Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 10 de 10
1.
Appl Opt ; 62(16): E92-E95, 2023 Jun 01.
Article En | MEDLINE | ID: mdl-37706894

Flow characteristic properties in pipelines are determined from the temperature evolution, measured by fiber Bragg gratings, after transit of a thermal slug. Results analyze both laminar and turbulent flow regimes.

2.
J Prosthet Dent ; 125(3): 535-542, 2021 Mar.
Article En | MEDLINE | ID: mdl-32204928

STATEMENT OF PROBLEM: Information regarding the shrinkage kinetics and monomer conversion of dual-polymerized conventional and self-adhesive resin luting agents (RLA) in situ is lacking. PURPOSE: The purpose of this in vitro study was to evaluate the shrinkage strain and ratio of 1 conventional and 1 self-adhesive RLA by using fiber optic sensors based on Bragg gratings and Vickers hardness in the root canal. MATERIAL AND METHODS: The root canals of 34 single-rooted premolars were endodontically treated and assigned to 2 groups according to the RLA: RelyX ARC (ARC) and RelyX U200 (U200). Two Bragg grating sensors were attached to fiber posts (n=10), and both post and RLA were placed inside the root canal so that shrinkage strain and ratio values could be measured at the cervical and apical root thirds. For hardness analysis (n=7), two 1-mm-thick slices of each root-third (cervical and apical) were obtained, and 4 indentations were made on the RLA layer. The shrinkage strain and rate, as well as hardness data, were evaluated by using 2-way repeated-measures ANOVA followed by the Bonferroni post hoc test when a significant interaction between factors was detected (α=.05). RESULTS: The shrinkage strain and rate values of both RLAs were higher at the cervical third than those at the apical third. ARC showed higher shrinkage strain than U200 at the cervical third. The highest hardness values were observed at the cervical third, while ARC showed the lowest hardness values at the apical third. CONCLUSIONS: The shrinkage kinetics profile and hardness of self-adhesive RLA may differ from those of conventional RLA depending on the root third.


Dental Bonding , Post and Core Technique , Dental Cements , Dental Pulp Cavity , Dentin , Kinetics , Materials Testing , Polymerization , Resin Cements
3.
Comput Methods Biomech Biomed Engin ; 23(14): 1127-1137, 2020 Nov.
Article En | MEDLINE | ID: mdl-32657618

Contraction due to polymerization of dental resin can cause failure on the adhesive interfaces, can lead to problems such as the appearance of gaps in the interfaces, postoperative sensitivity, pulp damage and the return of the caries. The objective of this work is the study of stresses on the dental adhesive that are generated by the process shrinkage of resin associated with biting forces. A laboratory experiment measured the strains and temperature inside the FiltekTM Bulk Fill Flow resin during the process of polymerization using Fiber Bragg Grating sensors in an ex vivo tooth. From tomographic images a three-dimensional geometric model of the tooth was reconstructed. A pre-tension was calibrated to simulate the residual contraction on the resin 3 D model. Finally, an Finite Element Method analysis was performed to access the adhesive stresses at the interface enamel/dentin with the adhesive, considering as loading the residual polymerization contraction of the dental resin and also biting loads. The model was able to represented the strain obtained in the laboratory experiment. The results of the stress analysis shows that the outer regions of adhesive are more prone to failure, as veried by dental surgeons in clinical practice.


Composite Resins/chemistry , Finite Element Analysis , Optics and Photonics/methods , Adult , Biomechanical Phenomena , Bite Force , Calibration , Dental Bonding , Dental Stress Analysis , Humans , Imaging, Three-Dimensional , Materials Testing , Polymerization , Pressure , Temperature , Young Adult
4.
Sensors (Basel) ; 19(18)2019 Sep 04.
Article En | MEDLINE | ID: mdl-31487885

Use of fiber Bragg gratings (FBGs) to monitor high temperature (HT) applications is of great interest to the research community. Standard commercial FBGs can operate up to 600 ∘ C. For applications beyond that value, specific processing of the FBGs must be adopted to allow the grating not to deteriorate. The most common technique used to process FBGs for HT applications is the regeneration procedure (RP), which typically extends their use up to 1000 ∘ C. RP involves a long-term annealing of the FBGs, to be done at a temperature ranging from 550 to 950 ∘ C. As at that temperature, the original coating of the FBGs would burn out, they shall stay uncoated, and their brittleness is a serious concern to deal with. Depositing a metal coating on the FBGs prior to process them for RP offers an effective solution to provide them with the necessary mechanical strengthening. In this paper, a procedure to provide the FBG with a bimetallic coating made by copper and nickel electrodeposition (ED) is proposed, discussing issues related to the coating morphology, adherence to the fiber, and effects on the grating spectral response. To define the processing parameters of the proposed procedure, production tests were performed on dummy samples which were used for destructive SEM-EDS analysis. As a critical step, the proposed procedure was shown to necessitate a heat treatment after the nickel ED, to remove the absorbed hydrogen. The spectral response of the FBG samples was monitored along the various steps of the proposed procedure and, as a final proof test for adherence stability of the bimetallic coating, along a heating/cooling cycle from room temperature to 1010 ∘ C. The results suggest that, given the emergence of Kirkendall voids at the copper-nickel interface, occurring at the highest temperatures (700-1010 ∘ C), the bimetallic layer could be employed as FBG coating up to 700 ∘ C.

