Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 37
Filter
1.
G Ital Cardiol (Rome) ; 25(6): 23-37, 2024 Jun.
Article in Italian | MEDLINE | ID: mdl-38912744

ABSTRACT

STENT PANORAMA is a project carried out by the Young Interventional Cardiologists of Triveneto coordinated by the Italian Society of Interventional Cardiology (GISE) Veneto delegation. The project includes two parts: the first, here reported, is aimed at describing in a standardized and easily usable way the main technological characteristics of the latest generation of the drug eluting stents (DES) that are most widely used in the Italian cath-labs. The second, to follow, will aim to summarize the main scientific evidence regarding the performance of individual devices with particular reference to subgroups of clinical interest. The ambitious goal of the STENT PANORAMA working group is to provide the interventional cardiologist with a thorough, practical, and functional knowledge of the DES currently available in the modern therapeutic armamentarium to promote a therapeutic strategy tailored to the patient.


Subject(s)
Drug-Eluting Stents , Humans , Italy , Percutaneous Coronary Intervention/methods , Prosthesis Design , Coronary Artery Disease/therapy , Coronary Artery Disease/surgery
2.
Article in English | MEDLINE | ID: mdl-38749449

ABSTRACT

BACKGROUND: Transcatheter aortic valve replacement (TAVR) in patients with bicuspid aortic valve (BAV) stenosis is technically challenging and is burdened by an increased risk of paravalvular regurgitation (PVR). OBJECTIVES: To identify the incidence, predictors, and clinical outcomes of PVR following TAVR in Sievers type 1 BAV stenosis. METHODS: Consecutive patients with severe Sievers type 1 BAV stenosis undergoing TAVR with current generation transcatheter heart valves (THVs) in 24 international centres were enrolled. PVR was graded as none/trace, mild, moderate, and severe according to echocardiographic criteria. The endpoint of major adverse events (MAE), defined as a composite of all-cause death, stroke, or hospitalization for heart failure, was assessed at the last available follow-up. RESULTS: A total of 946 patients were enrolled. PVR occurred in 423 patients (44.7%): mild, moderate, and severe in 387 (40.9%), 32 (3.4%), and 4 (0.4%) patients, respectively. Independent predictors of moderate or severe PVR were larger virtual raphe ring (VRR) perimeter (ORadj 1.07, 95% CI 1.02-1.13), severe annular or left ventricular outflow tract (LVOT) calcification (ORadj 5.21, 95% CI 1.45-18.77), self-expanding valve (ORadj 9.01, 95% CI 2.09-38.86), and intentional supra-annular THV positioning (ORadj 3.31, 95% CI 1.04-10.54). At a median follow-up of 1.3 [IQR 0.5-2.4] years, moderate or severe PVR was associated with an increased risk of MAE (HRadj 2.52, 95% CI 1.24-5.09). CONCLUSIONS: After TAVR with current-generation THVs in Sievers type 1 BAV stenosis, moderate or severe PVR occurred in about 4% of cases and was associated with an increased risk of MAE during follow-up.

