Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
World Neurosurg ; 2024 May 03.
Article in English | MEDLINE | ID: mdl-38705268

ABSTRACT

BACKGROUND: There are cases of superficial siderosis (SS) with spinal ventral fluid-filled collection in the spinal canal. In our previous study, the balanced steady-state free precession sequence magnetic resonance imaging is useful in identifying the location of dural defects. However, because of its narrow scan area and long scan time, it cannot easily detect the defect location in some patients with small dural defect. In this study, we applied 4-dimensional (4D) dynamic computed tomography (CT) imaging, including time-axis imaging, to myelography using the latest CT imaging equipment, which can perform short-time continuous imaging, to identify the dural defect site. METHODS: Twenty SS patients with ventral fluid-filled collection in the spinal canal (9 males, 11 females; mean age 61.6 years) underwent 4D dynamic CT myelography. A 192-row helical CT (SOMATOM Force, SIEMENS, Munich, Germany) with high-speed scanning capability was used to obtain 9-11 scans per minute at low dose while passing contrast medium into the subarachnoid space. Then, contrast leakage sites were identified. RESULTS: The contrast leakage sites could be identified in all 20 cases: C7/Th1, 2 cases; Th1/2, 5 cases; Th2/3, 9 cases; Th3/4, 1 case; Th5/6, 1 case; Th7/8, 1 case; and Th8/9, 1 case. Eighteen cases underwent surgical operation, and actual dural defects were confirmed at the contrast leakage sites. The mean ± standard deviation of leakage time from contrast agent injection was 19.0 ± 9.2 s. CONCLUSIONS: The 4D dynamic CT myelography can be used to reliably identify the location of spinal fluid leakage. In SS cases, dural defects could be visualized in an average of 19 seconds.

2.
Stud Health Technol Inform ; 302: 486-487, 2023 May 18.
Article in English | MEDLINE | ID: mdl-37203727

ABSTRACT

Excessive retakes of X-ray images increase labor and material costs, as well as result in excess radiation exposure for patients and a long waiting time. In this study, we evaluated the effectiveness of the token economy method as a management method for reducing X-ray retake rate among radiology technicians. The results showed a 2.5% reduction in retake rate, indicating the effectiveness of our method. In addition, we suggest that the token-economy-based approach can be applied to other hospital management problems.


Subject(s)
Token Economy , Humans , X-Rays , Radiography
4.
Am Heart J Plus ; 30: 100298, 2023 Jun.
Article in English | MEDLINE | ID: mdl-38510923

ABSTRACT

Background: Periodontal disease (PD) is associated with an increased risk of cardiovascular disease (CVD). Pericardial adipose tissue (PAT) is known as a marker of progressive CVD. This study sought to assess the association between PD and PAT in patients with CVD. Methods: We retrospectively investigated 135 patients admitted for CVD who underwent computed tomography coronary angiography (CTCA) and periodontal examinations. Periodontal assessment using the community periodontal index (CPI) was based on the probing pocket depth around teeth. Patients with CPI ≥3 were categorized as having PD. PAT volume was measured with a quantitative semi-automated procedure using CTCA images. Patients were divided into tertiles according to PAT volume. Baseline characteristics and PD findings were compared among the tertiles. Results: Eighty-six patients were diagnosed with PD (63.7 %). Mean PAT volume was 181.4 ml, and patients were categorized as small-PAT (PAT <148.9 ml), intermediate-PAT (148.9 ml ≤ PAT ≤204.6 ml), and large-PAT (PAT >204.6 ml). The prevalence of PD was significantly higher in large-PAT (38/46, 82.6 %) than in small-PAT (18/45, 40.0 %) and intermediate-PAT (30/44, 68.2 %) patients. Multivariate logistic regression analysis showed that body weight, history of hypertension, and the presence of PD were independent predictors for large-PAT (odds ratio [OR]: 1.12, P < 0.001, OR: 3.97, P = 0.017, and OR: 4.18, P = 0.0078, respectively). Conclusion: The presence and severity of PD were significantly correlated with PAT volume, which has been associated with progressive CVD. Further prospective studies are warranted to assess the impact of PD on the onset and outcomes of CVD.

5.
Tomography ; 8(2): 1079-1089, 2022 04 08.
Article in English | MEDLINE | ID: mdl-35448722

ABSTRACT

Routine CT examinations are crucial in colorectal cancer patients (CCPs); however, the high frequency of radiation exposure is a significant concern. This study investigated the radiation dose, image quality, and diagnostic performance of tin filter-based spectral shaping chest−abdominal−pelvic (CAP) CT for CCPs. We reviewed 44 CCPs who underwent single-phase enhanced tin-filtered 100 kV (TF100kV) and standard 120 kV (ST120kV) CAP CT on separate days. Radiation metrics including the volume CT dose index (CTDIvol), dose-length product (DLP), and effective dose (ED) were calculated for both protocols. Two radiologists assessed the presence of the following lesions: lung metastasis, liver metastasis, lymph node metastasis, peritoneal dissemination, and bone metastasis. The area under the receiver operating characteristic curve (AUC) was calculated for the diagnostic performance of each protocol. Radiation metrics of the TF100kV protocol were significantly lower than those of the ST120kV protocol (CDTIvol 1.60 ± 0.31 mGy vs. 14.4 ± 2.50, p < 0.0001; DLP 107.1 (95.9−125.5) mGy·cm vs. 996.7 (886.2−1144.3), p < 0.0001; ED 1.93 (1.73−2.26) mSv vs. 17.9 (16.0−20.6), p < 0.0001, respectively). TF100kV protocol achieved comparable diagnostic performance to that of the ST120kV protocol (AUC for lung metastasis: 1.00 vs. 0.94; liver metastasis: 0.88 vs. 0.83, respectively). TF100kV protocol could substantially reduce the radiation dose by 89% compared to that with the ST120kV protocol while maintaining good diagnostic performance in CCPs.


Subject(s)
Colorectal Neoplasms , Lung Neoplasms , Colorectal Neoplasms/diagnostic imaging , Drug Tapering , Humans , Lung Neoplasms/diagnostic imaging , Radiation Dosage , Tin , Tomography, X-Ray Computed/methods
SELECTION OF CITATIONS
SEARCH DETAIL
...