Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 3 de 3
1.
J Agric Food Chem ; 2024 Jun 18.
Article En | MEDLINE | ID: mdl-38888424

Beyond the key bitter compound kaempferol 3-O-(2‴-O-sinapoyl-ß-d-sophoroside) previously described in the literature (1), eight further bitter and astringent-tasting kaempferol glucosides (2-9) have been identified in rapeseed protein isolates (Brassica napus L.). The bitterness and astringency of these taste-active substances have been described with taste threshold concentrations ranging from 3.3 to 531.7 and 0.3 to 66.4 µmol/L, respectively, as determined by human sensory experiments. In this study, the impact of 1 and kaempferol 3-O-ß-d-glucopyranoside (8) on TAS2R-linked proton secretion by HGT-1 cells was analyzed by quantification of the intracellular proton index. mRNA levels of bitter receptors TAS2R3, 4, 5, 13, 30, 31, 39, 40, 43, 45, 46, 50 and TAS2R8 were increased after treatment with compounds 1 and 8. Using quantitative UHPLC-MS/MSMRM measurements, the concentrations of 1-9 were determined in rapeseed/canola seeds and their corresponding protein isolates. Depending on the sample material, compounds 1, 3, and 5-9 exceeded dose over threshold (DoT) factors above one for both bitterness and astringency in selected protein isolates. In addition, an increase in the key bitter compound 1 during industrial protein production (apart from enrichment) was observed, allowing the identification of the potential precursor of 1 to be kaempferol 3-O-(2‴-O-sinapoyl-ß-d-sophoroside)-7-O-ß-d-glucopyranoside (3). These results may contribute to the production of less bitter and astringent rapeseed protein isolates through the optimization of breeding and postharvest downstream processing.

2.
Curr Dev Nutr ; 8(Suppl 1): 102027, 2024 Feb.
Article En | MEDLINE | ID: mdl-38476725

Populations in low- and middle-income countries (LMIC) typically consume less than the recommended daily amount of protein. Alternative protein (AP) sources could help combat malnutrition, but this requires careful consideration of elements needed to further establish AP products in LMIC. Key considerations include technological, nutritional, safety, social, and economic challenges. This perspective analyzes these considerations in achieving dietary diversity in LMIC, using a combination of traditional and novel protein sources with high nutritional value, namely, soy, mycoprotein, and cultivated meat. Technological approaches to modulate the technofunctionality and bitter off-tastes of plant-sourced proteins facilitate processing and ensure consumer acceptance. Economic considerations for inputs, infrastructure for production, and transportation represent key elements to scale up AP. Dietary diversification is indispensable and LMIC cannot rely on plant proteins alone to provide adequate protein intake sustainably. Investments in infrastructure and innovation are urgently needed to offer diverse sources of protein in LMIC.

3.
Clin Mass Spectrom ; 16: 1-10, 2020 Apr.
Article En | MEDLINE | ID: mdl-34820514

The accurate measurement of androstenedione in human serum and plasma is required for steroid profiling to assure the appropriate diagnosis and differential diagnosis of hyperandrogenism. In this work, we introduce an isotope dilution liquid chromatography-tandem mass spectrometry (LC-MS/MS) candidate reference measurement procedure for the quantification of androstenedione in human serum and plasma. The performance of the procedure enables its use in the evaluation and standardization of routine assays and for the evaluation of patient samples to ensure the traceability of individual patient results. As the primary standard, a certified reference material from NMIA (National Measurement Institute, Australia) was used. Additionally, a quantitative nuclear magnetic resonance (qNMR) method was developed for the value assignment of the primary reference material, which ensures the direct traceability to SI units, as well as the independence from the availability of reference materials. 13C3-labeled androstenedione was used as the internal standard. The introduced method allows the measurement of androstenedione in the range of 0.05-12 ng/mL, and the assay imprecision was found to be <2% between 5 and 12 ng/mL, 3.5% at 1.5 ng/mL, and 5.2% at 0.05 ng/mL, with an accuracy of 95-105% for the serum and 91-103% for the plasma matrix. The transferability to a second laboratory was validated by method comparison based on 112 patient samples. The comparison of the results obtained from the presented method and an LC-MS/MS routine assay, using 150 native patient samples, showed a good correlation with a bias of the routine method of ≤4.0%.

...