3.
Am J Cardiol ; 2024 May 08.
Article in English | MEDLINE | ID: mdl-38729335

ABSTRACT

The long-term safety and effectiveness of transcatheter aortic valve replacement (TAVR) compared with surgical aortic valve replacement (SAVR) in low surgical risk has not been evaluated in a pooled analysis. An electronic database search was conducted for randomized controlled trials with a maximal 5 years clinical and echocardiographic follow-up including low surgical risk patients who underwent TAVR or SAVR. We calculated odds ratio (OR) and 95% confidence intervals (CIs) using a random-effects model. Subgroups analysis was performed for permanent pacemaker implantation and paravalvular leaks. Three randomized controlled trials were included with a total of 2,611 low surgical risk patients (Society of Thoracic Surgeons score <4%). Compared with SAVR, the TAVR group had similar rates of all-cause mortality (OR 0.94,95% CI 0.65 to 1.37, p = 0.75) and disabling stroke (OR 0.84, 95% CI 0.52 to 1.36, p = 0.48). No significant differences were registered in the TAVR group in terms of major cardiovascular events (OR 0.96, 95% CI 0.67 to 1.38, p = 0.83), myocardial infarction (OR 0.69, 95% CI 0.34 to 1.40, p = 0.31), valve thrombosis (OR 3.11, 95% CI 0.29 to 33.47, p = 0.35), endocarditis (OR 0.71,95% CI 0.35 to 1.48, p = 0.36), aortic valve reintervention (OR 0.93, 95% CI 0.52 to 1.66, p = 0.80), and rehospitalization (OR 0.80, 95% CI 0.52 to 1.02, p = 0.07) compared with SAVR. However, TAVR patients had a higher risk of paravalvular leaks (OR 8.21, 95% CI 4.18 to 16.14, p <0.00001), but lower rates of new-onset atrial fibrillation (OR 0.27,95% CI 0.17 to 0.30, p <0.0001). The rates of permanent pacemaker implantation were comparable from 1 year up to a maximum of 5 years (OR 1.32, 95% CI 0.88 to 1.97, p = 0.18). Lastly, TAVR had a greater effective orifice area (0.10 cm2/m2, 95% CI 0.05 to 0.15, p = 0.0001), but similar transvalvular mean gradients (0.60, 95% CI 3.94 to 2.73, p = 0.72). In conclusion, TAVR patients had similar long-term outcomes compared with SAVR, except for an elevated risk of paravalvular leaks in the TAVR group and increased rates of atrial fibrillation in the SAVR cohort.

4.
Eur J Clin Invest ; : e14209, 2024 Apr 10.
Article in English | MEDLINE | ID: mdl-38597271

ABSTRACT

BACKGROUND: In the last few years, percutaneous LAA occlusion (LAAO) has become a plausible alternative in atrial fibrillation (AF) patients with contraindications to anticoagulation therapy. Nevertheless, the optimal antiplatelet strategy following percutaneous LAAO remains to be defined. METHODS: Studies comparing single antiplatelet therapy (SAPT) versus dual antiplatelet therapy (DAPT) following LAAO were systematically searched and screened. The outcomes of interest were ischemic stroke, device-related thrombus (DRT) and major bleeding. A random-effect meta-analysis was performed comparing outcomes in both groups. The moderator effect of baseline characteristics on outcomes was evaluated by univariate meta-regression analyses. RESULTS: Sixteen observational studies with 3255 patients treated with antiplatelet therapy (SAPT, n = 1033; DAPT, n = 2222) after LAAO were included. Mean age was 74.5 ± 8.3 years, mean CHA2DS2-VASc and HAS-BLED scores were 4.3 ± 1.5 and 3.2 ± 1.0, respectively. At a weighted mean follow-up of 12.7 months, the occurrence of stroke (RR 1.33; 95% CI 0.64-2.77; p =.44), DRT (RR 1.52; 95% CI 0.90-2.58; p =.12), and the composite of stroke and DRT (RR 1.26; 95% CI 0.67-2.37; p =.47) did not differ significantly between SAPT and DAPT groups. The rate of major bleedings was also not different between groups (RR 1.41; 95% CI 0.64-3.12; p =.39). CONCLUSIONS: Among AF patients at high bleeding risk undergoing percutaneous LAAO, a post-procedural minimalistic antiplatelet strategy with SAPT did not significantly differ from DAPT regimens regarding the rate of stroke, DRT and major bleeding.

