Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
PLoS One ; 19(7): e0306472, 2024.
Article in English | MEDLINE | ID: mdl-38959257

ABSTRACT

OBJECTIVE: To determine the effect of different types of probes for lung ultrasound in neonates. DESIGN: Prospective, blinded, randomized, comparative study between 2020 and 2022. SETTING: Single-center study at a third level neonatal unit. PATIENTS: Hemodynamically stable infants with either nasal continuous positive airway pressure, high flow nasal cannula or without respiratory support. INTERVENTION: Lung ultrasound using either an echo or microconvex probe. As control, the linear probe was used. MAIN OUTCOME MEASURES: Primary outcome measure was neonatologist performed lung ultrasound (NPLUS) score. Secondary outcome measures were number of B-Lines, thickness of the pleural line and subjective image quality. Furthermore, correlation between NPLUS results and clinical data was assessed. RESULTS: A total of 1584 video loops from 66 patients, with a mean corrected gestational age of 33.8 weeks (SD 4.23) and weight of 1950g (SD 910), respectively, were analyzed. NPLUS score was estimated lower with the echo- and microconvex probe compared to the linear probe, with a coefficient of -2.95 (p < 0.001) and -1.09 (p = 0.19), respectively. Correlation between the pulse oximetric saturation/fraction of inspired oxygen ratio and NPLUS score was moderately strong and best using the microconvex probe (Spearman's rho = -0.63, p<0.001). CONCLUSION: Our results not only confirm the current recommendations, but also demonstrate the extent of the varying results when different probes are used. The differences we discovered call for caution in interpreting scores, especially in the context of guiding therapies and communicating prognoses. Finally, the correlation between NPLUS score and clinical parameters contributes to validating the use of this diagnostic tool.


Subject(s)
Lung , Ultrasonography , Humans , Infant, Newborn , Lung/diagnostic imaging , Prospective Studies , Ultrasonography/methods , Female , Male , Continuous Positive Airway Pressure
2.
Respir Res ; 25(1): 4, 2024 Jan 04.
Article in English | MEDLINE | ID: mdl-38178216

ABSTRACT

RATIONALE: Lung recruitment and continuous distending pressure (CDP) titration are critical for assuring the efficacy of high-frequency ventilation (HFOV) in preterm infants. The limitation of oxygenation (peripheral oxygen saturation, SpO2) in optimizing CDP calls for evaluating other non-invasive bedside measurements. Respiratory reactance (Xrs) at 10 Hz measured by oscillometry reflects lung volume recruitment and tissue strain. In particular, lung volume recruitment and decreased tissue strain result in increased Xrs values. OBJECTIVES: In extremely preterm infants treated with HFOV as first intention, we aimed to measure the relationship between CDP and Xrs during SpO2-driven CDP optimization. METHODS: In this prospective observational study, extremely preterm infants born before 28 weeks of gestation undergoing SpO2-guided lung recruitment maneuvers were included in the study. SpO2 and Xrs were recorded at each CDP step. The optimal CDP identified by oxygenation (CDPOpt_SpO2) was compared to the CDP providing maximal Xrs on the deflation limb of the recruitment maneuver (CDPXrs). RESULTS: We studied 40 infants (gestational age at birth = 22+ 6-27+ 5 wk; postnatal age = 1-23 days). Measurements were well tolerated and provided reliable results in 96% of cases. On average, Xrs decreased during the inflation limb and increased during the deflation limb. Xrs changes were heterogeneous among the infants for the amount of decrease with increasing CDP, the decrease at the lowest CDP of the deflation limb, and the hysteresis of the Xrs vs. CDP curve. In all but five infants, the hysteresis of the Xrs vs. CDP curve suggested effective lung recruitment. CDPOpt_SpO2 and CDPXrs were highly correlated (ρ = 0.71, p < 0.001) and not statistically different (median difference [range] = -1 [-3; 9] cmH2O). However, CDPXrs were equal to CDPOpt_SpO2 in only 6 infants, greater than CDPOpt_SpO2 in 10, and lower in 24 infants. CONCLUSIONS: The Xrs changes described provide complementary information to oxygenation. Further investigation is warranted to refine recruitment maneuvers and CPD settings in preterm infants.


Subject(s)
High-Frequency Ventilation , Infant, Extremely Premature , Humans , Infant, Newborn , Oscillometry , Lung , Lung Volume Measurements/methods , High-Frequency Ventilation/methods
SELECTION OF CITATIONS
SEARCH DETAIL