Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 31
Filter
1.
Am J Ophthalmol ; 2024 Jun 18.
Article in English | MEDLINE | ID: mdl-38901720

ABSTRACT

PURPOSE: To evaluate ophthalmological, neurological, radiological, and laboratory data in patients with multiple sclerosis (MS) and to identify new ophthalmological factors that could be helpful as biomarkers of the disease, potentially leading to an earlier prediction of disease course and disability progression. DESIGN: Retrospective, cross-sectional-study. METHODS: Best-corrected visual acuity (BCVA), ophthalmological biomicroscopy of the anterior segment and fundus, structural optical coherence tomography (OCT) with retinal nerve fiber layer (RNFL) and ganglion cell complex (GCC), and OCT Angiography (OCTA) with vascular density (VD) were performed. The following clinical and neuro-radiological features were assessed: MS phenotype, disease duration, clinical severity, type of treatment, and T2-weighted lesion load plus T1-weighted Gd+-enhancing lesion number on the last brain and spinal cord MRI. RESULTS: One hundred and six patients (212 eyes) were analyzed. Sixty-six of them (62.2 %) had MS and 40 (37.8%) were matched healthy controls (HCs). patients with MS showed lower RNFL, GCC, and VD in the radial peripapillary capillary plexus than controls in both eyes (p<0.05). By Performing a logistic regression with a distinct MS outcome for both eyes, we were able to demonstrate that the value that was most predictive of MS was the average GCC thickness (p=0.009). Regression analysis demonstrated that patients with a higher T2-weighted lesions showed a lower RNFL thickness value and reduced GCC and VD values than those with a low lesion load (p<0.01 and p<0.05, respectively). Similarly, relapsing MS patients showed lower RNFL values (p<0.05). CONCLUSIONS: Several OCT- and OCTA-optic nerve parameters could be useful prognostic biomarkers for the MS disease course in clinical practice. However, it is necessary to do additional research with larger sample sizes in order to validate these findings.

2.
Graefes Arch Clin Exp Ophthalmol ; 262(7): 2181-2187, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38326628

ABSTRACT

PURPOSE: To understand whether the preoperative morphology of the posterior corneal surface influences the rate of re-bubbling after Descemet membrane endothelial keratoplasty (DMEK). METHODS: After retrospectively analyzing the medical records of patients undergoing DMEK, in this multicentric cross-sectional study, we performed a binomial logistic regression analysis to assess significant predictors of re-bubbling and re-transplantation after surgery. Analyzed parameters included the preoperative diagnosis, anterior and posterior surface K1/K2, central corneal thickness, posterior Q value, and other posterior corneal surface parameters evaluated on the elevation maps produced by anterior segment optical coherence tomography. Results were stratified based on the surgeons' experience. RESULTS: We included 202 eyes of 202 patients with a mean age of 69.5 ± 12.4 years; 154 eyes were operated by a high-volume surgeon and 48 by one with less experience; 48 eyes (23.8%) underwent ≥ 1 re-bubbling and 14(6.9%) ≥ 1 re-transplantation. The presence of positive/less-negative posterior corneal irregularities and irregularities with greater absolute height had a significantly higher risk of re-bubbling in both the expert and less expert group (OR = 2.85 and 1.42, OR = 3.22 and 3.01, respectively, p < 0.05), whereas more negative posterior K1 and K2 were significant risk factors only in the former group (OR = 0.67 and 0.55, respectively, p < 0.05). Endothelial decompensation other than Fuchs and pseudophakic bullous keratopathy, more negative posterior Q values and smaller distances between center, and the highest/lowest posterior corneal surface irregularity correlated with an increased risk of graft failure (OR 1.23, 1.21, and 1.29, respectively, p < 0.05). CONCLUSION: Posterior corneal surface morphology significantly influences the risk of re-bubbling after DMEK.


