Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 14 de 14
Filter
4.
Cardiol Clin ; 42(3): 351-360, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38910020

ABSTRACT

Echocardiography, in all its forms (transthoracic echocardiography [TTE], transesophageal echocardiography [TEE], and intracardiac echocardiography [ICE]), is pivotal for the evaluation, guidance, and follow-up of transcatheter tricuspid edge-to-edge repair (TV-TEER) therapies. Although two-dimensional (2D) echocardiography remains essential, three-dimensional (3D) echo with multiplanar reconstruction (MPR) has revolutionized the field of structural imaging. In addition, the advent of 3D ICE has added an important modality to the imaging toolbox, particularly helpful when intraprocedural TEE images are challenging. In this review, we provide a detailed, step-by-step approach for advanced echocardiographic guidance of TV-TEER using 3D MPR.


Subject(s)
Cardiac Catheterization , Tricuspid Valve Insufficiency , Tricuspid Valve , Humans , Cardiac Catheterization/methods , Echocardiography/methods , Echocardiography, Three-Dimensional/methods , Echocardiography, Transesophageal/methods , Tricuspid Valve/diagnostic imaging , Tricuspid Valve/surgery , Tricuspid Valve Insufficiency/surgery , Tricuspid Valve Insufficiency/diagnostic imaging , Ultrasonography, Interventional/methods
5.
JTCVS Open ; 18: 12-30, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38690415

ABSTRACT

Objective: Anterior mitral anular calcification, particularly in radiation heart disease, and previous valve replacement with destroyed intervalvular fibrosa are challenging for prosthesis sizing and placement. The Commando procedure with intervalvular fibrosa reconstruction permits double-valve replacement in these challenging conditions. We referenced outcomes after Commando procedures to standard double-valve replacements. Methods: From January 2011 to January 2022, 129 Commando procedures and 1191 aortic and mitral double-valve replacements were performed at the Cleveland Clinic, excluding endocarditis. Reasons for the Commando were severe calcification after radiation (n = 67), without radiation (n = 43), and others (n = 19). Commando procedures were referenced to a subset of double-valve replacements using balancing-score methods (109 pairs). Results: Between balanced groups, Commando versus double-valve replacement had higher total calcium scores (median 6140 vs 2680 HU, P = .03). Hospital outcomes were similar, including operative mortality (12/11% vs 8/7.3%, P = .35) and reoperation for bleeding (9/8.3% vs 5/4.6%, P = .28). Survival and freedom from reoperation at 5 years were 54% versus 67% (P = .33) and 87% versus 100% (P = .04), respectively. Higher calcium score was associated with lower survival after double-valve replacement but not after the Commando. The Commando procedure had lower aortic valve mean gradients at 4 years (9.4 vs 11 mm Hg, P = .04). After Commando procedures for calcification, 5-year survival was 60% and 59% with and without radiation, respectively (P = .47). Conclusions: The Commando procedure with reconstruction of the intervalvular fibrosa destroyed by mitral anular calcification, radiation, or previous surgery demonstrates acceptable outcomes similar to standard double-valve replacement. More experience and long-term outcomes are required to refine patient selection for and application of the Commando approach.

6.
Open Heart ; 11(1)2024 May 20.
Article in English | MEDLINE | ID: mdl-38769066

ABSTRACT

OBJECTIVE: Patients with moderate aortic stenosis (AS) exhibit high morbidity and mortality. Limited evidence exists on the role of aortic valve replacement (AVR) in this patient population. To investigate the benefit of AVR in moderate AS on survival and left ventricular function. METHODS: In a retrospective cohort study, patients with moderate AS between 2008 and 2016 were selected from the Cleveland Clinic echocardiography database and followed until 2018. Patients were classified as receiving AVR or managed medically (clinical surveillance). All-cause and cardiovascular mortality were assessed by survival analyses. Temporal haemodynamic and structural changes were assessed with longitudinal analyses using linear mixed effects models. RESULTS: We included 1421 patients (mean age, 75.3±5.4 years and 39.9% women) followed over a median duration of 6 years. Patients in the AVR group had lower risk of all-cause (adjusted HR (aHR)=0.51, 95% CI: 0.34 to 0.77; p=0.001) and cardiovascular mortality (aHR=0.50, 95% CI: 0.31 to 0.80; p=0.004) compared with those in the clinical surveillance group irrespective of sex, receipt of other open-heart surgeries and underlying malignancy. These findings were seen only in those with preserved left ventricular ejection fraction (LVEF) ≥50%. Further, patients in the AVR group had a significant trend towards an increase in LVEF and a decrease in right ventricular systolic pressure compared with those in the clinical surveillance group. CONCLUSIONS: In patients with moderate AS, AVR was associated with favourable clinical outcomes and left ventricular remodelling.