5.
EuroIntervention ; 20(8): e504-e510, 2024 Apr 15.
Article in English | MEDLINE | ID: mdl-38629420

ABSTRACT

The treatment of coronary artery disease (CAD) in patients with severe aortic valve stenosis (AVS) eligible for transcatheter aortic valve implantation (TAVI) is not supported by clinical evidence, and the role of physiology over anatomy as well as the timing of coronary intervention are not defined. FAITAVI (ClinicalTrials.gov: NCT03360591) is a nationwide prospective, open-label, multicentre, randomised controlled study comparing the angiography-guided versus the physiology-guided coronary revascularisation strategy in patients with combined significant CAD and severe AVS undergoing TAVI. Significant CAD will be defined as coronary stenosis ≥50%, as assessed by visual estimation in vessels ≥2.5 mm. Physiology will be tested by fractional flow reserve (FFR) and instantaneous wave-free ratio (iFR). The study will be conducted at 15 sites in Italy. In the angiography arm, percutaneous coronary intervention (PCI) will be performed either before TAVI, during the TAVI procedure - before or after the valve implantation - or within 1 month±5 days of the valve implantation, left to the operator's decision. In the physiology arm, FFR and iFR will be performed before TAVI, and PCI will be indicated for FFR ≤0.80, otherwise the intervention will be deferred. In case of borderline values (0.81-0.85), FFR and iFR will be repeated after TAVI, with PCI performed when needed. With a sample size of 320 patients, the study is powered to evaluate the primary endpoint (a composite of death, myocardial infarction, stroke, major bleeding, or ischaemia-driven target vessel revascularisation). TAVI indication, strategy and medical treatment will be the same in both groups. After discharge, patients will be contacted at 1, 6, 12 and 24 months after the procedure to assess their general clinical status, and at 12 months for the occurrence of events included in the primary and secondary endpoints. FAITAVI is the first randomised clinical trial to investigate "optimal" percutaneous coronary intervention associated with TAVI in patients with severe AVS and CAD.


Subject(s)
Aortic Valve Stenosis , Coronary Artery Disease , Fractional Flow Reserve, Myocardial , Percutaneous Coronary Intervention , Transcatheter Aortic Valve Replacement , Humans , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/complications , Coronary Angiography , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/surgery , Prospective Studies , Treatment Outcome , Multicenter Studies as Topic , Randomized Controlled Trials as Topic
7.
Heart ; 110(1): 27-34, 2023 Dec 15.
Article in English | MEDLINE | ID: mdl-37414524

ABSTRACT

OBJECTIVE: The European Society of Cardiology guidelines have recently defined new cut-offs for pulmonary hypertension (PH) and pulmonary vasculature resistance (PVR; median pulmonary artery pressure (mPAP) >20 instead of 25 mm Hg and PVR >2 instead of 3 Wood unit). The prognostic value of this updated classification after transcatheter aortic valve implantation (TAVI) is unknown. METHODS: 579 consecutive patients treated by TAVI with preprocedural right heart catheterisation evaluation were included. Patients were grouped as: (1) no PH, (2) isolated precapillary/combined (I-PreC/Co) PH and (3) isolated postcapillary PH (I-PoC). All-cause death, cardiovascular death and hospitalisations for heart failure (HF) were evaluated at follow-up. We also analysed the prognostic role of residual postprocedural PH. RESULTS: Out of 579 patients, 299 (52%) had PH according to the new criteria compared with 185 (32%) according to the previous ones. Overall median age was 82 years, while 55.3% patients were male. Patients with PH were more frequently diagnosed with chronic obstructive pulmonary disease and atrial fibrillation and were characterised by higher surgical risk as compared with patients without PH.At a median follow-up of 2.9 years, the presence of PH according to previous definition was associated with worse survival (p<0.001) and HF hospitalisation (p=0.002) rates, irrespective of PVR values. With newer cut-offs, PH was associated with worse outcomes only in patients with increased PVR, while no differences were found between patients with PH and normal PVR values and those without PH. Postprocedural mPAP normalisation was observed in 45% of the cases, but it was associated with improved long-term survival only in the I-PoC PH group. CONCLUSIONS: New ESC PH cut-offs increased the number of PH diagnoses. The presence of PH, particularly in the setting of increased PVR, identify patients at higher risk for postprocedural mortality and rehospitalisation. Normalisation of PH was associated with better survival only in I-PoC group.