Subject(s)
Descemet Stripping Endothelial Keratoplasty , Tomography, Optical Coherence , Visual Acuity , Humans , Descemet Stripping Endothelial Keratoplasty/methods , Aged , Male , Female , Retrospective Studies , Cross-Sectional Studies , Tomography, Optical Coherence/methods , Endothelium, Corneal/pathology , Follow-Up Studies , Reoperation , Cornea/diagnostic imaging , Cornea/pathology , Graft Survival/physiology , Risk Factors , Fuchs' Endothelial Dystrophy/surgery , Fuchs' Endothelial Dystrophy/diagnosis , Postoperative Complications , Middle Aged , Aged, 80 and over
3.
Eur J Ophthalmol ; 34(2): 549-557, 2024 Mar.
Article in English | MEDLINE | ID: mdl-37401268

ABSTRACT

PURPOSE: To analyze differences in refractive outcome Δ (difference between postoperative and expected refractive error) and in anterior segment changes between cataract surgery patients and combined phacovitrectomy patients. We also aimed to provide a corrective formula allowing to minimise the refractive outcome Δ in combined surgery patients. METHODS: Candidates for phacoemulsification and combined phacovitrectomy (respectively PHACO and COMBINED groups) were prospectively enrolled in two specialised centres. Patients underwent best corrected visual acuity (BCVA) assessment, ultra-high speed anterior segment optical coherence tomography (OCT), gonioscopy, retinal OCT, slit lamp examination and biometry at baseline, 6 weeks postoperatively and 3 months postoperatively. RESULTS: No differences in refractive Δ, refractive error and anterior segment parameters were noted between PHACO and COMBINED group (109 and 110 patients respectively) at 6 weeks. At 3 months, COMBINED group showed a spherical equivalent of -0.29 ± 0.10 D versus -0.03 ± 0.15 D in PHACO group (p = 0.023). COMBINED group showed a significantly higher Crystalline Lens Rise (CLR), angle-to-angle (ATA) and anterior chamber width (ACW) and a significantly lower anterior chamber depth (ACD) and refractive Δ with all 4 considered formulas at 3 months. For IOL power lower than 15, a hyperopic shift was observed instead. CONCLUSIONS: Anterior segment OCT suggests anterior displacement of the effective lens position in patients undergoing phacovitrectomy. A corrective formula can be applied to IOL power calculation to minimize undesired refractive error.


Subject(s)
Cataract Extraction , Lenses, Intraocular , Phacoemulsification , Refractive Errors , Humans , Lens Implantation, Intraocular , Refraction, Ocular , Cataract Extraction/methods , Phacoemulsification/methods , Biometry/methods , Retrospective Studies
4.
Am J Ophthalmol Case Rep ; 32: 101949, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37942051

ABSTRACT

Purpose: To evaluate characteristic imaging findings and functional outcomes of Cilioretinal Artery Occlusion (CLRAO) associated with giant cell arteritis (GCA). Observations: We report the case of a 70-year-old woman presenting with sudden vision loss caused by a GCA-associated-CLRAO in her left eye (LE). A thorough ophthalmologic examination together with optical coherence tomography (OCT), OCT-Angiography (OCT-A), fluorescein angiography and fundus autofluorescence were performed. At presentation, the best corrected visual acuity in the LE was 20/200 and funduscopic examination revealed optic disc edema associated with retinal whitening along the area perfused by the CLRA. After 1 month, OCT and OCT-A revealed an improvement of the retinal edema and a partial reduction of the non-perfused areas in the superficial and deep capillary plexuses, as well as in the outer retina and in the choriocapillaris. Fluorescein angiography showed a reduction in the perfusion of the affected area, a delayed perfusion of the temporal sector of the optic disc, as well as areas of choroidal hypoperfusion in the peripheral temporal retina. The patient's visual acuity did not change during the follow up. Conclusion and importance: Despite a partial recanalization of the occluded vasculature being possible after GCA-associated-CLRAO, the patient's visual prognosis remains poor.