Subject(s)
Aortic Valve Stenosis , Aortic Valve , Heart Valve Prosthesis Implantation , Ventricular Function, Left , Humans , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/physiopathology , Aortic Valve Stenosis/mortality , Aortic Valve Stenosis/diagnosis , Female , Male , Retrospective Studies , Aged , Heart Valve Prosthesis Implantation/methods , Ventricular Function, Left/physiology , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Treatment Outcome , Time Factors , Severity of Illness Index , Follow-Up Studies , Risk Factors , Echocardiography/methods , Aged, 80 and over , Survival Rate/trends , Risk Assessment/methods , Stroke Volume/physiology
9.
JACC Cardiovasc Imaging ; 17(4): 428-440, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38569793

ABSTRACT

Structural heart disease interventions rely heavily on preprocedural planning and simulation to improve procedural outcomes and predict and prevent potential procedural complications. Modeling technologies, namely 3-dimensional (3D) printing and computational modeling, are nowadays increasingly used to predict the interaction between cardiac anatomy and implantable devices. Such models play a role in patient education, operator training, procedural simulation, and appropriate device selection. However, current modeling is often limited by the replication of a single static configuration within a dynamic cardiac cycle. Recognizing that health systems may face technical and economic limitations to the creation of "in-house" 3D-printed models, structural heart teams are pivoting to the use of computational software for modeling purposes.


Subject(s)
Cardiac Surgical Procedures , Heart Diseases , Humans , Predictive Value of Tests , Cardiac Surgical Procedures/methods , Computer Simulation , Heart Diseases/diagnostic imaging , Heart Diseases/therapy , Software , Printing, Three-Dimensional
10.
Article in English | MEDLINE | ID: mdl-38641438

ABSTRACT

BACKGROUND: Candidates for transcatheter aortic valve replacement (TAVR) occasionally have a "borderline-size" aortic annulus between 2 transcatheter heart valve sizes, based on the manufacturer's sizing chart. Data on TAVR outcomes in such patients are limited. METHODS: We retrospectively reviewed 1816 patients who underwent transfemoral-TAVR with balloon-expandable valve (BEV) at our institution between 2016 and 2020. We divided patients into borderline and non-borderline groups based on computed tomography-derived annular measurements and compared outcomes. Furthermore, we analyzed procedural characteristics and compared outcomes between the smaller- and larger-valve strategies in patients with borderline-size annulus. RESULTS: During a median follow-up of 23.3 months, there was no significant difference between the borderline (n = 310, 17.0 %) and non-borderline (n = 1506) groups in mortality (17.3 % vs. 19.5 %; hazard ratio [HR] = 0.86 [95% CI = 0.62-1.20], p = 0.39), major adverse cardiac/cerebrovascular events (MACCE: death/myocardial infarction/stroke, 21.2 % vs. 21.5 %; HR = 0.97 [0.71-1.32], p = 0.85), paravalvular leak (PVL: mild 21.8 % vs. 20.6 %, p = 0.81; moderate 0 % vs. 1.2 %; p = 0.37), or mean gradient (12.9 ± 5.8 vs. 12.6 ± 5.2 mmHg, p = 0.69) at 1 year. There was no significant difference between the larger-(n = 113) and smaller-valve(n = 197) subgroups in mortality (23.7 % vs. 15.2 %; HR = 1.57 [0.89-2.77], p = 0.12), MACCE (28.1 % vs. 18.4 %; HR = 1.52 [0.91-2.54], p = 0.11), mild PVL (13.3 % vs. 25.9 %; p = 0.12), or mean gradient (12.3 ± 4.5 vs. 13.6 ± 5.3 mmHg, p = 0.16); however, the rate of permanent pacemaker implantation (PPI) was higher in the larger-valve subgroup (15.9 % vs. 2.6 %, p < 0.001). CONCLUSION: Borderline-size annulus is not associated with higher risk of adverse outcomes after BEV-TAVR. However, the larger-valve strategy for borderline-size annulus is associated with higher PPI risk, suggesting a greater risk of injury to the conduction system.

