Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 109
Filter
1.
Invest Radiol ; 2024 Aug 02.
Article in English | MEDLINE | ID: mdl-39088264

ABSTRACT

ABSTRACT: Photon-counting detectors (PCDs) have emerged as one of the most influential technical developments for medical imaging in recent memory. Surpassing conventional systems with energy-integrating detector technology in many aspects, PCD-CT scanners provide superior spatial resolution and dose efficiency for all radiological subspecialities. Demanding detailed display of trabecular microarchitecture and extensive anatomical coverage frequently within the same scan, musculoskeletal (MSK) imaging in particular can be a beneficiary of PCD-CT's remarkable performance. Since PCD-CT provides users with a plethora of customization options for both image acquisition and reconstruction, however, MSK radiologists need to be familiar with the scanner to unlock its full potential. From filter-based spectral shaping for artifact reduction over full field-of-view ultra-high-resolution scans to postprocessing of single- or dual-source multienergy data, almost every imaging task can be met with an optimized approach in PCD-CT. The objectives of this review were to give an overview of the most promising applications of PCD-CT in MSK imaging to date, to state current limitations, and to highlight directions for future research and developments.

2.
Acad Radiol ; 2024 Aug 06.
Article in English | MEDLINE | ID: mdl-39112296

ABSTRACT

BACKGROUND AND AIMS: The aim of this study was to investigate the imaging performance and quality differences of PCD-CT in standard resolution mode (SR) versus ultra-high resolution mode (UHR) in the lower extremity runoff of dose-matched CTAs in a human cadaveric model. METHODS: Extracorporeal perfusion of the upper leg was established in one fresh-frozen human cadaver via inguinal and popliteal accesses using a peristaltic pump. Seven peripheral stents were deployed in the SFA. Photon-counting CTAs were performed under contrast perfusion in SR and UHR mode with dose-equivalent 120kVp acquisition protocols (low-/ medium-/ high-dose: CTDIVol=3, 5, 10 mGy) and reconstructed with four vascular convolution kernels. Lumen visibility and contrast-to-noise ratio were compared using analyses of variance. Subjective image quality was assessed using a pairwise, forced-choice comparison software. RESULTS: Lumen visibility was equal for SR and UHR at the used dose levels. CNR increase by UHR was significant for (ultra-)sharp convolution kernels BV60 (3 mGy; UHR vs. SR, 19.9 ± 1.9 vs. 15.7 ± 1.6, p < 0.046) and BV76 (8.0 ± 0.6 vs. 5.4 ± 0.3, p < 0.001). The relative CNR increase was higher for low-dose than high-dose scans (BV76: 48% vs. 36% at high dose, p < 0.033). The CNR of the low-dose scan in UHR mode was comparable to the high-dose scan in SR mode when the ultra-sharp kernel was used (8.0 ± 0.6 vs. 9.1 ± 1.1, p > 0.760). Among UHR examinations, a significant increase in CNR could only be measured in BV76 (8.0 ± 0.6 (3 mGy) vs. 12.4 ± 0.9 (10 mGy), p < 0.001). Readers preferred subjective image quality of UHR for all kernels with BV76 being ranked highest. CONCLUSION: The CNR increase in UHR mode is highest when combining low radiation dose and ultra-sharp reconstructions. Meanwhile, the subjective image quality in UHR mode generally supersedes SR images, suggesting further dose reduction potential.

3.
Arch Gynecol Obstet ; 2024 Aug 01.
Article in English | MEDLINE | ID: mdl-39090472

ABSTRACT

PURPOSE: This study aims to investigate the psychological distress experienced by patients with an initial diagnosis of abnormal Pap smears or dysplastic changes of the cervix uteri. It investigated whether patients' age, education, information level and approach to information acquisition have an impact on their psychological distress. METHODS: A total of 364 female patients, aged 20-80 years, referred to the special dysplasia consultation hour at the Department of Obstetrics and Gynecology, Wuerzburg, completed a questionnaire containing validated items to assess information level, information acquisition, information needs and psychological distress, including a distress thermometer. Data from questionnaires and medical reports were used for analysis. RESULTS: The study found that 56.9% of patients experienced psychological distress before their first visit. Patients under 44 years of age, especially those with concerns about fertility and sexuality, and those with lower levels of education showed higher levels of distress (p-value = 0.018 and p-value = 0.037). 40.9% of patients felt poorly informed and 53.7% of patients wanted more information before their visit. Correlational analysis showed that the method of obtaining information correlated with the desire for more information (p-value < 0.001). Those who received information via the Internet felt less informed, wanted more information and experienced more anxiety. CONCLUSION: These findings highlight the need for improved patient education strategies and effective doctor-patient communication to address the knowledge gap and reduce patient distress. In addition, healthcare providers should ensure that patients have access to reliable online resources for accurate information.