Subject(s)
Aortic Valve Stenosis , Heart Failure , Hypertension, Pulmonary , Transcatheter Aortic Valve Replacement , Humans , Male , Aged, 80 and over , Female , Transcatheter Aortic Valve Replacement/adverse effects , Hypertension, Pulmonary/diagnosis , Hypertension, Pulmonary/etiology , Aortic Valve Stenosis/complications , Aortic Valve Stenosis/diagnosis , Aortic Valve Stenosis/surgery , Aortic Valve/surgery , Prognosis , Treatment Outcome , Risk Factors
9.
Front Cardiovasc Med ; 9: 1056496, 2022.
Article in English | MEDLINE | ID: mdl-36578836

ABSTRACT

Objectives: To assess the impact of conventional transcatheter heart valve (THV) commissural alignment techniques on THV/coronary overlap and coronary access (CA) after transcatheter aortic valve replacement (TAVR) in bicuspid aortic valve (BAV). Background: Specific Evolut Pro/Pro + and Acurate Neo2 THV orientations are associated with reduced neo-commissural overlap with coronary ostia in tricuspid aortic anatomy. Whether standard orientation techniques are effective also in the setting of BAV anatomy has not been studied. Methods: The DA VINCI (Definition of trAnscatheter aortic Valve orIeNtation in biCuspId aortic valve) pilot study is a prospective registry enrolling consecutive patients with severe BAV stenosis undergoing TAVR with last generation supra-annular tall-frame THVs implanted with a cusp overlap view-based commissural alignment. Patients underwent pre- and post-TAVR computed tomography (CT) and coronary angiography. The study endpoint was the rate of favorable THV/coronary overlap, defined as an angle > 40° between the THV commissural post and coronary ostia. Other endpoints were the rates of successful THV alignment with respect to the raphe and of selective CA after TAVR. Moreover, different virtual THV alignment models were tested to identify which one would produce the lower degree of THV/coronary overlap. Results: Thirty-four patients with type 1 BAV with right-left raphe undergoing TAVR (23 with Evolut Pro/Pro + and 11 with Acurate Neo2) were included. At pre-TAVR CT, moderate/severe cusp asymmetry was found in 50% of patients, severe coronary ostia eccentricity was observed in 47.1% for the RCA vs. 8.8% for the LCA (P < 0.007). Correct TVH orientation was achieved in 29 cases. At post-TAVR CT, optimal THV alignment/mild misalignment to the raphe was observed in 86.2%, but a moderate/severe overlap with the coronaries was seen in 13.7% for the RCA and 44.8% for the LCA (P = 0.019). After TAVR, selective RCA cannulation was possible in 82.8% vs. 75.9% for the LCA (P = 0.74), while combined selective CA of both coronaries was possible in less than two-thirds of the patients. Virtual THV alignment in the coronary ostia overlap view assuming a hypothetical circular THV expansion would produce an optimal THV/coronary overlap in almost 90% of cases. Conclusion: Given cusp asymmetry and coronary ostia eccentricity of BAV combined with potential THV asymmetrical expansion, conventional commissural alignment techniques are associated with higher rates of THV misalignment and of moderate/severe neo-commissure overlap with the coronary ostia as compared to tricuspid aortic stenosis, resulting in lower rates of selective CA after TAVR. A modified THV orientation technique based on the coronary ostia overlap view might be preferable in BAV patients.

11.
JACC Cardiovasc Interv ; 15(18): 1777-1793, 2022 09 26.
Article in English | MEDLINE | ID: mdl-36137681

ABSTRACT

Transcatheter aortic valve replacement (TAVR) is increasingly being performed in younger and lower surgical risk patients. Given the longer life expectancy of these patients, the bioprosthetic valve will eventually fail, and aortic valve reintervention may be necessary. Although currently rare, redo-TAVR will likely increase in the future as younger patients are expected to outlive their transcatheter bioprosthesis. This review provides a contemporary overview of the indications, procedural planning, implantation technique, and outcomes of TAVR in failed transcatheter bioprosthetic aortic valves.