5.
Front Med (Lausanne) ; 10: 1085280, 2023.
Article in English | MEDLINE | ID: mdl-36950509

ABSTRACT

Purpose: To analyze the objective and subjective visual performances of a new hybrid refractive/aspheric extended depth of focus (EDOF) intraocular lens (IOL). Methods: In this monocentric prospective study patients with bilateral cataracts underwent cataract surgery and were implanted with a Lucidis IOL (SAV-IOL SA, Neuchâtel, Switzerland) in both eyes, 1 week apart from each other. At 3 months from implantation postoperative evaluations included monocular and binocular uncorrected and distance-corrected distant (4 m), intermediate (80 cm, 67 cm) and near (40 cm) visual acuities (UDVA/DCVA, UI80-67VA/DCI80-67VA, UNVA/DCNVA), binocular defocus curves, halometry, contrast sensitivity and objective quality-of-vision measurements. Also, patients were also asked to complete the national eye institute refractive error quality of life (NEI-RQL-42) questionnaire. Results: Twenty-five patients (50 eyes) were included. The mean postoperative binocular UDVA, UI80VA, UI67VA and UNVA were-0.02 ± 0.13, 0.05 ± 0.09, 0.05 ± 0.08 and 0.03 ± 0.1 LogMar, and did not significantly differ from their corrected counterparts. On binocular defocus curves a VA ≥0.05LogMar was found between +0.50 and - 2.50 D of vergence, whereas the mean distance from the central stimulus on halometry was 1.23 ± 0.01. Mean ocular and corneal radical mean square at 4 mm were 0.31 ± 0.28 and 0.19 ± 0.07, respectively; whereas the mean Strehl ratio was 0.2 ± 0.09. Conclusion: Lucidis IOLs demonstrated excellent visual performances, especially at close distances while maintain good quality of vision, contrast sensitivity, and overall patient-satisfaction.

6.
J Clin Med ; 12(5)2023 Mar 02.
Article in English | MEDLINE | ID: mdl-36902780

ABSTRACT

Purpose. To revise the current literature on FIL SSF (Carlevale) intraocular lens, previously known as Carlevale lens, and to compare their outcomes with those from other secondary IOL implants. Methods. We performed a peer review of the literature regarding FIL SSF IOLs until April 2021 and analyzed the results only of articles with a minimum of 25 cases and a follow-up of at least 6 months. The searches yielded 36 citations, 11 of which were abstracts of meeting presentations that were not included in the analysis because of their limited data. The authors reviewed 25 abstracts and selected six articles of possible clinical relevance to review in full text. Of these, four were considered to be sufficiently clinically relevant. Particularly, we extrapolated data regarding the pre- and postoperative best corrected visual acuities (BCVA) and the complications related to the procedure. The complication rates were then compared with those from a recently published Ophthalmic Technology Assessment by the American Academy of Ophthalmology (AAO) on secondary IOL implants. Results. Four studies with a total of 333 cases were included for results analysis. The BCVA improved in all cases after surgery, as expected. Cystoid macular edema (CME) and increased intraocular pressure were the most common complications, with an incidence of up to 7.4% and 16.5%, respectively. Other IOL types from the AAO report included anterior chamber IOLs, iris fixation IOLs, sutured iris fixation IOLs, sutured scleral fixation IOLs, and sutureless scleral fixation IOLs. There was no statistically significant difference in the rates of postoperative CME (p = 0.20), and vitreous hemorrhage (p = 0.89) between other secondary implants and the FIL SSF IOL, whereas the rate of retinal detachment was significantly less with FIL SSF IOLs (p = 0.04). Conclusion. The results of our study suggest the implantation of FIL SSF IOLs is an effective and safe surgical strategy in cases where there is a lack of capsular support. In fact, their outcomes seem to be comparable to those obtained with the other available secondary IOL implants. According to published literature, the FIL SSF (Carlevale) IOL provides favorable functional results with a low rate of postoperative complications.