4.
Acad Radiol ; 2024 Jul 04.
Article in English | MEDLINE | ID: mdl-38969575

ABSTRACT

RATIONALE AND OBJECTIVES: To assess image quality and radiation dose of ultra-high-pitch CT pulmonary angiography (CTPA) with free-breathing technique for diagnosis of pulmonary embolism using a photon-counting detector (PCD) CT compared to matched energy-integrating detector (EID)-based single-energy CTPA. MATERIALS AND METHODS: Fifty-one PCD-CTPAs were prospectively compared to 51 CTPAs on a third-generation dual-source EID-CT. CTPAs were acquired with an ultra-high-pitch protocol with free-breathing technique (40 mL contrast medium, pitch 3.2) at 140 kV (PCD) and 70-100 kV (EID). Iodine maps were reconstructed from spectral PCD-CTPAs. Image quality of CTPAs and iodine maps was assessed independently by three radiologists. Additionally, CT attenuation numbers within pulmonary arteries as well as signal-to-noise and contrast-to-noise ratios (SNR, CNR) were compared. Administered radiation dose was compared. RESULTS: CT attenuation was higher in the PCD-group (all P < 0.05). CNR and SNR were higher in lobar pulmonary arteries in PCD-CTPAs (P < 0.05), whereas no difference was ascertained within the pulmonary trunk (P > 0.05). Image quality of PCD-CTPA was rated best by all readers (excellent/good image quality in 96.1% of PCD-CTPAs vs. 50.9% of EID-CTPAs). PCD-CT produced no non-diagnostic scans vs. three non-diagnostic (5.9%) EID-CTPAs. Radiation dose was lower with PCD-CT than with EID-CT (effective dose 1.33 ± 0.47 vs. 1.80 ± 0.82 mSv; all P < 0.05). CONCLUSION: Ultra-high-pitch CTPA with free-breathing technique with PCD-CT allows for superior image quality with significantly reduced radiation dose and full spectral information. With the ultra-high pitch, only PCD-CTPA enables reconstruction of iodine maps containing additional functional information.

5.
Radiology ; 312(1): e232453, 2024 Jul.
Article in English | MEDLINE | ID: mdl-39078296

ABSTRACT

Background Contrast-unenhanced abdominal CT is the imaging standard for urinary calculi detection; however, studies comparing photon-counting detector (PCD) CT and energy-integrating detector (EID) CT dose-reduction potentials are lacking. Purpose To compare the radiation dose and image quality of optimized EID CT with those of an experimental PCD CT scan protocol including tin prefiltration in patients suspected of having urinary calculi. Materials and Methods This retrospective single-center study included patients who underwent unenhanced abdominal PCD CT or EID CT for suspected urinary caliculi between February 2022 and March 2023. Signal and noise measurements were performed at three anatomic levels (kidney, psoas, and obturator muscle). Nephrolithiasis and/or urolithiasis presence was independently assessed by three radiologists, and diagnostic confidence was recorded on a five-point scale (1, little to no confidence; 5, complete confidence). Reader agreement was determined by calculating Krippendorff α. Results A total of 507 patients (mean age, 51.7 years ± 17.4 [SD]; 317 male patients) were included (PCD CT group, 229 patients; EID CT group, 278 patients). Readers 1, 2, and 3 detected nephrolithiasis in 129, 127, and 129 patients and 94, 94, and 94 patients, whereas the readers detected urolithiasis in 113, 114, and 114 patients and 152, 153, and 152 patients in the PCD CT and EID CT groups, respectively. Regardless of protocol (PCD CT or EID CT) or calculus localization, near perfect interreader agreement was found (α ≥ 0.99; 95% CI: 0.99, 1). There was no evidence of a difference in reader confidence between PCD CT and EID CT (median confidence, 5; IQR, 5-5; P ≥ .57). The effective doses were 0.79 mSv (IQR, 0.63-0.99 mSv) and 1.39 mSv (IQR, 1.01-1.87 mSv) for PCD CT and EID CT, respectively. Despite the lower radiation exposure, the signal-to-noise ratios at the kidney, psoas, and obturator levels were 30%, 23%, and 17% higher, respectively, in the PCD CT group (P < .001). Conclusion Submillisievert abdominal PCD CT provided high-quality images for the diagnosis of urinary calculi; radiation exposure was reduced by 44% with a higher signal-to-noise ratio than with EID CT and with no evidence of a difference in reader confidence. Published under a CC BY 4.0 license. Supplemental material is available for this article. See also the editorial by Nezami and Malayeri in this issue.