Subject(s)
Aortic Valve Stenosis , Bioprosthesis , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/etiology , Aortic Valve Stenosis/surgery , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/methods , Humans , Prosthesis Design , Prosthesis Failure , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/methods , Treatment Outcome
12.
Front Cardiovasc Med ; 9: 924958, 2022.
Article in English | MEDLINE | ID: mdl-35757343

ABSTRACT

Background: The impact of transcatheter aortic valve replacement (TAVR) leaflet design on long-term device performance is still unknown. This study sought to compare the clinical and hemodynamic outcomes of intra- (IA) versus supra-annular (SA) TAVR designs up-to 10-years following implantation. Methods: Consecutive patients with at least 5-years follow-up following TAVR for severe symptomatic aortic stenosis from June 2007 to December 2016 were included. Bioprosthetic valve failure (BVF) and hemodynamic valve deterioration (HVD) were defined according to VARC-3 updated definitions and estimated using cumulative incidence function to account for the competing risk of death. Results: A total of 604 patients (82 years; 53% female) were analyzed and divided into IA (482) and SA (122) groups. Overall survival rates at 10-years were similar (IA 15%, 95%CI: 10-22; SA 11%, 95%CI: 6-20; p = 0.21). Compared to the SA TAVR, mean transaortic gradients were significantly higher and increased over time in the IA group. IA TAVRs showed higher 10-year cumulative incidences of BVF (IA 8% vs. SA 1%, p = 0.02) and severe HVD (IA 5% vs. SA 1%, p = 0.05). The occurrence of BVF and HVD in the IA group occurred primarily in the smallest TAVR devices (20-23-mm). After excluding these sizes, the cumulative incidences of BVF (IA 5% vs. SA 1%, p = 0.40) and severe HVD (IA 2% vs. SA 1%, p = 0.11) were similar. Conclusion: In this study, TAVR leaflet design had no impact on survival at 10-years. IA devices showed higher transaortic gradients and cumulative incidences of HVD and BVF predominantly occurring in the smallest valve sizes.

13.
Front Cardiovasc Med ; 9: 832242, 2022.
Article in English | MEDLINE | ID: mdl-35295263

ABSTRACT

Backgrounds: Among vascular closure devices (VCDs), the novel collagen plug-based MANTA VCD is the first designed for large bore percutaneous access. We aimed to assess the features and predictors of access-site vascular complications in an unselected trans-femoral transcatheter aortic valve replacement (TF-TAVR) population. Methods: Patients undergoing large bore arteriotomy closure with 18F MANTA VCD following TF-TAVR at a large tertiary care center from September 2019 to January 2021 were prospectively analyzed. Primary Outcome was the MANTA VCD access-site-related complications according to Valve Academic Research Consortium-3 (VARC) definitions. Its incidence and predictors were evaluated. Results: Eighty-eight patients (median age 82 years, 48% male, 3.3 median Society of Thoracic Surgeons score) undergoing TF-TAVR were included, mostly (63%) treated with a self-expandable device and with outer diameter sizes varied from 18F to 24-F. MANTA VCD technical success rate was 98%, while 10 patients (11%) experienced MANTA VCD access-site vascular complications which included 8% of minor complications and only to 2% of major events resulting in VARC type ≥2 bleeding. Vessel occlusion/stenosis (60%), perforation (20%), and pseudoaneurysm/dissection/hematoma (20%) occurred, but all were managed without surgical treatment. Independent predictors of failure were age (p = 0.04), minimum common femoral artery diameter (CFA) (p < 0.01), sheath-to-femoral-artery ratio (SFAR) (p < 0.01), and a lower puncture height (p = 0.03). A CFA diameter <7.1 mm with a SFAR threshold of 1.01 were associated with VCD failure. Conclusions: In a more comers TF-TAVR population, MANTA VCD was associated with reassuring rates of technical success and major access-site vascular complications. Avoiding lower vessel size and less puncture site distance to CFA bifurcation might further improve outcomes.

