Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 10 de 10
1.
Diagn Interv Radiol ; 29(6): 826-831, 2023 11 07.
Article En | MEDLINE | ID: mdl-37745308

PURPOSE: This study investigates the usefulness of antegrade variceal embolization using sclerosant foam to evaluate technical success and clinical outcomes in cases of hypertensive variceal bleeding. METHODS: A total of 16 patients underwent percutaneous antegrade variceal embolization using foam sclerotherapy from August 2019 to January 2022. Among the patients, 12 cases were of gastroesophageal varices, two were rectal varices, and one case each was duodenal and jejunal varices, respectively. Sodium tetradecyl sulfate (STS) foam was used as a detergent for variceal bleeding sclerotherapy at various anatomical locations. The detergent was used in a foam form to promote clinical outcomes and enable the effective embolization of the entire blood vessel wall, including the ventral side, against gravity. Furthermore, STS foam could be used to help sufficiently deliver the drug to distal segments. A balloon catheter was also used to block the antegrade flow and prevent the dilution of the sclerosant. Technical success was defined as the completion of sclerotherapy for variceal bleeding as planned before the procedure to achieve the disappearance of variceal bleeding. Clinical success was defined as the complete obliteration of varices without recurrent bleeding during the follow-up period after the procedure. RESULTS: Technical success was 81.3%, and clinical success was 84.6%. Additionally, 15/16 of the procedures were emergencies, and there were no complications related to the procedure. CONCLUSION: Antegrade foam sclerotherapy using 3% STS for variceal bleeding is clinically safe and effective. Moreover, antegrade foam sclerotherapy can be a useful treatment option for patients with active variceal bleeding in emergency cases.


Esophageal and Gastric Varices , Varicose Veins , Humans , Sclerotherapy/methods , Esophageal and Gastric Varices/complications , Esophageal and Gastric Varices/therapy , Sclerosing Solutions/therapeutic use , Sclerosing Solutions/adverse effects , Detergents , Gastrointestinal Hemorrhage/etiology , Gastrointestinal Hemorrhage/therapy , Varicose Veins/complications , Varicose Veins/therapy , Varicose Veins/chemically induced , Sodium Tetradecyl Sulfate/therapeutic use
2.
Eur Radiol ; 33(11): 7697-7706, 2023 Nov.
Article En | MEDLINE | ID: mdl-37314472

OBJECTIVES: To determine the clinical feasibility of T2-weighted turbo spin-echo (T2-TSE) imaging with deep learning reconstruction (DLR) in female pelvic MRI compared with conventional T2 TSE in terms of image quality and scan time. METHODS: Between May 2021 and September 2021, 52 women (mean age, 44 years ± 12) who underwent 3-T pelvic MRI with additional T2-TSE using a DLR algorithm were included in this single-center prospective study with patient's informed consents. Conventional, DLR, and DLR T2-TSE images with reduced scan times were independently assessed and compared by four radiologists. The overall image quality, differentiation of anatomic details, lesion conspicuity, and artifacts were evaluated using a 5-point scale. Inter-observer agreement of the qualitative scores was compared and reader protocol preferences were then evaluated. RESULTS: In the qualitative analysis of all readers, fast DLR T2-TSE showed significantly better overall image quality, differentiation of anatomic regions, lesion conspicuity, and lesser artifacts than conventional T2-TSE and DLR T2-TSE, despite approximately 50% reduction in scan time (all p < 0.05). The inter-reader agreement for the qualitative analysis was moderate to good. All readers preferred DLR over conventional T2-TSE regardless of scan time and preferred fast DLR T2-TSE (57.7-78.8%), except for one who preferred DLR over fast DLR T2-TSE (53.8% vs. 46.1%). CONCLUSION: In female pelvic MRI, image quality and accelerated image acquisition for T2-TSE can be significantly improved by using DLR compared to conventional T2-TSE. Fast DLR T2-TSE was non-inferior to DLR T2-TSE in terms of reader preference and image quality. CLINICAL RELEVANCE STATEMENT: DLR of T2-TSE in female pelvic MRI enables fast imaging along with maintaining optimal image quality compared with parallel imaging-based conventional T2-TSE. KEY POINTS: • Conventional T2 turbo spin-echo based on parallel imaging has limitations for accelerated image acquisition while maintaining good image quality. • Deep learning image reconstruction showed better image quality in both images obtained using the same or accelerated image acquisition parameters compared with conventional T2 turbo spin-echo in female pelvic MRI. • Deep learning image reconstruction enables accelerated image acquisition while maintaining good image quality in the T2-TSE of female pelvic MRI.