7.
Can J Ophthalmol ; 58(2): 162-167, 2023 04.
Article in English | MEDLINE | ID: mdl-34562380

ABSTRACT

OBJECTIVE: To compare surgical efficiency, visual and physical comfort, and safety profile of the ARTEVO 800 Digital Microscope (Carl Zeiss Meditec AG, Jena, Germany) and the Ngenuity 3D Visualization System (Alcon Laboratories Inc, Fort Worth, TX) in cataract surgery. DESIGN: Cross-sectional study. PARTICIPANTS: One hundred consecutive phacoemulsification cataract surgeries performed by five surgeons from June 1, 2020, to November 1, 2020. METHODS: For each case, the surgeons answered a 2-section questionnaire (before and after intervention) to collect data on cataract severity or grade, surgical risk, chosen three-dimensional (3D) visualization system, surgical complications, and the visual or physical discomfort experienced during the procedure. RESULTS: Each of the 5 surgeons performed 20 surgeries (N = 100) using either the ARTEVO 800 Digital Microscope (N = 50) or the Ngenuity Visualization System (N = 50). Mean duration of the surgical procedure was 17.07 ± 4.80 minutes, and none of the surgeons ever switched to the classical microscope. In addition, 40% of surgeries were considered at low risk, 30% at intermediate risk, and 30% at high risk. The Zoom, Focus, and XY commands were used 1-3 times, respectively, during 76 (p = 0.34), 73 (p = 0.49), and 76 (p = 0.64) interventions. Surgical uncertainty and operative fluency were similar using both systems (p = 0.53 and p = 0.19). We observed 14 intraoperative complications, 9 using Ngenuity and 5 using the ARTEVO 800. Surgeon's visual comfort (p = 0.79), colour or brightness perception (p = 0.82), and visual impairment (p = 0.62) during surgery were similar for both systems. Headache, backache, and other musculoskeletal problems were reported, respectively, after 14 (p = 0.79), 11 (p = 0.99), and 8 (p = 0.44) procedures. CONCLUSION: Both the Ngenuity 3D Visualization System (Alcon Laboratories Inc) and the ARTEVO 800 Digital Microscope (Carl Zeiss Meditec AG) provided comparable operative speed and overall surgical comfort during cataract surgery.


Subject(s)
Cataract , Phacoemulsification , Humans , Phacoemulsification/methods , Imaging, Three-Dimensional/methods , Tomography, Optical Coherence , Cross-Sectional Studies
8.
Eur J Ophthalmol ; 33(6): NP92-NP95, 2023 Nov.
Article in English | MEDLINE | ID: mdl-36503313

ABSTRACT

PURPOSE: To report the case of a patient who presented with a peripapillary retinal detachment caused by pathological myopia. OBSERVATIONS: A 73-year-old female with a clinical history of high myopia was admitted to our ophthalmic department complaining of vision loss in her right eye. Her best-corrected visual acuity was 20/25 in the right eye and 20/400 in the left eye. The refractive error was -9.00 D in both eyes. The anterior segment and pupillary reflex were normal. Dilated fundus examination revealed myopic retinopathy in both eyes and a yellow peripapillary lesion, distinct from the myopic conus and encircling almost the whole optic disc, in her right eye. The left eye displayed macular atrophy with macular pigmentation due to a previous myopic choroidal neovascularization. Optical coherence tomography showed a localized retinal detachment in the peripapillary area, adjacent to the inferior edge of the optic disc, giving a strange "seagull wings" appearance. CONCLUSIONS AND IMPORTANCE: In case of peripapillary neuroepithelial detachment the presence of PDPM in high myopic patients should always be excluded. Further research is due in order to better understand this clinical entity's pathogenesis and prognosis.

9.
Am J Ophthalmol Case Rep ; 29: 101763, 2023 Mar.
Article in English | MEDLINE | ID: mdl-36483519

ABSTRACT

Purpose: To describe the microscopic epithelial changes and the clinical outcomes of a patient treated with amniotic membrane eye drops (AMED) because of a persistent epithelial defect (PED) and a partial limbal stem cell deficiency (LSCD) after simple limbal epithelial transplantation (SLET) and deep anterior lamellar keratoplasty (DALK). Observations: A 72-year-old patient, who had previously undergone SLET and DALK due to a total LSCD, presented with a PED related to a partial LSCD, and was treated with AMED for one month. We evaluated the patient's visual acuity, the Oxford grading scale, the Wong-Baker Pain Rating Scale, and in vivo confocal microscopy, both at baseline and 3 months after the end of treatment. Visual acuity improved from 0.5 to 0.4 LogMAR, the Oxford grading scale changed from grade III to grade I and the Wong-Baker Pain Rating Scale from grade 4 to grade 1. The corneal surface, which initially showed conjunctival characteristics over approximately 50% of the whole area, consisted mainly (75%) of mature corneal epithelium 3 months after the end of treatment. Conclusions and importance: While improving symptoms and clinical characteristics, AMED was also able to restore the normal corneal epithelium's morphology in a case of partial LSCD after SLET and DALK.

