1.
Nat Nanotechnol ; 17(9): 984-992, 2022 09.
Article in English | MEDLINE | ID: mdl-35879456

ABSTRACT

Quantitative polymerase chain reaction (qPCR) offers the capabilities of real-time monitoring of amplified products, fast detection, and quantitation of infectious units, but poses technical hurdles for point-of-care miniaturization compared with end-point polymerase chain reaction. Here we demonstrate plasmonic thermocycling, in which rapid heating of the solution is achieved via infrared excitation of nanoparticles, successfully performing reverse-transcriptase qPCR (RT-qPCR) in a reaction vessel containing polymerase chain reaction chemistry, fluorescent probes and plasmonic nanoparticles. The method could rapidly detect SARS-CoV-2 RNA from human saliva and nasal specimens with 100% sensitivity and 100% specificity, as well as two distinct SARS-CoV-2 variants. The use of small optical components for both thermocycling and multiplexed fluorescence monitoring renders the instrument amenable to point-of-care use. Overall, this study demonstrates that plasmonic nanoparticles with compact optics can be used to achieve real-time and multiplexed RT-qPCR on clinical specimens, towards the goal of rapid and accurate molecular clinical diagnostics in decentralized settings.


Subject(s)
COVID-19 , Nanoparticles , COVID-19/diagnosis , COVID-19 Testing , DNA-Directed RNA Polymerases , Fluorescent Dyes , Humans , Point-of-Care Systems , RNA, Viral/genetics , Real-Time Polymerase Chain Reaction , Reverse Transcriptase Polymerase Chain Reaction , SARS-CoV-2/genetics , Sensitivity and Specificity
2.
Lasers Surg Med ; 52(8): 788-798, 2020 10.
Article in English | MEDLINE | ID: mdl-31943251

ABSTRACT

BACKGROUND AND OBJECTIVES: A recent generation of 5,500 nm wavelength carbon monoxide (CO) lasers could serve as a novel tool for applications in medicine and surgery. At this wavelength, the optical penetration depth is about three times higher than that of the 10,600 nm wavelength carbon dioxide (CO2 ) laser. As the amount of ablation and coagulation is strongly influenced by the wavelength, we anticipated that CO lasers would provide extended coagulation zones, which could be beneficial for several medical applications, such as tissue tightening effects after laser skin resurfacing. Until now, the 1,940 nm wavelength thulium fiber (Tm:fiber) laser is primarily known as a non-ablative laser with an optical penetration depth that is eight times higher than that of the CO2 laser. The advantage of lasers with shorter wavelengths is the ability to create smaller spot sizes, which has a determining influence on the ablation outcome. In this study, the ablation and coagulation characteristics of a novel CO laser and a high power Tm:fiber laser were investigated to evaluate their potential application for fractional ablation of the skin. STUDY DESIGN/MATERIALS AND METHODS: Laser-tissue exposures were performed using a novel CO laser, a modified, pulse-width-modulated CO2 laser, and a Tm:fiber laser. We used discarded ex vivo human skin obtained from abdominoplasty as tissue samples. Similar exposure parameters, such as spot size (108-120 µm), pulse duration (2 milliseconds), and pulse energy (~10-200 mJ) were adjusted for the different laser systems with comparable temporal pulse structures. Laser effects were quantified by histology. RESULTS: At radiant exposures 10-fold higher than the ablation threshold, the CO laser ablation depth was almost two times deeper than that of the CO2 laser. At 40-fold of the ablation threshold, the CO laser ablation was 47% deeper. The ablation craters produced by the CO laser exhibited about two times larger coagulation zones when compared with the CO2 laser. In contrast, the Tm:fiber laser exhibited superficial ablation craters with massive thermal damage. CONCLUSIONS: The tissue ablation using the Tm:fiber laser was very superficial in contrast to the CO laser and the CO2 laser. However, higher etch depths should be obtainable when the radiant exposure is increased by using higher pulse energies and/or smaller spot sizes. At radiant exposures normalized to the ablation threshold, the CO laser was capable of generating deeper ablation craters with extended coagulation zones compared with the CO2 laser, which is possibly desirable depending on the clinical goal. The effect of deep ablation combined with additional thermal damage on dermal remodeling needs to be further confirmed with in vivo studies. Lasers Surg. Med. © 2020 The Authors. Lasers in Surgery and Medicine Published by Wiley Periodicals, Inc.