Subject(s)
Tomography, X-Ray Computed , Urinary Calculi , Humans , Male , Female , Middle Aged , Tomography, X-Ray Computed/methods , Retrospective Studies , Urinary Calculi/diagnostic imaging , Radiation Dosage , Adult , Photons , Radiography, Abdominal/methods , Aged
7.
Otol Neurotol ; 45(6): 662-670, 2024 Jul 01.
Article in English | MEDLINE | ID: mdl-38865722

ABSTRACT

INTRODUCTION: Cochlear duct length (CDL) measurement plays a role in the context of individualized cochlear implant (CI) surgery regarding an individualized selection and implantation of the CI electrode carrier and an efficient postoperative anatomy-based fitting process. The level of detail of the preoperative temporal bone CT scan depends on the imaging modality with major impact on CDL measurements and CI electrode contact position determination. The aim of this study was to evaluate the accuracy of perioperative CDL measurements and electrode contact determination in photon-counting CT (PCCT). METHODS: Ten human fresh-frozen petrous bone specimens were examined with a first-generation PCCT. A clinically applicable radiation dose of 27.1 mGy was used. Scans were acquired before and after CI insertion. Postoperative measurement of the CDL was conducted using an otological planning software and 3D-curved multiplanar reconstruction. Investigation of electrode contact position was performed by two respective observers. Measurements were compared with a conventional multislice CT and to a high-resolution flat-panel volume CT with secondary reconstructions. RESULTS: Pre- and postoperative CDL measurements in PCCT images showed no significant difference to high-resolution flat-panel volume CT. Postoperative CI electrode contact determination was also as precise as the flat-panel CT-based assessment. PCCT and flat-panel volume CT were equivalent concerning interobserver variability. CONCLUSION: CDL measurement with PCCT was equivalent to flat-panel volume CT with secondary reconstructions. PCCT enabled highly precise postoperative CI electrode contact determination with substantial advantages over conventional multislice CT scanners.


Subject(s)
Cochlear Implantation , Humans , Cochlear Implantation/methods , Cochlear Duct/diagnostic imaging , Cochlear Duct/surgery , Tomography, X-Ray Computed/methods , Cochlear Implants , Photons , Petrous Bone/diagnostic imaging , Petrous Bone/surgery , Multidetector Computed Tomography/methods , Angiography/methods
8.
Korean J Radiol ; 25(7): 662-672, 2024 07.
Article in English | MEDLINE | ID: mdl-38942460

ABSTRACT

Since the emergence of the first photon-counting computed tomography (PCCT) system in late 2021, its advantages and a wide range of applications in all fields of radiology have been demonstrated. Compared to standard energy-integrating detector-CT, PCCT allows for superior geometric dose efficiency in every examination. While this aspect by itself is groundbreaking, the advantages do not stop there. PCCT facilitates an unprecedented combination of ultra-high-resolution imaging without dose penalty or field-of-view restrictions, detector-based elimination of electronic noise, and ubiquitous multi-energy spectral information. Considering the high demands of orthopedic imaging for the visualization of minuscule details while simultaneously covering large portions of skeletal and soft tissue anatomy, no subspecialty may benefit more from this novel detector technology than musculoskeletal radiology. Deeply rooted in experimental and clinical research, this review article aims to provide an introduction to the cosmos of PCCT, explain its technical basics, and highlight the most promising applications for patient care, while also mentioning current limitations that need to be overcome.


Subject(s)
Photons , Tomography, X-Ray Computed , Humans , Tomography, X-Ray Computed/methods , Musculoskeletal Diseases/diagnostic imaging , Musculoskeletal System/diagnostic imaging , Radiation Dosage
9.
Invest Radiol ; 2024 May 07.
Article in English | MEDLINE | ID: mdl-38709665

ABSTRACT

RATIONALE AND OBJECTIVES: This study investigates the performance of tomosynthesis in the presence of osteosynthetic implants, aiming to overcome superimposition-induced limitations in conventional radiograms. MATERIALS AND METHODS: After surgical fracture induction and subsequent osteosynthesis, 8 cadaveric fracture models (wrist, metacarpus, ankle, metatarsus) were scanned with the prototypical tomosynthesis mode of a multiuse x-ray system. Tomosynthesis protocols at 60, 80, and 116 kV (sweep angle 10°, 13 FPS) were compared with standard radiograms. Five radiologists independently rated diagnostic assessability based on an equidistant 7-point scale focusing on fracture delineation, intra-articular screw placement, and implant positioning. The intraclass correlation coefficient (ICC) was calculated to analyze interrater agreement. RESULTS: Radiation dose in radiography was 0.48 ± 0.26 dGy·cm2 versus 0.12 ± 0.01, 0.36 ± 0.02, and 1.95 ± 0.11 dGy·cm2 for tomosynthesis scans at 60, 80, and 116 kV. Delineation of fracture lines was superior for 80/116 kV tomosynthesis compared with radiograms (P ≤ 0.003). Assessability of intra-articular screw placement was deemed favorable for all tomosynthesis protocols (P ≤ 0.004), whereas superiority for evaluation of implant positioning could not be ascertained (all P's ≥ 0.599). Diagnostic confidence was higher for 80/116 kV tomosynthesis versus radiograms and 60 kV tomosynthesis (P ≤ 0.002). Interrater agreement was good for fracture delineation (ICC, 0.803; 95% confidence interval [CI], 0.598-0.904), intra-articular screw placement (ICC, 0.802; 95% CI, 0.599-0.903), implant positioning (ICC, 0.855; 95% CI, 0.729-0.926), and diagnostic confidence (ICC, 0.842; 95% CI, 0.556-0.934). CONCLUSIONS: In the postoperative workup of extremity fractures, tomosynthesis allows for superior assessment of fracture lines and intra-articular screw positioning with greater diagnostic confidence at radiation doses comparable to conventional radiograms.

