ABSTRACT

BACKGROUND AND IMPORTANCE: Despite technological advances, ruptured wide-necked aneurysms continue to pose a challenge for endovascular management. Comaneci (Rapid Medical) is a relatively new temporary aneurysm neck bridging device to assist in coiling of wide-necked aneurysms without the need for dual antiplatelet therapy or parent vessel flow interruption. Y configuration is often necessary to prevent coil migration in cases of wide-necked aneurysms. Thus far, there have been no reports of using Comaneci device in Y configuration to aid anterior circulation aneurysm treatment. CLINICAL PRESENTATION: A 60-year-old man presented with a Hunt-Hess grade 5, modified Fisher grade 4 subarachnoid hemorrhage from a ruptured wide-necked anterior communicating artery aneurysm with a dome-to-neck ratio of 1:2. Two Comaneci devices were used in a Y configuration to prevent coil prolapse into the contralateral A2 branch. After successful coiling of the aneurysm, both Comaneci devices were collapsed and removed without incident; the coil catheter was also removed without incident. Follow-up angiogram demonstrated successful occlusion of the wide-necked anterior communicating artery aneurysm without the use of a permanent stent or balloon assistance. CONCLUSION: This case represents a first-time report of successfully using 2 Comaneci devices in a Y configuration for the treatment of a ruptured wide-necked anterior circulation aneurysm. This knowledge can potentially further expand the use of double Comaneci devices in Y configuration for the treatment of both anterior and posterior circulation aneurysms.

2.
Front Neurol ; 11: 83, 2020.
Article in English | MEDLINE | ID: mdl-32132966

ABSTRACT

Background and Objective: The first pass effect (FPE; achieving complete recanalization with a single thrombectomy device pass) has been shown to be associated with higher rates of good clinical outcomes in patients with acute ischemic stroke. Here, we investigate clinical and radiographic factors associated with FPE in a large U.S. post-marketing registry (TRACK, Trevo Stent-Retriever Acute Stroke). Methods: We analyzed the TRACK database (multicenter registry of 634 patients from 23 centers from March 2013 through August 2015), which 609 patients were included in the final analysis. FPE was defined as a single pass/use of device, TICI 2c/3 recanalization, and no use of rescue therapy. Analysis of individual patient data from TRACK were performed to analyze clinical and radiographic characteristics associated with FPE as well-compared clinical outcomes defined as modified Rankin Scale (mRS) score at 30 and 90 days from hospital discharge to the non-FPE group. Results: The rate of FPE in TRACK was 23% (140/609). There was no association between patient demographics and FPE, including age (p = 0.36), sex (p = 0.50), race (p = 0.50), location of occlusion (p = 0.26), baseline NIHSS (p = 0.62), or past medical history. There was no difference in the use of a balloon-guide catheter or general anesthesia (49 and 57% with FPE vs. 47 and 64%, p = 0.63 and p = 0.14, respectively). Clinical outcomes were significantly associated with FPE; 63 vs. 44% in non-FPE patients achieved mRS 0-2 at 90 days (p = 0.0004). Conclusion: Our study showed that achieving complete recanalization with a single thrombectomy pass using the Trevo device was highly beneficial. The most common clinical factors that are used to determine eligibility for endovascular therapy, such as NIHSS severity, location of occlusion or patient age were not predictive of the ability to achieve FPE.

3.
Stroke ; 50(9): 2455-2460, 2019 09.
Article in English | MEDLINE | ID: mdl-31318624

ABSTRACT

Background and Purpose- It remains unclear how experience influences outcomes after the advent of stent retriever technology. We studied the relationship between site experience and outcomes in the Trevo Acute Ischemic Stroke multicenter registry. Methods- The 24 sites that enrolled patients in the Trevo Acute Ischemic Stroke registry were trichotomized into low-volume (<2 cases/month), medium-volume (2-4 cases/month), and high-volume centers (>4 cases/month). Baseline features, imaging, and clinical outcomes were compared across the 3 volume strata. A multivariable analysis was performed to assess whether outcomes were influenced by site volumes. Results- A total of 624 patients were included and distributed as low- (n=188 patients, 30.1%), medium- (n=175, 28.1%), and high-volume (n=261, 41.8%) centers. There were no significant differences in terms of age (mean, 66±16 versus 67±14 versus 65±15; P=0.2), baseline National Institutes of Health Stroke Scale (mean, 17.6±6.5 versus 16.8±6.5 versus 17.6±6.9; P=0.43), or occlusion site across the 3 groups. Median (interquartile range) times from stroke onset to groin puncture were 266 (181.8-442.5), 239 (175-389), and 336.5 (221.3-466.5) minutes in low-, medium-, and high-volume centers, respectively (P=0.004). Higher efficiency and better outcomes were seen in higher volume sites as demonstrated by shorter procedural times (median, 97 versus 67 versus 69 minutes; P<0.001), higher balloon guide catheter use (40% versus 36% versus 59%; P≤0.0001), and higher rates of good outcome (90-day modified Rankin Scale [mRS], ≤2; 39% versus 50% versus 53.4%; P=0.02). There were no appreciable differences in symptomatic intracranial hemorrhage or 90-day mortality. After adjustments in the multivariable analysis, there were significantly higher chances of achieving a good outcome in high- versus low-volume (odds ratio, 1.67; 95% CI, 1.03-2.7; P=0.04) and medium- versus low-volume (odds ratio, 1.75; 95% CI, 1.1-2.9; P=0.03) centers, but there were no significant differences between high- and medium-volume centers (P=0.86). Conclusions- Stroke center volumes significantly influence efficiency and outcomes in mechanical thrombectomy.