5.
Full dent. sci ; 9(35): 34-39, 2018. tab, graf
Article Pt | BBO | ID: biblio-988320

O objetivo do estudo foi avaliar a alteração de temperatura nos ossos cortical e medular gerados pela resina acrílica na união dos transferentes por meio das redes de Bragg. Foram selecionados dois implantes cone morse Titamax (Neodent) 4 mm x 15 mm. Os implantes foram inseridos em um osso artificial da marca Sawbones, de acordo com as instruções do fabricante, cuja localização dos pilares foi referente aos dentes 44 e 46 com ausência do dente 45. Sobre os implantes foram instalados transferentes para a técnica aberta. Os transferentes foram esplintados por meio de um fio dental e aplicação de resina acrílica pela técnica de Nealon. Foram selecionadas duas resinas acrílicas: Duralay e GC Pattern LS. Dois sensores de fibra ótica foram posicionados, sendo um próximo à região cervical e outro na região apical do implante. Os sensores mensuraram a transferência de calor para o osso cortical e medular com o auxílio de uma pasta térmica (Implastec). Os dados foram submetidos à análise estatística por meio dos testes de normalidade de Shapiro-Wilk, ANOVA a dois critérios e teste de múltiplas comparações post hoc LSD (p<0,05). Foram encontradas diferenças significativas entre Duralay apical eGC Pattern LS cervical, GC Pattern LS cervical eGC Patternapical (p<0,05). As redes de Bragg apresentaram-se sensíveis para a mensuração da transferência de temperatura do transferente para os ossos cortical e medular. A partir dos resultados obtidos, pode-se afirmar que não há risco de necrose óssea (AU).


The purpose of the study was to evaluate the temperature change in the cortical and medullary bones generated by the acrylic resin in the union of transferents through the Bragg's grating. Two cone morse Titamax (Neodent) 4 mm x 15 mm implants were selected. The implants were inserted into a Sawbones artificial bone according to the manufacturer's instructions, abutment location were teeth 44 and 46 with absence of tooth 45. On the implants tranfers were installed for the open technique. The transfers were splined by means of a dental floss and acrylic resin application by the Nealon technique. Two acrylic resins were selected: Duralay and GC Pattern LS. Two fiber optic sensors were positioned, one near the cervical region and other at the implant apical region. The sensors measured the heat transfer to the cortical and medullary bones with the help of a thermal paste (Implastec). Data were submitted to statistical analysis using Shapiro-Wilk normality tests, two way ANOVA, and post hoc LSD multiple comparisons (p <0.05). Significant differences were found between Duralay apical and GC Pattern LS cervical, GC Pattern LS cervical and GC apical Pattern (p <0.05). The Bragg's grating were sensitive to temperature transference measurement from transfers to the cortical and medullary bones. From the results obtained, it is possible to ssure that there is no risk of bone necrosis (AU).


Acrylic Resins , Bone and Bones , Dental Implants , Dental Prosthesis, Implant-Supported , Body Temperature Changes , Brazil , Analysis of Variance , Data Interpretation, Statistical , Fiber Optic Technology/methods
6.
Appl Opt ; 56(3): 510-514, 2017 Jan 20.
Article En | MEDLINE | ID: mdl-28157907

The femtosecond-laser pulse inscription and characterization of fiber Bragg gratings for operation at visible wavelengths was performed using several types of optical fibers, including single-mode and graded-index fibers designed for near-infrared wavelengths. The obtained bandwidths are very narrow (∼0.12-0.36 nm) for the used exposure conditions, even in graded-index fibers. Thermal and strain characterization was performed, with results about half of those found for C-band gratings. The wavelength dependence of the sensitivity is compared with a Sellmeier model.