10.
Sci Rep ; 14(1): 9358, 2024 04 23.
Article in English | MEDLINE | ID: mdl-38653758

ABSTRACT

The goal of this experimental study was to quantify the influence of helical pitch and gantry rotation time on image quality and file size in ultrahigh-resolution photon-counting CT (UHR-PCCT). Cervical and lumbar spine, pelvis, and upper legs of two fresh-frozen cadaveric specimens were subjected to nine dose-matched UHR-PCCT scan protocols employing a collimation of 120 × 0.2 mm with varying pitch (0.3/1.0/1.2) and rotation time (0.25/0.5/1.0 s). Image quality was analyzed independently by five radiologists and further substantiated by placing normed regions of interest to record mean signal attenuation and noise. Effective mAs, CT dose index (CTDIvol), size-specific dose estimate (SSDE), scan duration, and raw data file size were compared. Regardless of anatomical region, no significant difference was ascertained for CTDIvol (p ≥ 0.204) and SSDE (p ≥ 0.240) among protocols. While exam duration differed substantially (all p ≤ 0.016), the lowest scan time was recorded for high-pitch protocols (4.3 ± 1.0 s) and the highest for low-pitch protocols (43.6 ± 15.4 s). The combination of high helical pitch and short gantry rotation times produced the lowest perceived image quality (intraclass correlation coefficient 0.866; 95% confidence interval 0.807-0.910; p < 0.001) and highest noise. Raw data size increased with acquisition time (15.4 ± 5.0 to 235.0 ± 83.5 GByte; p ≤ 0.013). Rotation time and pitch factor have considerable influence on image quality in UHR-PCCT and must therefore be chosen deliberately for different musculoskeletal imaging tasks. In examinations with long acquisition times, raw data size increases considerably, consequently limiting clinical applicability for larger scan volumes.


Subject(s)
Photons , Humans , Tomography, X-Ray Computed/methods , Cadaver , Rotation , Radiation Dosage , Tomography, Spiral Computed/methods
11.
Magn Reson Imaging ; 112: 27-37, 2024 Oct.
Article in English | MEDLINE | ID: mdl-38599503

ABSTRACT

BACKGROUND AND PURPOSE: Long acquisition times limit the feasibility of established non-contrast-enhanced MRA (non-CE-MRA) techniques. The purpose of this study was to evaluate a highly accelerated flow-independent sequence (Relaxation-Enhanced Angiography without Contrast and Triggering [REACT]) for imaging of the extracranial arteries in acute ischemic stroke (AIS). MATERIALS AND METHODS: Compressed SENSE (CS) accelerated (factor 7) 3D isotropic REACT (fixed scan time: 01:22 min, reconstructed voxel size 0.625 × 0.625 × 0.75 mm3) and CE-MRA (CS factor 6, scan time: 1:08 min, reconstructed voxel size 0.5 mm3) were acquired in 76 AIS patients (69.4 ± 14.3 years, 33 females) at 3 Tesla. Two radiologists assessed scans for the presence of internal carotid artery (ICA) stenosis and stated their diagnostic confidence using a 5-point scale (5 = excellent). Vessel quality of cervical arteries as well as the impact of artifacts and image noise were scored on 5-point scales (5 = excellent/none). Apparent signal- and contrast-to-noise ratios (aSNR/aCNR) were measured for the common carotid artery (CCA) and ICA (C1-segment). RESULTS: REACT provided a sensitivity of 88.5% and specificity of 100% for clinically relevant (≥50%) ICA stenosis with substantial concordance to CE-MRA regarding stenosis grading (Cohen's kappa 0.778) and similar diagnostic confidence (REACT: mean 4.5 ± 0.4 vs. CE-MRA: 4.5 ± 0.6; P = 0.674). Presence of artifacts (3.6 ± 0.5 vs. 3.5 ± 0.7; P = 0.985) and vessel quality (all segments: 3.6 ± 0.7 vs. 3.8 ± 0.7; P = 0.004) were comparable between both techniques with REACT showing higher scores at the CCA (4.3 ± 0.6 vs. 3.8 ± 0.9; P < 0.001) and CE-MRA at V2- (3.3 ± 0.5 vs. 3.9 ± 0.8; P < 0.001) and V3-segments (3.3 ± 0.5 vs. 4.0 ± 0.8; P < 0.001). For all vessels, REACT showed a lower impact of image noise (3.8 ± 0.6 vs. 3.6 ± 0.7; P = 0.024) while yielding higher aSNR (52.5 ± 15.1 vs. 37.9 ± 12.5; P < 0.001) and aCNR (49.4 ± 15.0 vs. 34.7 ± 12.3; P < 0.001) for all vessels combined. CONCLUSIONS: In patients with acute ischemic stroke, highly accelerated REACT provides an accurate detection of ICA stenosis with vessel quality and scan time comparable to CE-MRA.