Subject(s)
Laser Therapy , Lasers, Gas , Carbon Monoxide , Humans , Lasers, Gas/therapeutic use , Skin , Thulium
3.
Lasers Surg Med ; 48(5): 555-61, 2016 07.
Article in English | MEDLINE | ID: mdl-26842919

ABSTRACT

BACKGROUND AND OBJECTIVE: Fractional Photothermolysis (FP) is a method of skin treatment that generates a thermal damage pattern consisting of multiple columns of thermal damage, also known as microscopic treatment zones (MTZs). They are very small in diameter and are generated by application of highly focused laser beams. In order to obtain the smallest spot size, the treatment should be performed in the focal plane. Any deviation from the focal plane (DFP) results in an increase of spot size. FP devices typically utilize distance holders in order to facilitate exposures at this specific location. In spite of the use of distance holders, DFP can occur. In particular, variations of contact pressure to the skin surface and anatomical treatment areas of high surface curvature may be prone to DFP during FP treatments. The impact of such distance variation on lesion geometry, such as depth and diameter of the thermal injury, has not previously been evaluated. The objective of this study was to investigate the relation between DFP and the resulting lesion geometry for a selected ablative fractional device. MATERIAL AND METHODS: A handpiece of an ablative fractional laser (DeepFX, UltraPulse Encore, Lumenis, Yokneam, Israel) was mounted to a rigid stand. Full thickness human skin obtained from abdominoplasty was mounted to a separate stand perpendicular to the handpiece. The tissue stand allowed the distance between the handpiece and the tissue to be adjusted to produce a variation up to ±3 mm from the focal plane. A 1 × 1 cm(2) scanning area of 169 MTZs, 50 mJ energy per MTZ, 120 µm nominal spot size, was applied at -3, -2, -1, 0, +1, +2, and +3 mm deviated from the focal plane. Minus (-) and plus (+) signs indicate decreasing and increasing distance between the handpiece and the tissue, respectively. Depth and diameter of the laser induced tissue lesions were assessed and quantified. RESULTS: DFPs produced a significant alteration of the lesion geometry. DFPs of -3, -2, -1, 0, +1, +2, +3 mm resulted in average lesion depths of 1,020 (-40%), 1,180 (-31%), 1,400 (-18%), 1,700 (0%), 1,620 (-5%), 780 (-55%), 680 (-60%) µm, and average lesion diameters of 314 (+26%), 311 (+25%), 273 (+10%), 248 (0%), 256 (+3%), 316 (+27%), 359 (+44%) µm, respectively. The underlined values represent the focal plane. The percentage changes relative to values at focal plane are in parentheses. CONCLUSIONS: A relatively minor DFP has a marked impact on the thermal injury profile, including lesion depth and diameter, of the laser-exposed tissue. Such marked changes of the thermal injury profile might affect the wound healing, safety, and efficacy of ablative fractional resurfacing procedures. Clinicians should carefully maintain the focal plane during ablative fractional treatment for reproducible results. The presented data are device specific and the clinical impact of such alteration of thermal injury profile warrants further investigation. Lasers Surg. Med. 48:555-561, 2016. © 2016 Wiley Periodicals, Inc.


Subject(s)
Burns/etiology , Laser Therapy/adverse effects , Skin/injuries , Burns/diagnosis , Burns/pathology , Humans , In Vitro Techniques , Laser Therapy/instrumentation , Laser Therapy/methods , Skin/pathology
4.
Appl Opt ; 43(12): 2555-60, 2004 Apr 20.
Article in English | MEDLINE | ID: mdl-15119625

ABSTRACT

Unabsorbed pump light in passively Q-switched microlasers leads to suboptimal pulse generation by bleaching the saturable absorber. This mechanism increases the effective unsaturated transmission of the absorber, which leads to a change in the system dynamics that results in increased pulse durations and decreased pulse energies. We report experimental evidence of pump-induced bleaching of the saturable absorber, an increase in the pulse duration from 360 to 880 ps, and develop a simple analytical treatment that includes this effect within the framework of existing passive Q-switching models.