Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 6 de 6
1.
Biomacromolecules ; 25(4): 2312-2322, 2024 Apr 08.
Article En | MEDLINE | ID: mdl-38456765

Local delivery of pain medication can be a beneficial strategy to address pain management after joint replacement, as it can decrease systemic opioid usage, leading to less side and long-term effects. In this study, we used ultrahigh molecular weight polyethylene (UHMWPE), commonly employed as a bearing material for joint implants, to deliver a wide set of analgesics and the nonsteroidal anti-inflammatory drug tolfenamic acid. We blended the drugs with UHMWPE and processed the blend by compression molding and sterilization by low-dose gamma irradiation. We studied the chemical stability of the eluted drugs, drug elution, tensile properties, and wear resistance of the polymer blends before and after sterilization. The incorporation of bupivacaine hydrochloride and tolfenamic acid in UHMWPE resulted in either single- or dual-drug loaded materials that can be sterilized by gamma irradiation. These compositions were found to be promising for the development of clinically relevant drug-eluting implants for joint replacement.


Arthroplasty, Replacement , ortho-Aminobenzoates , Materials Testing , Polyethylenes/chemistry , Analgesics , Anti-Inflammatory Agents, Non-Steroidal
2.
J Orthop Res ; 42(2): 460-473, 2024 02.
Article En | MEDLINE | ID: mdl-37609941

Periprosthetic joint infections occur in about 2% of patients who undergo primary total joint arthroplasty, a procedure performed over 1 million times in the United States. The gold standard of treatment is a two-stage revision. This study aimed to establish a two-stage procedure in a preclinical small animal model (rat) to test and compare the efficacy of an antibiotic-eluting material in managing infection. Joint replacement was simulated by transchondylarly implanting a polyethylene (PE) plug into the distal femur and a titanium screw in the proximal tibia. Methicillin-sensitive Staphylococcus aureus (MSSA) 108 CFU/mL was injected into the tibial canal and the joint space before wound closure. The control groups were killed on postoperative day (POD) 18 (n = 12) and on POD 42 (n = 4) to assess both early and later-stage outcomes in the control group. The test group underwent revision surgery on POD 18 for treatment using gentamicin-eluting polyethylene (GPE, n = 4) and was observed until POD 42 to evaluate the efficacy of treatment. Our results showed that the bone loss for the treatment group receiving GPE was significantly less than that of the control (p < 0.05), which was supported by the histology images and an AI-tool assisted infection rate evaluation. Gait metrics duty factor imbalance and hindlimb temporal symmetry were significantly different between the treatment and control groups on Day 42. This animal model was feasible for evaluating treatments for peri-prosthetic joint infections (PJI) with a revision surgery and specifically that revision surgery and local antibiotic treatment largely hindered the peri-prosthetic bone loss. Statement of clinical significance: This revision model of peri-prosthetic infection has the potential of comparatively evaluating prophylaxis and treatment strategies and devices. Antibiotic-eluting UHMWPE is devised as at tool in treating PJI while providing weight bearing and joint space preservation.


Arthritis, Infectious , Prosthesis-Related Infections , Humans , Rats , Animals , Anti-Bacterial Agents/therapeutic use , Prosthesis-Related Infections/drug therapy , Prosthesis-Related Infections/surgery , Arthritis, Infectious/drug therapy , Gentamicins/therapeutic use , Reoperation , Polyethylenes , Retrospective Studies
3.
BMC Musculoskelet Disord ; 24(1): 854, 2023 Oct 31.
Article En | MEDLINE | ID: mdl-37907937

BACKGROUND: Rodent models are commonly employed to validate preclinical disease models through the evaluation of postoperative behavior and allodynia. Our study investigates the dynamic interplay between pain and functional recovery in the context of traumatic osteotomy and surgical repair. Specifically, we established a rat model of tibial osteotomy, followed by internal fixation using a 5-hole Y-plate with 4 screws, to explore the hypothesis that histological bone healing is closely associated with functional recovery. OBJECTIVE: Our primary objective was to assess the correlation between bone healing and functional outcomes in a rat model of tibial osteotomy and plate fixation. METHODS: Seventeen male Sprague-Dawley rats underwent a metaphyseal transverse osteotomy of the proximal tibia, simulating a fracture-like injury. The resultant bone defect was meticulously repaired by realigning and stabilizing the bone surfaces with the Y-plate. To comprehensively assess recovery and healing, we performed quantitative and qualitative evaluations at 2, 4, 6, and 8 weeks post-surgery. Evaluation methods included micro-CT imaging, X-ray analysis, and histological examination to monitor bone defect healing. Concurrently, we employed video recording and gait analysis to evaluate functional recovery, encompassing parameters such as temporal symmetry, hindlimb duty factor imbalance, phase dispersion, and toe spread. RESULTS: Our findings revealed complete healing of the bone defect at 8 weeks, as confirmed by micro-CT and histological assessments. Specifically, micro-CT data showed a decline in fracture volume over time, indicating progressive healing. Histological examination demonstrated the formation of new trabecular bone and the resolution of inflammation. Importantly, specific gait analysis parameters exhibited longitudinal changes consistent with bone healing. Hindlimb duty factor imbalance, hindlimb temporal symmetry, and phase dispersion correlated strongly with the healing process, emphasizing the direct link between bone healing and functional outcomes. CONCLUSIONS: The establishment of this tibia osteotomy model underscores the association between bone healing and functional outcomes, emphasizing the feasibility of monitoring postoperative recovery using endpoint measurements. Our overarching objective is to employ this model for assessing the local efficacy of drug delivery devices in ameliorating post-surgical pain and enhancing functional recovery.