Subject(s)
Ischemic Stroke , Magnetic Resonance Angiography , Humans , Female , Male , Magnetic Resonance Angiography/methods , Aged , Ischemic Stroke/diagnostic imaging , Middle Aged , Neck/diagnostic imaging , Neck/blood supply , Contrast Media , Aged, 80 and over , Signal-To-Noise Ratio , Image Processing, Computer-Assisted/methods , Artifacts , Imaging, Three-Dimensional/methods , Reproducibility of Results , Image Enhancement/methods , Image Interpretation, Computer-Assisted/methods
12.
Acad Radiol ; 2024 Mar 05.
Article in English | MEDLINE | ID: mdl-38448327

ABSTRACT

RATIONALE AND OBJECTIVES: Aiming to offset image quality limitations in radiographs due to superimposition, this study investigates the diagnostic potential of appendicular skeleton tomosynthesis. MATERIALS AND METHODS: Eight cadaveric extremities (four hands and feet) were examined employing the prototypical tomosynthesis mode of a twin robotic X-ray scanner. 12 protocols with varying sweep angles (10, 20 vs. 40°), frame rates (13 vs. 26 fps), and tube voltages (60 vs. 80 kV) were compared to radiographs. Four radiologists separately evaluated cortical and trabecular bone visualization and fracture patterns. Interreader reliability was assessed based on the intraclass correlation coefficient (ICC). RESULTS: Radiation dose in radiography was 0.59 ± 0.20 dGy * cm2 versus 0.11 ± 0.00 to 2.46 ± 0.17 dGy * cm2 for tomosynthesis. Cortical bone display was inferior for radiographs compared to 40° and 20° tomosynthesis. Best results were ascertained for the 80 kV/40°/26 fps protocol. Trabecular bone depiction was also superior in tomosynthesis (p ≤ 0.009) and best with the 80 kV/10°/26 fps setting. Interreader reliability was moderate for cortical bone display (ICC 0.521, 95% confidence interval 0.356-0.641) and good for trabecular bone (0.759, 0.697-0.810). Diagnostic accuracy for articular involvement and multifragment situations was higher in tomosynthesis (93.8-100%/92.2-100%) vs. radiography (85.9%/82.8%.). Diagnostic confidence was also better in tomosynthesis (p ≤ 0.003). CONCLUSION: Compared to radiography, tomosynthesis allows for superior assessability of cortical and trabecular bone and fracture morphology, especially at high framerates. Operating on a multipurpose X-ray system, tomosynthesis of the appendicular skeleton can be performed without additional scanner hardware.

13.
Cancers (Basel) ; 16(6)2024 Mar 20.
Article in English | MEDLINE | ID: mdl-38539562

ABSTRACT

This study investigated whether virtual monoenergetic images (VMIs) and iodine mapping based on dual-energy CT (DECT) provide advantages in the assessment of endometrial cancer. A dual-source DECT was performed for primary staging of histologically proven endometrioid adenocarcinoma in 21 women (66.8 ± 12.0 years). In addition to iodine maps, VMIs at 40, 50, 60, 70, and 80 keV were reconstructed from polyenergetic images (PEIs). Objective analysis comprised the measurement of tumor contrast, contrast-to-noise ratio, and normalized iodine concentration (NIC). In addition, three radiologists independently rated tumor conspicuity. The highest tumor contrast (106.6 ± 45.0 HU) and contrast-to-noise ratio (4.4 ± 2.0) was established for VMIs at 40 keV. Tumor contrast in all VMIs ≤ 60 keV was higher than in PEIs (p < 0.001). The NIC of malignant tissue measured in iodine maps was substantially lower compared with a healthy myometrium (0.3 ± 0.1 versus 0.6 ± 0.1 mg/mL; p < 0.001). Tumor conspicuity was highest in 40 keV datasets, whereas no difference was found among PEIs and VMIs at 60 and 70 keV (p ≥ 0.334). Interobserver agreement was good, indicated by an intraclass correlation coefficient of 0.824 (0.772-0.876; p < 0.001). In conclusion, computation of VMIs at 40 keV and color-coded iodine maps aids the assessment of endometroid adenocarcinoma in primary staging.