7.
J Prosthet Dent ; 116(4): 570-576, 2016 Oct.
Article En | MEDLINE | ID: mdl-27157607

STATEMENT OF PROBLEM: The behavior and magnitude of the deformations that occur during polymerization and the behavior of the luting agents of glass fiber posts inside the root canal require quantification. PURPOSE: The purpose of this in vitro study was to investigate the in situ polymerization shrinkage, degree of conversion, and bond strength inside the root canal of resin cements used to lute fiber posts. MATERIAL AND METHODS: Thirty maxillary canines were prepared to lute fiber posts. The teeth were randomly divided into 2 groups (n=15) according to the cementation system used, which included ARC, the conventional dual-polymerized resin cement RelyX ARC, and the U200 system, a self-adhesive resin cement, RelyX U200. Two fiber optic sensors with recorded Bragg gratings (FBG) were attached to each post before inserting the resin cement inside the root canal to measure the polymerization shrinkage (PS) of the cements in the cervical and apical root regions (µÎµ). Specimens were sectioned (into cervical and apical regions) to evaluate bond strength (BS) with a push-out test and degree of conversion (DC) with micro-Raman spectroscopy. Data were statistically analyzed with 2-way ANOVA and the Tukey honestly significant difference post hoc test (α=.05). RESULTS: The ARC and U200 system showed similar PS values (-276.4 ±129.2 µÎµ and -252.1 ±119.2 µÎµ, respectively). DC values from ARC were higher (87.5 ±2.7%) than those of U200 (55.9 ±9.7%). The cervical region showed higher DC values (74.8 ±15.2%) and PS values (-381.6 ±53.0 µÎµ) than those of the apical region (68.5 ±20.1% and -146.9 ±43.5 µÎµ, respectively) for both of the resin cements. BS was only statistically different between the cervical and apical regions for ARC (P<.05). CONCLUSIONS: The ARC system showed the highest PS and DC values compared with U200; and for both of the resin cements, the PS and DC values were higher at the cervical region than at the apical region of the canal root. BS was higher in the cervical region only for ARC.


Dental Bonding/methods , Dental Cements/therapeutic use , Post and Core Technique , Resin Cements/therapeutic use , Dental Bonding/standards , Dental Marginal Adaptation , Dental Stress Analysis , Humans , In Vitro Techniques , Polymerization
8.
Sensors (Basel) ; 15(11): 28456-71, 2015 Nov 11.
Article En | MEDLINE | ID: mdl-26569250

Pattern classification of ingestive behavior in grazing animals has extreme importance in studies related to animal nutrition, growth and health. In this paper, a system to classify chewing patterns of ruminants in in vivo experiments is developed. The proposal is based on data collected by optical fiber Bragg grating sensors (FBG) that are processed by machine learning techniques. The FBG sensors measure the biomechanical strain during jaw movements, and a decision tree is responsible for the classification of the associated chewing pattern. In this study, patterns associated with food intake of dietary supplement, hay and ryegrass were considered. Additionally, two other important events for ingestive behavior were monitored: rumination and idleness. Experimental results show that the proposed approach for pattern classification is capable of differentiating the five patterns involved in the chewing process with an overall accuracy of 94%.


Feeding Behavior/classification , Feeding Behavior/physiology , Fiber Optic Technology/instrumentation , Machine Learning , Mastication/physiology , Algorithms , Animals , Biomechanical Phenomena , Equipment Design , Fiber Optic Technology/methods , Ruminants
9.
Sensors (Basel) ; 12(9): 11957-65, 2012.
Article En | MEDLINE | ID: mdl-23112693

The aim of this work is to show the possibility of using fiber optic sensors to instrument inside parts of an artificial maxilla and measure internal tension transmitted by the orthodontic and orthopedic appliances to the dentition and the adjacent bone. Bragg gratings written in a standard optical fiber were used to monitor the maxillary teeth and a multiplexed fiber was used to monitor the surface of the maxillary bone, transversally to the longest axis of the teeth. A Universal Test Machine was used to evaluate the sensitivity of the sensor to the vertical and lateral forces applied on the teeth. A wavelength shift of approximately 0.30 nm was detected when applying loads ranging from 0 to 20 N. By applying forces using the standard orthodontic appliances installed on the dentition it was possible to detect a range of forces between 0.025 N to 0.035 N during the activation of the arch wire and extra-oral forces. The use of the internal sensors in an artificial model made possible the monitoring of the resulting forces on the internal parts of the teeth and at the position where the strain takes place within the maxilla. The sensors detected that the orthodontic forces were not transmitted to the surface of the maxilla. This information is important to elucidate and to correlate undesirable effects as tooth root absorption and local pain during the orthodontic treatment.


Maxilla/physiology , Optical Fibers , Orthodontic Appliances , Orthopedic Equipment , Bone and Bones/physiology , Humans , Root Resorption/diagnosis , Tooth/physiology , Tooth Root/physiology
10.
Appl Opt ; 48(31): G38-43, 2009 Nov 01.
Article En | MEDLINE | ID: mdl-19881643

We study the recording of permanent Bragg gratings on surface-colored lithium fluoride (LiF) crystals by using the interference pattern of a continuous-wave UV argon-ion laser operating at 244 nm. Gratings with spatial periodicity ranging from 400 to 1000 nm are written by using a phase-mask interferometer and are stable for several months after the writing process. Absorption and photoluminescence spectra show the bleaching of primary F and F -aggregate laser-active color centers as a result of the process. Confocal microscopy is used to determine the pitch and the profile of the fluorescent gratings. The UV laser-induced optical bleaching in highly colored LiF ultrathin layers is responsible for the periodic spatial modulation of absorption and photoemission properties that characterize the gratings. In the colored surface layer, a reduction of as much as 50% of the initial color-center-induced refractive-index increase has been estimated in the bleached areas.

...