14.
Circ Cardiovasc Interv ; 15(2): e011045, 2022 02.
Article in English | MEDLINE | ID: mdl-35167332

ABSTRACT

BACKGROUND: Coronary access (CA) after transcatheter aortic valve replacement (TAVR) with supra-annular transcatheter heart valves (THV) can be challenging. Specific Evolut R/Pro and Acurate Neo THVs orientations are associated with reduced neo-commissure overlap with coronary ostia, while SAPIEN 3 THV cannot be oriented. With the ALIGN-ACCESS study (TAVR With Commissural Alignment Followed by Coronary Access), we investigated the impact of commissural alignment on the feasibility of CA after TAVR. METHODS: We performed coronary angiography after TAVR with intra-annular SAPIEN 3, supra-annular Evolut R/Pro, and Acurate Neo THVs in 206 patients. Evolut THVs were implanted aiming for commissure alignment. Alignment of Acurate Neo was retrospectively assessed in 36, intentionally attempted in 26 cases. The primary end point was the rate of unfeasible and nonselective CA after TAVR. RESULTS: Thirty-eight percent of patients received SAPIEN 3, 31.1% Evolut Pro/R, 30.1% Acurate Neo THV. Final valve orientation was favorable to commissural alignment in 85.9% of Evolut and 69.4% of Acurate Neo cases (with intentional alignment successful in 88.5%). Selective CA was higher for SAPIEN 3 than for aligned and misaligned supra-annular THVs (95% versus 71% versus 46%, P<0.001). Cannulation of at least one coronary was unfeasible with 11% misaligned supra-annular, 3% aligned supra-annular, and 0% SAPIEN 3 THVs. Independent predictors of unfeasible/nonselective CA were implantation of a misaligned supra-annular THV (odds ratio, 4.59 [95% CI, 1.81-11.61]; P<0.01), sinus of Valsalva height (odds ratio, 0.83 [95% CI, 0.7-0.98]; P=0.03), and THV-sinus of Valsalva relation (odds ratio, 1.06 [95% CI, 1.02-1.1]; P<0.01). CONCLUSIONS: Commissural alignment improves the rate of selective CA after TAVR with supra-annular THVs. Nevertheless, aligned supra-annular THVs carry higher risk of unfeasible/nonselective CA than SAPIEN 3. Patients with a misaligned supra-annular THV, low sinus of Valsalva, and higher THV-sinus of Valsalva relation are at highest risk of impaired CA after TAVR.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Humans , Prosthesis Design , Retrospective Studies , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
15.
Int J Cardiol ; 339: 219-224, 2021 Sep 15.
Article in English | MEDLINE | ID: mdl-34181996

ABSTRACT

AIMS: Cardiac complications are a leading cause of mortality after orthotopic liver transplantation (LT) and pre-operative risk stratification is challenging. We evaluated whether coronary artery calcium (CAC) score calculated on a standard (non-thin layer, non-ECG gated) chest computed tomography (CT) predicted cardiac outcome after LT. METHODS: We included a consecutive series of LT recipients who underwent pre-operative cardiac evaluation including stress-testing or cardiac catheterization in high-risk patients. Patients with a history of coronary artery disease or coronary revascularization were excluded. The CAC score was calculated from the chest CT routinely performed before LT. CAC values were not available at the time of pre-transplant cardiac evaluation and did not affect LT eligibility. The primary end-point included peri-operative arrhythmic cardiac arrest and sustained ventricular arrhythmias; heart failure, myocardial infarction and cardiac death within 1-year after LT. RESULTS: The study population consisted of 301 patients (median age 56 years, 76% males). At chest CT, 49% had CAC = 0; 27% had CAC = 1-99, 15% had CAC = 100-399 and 9% CAC > 400. The primary end-point incidence increased from 7% in patients with CAC = 0 to 27% in patients with CAC > 400 (p = 0.007). At multivariable analysis including traditional risk factors, CAC remained an independent predictor of cardiac events (p = 0.01). CONCLUSIONS: CAC score calculated on a standard chest CT stratified the risk of cardiac events in patients who underwent LT after negative pre-transplant cardiac evaluation. These findings suggest that evaluation of CAC from a standard chest CT performed for other reasons can be used as an early cardiac risk stratification tool before LT.