10.
Retina ; 43(2): 173-181, 2023 02 01.
Article in English | MEDLINE | ID: mdl-36228144

ABSTRACT

PURPOSE: To predict improvement of best-corrected visual acuity (BCVA) 1 year after pars plana vitrectomy for epiretinal membrane (ERM) using artificial intelligence methods on optical coherence tomography B-scan images. METHODS: Four hundred and eleven (411) patients with Stage II ERM were divided in a group improvement (IM) (≥15 ETDRS letters of VA recovery) and a group no improvement (N-IM) (<15 letters) according to 1-year VA improvement after 25-G pars plana vitrectomy with internal limiting membrane peeling. Primary outcome was the creation of a deep learning classifier (DLC) based on optical coherence tomography B-scan images for prediction. Secondary outcome was assessment of the influence of various clinical and imaging predictors on BCVA improvement. Inception-ResNet-V2 was trained using standard augmentation techniques. Testing was performed on an external data set. For secondary outcome, B-scan acquisitions were analyzed by graders both before and after fibrillary change processing enhancement. RESULTS: The overall performance of the DLC showed a sensitivity of 87.3% and a specificity of 86.2%. Regression analysis showed a difference in preoperative images prevalence of ectopic inner foveal layer, foveal detachment, ellipsoid zone interruption, cotton wool sign, unprocessed fibrillary changes (odds ratio = 2.75 [confidence interval: 2.49-2.96]), and processed fibrillary changes (odds ratio = 5.42 [confidence interval: 4.81-6.08]), whereas preoperative BCVA and central macular thickness did not differ between groups. CONCLUSION: The DLC showed high performances in predicting 1-year visual outcome in ERM surgery patients. Fibrillary changes should also be considered as relevant predictors.


Subject(s)
Epiretinal Membrane , Humans , Epiretinal Membrane/diagnosis , Epiretinal Membrane/surgery , Artificial Intelligence , Retrospective Studies , Visual Acuity , Retina , Tomography, Optical Coherence/methods , Vitrectomy/methods
11.
Eur J Ophthalmol ; : 11206721221143165, 2022 Dec 12.
Article in English | MEDLINE | ID: mdl-36503334

ABSTRACT

PURPOSE: To study the post-operative refractive error (RE) of patients undergoing combined phaco-vitrectomy and to find out which intraocular lens (IOL)-power formula had the best refractive outcomes. METHODS: In this retrospective multicentric study we compared the preoperative expected target with the postoperative RE of patients undergoing combined phaco-vitrectomy due to vitreomacular traction, macular pucker, full thickness macular hole or lamellar macular hole. A multinomial logistic regression was performed to compare the postoperative REs and the differences between expected and postoperative REs among the SRK-T, Olsen's and Holladay-2 formulas. The correlation between the difference in REs and IOL-power was also studied. RESULTS: Sixty-seven eyes with a mean axial length of 23.73 ± 1.21 mm were included. Forty-two (63%), 14 (21%) and 11 (16%) eyes were implanted with an IOL that was calculated respectively with SRK-T, Olsen's and the Holladay-2 formula. The mean preoperative expected- and post-operative REs were -0.16 ± 0.12D and -0.48 ± 0.17, respectively (p = 0.045). SRK-T and Holladay-2 formulas led to a significant myopic shift whereas Olsen's caused a significant hyperopic error, independently from the IOL power. CONCLUSION: Independently from the IOL power, none of the analyzed formulas is precise at calculating the post-operative RE.