14.
Rofo ; 2024 Mar 13.
Article in English | MEDLINE | ID: mdl-38479409

ABSTRACT

PURPOSE: Due to the increasing number of COVID-19 infections since spring 2020 the patient care workflow underwent changes in Germany. To minimize face-to-face exposure and reduce infection risk, non-time-critical elective medical procedures were postponed. Since ultrasound examinations include non-time-critical elective examinations and often can be substituted by other imaging modalities not requiring direct patient contact, the number of examinations has declined significantly. The aim of this study is to quantify the baseline number of ultrasound examinations in the years before, during, and in the early post-pandemic period of the COVID-19 pandemic (since January 2015 to September 2023), and to measure the number of examinations at different German university hospitals. MATERIALS AND METHODS: The number of examinations was assessed based on a web-based database at all participating clinics at the indicated time points. RESULTS: N = 288 562 sonographic examinations from four sites were included in the present investigation. From January 2020 to June 2020, a significantly lower number of examinations of n = 591.21 vs. 698.43 (p = 0.01) per month and included center was performed. Also, excluding the initial pandemic period until June 2020, significantly fewer ultrasound examinations were performed compared to pre-pandemic years 648.1 vs. 698.4 (p < 0.05), per month and included center, while here differences between the individual centers were observed. In the late phase of the pandemic (n = 681.96) and in the post-pandemic phase (as defined by the WHO criteria from May 2023; n = 739.95), the number of sonographic examinations returned to pre-pandemic levels. CONCLUSION: The decline in the number of sonographic examinations caused by the COVID-19 pandemic was initially largely intentional and can be illustrated quantitatively. After an initial abrupt decline in sonographic examinations, the pre-pandemic levels could not be reached for a long time, which could be due to restructuring of patient care and follow-up treatment. In the post-pandemic phase, the pre-pandemic level has been achieved again. The reasons for a prolonged reduction in ultrasound examinations are discussed in this article. KEY POINTS: · During the pandemic, significantly fewer ultrasound examinations were performed in the included centers.. · The number of examinations could not be reach the pre-pandemic level for a long time, which could be due to restructuring of patient care and follow-up treatment.. · Identifying causes for sonographic exam reduction is crucial in pandemic preparedness to uphold healthcare quality and continuity for all patients.. · The prolonged decline in sonographic examinations during the pandemic does not represent a lasting trend, as evidenced by the return to pre-pandemic levels..

15.
Eur J Radiol Open ; 12: 100557, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38495213

ABSTRACT

Purpose: The objective of this study was to implement a 5-minute MRI protocol for the shoulder in routine clinical practice consisting of accelerated 2D turbo spin echo (TSE) sequences with deep learning (DL) reconstruction at 1.5 and 3 Tesla, and to compare the image quality and diagnostic performance to that of a standard 2D TSE protocol. Methods: Patients undergoing shoulder MRI between October 2020 and June 2021 were prospectively enrolled. Each patient underwent two MRI examinations: first a standard, fully sampled TSE (TSES) protocol reconstructed with a standard reconstruction followed by a second fast, prospectively undersampled TSE protocol with a conventional parallel imaging undersampling pattern reconstructed with a DL reconstruction (TSEDL). Image quality and visualization of anatomic structures as well as diagnostic performance with respect to shoulder lesions were assessed using a 5-point Likert-scale (5 = best). Interchangeability analysis, Wilcoxon signed-rank test and kappa statistics were performed to compare the two protocols. Results: A total of 30 participants was included (mean age 50±15 years; 15 men). Overall image quality was evaluated to be superior in TSEDL versus TSES (p<0.001). Noise and edge sharpness were evaluated to be significantly superior in TSEDL versus TSES (noise: p<0.001, edge sharpness: p<0.05). No difference was found concerning qualitative diagnostic confidence, assessability of anatomical structures (p>0.05), and quantitative diagnostic performance for shoulder lesions when comparing the two sequences. Conclusions: A fast 5-minute TSEDL MRI protocol of the shoulder is feasible in routine clinical practice at 1.5 and 3 T, with interchangeable results concerning the diagnostic performance, allowing a reduction in scan time of more than 50% compared to the standard TSES protocol.

16.
BMC Med Imaging ; 24(1): 49, 2024 Feb 23.
Article in English | MEDLINE | ID: mdl-38395772

ABSTRACT

PURPOSE: Unenhanced abdominal CT constitutes the diagnostic standard of care in suspected urolithiasis. Aiming to identify potential for radiation dose reduction in this frequent imaging task, this experimental study compares the effect of spectral shaping and tube voltage modulation on image quality. METHODS: Using a third-generation dual-source CT, eight cadaveric specimens were scanned with varying tube voltage settings with and without tin filter application (Sn 150, Sn 100, 120, 100, and 80 kVp) at three dose levels (3 mGy: standard; 1 mGy: low; 0.5 mGy: ultralow). Image quality was assessed quantitatively by calculation of signal-to-noise ratios (SNR) for various tissues (spleen, kidney, trabecular bone, fat) and subjectively by three independent radiologists based on a seven-point rating scale (7 = excellent; 1 = very poor). RESULTS: Irrespective of dose level, Sn 100 kVp resulted in the highest SNR of all tube voltage settings. In direct comparison to Sn 150 kVp, superior SNR was ascertained for spleen (p ≤ 0.004) and kidney tissue (p ≤ 0.009). In ultralow-dose scans, subjective image quality of Sn 100 kVp (median score 3; interquartile range 3-3) was higher compared with conventional imaging at 120 kVp (2; 2-2), 100 kVp (1; 1-2), and 80 kVp (1; 1-1) (all p < 0.001). Indicated by an intraclass correlation coefficient of 0.945 (95% confidence interval: 0.927-0.960), interrater reliability was excellent. CONCLUSIONS: In abdominal CT with maximised dose reduction, tin prefiltration at 100 kVp allows for superior image quality over Sn 150 kVp and conventional imaging without spectral shaping.