12.
J Am Heart Assoc ; 13(3): e032760, 2024 Feb 06.
Article in English | MEDLINE | ID: mdl-38293932

ABSTRACT

BACKGROUND: Data regarding permanent pacemaker (PPM) implantation following tricuspid valve surgery (TVS) are limited. We sought to evaluate its incidence, risk factors, and outcomes. METHODS AND RESULTS: Medicare beneficiaries who underwent TVS from 2013 to 2020 were identified. Patients who underwent TVS for endocarditis were excluded. The primary exposure of interest was new PPM after TVS. Outcomes included all-cause mortality and readmission with endocarditis or heart failure on follow-up. Among the 13 294 patients who underwent TVS, 2518 (18.9%) required PPM placement. Risk factors included female sex (relative risk [RR], 1.26 [95% CI, 1.17-1.36], P<0.0001), prior sternotomy (RR, 1.12 [95% CI, 1.02-1.23], P=0.02), preoperative second-degree heart block (RR, 2.20 [95% CI, 1.81-2.69], P<0.0001), right bundle-branch block (RR, 1.21 [95% CI, 1.03-1.41], P=0.019), bifascicular block (RR, 1.43 [95% CI, 1.06-1.93], P=0.02), and prior malignancy (RR, 1.23 [95% CI, 1.01-1.49], P=0.04). Tricuspid valve (TV) replacement was associated with a significantly higher risk of PPM implantation when compared with TV repair (RR, 3.20 [95% CI, 2.16-4.75], P<0.0001). After a median follow-up of 3.1 years, mortality was not different in patients who received PPM compared with patients who did not (hazard ratio [HR], 1.02 [95% CI, 0.93-1.12], P=0.7). PPM placement was not associated with a higher risk of endocarditis but was associated with a higher risk of heart failure readmission (HR, 1.28 [95% CI, 1.14-1.43], P<0.001). CONCLUSIONS: PPM implantation frequently occurs after TVS, notably in female patients and patients undergoing TV replacement. Although mortality is not increased, it is associated with higher rates of heart failure rehospitalization.


Subject(s)
Aortic Valve Stenosis , Endocarditis , Heart Failure , Pacemaker, Artificial , Transcatheter Aortic Valve Replacement , Humans , Female , Aged , United States/epidemiology , Aortic Valve Stenosis/surgery , Cardiac Pacing, Artificial/adverse effects , Incidence , Tricuspid Valve/surgery , Treatment Outcome , Medicare , Risk Factors , Transcatheter Aortic Valve Replacement/adverse effects , Bundle-Branch Block/therapy , Heart Failure/epidemiology , Heart Failure/therapy , Heart Failure/complications , Endocarditis/surgery , Aortic Valve/surgery , Retrospective Studies
13.
J Cardiovasc Dev Dis ; 10(12)2023 Nov 24.
Article in English | MEDLINE | ID: mdl-38132642

ABSTRACT

BACKGROUND: Regional functional left ventricular (LV) assessment using current imaging techniques remains limited. Inward displacement (InD) has been developed as a novel technique to assess regional LV function via measurement of the regional displacement of the LV endocardial border across each of the 17 LV segments. Currently, normal ranges for InD are not available for clinical use. The aim of this study was to validate the normal reference limits of InD in healthy adults across all LV segments. METHODS: InD was analyzed in 120 healthy subjects with a normal LV ejection fraction, using the three standard long-axis views obtained during cardiac MRI that quantified the degree of inward endocardial wall motion towards the true LV center of contraction. For all LV segments, InD was measured in mm and expressed as a percentage of the theoretical degree of maximal segment contraction towards the true LV centerline. The arithmetic average InD was obtained for each of the 17 segments. The LV was divided into three regions, obtaining average InD at the LV base (segments 1-6), mid-cavity (segments 7-12) and apex (segments 13-17). RESULTS: Average InD was 33.4 ± 4.3%. InD was higher in basal and mid-cavity LV segments (32.8 ± 4.1% and 38.1 ± 5.8%) compared to apical LV segments (28.6 ± 7.7%). Interobserver variability correlations for InD were strong (R = 0.80, p < 0.0001). CONCLUSIONS: We provide clinically meaningful reference ranges for InD in subjects with normal LV function, which will emerge as an important screening and assessment imaging tool for a range of HFrEF therapies.

SELECTION OF CITATIONS
SEARCH DETAIL