Fracture Healing , Tibial Fractures , Rats , Male , Animals , Rats, Sprague-Dawley , Osteotomy/methods , Tibia/diagnostic imaging , Tibia/surgery , Tibial Fractures/diagnostic imaging , Tibial Fractures/surgery , X-Ray Microtomography , Bone Plates
4.
J Control Release ; 361: 20-28, 2023 09.
Article En | MEDLINE | ID: mdl-37451545

The high prevalence of opioid addiction and the shortcomings of systemic opioids has increased the pace of the search for alternative methods of pain management. The local delivery of pain medications has started to be used as a tool for pain management and to decrease the use of systemic opioids for these patients. Here, we explored an in-situ polymerizable hydrogel system for the local delivery of analgesics and nonsteroid anti-inflammatory drugs (NSAID) for orthopaedic applications. We synthesized a series of methacrylated oligomeric polyethylene glycol-co-lactic acid polymer using microwave radiation for the delivery of bupivacaine hydrochloride as an analgesic and ketorolac tromethamine as an NSAID. We determined drug elution and gel degradation profiles in vitro. Biocompatibility was assessed against osteoblasts in vitro and by histological analysis after subcutaneous implantation for 4 weeks in vivo. Intra-articular and systemic concentrations and pharmacokinetic parameters were estimated using a two-compartment pharmacodynamic model based on in-vitro elution profiles. This type of in-situ applicable hydrogels is promising for extending the local efficacy of pain medication and further reducing the need for opioids.


Analgesics, Opioid , Hydrogels , Humans , Hydrogels/therapeutic use , Polymerization , Anti-Inflammatory Agents, Non-Steroidal , Analgesics , Pain/drug therapy
5.
J Biomed Mater Res B Appl Biomater ; 111(4): 912-922, 2023 04.
Article En | MEDLINE | ID: mdl-36462210

Total joint arthroplasty is one of the most common surgeries in the United States, with almost a million procedures performed annually. Periprosthetic joint infections (PJI) remain the most devastating complications associated with total joint replacement. Effective antibacterial prophylaxis after primary arthroplasty could substantially reduce incidence rate of PJI. In the present study we propose to provide post-arthroplasty prophylaxis via dual-analgesic loaded ultra-high molecular weight polyethylene (UHMWPE). Our approach is based on previous studies that showed pronounced antibacterial activity of analgesic- and NSAID-loaded UHMWPE against Staphylococci. Here, we prepared bupivacaine/tolfenamic acid-loaded UHMWPE and assessed its antibacterial activity against Staphylococcus aureus and Staphylococcus epidermidis. Dual-drug loaded UHMWPE yielded an additional 1-2 log reduction of bacteria, when compared with single-drug loaded UHMWPE. Analysis of the drug elution kinetics suggested that the observed increase in antibacterial activity is due to the increased tolfenamic acid elution from dual-drug loaded UHMWPE. We showed that the increased fractal dimension of the drug domains in UHMWPE could be associated with increased drug elution, leading to higher antibacterial activity. Dual-analgesic loaded UHMWPE proposed here can be used as part of multi-modal antibacterial prophylaxis and promises substantial reduction in post-arthroplasty mortality and morbidity.


Arthroplasty, Replacement , Staphylococcus , Anti-Bacterial Agents/pharmacology , Polyethylenes/pharmacology , Analgesics
6.
Bone Joint J ; 102-B(6_Supple_A): 151-157, 2020 Jun.
Article En | MEDLINE | ID: mdl-32475290

AIMS: We propose a state-of-the-art temporary spacer, consisting of a cobalt-chrome (CoCr) femoral component and a gentamicin-eluting ultra-high molecular weight polyethylene (UHMWPE) tibial insert, which can provide therapeutic delivery of gentamicin, while retaining excellent mechanical properties. The proposed implant is designed to replace conventional spacers made from bone cement. METHODS: Gentamicin-loaded UHMWPE was prepared using phase-separated compression moulding, and its drug elution kinetics, antibacterial, mechanical, and wear properties were compared with those of conventional gentamicin-loaded bone cement. RESULTS: Gentamicin-loaded UHMWPE tibial components not only eradicated planktonic Staphylococcus aureus, but also prevented colonization of both femoral and tibial components. The proposed spacer possesses far superior mechanical and wear properties when compared with conventional bone cement spacers. CONCLUSION: The proposed gentamicin-eluting UHMWPE spacer can provide antibacterial efficacy comparable with currently used bone cement spacers, while overcoming their drawbacks. The novel spacer proposed here has the potential to drastically reduce complications associated with currently used bone cement spacers and substantially improve patients' quality of life during the treatment. Cite this article: Bone Joint J 2020;102-B(6 Supple A):151-157.


Anti-Bacterial Agents/administration & dosage , Bone Cements , Drug Carriers , Gentamicins/administration & dosage , Knee Prosthesis/adverse effects , Polyethylenes , Prostheses and Implants , Prosthesis-Related Infections/drug therapy , Prosthesis-Related Infections/etiology , Staphylococcal Infections/drug therapy , Staphylococcus aureus , Humans , Tibia
...