Atrial Fibrillation/drug therapy , Atrial Fibrillation/epidemiology , Cross-Over Studies , Female , Germany/epidemiology , Humans , Insurance, Health/statistics & numerical data , Male , Middle Aged , Monitoring, Ambulatory/instrumentation , Monitoring, Ambulatory/methods , Randomized Controlled Trials as Topic/methods , Smartphone , Telemedicine/instrumentation , Telemedicine/methods
7.
Lancet Respir Med ; 9(8): 863-872, 2021 08.
Article in English | MEDLINE | ID: mdl-34126053

ABSTRACT

BACKGROUND: SARS-CoV-2 entry in human cells depends on angiotensin-converting enzyme 2, which can be upregulated by inhibitors of the renin-angiotensin system (RAS). We aimed to test our hypothesis that discontinuation of chronic treatment with ACE-inhibitors (ACEIs) or angiotensin II receptor blockers (ARBs) mitigates the course o\f recent-onset COVID-19. METHODS: ACEI-COVID was a parallel group, randomised, controlled, open-label trial done at 35 centres in Austria and Germany. Patients aged 18 years and older were enrolled if they presented with recent symptomatic SARS-CoV-2 infection and were chronically treated with ACEIs or ARBs. Patients were randomly assigned 1:1 to discontinuation or continuation of RAS inhibition for 30 days. Primary outcome was the maximum sequential organ failure assessment (SOFA) score within 30 days, where death was scored with the maximum achievable SOFA score. Secondary endpoints were area under the death-adjusted SOFA score (AUCSOFA), mean SOFA score, admission to the intensive care unit, mechanical ventilation, and death. Analyses were done on a modified intention-to-treat basis. This trial is registered with ClinicalTrials.gov, NCT04353596. FINDINGS: Between April 20, 2020, and Jan 20, 2021, 204 patients (median age 75 years [IQR 66-80], 37% females) were randomly assigned to discontinue (n=104) or continue (n=100) RAS inhibition. Within 30 days, eight (8%) of 104 died in the discontinuation group and 12 (12%) of 100 patients died in the continuation group (p=0·42). There was no significant difference in the primary endpoint between the discontinuation and continuation group (median [IQR] maximum SOFA score 0·00 (0·00-2·00) vs 1·00 (0·00-3·00); p=0·12). Discontinuation was associated with a significantly lower AUCSOFA (0·00 [0·00-9·25] vs 3·50 [0·00-23·50]; p=0·040), mean SOFA score (0·00 [0·00-0·31] vs 0·12 [0·00-0·78]; p=0·040), and 30-day SOFA score (0·00 [10-90th percentile, 0·00-1·20] vs 0·00 [0·00-24·00]; p=0·023). At 30 days, 11 (11%) in the discontinuation group and 23 (23%) in the continuation group had signs of organ dysfunction (SOFA score ≥1) or were dead (p=0·017). There were no significant differences for mechanical ventilation (10 (10%) vs 8 (8%), p=0·87) and admission to intensive care unit (20 [19%] vs 18 [18%], p=0·96) between the discontinuation and continuation group. INTERPRETATION: Discontinuation of RAS-inhibition in COVID-19 had no significant effect on the maximum severity of COVID-19 but may lead to a faster and better recovery. The decision to continue or discontinue should be made on an individual basis, considering the risk profile, the indication for RAS inhibition, and the availability of alternative therapies and outpatient monitoring options. FUNDING: Austrian Science Fund and German Center for Cardiovascular Research.


Subject(s)
Angiotensin Receptor Antagonists , Angiotensin-Converting Enzyme Inhibitors , COVID-19 , Hypertension , Renin-Angiotensin System , SARS-CoV-2 , Angiotensin Receptor Antagonists/administration & dosage , Angiotensin Receptor Antagonists/adverse effects , Angiotensin-Converting Enzyme 2/metabolism , Angiotensin-Converting Enzyme Inhibitors/administration & dosage , Angiotensin-Converting Enzyme Inhibitors/adverse effects , Area Under Curve , COVID-19/epidemiology , COVID-19/metabolism , COVID-19/therapy , Female , Humans , Hypertension/drug therapy , Hypertension/epidemiology , Male , Middle Aged , Organ Dysfunction Scores , Outcome and Process Assessment, Health Care , Renin-Angiotensin System/drug effects , Renin-Angiotensin System/physiology , Risk Adjustment/methods , SARS-CoV-2/drug effects , SARS-CoV-2/physiology , Severity of Illness Index , Withholding Treatment/statistics & numerical data
SELECTION OF CITATIONS
SEARCH DETAIL
...