Deep Learning , Humans , Female , Adult , Prospective Studies , Magnetic Resonance Imaging/methods , Radiography , Algorithms , Artifacts
3.
Curr Med Imaging ; 19(12): 1372-1377, 2023.
Article En | MEDLINE | ID: mdl-36788683

BACKGROUND: Many studies have shown that vertebral trabecular attenuation measured on CT scan corresponds well to DXA results for bone mineral density. These studies were based on crosssectional data. Hence, there were limitations in explaining the constantly changing vertebral trabecular attenuation from CT and T-score from DXA over time. OBJECTIVE: This study aimed to determine the longitudinal association between the vertebral trabecular attenuation measured on computed tomography (CT) and the T-score measured by dual-energy X-ray absorptiometry (DXA). METHODS: We performed a database search for 333 patients who underwent surgery for breast cancer, preoperative treatment, and at least one follow-up chest CT and DXA from January, 2013 through May, 2021. One musculoskeletal radiologist measured the mean vertebral trabecular attenuation of lumbar vertebra 1(L1) on axial unenhanced images at the pedicle level by manually placing the region of interest (ROI). DXA of the lumbar spine was performed, and the lowest T-score of the lumbar spine was used for the analysis. We evaluated the association between L1 trabecular attenuation from chest CT and T-score from DXA over time using the generalized estimating equations (GEE) model to analyze longitudinal corrected data. RESULTS: A total of 150 women (mean age, 52.4 ± 11.0 years) were included. There was a statistically significant association between L1 trabecular attenuation from chest CT and T-score from DXA in the unadjusted model (p < 0.001) and adjusted model (p < 0.001). T-score value increased by 0.172 (95% confidence interval (CI): 0.145-0.200, p < 0.001) per 10 unit (HU) of L1 trabecular attenuation at time = 0 in unadjusted model and by 0.173 (95% CI: 0.143-0.203, p < 0.001) in all adjusted model. CONCLUSION: We demonstrated that L1 attenuation from chest CT images was longitudinally associated with T-score from DXA, and the degree of association appeared to be decreased over time in breast cancer patients regardless of their medical condition.


Breast Neoplasms , Osteoporosis , Humans , Female , Adult , Middle Aged , Bone Density , Absorptiometry, Photon/methods , Osteoporosis/complications , Retrospective Studies , Tomography, X-Ray Computed/methods
4.
J Korean Soc Radiol ; 84(1): 304-310, 2023 Jan.
Article En | MEDLINE | ID: mdl-36818699

Solitary fibrous tumors (SFTs) commonly arise from the pleura and are mostly benign. However, they may develop anywhere in the body, and 10%-30% are malignant. Classically, SFTs appear as solitary enhancing masses, and bilateral presentation is extremely rare. In this case, an 88-year-old male presented with back pain and a history of chronic tuberculous empyema. Imaging studies revealed bilateral paravertebral masses with aggressive radiologic features, which were speculatively presumed as thoracic malignancies in association with chronic empyema. Herein, we report a unique case of bilateral paravertebral malignant SFTs that were accurately diagnosed with a CT-guided coaxial needle biopsy.

5.
J Korean Soc Radiol ; 84(1): 127-149, 2023 Jan.
Article Ko | MEDLINE | ID: mdl-36818713

It is important to distinguish uterine lesions from other lesions occurring in the pelvic cavity for the proper management. The primary radiological evaluation of uterine lesions is performed using transvaginal ultrasonography, and if the lesion is too large or shows atypical benign imaging findings, magnetic resonance imaging should be performed. Analyzing radiological findings of uterine lesions through a pattern recognition approach can help establish the accurate diagnosis and treatment plan. In this pictorial assay, we describe imaging characteristics of various lesions arising from the uterus and evaluate them based on the pattern recognition approach.

