Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Publication year range
1.
Ecotoxicol Environ Saf ; 251: 114562, 2023 Feb.
Article in English | MEDLINE | ID: mdl-36680992

ABSTRACT

PM2.5 is a complex pollutant that is a pervasive threat to human health. The health risks and toxicity mechanisms of PM2.5 components must be identified to alleviate the corresponding risks. In this study, a reductionism approach based on model PM2.5 particles was used to investigate the contributions of the most harmful components in PM2.5 to its toxicity. Human liver and kidney cells were used as models. The results showed that Cr(VI) was the most critical toxic component among other components (Pb, As, and benzo[a]pyrene) in human liver and kidney cells. PM2.5-Cr(VI) induced oxidative stress, which led to cytotoxicity by inducing cell cycle arrest in the S-phase in HepG2 and HEK293 cells. The presented findings can provide valuable insights into the toxicity levels of PM2.5 components, which can help clarify the potential health risks from PM2.5 exposure.


Subject(s)
Air Pollutants , Metals, Heavy , Humans , Air Pollutants/toxicity , Air Pollutants/analysis , Particulate Matter/toxicity , Particulate Matter/analysis , HEK293 Cells , Metals, Heavy/toxicity , Metals, Heavy/analysis , Environmental Monitoring
2.
Fa Yi Xue Za Zhi ; 38(5): 595-600, 2022 Oct 25.
Article in English, Chinese | MEDLINE | ID: mdl-36727175

ABSTRACT

OBJECTIVES: To establish a combined high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) and gas chromatography-mass spectrometry (GC-MS) method to detect the synthetic cannabinoid CUMYL-PEGACLONE in e-cigarette oil and hair. METHODS: HPLC-MS/MS and GC-MS were used to establish the detection method of CUMYL-PEGACLONE, and the hair of drug-involved persons and the seized e-cigarette oil were detected. RESULTS: The main mass spectrometry characteristic ions m/z of CUMYL-PEGACLONE measured by GC-MS were 91, 179, 197, 254 and 372. CUMYL-PEGACLONE had a good linear relationship in the mass concentration range of 2-50 ng/mL, and the linear correlation coefficient (r) was greater than 0.99. The limit of detection (LOD) of CUMYL-PEGACLONE in hair was 0.01 ng/mg, and the limit of quantitation (LOQ) was 0.02 ng/mg. The LOD of CUMYL-PEGACLONE in e-cigarette oil was 1 ng/mg, and the LOQ was 2 ng/mg. The average recoveries of CUMYL-PEGACLONE under the attempt at high, intermediate and low levels in blank human hair and e-cigarette oil matrix were 98.2%-132.4% and 93.5%-110.6%, and the intraday and intraday precision were 1.2%-12.9% and 0.7%-2.9%. CUMYL-PEGACLONE was detected in the hair of 15 drug-involved persons. Except for 1 person who was lower than LOQ, the concentration of CUMYL-PEGACLONE in the hair of other 14 persons was 0.035-0.563 ng/mg. The mass fraction of CUMYL-PEGACLONE in 2 e-cigarette oil were 0.17% and 0.21%, respectively. CONCLUSIONS: The established HPLC-MS/MS and GC-MS methods are applied to the detection of HPLC-MS/MS in drug-related cases, which provides strong evidence support for the handling authority to quickly investigate these cases, and also provides a reference for the identification of such substances in future.


Subject(s)
Cannabinoids , Electronic Nicotine Delivery Systems , Illicit Drugs , Humans , Illicit Drugs/analysis , Tandem Mass Spectrometry , Hair/chemistry , Limit of Detection , Substance Abuse Detection/methods
SELECTION OF CITATIONS
SEARCH DETAIL
...