12.
Life (Basel) ; 12(12)2022 Nov 30.
Article in English | MEDLINE | ID: mdl-36556364

ABSTRACT

Macular neovascularization (MNV) and geographic atrophy can complicate age-related macular degeneration (AMD) and lead to severe visual acuity reduction. Despite the medical treatments available, with a defect in the retinal pigmented epithelium (RPE) there is no possibility of restoring acceptable visual acuity. We evaluated postoperative outcomes in patients affected by advanced AMD who underwent subretinal implant of the human amniotic membrane (hAM) as a source of pluripotent stem cells. This retrospective, consecutive, non-randomized interventional study included 23 eyes of 21 patients affected by AMD complicated by MNV, and five eyes of five patients affected by geographic atrophy. All eyes underwent a pars plana vitrectomy, neovascular membrane removal for the MNV group, a subretinal implant of hAM, and gas tamponade, and were followed for 12 months. The primary study outcome was visual acuity improvement. Secondary outcomes were postoperative complications, OCT-angiography parameters correlated with best-corrected visual acuity (BCVA) and MNV recurrence. The mean preoperative BCVA was 1.9 logMAR, and the mean final BCVA value was 1.2 logMAR. In the MNV group, the mean BCVA improved from 1.84 logMAR to 1.26 logMAR, and from 1.84 logMAR to 1.32 logMAR in the geographic atrophy group. No MNV recurrence was evident in 12 months of follow-up. An OCT-angiography scan was used to evaluate the retinal vascularization in the treated eye, which showed a high correlation between BCVA and deep vascular density. This study demonstrates the hAM potential and safety in promoting a partial restoration of retinal function together with an increase in visual acuity.

13.
Am J Ophthalmol Case Rep ; 28: 101719, 2022 Dec.
Article in English | MEDLINE | ID: mdl-36217439

ABSTRACT

Purpose: To describe a case of bilateral pseudophakic malignant glaucoma treated with a new variant of irido-zonulo-hyaloid-vitrectomy. Observations: A patient who developed refractory bilateral pseudophakic malignant glaucoma underwent an irido-zonulo-hyaloid-vitrectomy via the anterior chamber in both eyes, one 2-months apart from the other. The procedure involved the use of an 18 Gauge needle to perform a straight vertical irido-zonulo-hyaloidotomy and a 25 Gauge vitreous cutter to complete the vitrectomy. The intraocular pressure was recorded on day 1, day 7, day 14, then monthly until 6 months postoperatively, whereas an ultrasound biomicroscopy of the anterior chamber was performed on day 1 and 6 months after the operation. The malignant glaucoma resolved in both eyes with no intra- nor post-operative complications. At 6 months from the surgeries none of the eyes developed recurrences. Conclusions: The new variant of irido-zonulo-hyaloid-vitrectomy we propose for the management of refractory pseudophakic malignant glaucoma resulted to be a safe and effective technique.

14.
Jpn J Ophthalmol ; 66(6): 518-526, 2022 Nov.
Article in English | MEDLINE | ID: mdl-36301445

ABSTRACT

PURPOSE: To determine the efficacy of using a human amniotic membrane to close macular hole retinal detachment in highly myopic eyes. STUDY DESIGN: Prospective, consecutive, nonrandomized interventional study. METHODS: We included 19 high myopic eyes from 19 patients affected by macular hole retinal detachment who had already undergone vitrectomy with internal limiting membrane peeling. The patients underwent vitrectomy with amniotic membrane transplant. RESULTS: Primary success was achieved after 3 months in 89.5% (17 of 19 eyes) and final macular hole closure was obtained in 94.7% (18 of 19 eyes) of the patients. The final retinal reattachment rate was 100%. The final 12-month mean BCVA improved from 20/2000 (2 logMAR) to 20/250 (1.1 logMAR). OCT-angiography revealed a high correlation between the superficial and deep capillary plexus and the final BCVA. CONCLUSION: Human amniotic membrane patches can effectively repair macular hole retinal detachment in high myopic eyes in terms of anatomic results and BCVA recovery.


Subject(s)
Myopia, Degenerative , Retinal Detachment , Retinal Perforations , Humans , Retinal Perforations/diagnosis , Retinal Perforations/etiology , Retinal Perforations/surgery , Retinal Detachment/diagnosis , Retinal Detachment/etiology , Retinal Detachment/surgery , Prospective Studies , Amnion , Myopia, Degenerative/complications , Myopia, Degenerative/diagnosis , Visual Acuity , Retrospective Studies , Vitrectomy/methods , Basement Membrane/surgery , Tomography, Optical Coherence
15.
J Clin Med ; 11(14)2022 Jul 06.
Article in English | MEDLINE | ID: mdl-35887700