Subject(s)
Coronary Artery Disease , Liver Transplantation , Vascular Calcification , Calcium , Coronary Angiography , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/surgery , Coronary Vessels/diagnostic imaging , Coronary Vessels/surgery , Female , Humans , Liver Transplantation/adverse effects , Male , Middle Aged , Predictive Value of Tests , Risk Factors , Tomography, X-Ray Computed
16.
Circ Cardiovasc Interv ; 14(7): e009827, 2021 07.
Article in English | MEDLINE | ID: mdl-34130478

ABSTRACT

The bicuspid aortic valve (BAV) represents a complex anatomic scenario for transcatheter aortic valve replacement (TAVR) because of its unique technical challenges. As TAVR is moving towards younger and lower-risk populations, the proportion of BAV patients undergoing TAVR is expected to rise. Initial experiences of TAVR with first-generation transcatheter heart valves in high surgical risk patients with BAV stenosis showed higher rates of device failure and periprocedural complications as compared to tricuspid anatomy. The subsequent advances in imaging techniques and understanding of BAV anatomy, new iterations of transcatheter heart valves, and growing operators' experience yielded better outcomes. However, in the lack of randomized trials and rigorous evidence, the field of TAVR in BAV has been driven by empirical observations, with wide variability in transcatheter heart valve sizing and implantation techniques across different centers and operators. Thus, in this review article, we provide a fully illustrated overview of operative periprocedural steps for TAVR in BAV stenosis, though recognizing that it still remains anecdotal.


Subject(s)
Aortic Valve Stenosis , Bicuspid Aortic Valve Disease , Transcatheter Aortic Valve Replacement , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Constriction, Pathologic , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
17.
Catheter Cardiovasc Interv ; 98(4): E581-E585, 2021 10.
Article in English | MEDLINE | ID: mdl-34128584

ABSTRACT

Spontaneous coronary artery dissection (SCAD) can lead to acute coronary syndrome and sudden cardiac death, particularly in young women. Observational data show that, in SCAD patients, both percutaneous coronary intervention and coronary artery bypass grafting seem to be hampered by higher technical complexity, lower success rates, and worse outcomes. As spontaneous healing is a common occurrence, expert consensus advices medical management of the acute phase, when feasible. We present the case of a young woman with SCAD of left anterior descending artery causing myocardial infarction with ST-segment elevation. High-anatomical complexity and unstable conditions of the patient made both medical management and immediate revascularization unfeasible options. Therefore, we decided to implant a percutaneous off-loading mechanical support device to improve coronary perfusion pressure by unloading the left ventricle and preserve cardiac function, preventing worse complications of acute myocardial infarction. This strategy was successful in stabilizing the patient, until the definitive revascularization treatment became an option.


Subject(s)
Coronary Vessels , Heart Ventricles , Dissection , Female , Humans , Perfusion , Treatment Outcome
18.
Catheter Cardiovasc Interv ; 97(4): E536-E543, 2021 03.
Article in English | MEDLINE | ID: mdl-32584507