Subject(s)
Tin , Tomography, X-Ray Computed , Humans , Reproducibility of Results , Radiation Dosage , Tomography, X-Ray Computed/methods , Abdomen/diagnostic imaging
17.
Sci Rep ; 14(1): 4724, 2024 02 27.
Article in English | MEDLINE | ID: mdl-38413684

ABSTRACT

Photon-counting detector (PCD)-CT allows for reconstruction of virtual non-iodine (VNI) images from contrast-enhanced datasets. This study assesses the diagnostic performance of aortic valve calcification scoring (AVCS) derived from VNI datasets generated with a 1st generation clinical dual-source PCD-CT. AVCS was evaluated in 123 patients (statistical analysis only comprising patients with aortic valve calcifications [n = 56; 63.2 ± 11.6 years]), who underwent contrast enhanced electrocardiogram-gated (either prospective or retrospective or both) cardiac CT on a clinical PCD system. Patient data was reconstructed at 70 keV employing a VNI reconstruction algorithm. True non-contrast (TNC) scans at 70 keV without quantum iterative reconstruction served as reference in all individuals. Subgroup analysis was performed in 17 patients who received both, prospectively and retrospectively gated contrast enhanced scans (n = 8 with aortic valve calcifications). VNI images with prospective/retrospective gating had an overall sensitivity of 69.2%/56.0%, specificity of 100%/100%, accuracy of 85.4%/81.0%, positive predictive value of 100%/100%, and a negative predictive value of 78.2%/75.0%. VNI images with retrospective gating achieved similar results. For both gating approaches, AVCSVNI showed high correlation (r = 0.983, P < 0.001 for prospective; r = 0.986, P < 0.001 for retrospective) with AVCSTNC. Subgroup analyses demonstrated excellent intra-individual correlation between different acquisition modes (r = 0.986, P < 0.001). Thus, VNI images derived from cardiac PCD-CT allow for excellent diagnostic performance in the assessment of AVCS, suggesting potential for the omission of true non-contrast scans in the clinical workup of patients with aortic calcifications.


Subject(s)
Aortic Valve Stenosis , Aortic Valve , Aortic Valve/pathology , Calcinosis , Iodine , Humans , Retrospective Studies , Aortic Valve/diagnostic imaging , Prospective Studies , Tomography, X-Ray Computed/methods , Angiography
18.
Acad Radiol ; 31(7): 2973-2986, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38403477

ABSTRACT

RATIONALE AND OBJECTIVES: This study aims to compare the diagnostic confidence of photon-counting detector CT angiography (PCD-CTA) depending on the used vascular reformatting kernels with digital subtraction angiography (DSA) as diagnostic reference standard in peripheral arterial occlusive disease (PAOD). MATERIAL AND METHODS: In 39 patients, 45 lower extremity PCD-CTA with subsequent DSA were analyzed. Advanced PAOD (Fontaine stage 4) was ascertained in 77.8% of patients. CTA post-processing comprised three vascular kernels (Bv36/48/56). Objective image quality assessment included vessel attenuation, image noise, contrast-to-noise (CNR) and signal-to-noise ratios (SNR). Subjective evaluation of calcium blooming, vessel sharpness, luminal attenuation and image noise was performed by three radiologists. Diagnostic performance and concordance to DSA were assessed. RESULTS: The luminal attenuation remained kernel-independent constant. With sharper kernels, image noise increased substantially, while SNR and CNR decreased. Subjective reduction of calcium blooming and increased vessel sharpness were noted for the sharp Bv56 kernel. While sensitivity in stenosis quantification was comparable between kernels (81.6% vs. 81.5% vs. 81.0%, p = 0.797), specificity increased slightly higher sharpness (71.1% vs. 76.9% vs. 79.6%, p = 0.067). Diagnostic concordance of stenosis ratings compared to DSA increased likewise (Bv36 vs. Bv56, p = 0.002). Severe crural vessel calcifications had no influence on sensitivity, regardless of kernel selection. Contrarily, specificity was substantially worse in severely calcified tibial vessels but could be improved by using the sharp Bv56 kernel (Bv36 vs. Bv56 p = 0.024). Diagnostic confidence was highest for Bv56. CONCLUSION: In lower leg PCD-CTA, sharp convolution kernels increase diagnostic confidence compared to DSA by improved vessel delineation and reduced calcium blooming with acceptable image noise.


