Semin Dial ; 34(1): 5-16, 2021 01.
Article En | MEDLINE | ID: mdl-32924202

Artificial intelligence (AI) is considered as the next natural progression of traditional statistical techniques. Advances in analytical methods and infrastructure enable AI to be applied in health care. While AI applications are relatively common in fields like ophthalmology and cardiology, its use is scarcely reported in nephrology. We present the current status of AI in research toward kidney disease and discuss future pathways for AI. The clinical applications of AI in progression to end-stage kidney disease and dialysis can be broadly subdivided into three main topics: (a) predicting events in the future such as mortality and hospitalization; (b) providing treatment and decision aids such as automating drug prescription; and (c) identifying patterns such as phenotypical clusters and arteriovenous fistula aneurysm. At present, the use of prediction models in treating patients with kidney disease is still in its infancy and further evidence is needed to identify its relative value. Policies and regulations need to be addressed before implementing AI solutions at the point of care in clinics. AI is not anticipated to replace the nephrologists' medical decision-making, but instead assist them in providing optimal personalized care for their patients.


Kidney Diseases , Nephrology , Artificial Intelligence , Clinical Decision-Making , Humans , Renal Dialysis/adverse effects
2.
Isotopes Environ Health Stud ; 42(1): 21-35, 2006 Mar.
Article En | MEDLINE | ID: mdl-16500752

Recent measurements of carbon isotopes in carbon dioxide using near-infrared, diode-laser-based cavity ring-down spectroscopy (CRDS) are presented. The CRDS system achieved good precision, often better than 0.2 per thousand, for 4% CO2 concentrations, and also achieved 0.15-0.25 per thousand precision in a 78 min measurement time with cryotrap-based pre-concentration of ambient CO2 concentrations (360 ppmv). These results were obtained with a CRDS system possessing a data rate of 40 ring-downs per second and a loss measurement of 4.0 x 10(-11) cm(-1) Hz(-1/2). Subsequently, the measurement time has been reduced to under 10 min. This standard of performance would enable a variety of high concentration (3-10%) isotopic measurements, such as medical human breath analysis or animal breath experiments. The extension of this ring-down to the 2 microm region would enable isotopic analysis at ambient concentrations, which, combined with the small size, robust design, and potential for frequent measurements at a remote site, make CRDS technology attractive for remote atmospheric measurement applications.


Air/analysis , Carbon Dioxide/chemistry , Carbon Isotopes/chemistry , Spectroscopy, Fourier Transform Infrared , Humans , Reproducibility of Results , Spectroscopy, Fourier Transform Infrared/instrumentation , Spectroscopy, Fourier Transform Infrared/methods
...