ABSTRACT

(1) Purpose: To determine the characteristics of macular epiretinal membranes (ERM) using non-invasive retromode imaging (RMI) and to compare retromode images with those acquired via fundus autofluorescence (FAF) and fundus photography. (2) Methods: Prospective observational case-series study including patients with macular ERM with no other ocular disease affecting their morphology and/or imaging quality. We compared RMI, FAF and fundus photography features by cropping and overlapping images to obtain topographic correspondence. (3) Results: In total, 21 eyes (21 patients) affected by ERM were included in this study. The mean area of retinal folds detected by RMI was significantly higher than that detected by FAF (11.85 ± 3.92 mm2 and 5.67 ± 2.15 mm2, respectively, p < 0.05) and similar to that revealed by fundus photography (11.85 ± 3.92 mm2 and 10.58 ± 3.45 mm2, respectively, p = 0.277). (4) Conclusions: RMI appears to be a useful tool in the evaluation of ERMs. It allows for an accurate visualization of the real extension of the retinal folds and provides a precise structural assessment of the macula before surgery. Clinicians should be aware of RMI's advantages and should be able to use them to warrant a wide range of information and, thus, a more personalized therapeutic approach.

16.
Vision (Basel) ; 6(3)2022 Jun 24.
Article in English | MEDLINE | ID: mdl-35893755

ABSTRACT

Background: To investigate macular microvascular changes after uncomplicated phacoemulsification surgery according to the cataract severity grade. Methods: Retrospective, cross-sectional study involving 23 eyes of 23 patients who underwent elective cataract extraction. All patients underwent routine ophthalmologic examination, including optical coherence tomography angiography (OCTA) at baseline (preoperative visit, T0) and seven days postoperatively (T7). OCTA scans were obtained with the spectral domain system Cirrus 5000 (Carl Zeiss Meditec, Inc., Dublin, CA, USA), and 3 mm × 3 mm raster fovea-centered scans were obtained to evaluate the superficial capillary plexus (SCP) vessel density, perfusion density, and foveal avascular zone (FAZ) parameters. Results: SCP perfusion density significantly increased from 28.3 ± 5.73% to 33.74 ± 4.13% after the surgery (p < 0.001). Similarly, SCP vessel density significantly increased from 15.14 ± 3.41 mm−1 to 18.14 ± 2.57 mm−1 after surgery (p < 0.001). The mean preoperative FAZ area significantly increased from 0.27 ± 0.12 mm to 0.24 ± 0.11 mm seven days postoperatively (p = 0.008). When comparing softer and harder cataracts, no significant variations in SCP vessel density, as well as SCP perfusion density parameters and the FAZ area, perimeter, and circularity index, were noted before and after surgery. Conclusions: Macular SPC vessel density and macular SCP perfusion density increase after uncomplicated cataract surgery regardless of the cataract severity.

17.
Ophthalmic Surg Lasers Imaging Retina ; 53(7): 368-373, 2022 07.
Article in English | MEDLINE | ID: mdl-35858228

ABSTRACT

BACKGROUND AND OBJECTIVE: Retromode scanning laser ophthalmoscopy (RM-SLO) is a new imaging modality displaying pseudo-3D retinal images. We assessed the correlation between the morphological features of full-thickness macular holes (FTMHs) when using spectral domain-optical coherence tomography (SD-OCT) and when using RM-SLO. MATERIALS AND METHODS: This is a prospective observational case series in which patients were examined through SD-OCT and RM-SLO after informed consent was obtained. Intraclass correlation coefficient (ICC) and Pearson correlation coefficient (PCC) were used to assess interobserver agreement and the correlation between the diameters measured with the two techniques. RESULTS: We enrolled 20 patients (20 eyes) with an average hole aperture size of 426 µm (140-890 µm) on SD-OCT and 56 pixels (19-102 pixels) on RM-SLO. ICC and PCC were 0.999 and 0.992, respectively. "Standard" and "double-ring" FTMH patterns were described on RM-SLO and related well with SD-OCT findings. CONCLUSIONS: RM-SLO is a reliable method for FTMH-diameter evaluation and identifies unique pseudo-3D morphological features consistent with their B-scan counterparts. [Ophthalmic Surg Lasers Imaging Retina 2022; 53:368-373.].