Subject(s)
Brain Ischemia/mortality , Intracranial Hemorrhages/mortality , Stroke/mortality , Thrombectomy , Aged , Aged, 80 and over , Brain Ischemia/therapy , Female , Humans , Intracranial Hemorrhages/therapy , Ischemia/therapy , Male , Middle Aged , Registries , Stents/adverse effects , Stroke/therapy , Thrombectomy/adverse effects , Thrombectomy/methods , Treatment Outcome
4.
J Neurointerv Surg ; 11(9): 861-865, 2019 Sep.
Article in English | MEDLINE | ID: mdl-30712011

ABSTRACT

INTRODUCTION: The Solitaire stent retriever registry showed improved reperfusion, faster procedure times, and better outcome in acute stroke patients with large vessel occlusion treated with a balloon guide catheter (BGC) and Solitaire stent retriever compared with a conventional guide catheter. The goal of this study was to evaluate whether use of a BGC with the Trevo stent retriever improves outcomes compared with a conventional guide catheter. METHODS: The TRACK registry recruited 23 sites to submit demographic, clinical, and site adjudicated angiographic and outcome data on consecutive patients treated with the Trevo stent retriever. BGC use was at the discretion of the physician. RESULTS: 536 anterior circulation patients (of whom 279 (52.1%) had BGC placement) were included in this analysis. Baseline characteristics were notable for younger patients in the BGC group (65.4±15.3 vs 68.1±13.6, P=0.03) and lower rate of hypertension (72% vs 79%, P=0.06). Mean time from symptom onset to groin puncture was longer in the BGC group (357 vs 319 min, P=0.06).Thrombolysis in Cerebral Infarction 2b/3 scores were higher in the BGC cohort (84% vs 75.5%, P=0.01). There was no difference in reperfusion time, first pass effect, number of passes, or rescue therapy. Good clinical outcome at 3 months was superior in patients with BGC (57% vs 40%; P=0.0004) with a lower mortality rate (13% vs 23%, P=0.008). Multivariate analysis demonstrated that BGC use was an independent predictor of good clinical outcome (OR 2; 95% CI 1.3 to 3.1, P=0.001). CONCLUSIONS: In acute stroke patients presenting with anterior circulation large vessel occlusion, use of a BGC with the Trevo stent retriever resulted in improved reperfusion, improved clinical outcome, and lower mortality.


Subject(s)
Catheterization/methods , Reperfusion/methods , Stroke/surgery , Thrombectomy/methods , Aged , Aged, 80 and over , Catheterization/instrumentation , Cohort Studies , Female , Humans , Male , Middle Aged , Registries , Reperfusion/instrumentation , Retrospective Studies , Stroke/diagnostic imaging , Thrombectomy/instrumentation , Treatment Outcome
5.
J Neurointerv Surg ; 10(6): 516-524, 2018 Jun.
Article in English | MEDLINE | ID: mdl-28963367

ABSTRACT

BACKGROUND: Recent randomized clinical trials (RCTs) demonstrated the efficacy of mechanical thrombectomy using stent-retrievers in patients with acute ischemic stroke (AIS) with large vessel occlusions; however, it remains unclear if these results translate to a real-world setting. The TREVO Stent-Retriever Acute Stroke (TRACK) multicenter Registry aimed to evaluate the use of the Trevo device in everyday clinical practice. METHODS: Twenty-three centers enrolled consecutive AIS patients treated from March 2013 through August 2015 with the Trevo device. The primary outcome was defined as achieving a Thrombolysis in Cerebral Infarction (TICI) score of ≥2b. Secondary outcomes included 90-day modified Rankin Scale (mRS), mortality, and symptomatic intracranial hemorrhage (sICH). RESULTS: A total of 634patients were included. Mean age was 66.1±14.8 years and mean baseline NIH Stroke Scale (NIHSS) score was 17.4±6.7; 86.7% had an anterior circulation occlusion. Mean time from symptom onset to puncture and time to revascularization were 363.1±264.5 min and 78.8±49.6 min, respectively. 80.3% achieved TICI ≥2b. 90-day mRS ≤2 was achieved in 47.9%, compared with 51.4% when restricting the analysis to the anterior circulation and within 6 hours (similar to recent AHA/ASA guidelines), and 54.3% for those who achieved complete revascularization. The 90-day mortality rate was 19.8%. Independent predictors of clinical outcome included age, baseline NIHSS, use of balloon guide catheter, revascularization, and sICH. CONCLUSION: The TRACK Registry results demonstrate the generalizability of the recent thrombectomy RCTs in real-world clinical practice. No differences in clinical and angiographic outcomes were shown between patients treated within the AHA/ASA guidelines and those treated outside the recommendations.


Subject(s)
Brain Ischemia/surgery , Cerebrovascular Disorders/surgery , Registries , Stents , Stroke/surgery , Thrombectomy/methods , Aged , Aged, 80 and over , Brain Ischemia/diagnostic imaging , Cerebrovascular Disorders/diagnostic imaging , Female , Humans , Male , Middle Aged , Prospective Studies , Retrospective Studies , Stroke/diagnostic imaging , Thrombectomy/instrumentation , Treatment Outcome