ABSTRACT

BACKGROUND: Stroke is a feared complication of transcatheter aortic valve replacement (TAVR) and surgical aortic valve replacement (SAVR). OBJECTIVES: With this meta-analysis we aimed to evaluate the incidence of 30-day stroke with TAVR and SAVR focusing on its possible correlation with surgical risk. METHODS: Major electronic databases were searched for studies published between January 2002 and October 2019 reporting the rates of 30-day stroke after TAVR and SAVR. Data were pooled using fixed- and random-effects models. The primary outcome of the study was stroke rate within 30-day from TAVR or SAVR. Results were stratified according to surgical risk score (high, intermediate and low). RESULTS: A total of 23 studies were identified (TAVR: 14,589 patients; SAVR: 11,681 patients). Regardless of the model used, in the overall population TAVR was associated with a significant reduction in the risk of stroke compared with SAVR (fixed effect: OR 0.78, 95% CI 0.66-0.92, p = .003; random-effects: OR 0.80, 95% CI 0.64-1.00, p = .045). Rates of 30-day stroke after TAVR and SAVR were not significantly different in the high- (OR 1.01, 95% CI 0.44-1.98, p = .105) and intermediate-risk groups (OR 0.92, 95% CI 0.63-1.36, p = .319), while low-risk patients had a lower rate of 30-day stroke after TAVR than SAVR (OR 0.65, 95% CI 0.50-0.83, p < .001). Meta-regression showed a significant association between surgical risk score and 30-day stroke rate (p = .007). CONCLUSIONS: TAVR is associated with a lower risk of 30-day stroke compared with SAVR, mainly as a result of the significant advantage observed in patients at low surgical risk.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis Implantation , Stroke , Transcatheter Aortic Valve Replacement , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Heart Valve Prosthesis Implantation/adverse effects , Humans , Risk Factors , Stroke/epidemiology , Stroke/etiology , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
19.
G Ital Cardiol (Rome) ; 22(12 Suppl 2): 31-36, 2021 12.
Article in Italian | MEDLINE | ID: mdl-35343489

ABSTRACT

In the last decades, the wide use of surgical aortic bioprostheses translated into an increased rate of valve degeneration and dysfunction. However, most patients are excluded from surgical re-do due to high or prohibitive operative risk. In this clinical context, valve-in-valve transcatheter aortic valve implantation (ViV-TAVI) has been shown to be effective. Nevertheless, some relevant concerns, such as elevated residual transvalvular gradient and coronary artery obstruction, still remain. Detailed information regarding the degenerated surgical bioprosthesis and a thorough analysis of the computed tomography scan are essential for accurate pre-procedural planning and may avoid dramatic acute complications. Moreover, in difficult cases, the use of some tips and tricks may help expert operators to achieve better results.Here we report the case of a patient affected by structural degeneration of a small label size surgical aortic valve, who was excluded from surgical reintervention due to high operative risk. Therefore, we decided to perform a ViV-TAVI despite the presence of challenging features.


Subject(s)
Bioprosthesis , Heart Valve Prosthesis , Aortic Valve/surgery , Humans , Prosthesis Design , Prosthesis Failure , Treatment Outcome
20.
G Ital Cardiol (Rome) ; 22(12 Suppl 2): 37-41, 2021 12.
Article in Italian | MEDLINE | ID: mdl-35343490

ABSTRACT

Coronary artery disease is a frequent comorbidity in patients with severe aortic stenosis undergoing trans-catheter aortic valve implantation (TAVI) and the need to ensure coronary access after TAVI is fundamental. This aspect is becoming increasingly relevant as TAVI indication expand to younger and lower-risk patients. Moreover, the longer life expectancy of subjects who are currently treated with TAVI could result in an increased need for TAVI-in-TAVI due to valve degeneration. As the implantation of a second transcatheter bioprosthesis might impair coronary access, TAVI-in-TAVI will be unfeasible in a significant proportion of cases, particularly if they received a tall-frame transcatheter heart valve at the time of the first intervention. Thus, patients might experience the paradox of needing surgical aortic valve replacement when they are older and frailer. Here we report the case of a patient with history of coronary artery disease and severe aortic stenosis treated with TAVI, presenting with an acute coronary syndrome 8 years after percutaneous aortic valve implantation. Thanks to the low frame height of the transcatheter aortic valve, it was possible to easily perform coronary angiography and high-risk percutaneous coronary intervention using hemodynamic support device (Impella CP). Moreover, this case highlights how the implantation of a low-frame transcatheter prosthesis can increase the possibility of achieving coronary access even after TAVI-in-TAVI, if needed.


Subject(s)
Aortic Valve Stenosis , Percutaneous Coronary Intervention , Transcatheter Aortic Valve Replacement , Aortic Valve Stenosis/surgery , Coronary Angiography , Hemodynamics , Humans , Transcatheter Aortic Valve Replacement/methods
SELECTION OF CITATIONS
SEARCH DETAIL
...