6.
Eur J Radiol ; 154: 110428, 2022 Sep.
Article En | MEDLINE | ID: mdl-35797791

PURPOSE: To assess the clinical feasibility of accelerated deep learning-reconstructed diffusion weighted imaging (DWI) and to compare its image quality and acquisition time with those of conventional DWI. METHODS: Seventy-four consecutive patients who underwent 3 T abdominal magnetic resonance imaging (MRI) were retrospectively enrolled. DWI were acquired using both conventional DWI and DWI with deep-learning reconstruction (DL DWI). Image quality (overall image quality, anatomic sharpness and details, artifacts, noise, and lesion conspicuity) was scored by two radiologists and compared between two DWI sequences. The apparent diffusion coefficient (ADC) was measured in six locations of the liver parenchyma and focal lesions and compared between two DWI sequences. RESULTS: The mean acquisition time for the DL DWI (216.87 ± 49.23 sec) was significantly shorter (P < 0.001) than for conventional DWI (358.69 ± 105.93 sec). DL DWI achieved higher scores than conventional DWI for all qualitative image quality parameters (P < 0.001). DL DWI had a more homogeneous distribution of ADC values throughout the liver, except for the left superior section, compared with conventional DWI. The standard deviations of the ADC values for all hepatic areas were significantly lower in DL DWI than in conventional DWI (all, P < 0.001). The ADC values for the liver parenchyma and focal hepatic lesions were lower in DL DWI than in conventional DWI. CONCLUSIONS: DL DWI is a feasible acquisition technique in clinical routines and provides improved image quality and simultaneously significant reduction in scan time compared with conventional DWI.


Deep Learning , Abdomen/diagnostic imaging , Diffusion Magnetic Resonance Imaging/methods , Feasibility Studies , Humans , Reproducibility of Results , Retrospective Studies
7.
J Vasc Surg Venous Lymphat Disord ; 10(4): 916-921, 2022 07.
Article En | MEDLINE | ID: mdl-35074520

OBJECTIVE: To evaluate the outcome of endovascular treatment after surgical treatment for cephalic arch stenosis (CAS) in the brachiocephalic fistula (BCF) and to analyze the factors influencing patency. METHODS: We conducted a retrospective review of patients undergoing cephalic vein transposition (CVT) or graft interposition (GIP) for CAS from January 1, 2017, to December 31, 2019. A total of 73 patients with restenosis were included in this study. Patients were classified into cephalic transposition (BCF-CVT) (n = 49) and graft interposition (BCF-GIP) (n = 24) groups. We calculated the postintervention primary and secondary patency of endovascular treatment by using the Kaplan-Meier analysis and analyzed variables associated with loss of postintervention patency. RESULTS: Six-month and 12-month postintervention primary patency rates of endovascular treatment for restenosis were 56.7% and 15.6% and secondary patency rates were 89.7% and 72.1%, respectively. In the BCF-CVT group, 6-month and 12-month postintervention primary patency was 56.8% and 17.6% and secondary patency was 93.3% and 79.4%, respectively. In the BCF-GIP group, 6-month and 12-month postintervention primary patency was 56.5% and 8.7% and secondary patency was 85.7% and 56.3%, respectively. There was no significant difference in postintervention primary patency between the two groups (P = .79). However, the BCF-CVT group demonstrated higher postintervention secondary patency (P = .034). The BCF-GIP group had a higher number of stenosis sites (P < .01). There was no significant predictor of reduced postintervention primary patency. The only adverse variable of postintervention secondary patency was BCF-GIP (hazard ratio, 3.14; 95% CI, 1.06-9.34; P < .05). CONCLUSIONS: Endovascular treatment is still the acceptable option for stenosis occurring after surgical treatment for CAS. CVT provides higher postintervention secondary patency than GIP.


Arteriovenous Shunt, Surgical , Arteriovenous Shunt, Surgical/adverse effects , Constriction, Pathologic , Graft Occlusion, Vascular/diagnostic imaging , Graft Occlusion, Vascular/etiology , Graft Occlusion, Vascular/surgery , Humans , Renal Dialysis , Retrospective Studies , Treatment Outcome , Vascular Patency
8.
Radiology ; 302(1): 187-197, 2022 01.
Article En | MEDLINE | ID: mdl-34636634