Subject(s)
Angiography, Digital Subtraction , Computed Tomography Angiography , Peripheral Arterial Disease , Sensitivity and Specificity , Humans , Angiography, Digital Subtraction/methods , Female , Male , Peripheral Arterial Disease/diagnostic imaging , Aged , Computed Tomography Angiography/methods , Middle Aged , Aged, 80 and over , Signal-To-Noise Ratio , Radiographic Image Interpretation, Computer-Assisted/methods , Photons , Adult
19.
Invest Radiol ; 59(9): 629-634, 2024 Sep 01.
Article in English | MEDLINE | ID: mdl-38329822

ABSTRACT

OBJECTIVES: Image acquisition in ultra-high-resolution (UHR) scan mode does not impose a dose penalty in photon-counting CT (PCCT). This study aims to investigate the dose saving potential of using UHR instead of standard-resolution PCCT for lumbar spine imaging. MATERIALS AND METHODS: Eight cadaveric specimens were examined with 7 dose levels (5-35 mGy) each in UHR (120 × 0.2 mm) and standard-resolution acquisition mode (144 × 0.4 mm) on a first-generation PCCT scanner. The UHR images were reconstructed with 3 dedicated bone kernels (Br68 [spatial frequency at 10% of the modulation transfer function 14.5 line pairs/cm], Br76 [21.0], and Br84 [27.9]), standard-resolution images with Br68 and Br76. Using automatic segmentation, contrast-to-noise ratios (CNRs) were established for lumbar vertebrae and psoas muscle tissue. In addition, image quality was assessed subjectively by 19 independent readers (15 radiologists, 4 surgeons) using a browser-based forced choice comparison tool totaling 16,974 performed pairwise tests. Pearson's correlation coefficient ( r ) was used to analyze the relationship between CNR and subjective image quality rankings, and Kendall W was calculated to assess interrater agreement. RESULTS: Irrespective of radiation exposure level, CNR was higher in UHR datasets than in standard-resolution images postprocessed with the same reconstruction parameters. The use of sharper convolution kernels entailed lower CNR but higher subjective image quality depending on radiation dose. Subjective assessment revealed high interrater agreement ( W = 0.86; P < 0.001) with UHR images being preferred by readers in the majority of comparisons on each dose level. Substantial correlation was ascertained between CNR and the subjective image quality ranking (all r 's ≥ 0.95; P < 0.001). CONCLUSIONS: In PCCT of the lumbar spine, UHR mode's smaller pixel size facilitates a considerable CNR increase over standard-resolution imaging, which can either be used for dose reduction or higher spatial resolution depending on the selected convolution kernel.


Subject(s)
Cadaver , Lumbar Vertebrae , Photons , Radiation Dosage , Tomography, X-Ray Computed , Humans , Lumbar Vertebrae/diagnostic imaging , Tomography, X-Ray Computed/methods
20.
PLoS One ; 19(2): e0297800, 2024.
Article in English | MEDLINE | ID: mdl-38330071

ABSTRACT

PURPOSE: The aim of this study was to evaluate the usability of a recently developed extracorporeally-perfused cadaver model for training the angiographic management of acute arterial diseases and periprocedural complications that may occur during endovascular therapy of the lower extremity arterial runoff. MATERIALS AND METHODS: Continuous extracorporeal perfusion was established in three fresh-frozen body donors via inguinal and infragenicular access. Using digital subtraction angiography for guidance, both arterial embolization (e.g., embolization using coils, vascular plugs, particles, and liquid embolic agents) and endovascular recanalization procedures (e.g., manual aspiration or balloon-assisted embolectomy) as well as various embolism protection devices were tested. Furthermore, the management of complications during percutaneous transluminal angioplasty, such as vessel dissection and rupture, were exercised by implantation of endovascular dissection repair system or covered stents. Interventions were performed by two board-certified interventional radiologists and one resident with only limited angiographic experience. RESULTS: Stable extracorporeal perfusion was successfully established on both thighs of all three body donors. Digital subtraction angiography could be performed reliably and resulted in realistic artery depiction. The model allowed for repeatable training of endovascular recanalization and arterial embolization procedures with typical tactile feedback in a controlled environment. Furthermore, the handling of more complex angiographic devices could be exercised. Whereas procedural success was be ascertained for most endovascular interventions, thrombectomies procedures were not feasible in some cases due to the lack of inherent coagulation. CONCLUSION: The presented perfusion model is suitable for practicing time-critical endovascular interventions in the lower extremity runoff under realistic but controlled conditions.


Subject(s)
Endovascular Procedures , Vascular Diseases , Humans , Endovascular Procedures/methods , Arteries , Angioplasty/methods , Stents , Cadaver , Treatment Outcome , Retrospective Studies
SELECTION OF CITATIONS
SEARCH DETAIL