Subject(s)
Retinal Perforations , Humans , Lasers , Ophthalmoscopy/methods , Retina , Retinal Perforations/diagnosis , Tomography, Optical Coherence/methods
18.
Arch Bone Jt Surg ; 10(5): 439-446, 2022 May.
Article in English | MEDLINE | ID: mdl-35755787

ABSTRACT

Background: Megaprostheses are one of the preferred choices of reconstruction after tumor resection. Periprosthetic joint infections are one of the most serious complications of joint prostheses surgeries. In this study, our aim was to analyze the efficacy of silver-coated megaprostheses in reducing the risk of prosthesis-related infection. Methods: One hundred forty-two patients who had undergone implantation of a mega-endoprosthesis for non-neoplastic or post-neoplastic conditions were included in this retrospective study. The end-point of the survival analysis was the prosthesis failure due to infection. Results: Thirty-eight patients had undergone implantation of a silver-coated megaprosthesis and 104 patients a megaprosthesis without silver coating. The survival analysis showed an overall infection-free survival rate of 82.3% at five years and 61.9% at 10 years. Silver-coated prostheses had an HR of 0.72 (95% CI: 0.26-2.05; P=0.54). Conclusion: Implantation of a silver-coated mega-prosthesis in non-oncological patients did not significantly reduce the risk of prosthesis-related infection.

19.
Diagnostics (Basel) ; 12(5)2022 May 17.
Article in English | MEDLINE | ID: mdl-35626405

ABSTRACT

Background: The purpose of this study is to compare the morphology of six-month follow-up blebs created by a subconjunctival glaucoma surgical device (XEN45) to those created by a PreserFlo MicroShunt with a sub-Tenon insertion, utilizing AS-OCT. Methods: A retrospective study of 29 eyes who underwent XEN45 implantation and 29 eyes who underwent PreserFlo MicroShunt implantation. The patients were analyzed at 24 h, 1 week, 1 month, 3 months and 6 months. At each visit, the maturation and morphological alterations of the blebs were observed, as well as connections with the IOP. Results: In both groups, IOP showed significant reduction at all follow ups (p < 0.0001). In XEN group, the most common bleb morphology in the immediate postoperative was the subconjuntival separation type (42%) followed by the uniform type (34%), with a trend inversion at 6 month follow up (51% of uniform type). On the contrary, the most common morphology after PreserFlo was the multiple internal layer (55%), which showed a tendency to reduce over time and was substituted by the microcystic multiform, whose percentage increased over time (17% at day 1 vs. 44% at month 6). Uniform appearance was associated by the posterior episcleral fluid (PEF) lake presence. Both horizontal and vertical diameters significantly increased over time. Conclusion: XEN and PreserFlo implantation resulted in the production of diffuse blebs with different characteristics, which may influence IOP lowering capacity and bleb revisions necessity over time.

20.
Vision (Basel) ; 6(2)2022 Apr 02.
Article in English | MEDLINE | ID: mdl-35466272

ABSTRACT

Myopia is becoming more common across the world, affecting approximately two billion people and rising. Different kinds of therapies (optical, pharmaceutical, environmental, or behavioral) have been proposed to decrease myopia progression, but with variable results and a lack of standardization. The evidence that targeted myopic defocus inhibits eye length growth has paved the way for several contact and spectacle lense designs to induce a peripheral defocus, thus slowing myopia progression, but the perfect configuration has yet to be defined. One of the newest and more promising approaches in this field is the use of Defocus Incorporated Multiple Segments (DIMS) lenses. These lenses are built from the assumption that targeted myopic defocus, produced by 396 mid-peripheral lenslets with positive power, inhibits eye length growth. Recent studies have highlighted the effectiveness of these lenses compared to children who had worn single vision spectacle lenses, in terms of myopia control and tolerability. Despite the evidence that these lenses can help slow down the progression of myopia, the occasional mid-peripheral aberrations they can induce, as well as the overall eye strain that comes with wearing them, should not be overlooked. The aim of this review is to give attention to the advantages and the shortfalls of this new approach and to evaluate its effectiveness in clinical practice.

SELECTION OF CITATIONS
SEARCH DETAIL
...