Background Evaluation of interstitial lung disease (ILD) at CT is a challenging task that requires experience and is subject to substantial interreader variability. Purpose To investigate whether a proposed content-based image retrieval (CBIR) of similar chest CT images by using deep learning can aid in the diagnosis of ILD by readers with different levels of experience. Materials and Methods This retrospective study included patients with confirmed ILD after multidisciplinary discussion and available CT images identified between January 2000 and December 2015. Database was composed of four disease classes: usual interstitial pneumonia (UIP), nonspecific interstitial pneumonia (NSIP), cryptogenic organizing pneumonia, and chronic hypersensitivity pneumonitis. Eighty patients were selected as queries from the database. The proposed CBIR retrieved the top three similar CT images with diagnosis from the database by comparing the extent and distribution of different regional disease patterns quantified by a deep learning algorithm. Eight readers with varying experience interpreted the query CT images and provided their most probable diagnosis in two reading sessions 2 weeks apart, before and after applying CBIR. Diagnostic accuracy was analyzed by using McNemar test and generalized estimating equation, and interreader agreement was analyzed by using Fleiss κ. Results A total of 288 patients were included (mean age, 58 years ± 11 [standard deviation]; 145 women). After applying CBIR, the overall diagnostic accuracy improved in all readers (before CBIR, 46.1% [95% CI: 37.1, 55.3]; after CBIR, 60.9% [95% CI: 51.8, 69.3]; P < .001). In terms of disease category, the diagnostic accuracy improved after applying CBIR in UIP (before vs after CBIR, 52.4% vs 72.8%, respectively; P < .001) and NSIP cases (before vs after CBIR, 42.9% vs 61.6%, respectively; P < .001). Interreader agreement improved after CBIR (before vs after CBIR Fleiss κ, 0.32 vs 0.47, respectively; P = .005). Conclusion The proposed content-based image retrieval system for chest CT images with deep learning improved the diagnostic accuracy of interstitial lung disease and interreader agreement in readers with different levels of experience. © RSNA, 2021 Online supplemental material is available for this article. See also the editorial by Wielpütz in this issue.


Deep Learning , Lung Diseases, Interstitial/diagnostic imaging , Radiographic Image Interpretation, Computer-Assisted/methods , Tomography, X-Ray Computed/methods , Diagnosis, Differential , Female , Humans , Lung/diagnostic imaging , Male , Middle Aged , Reproducibility of Results , Retrospective Studies
9.
J Med Imaging Radiat Oncol ; 62(5): 634-641, 2018 Oct.
Article En | MEDLINE | ID: mdl-29797407

INTRODUCTION: The development of dual-energy CT and metal artefact reduction software provides a further chance of reducing metal-related artefacts. However, there have been only a few studies regarding whether MARs practically affect visibility of structures around a metallic hip prosthesis on post-operative CT evaluation. METHODS: Twenty-seven patients with 42 metallic hip prostheses underwent DECT. The datasets were reconstructed with 70, 90 and 110 keV with and without MARs. The areas were classified into 10 zones according to the reference zone. All the images were reviewed in terms of the severity of the beam-hardening artefacts, differentiation of the bony cortex and trabeculae and visualization of trabecular patterns with a three-point scale. The metallic screw diameter was measured in the acetabulum with 110 keV images. RESULTS: The scores were the worst on 70 keV images without MARs [mean scores:1.84-4.22 (p < 0.001-1.000)]. The structures in zone II were best visualized on 110 keV (p < 0.001-0.011, mean scores: 2.86-5.22). In other zones, there is general similarity in mean scores whether applying MARs or not (p < 0.001-0.920). The mean diameter of the screw was 5.85 mm without MARs and 3.44 mm with MARs (mean reference diameter: 6.48 mm). CONCLUSION: The 110 keV images without MARs are best for evaluating acetabular zone II. The visibility of the bony structures around the hip prosthesis is similar in the other zones with or without MARs regardless of keV. MARS may not be needed for the evaluation of the metallic hip prosthesis itself at sufficient high-energy levels; however, MARS still has a role in the evaluation of other soft tissues around the prosthesis.


Artifacts , Hip Joint/diagnostic imaging , Hip Prosthesis , Radiographic Image Interpretation, Computer-Assisted/methods , Tomography, X-Ray Computed/methods , Adult , Aged , Aged, 80 and over , Female , Humans , Male , Metals , Middle Aged , Retrospective Studies , Software
10.
Ultrasonography ; 34(1): 74-7, 2015 Jan.
Article En | MEDLINE | ID: mdl-25475648

We describe a rare case of terminal ileal diverticulitis in a 68-year-old female with a day of history of right lower quadrant pain and tenderness, mimicking acute appendicitis. Ultrasonography revealed small sac-like out-pouching lesions with increased echogenicity of surrounding fat in thickened terminal ileum, suggesting inflamed diverticula. We diagnosed terminal ileal diverticulitis primarily by ultrasonography. The diagnosis was confirmed by subsequent computed tomography.

...