1.
Cells ; 11(7)2022 03 25.
Article in English | MEDLINE | ID: mdl-35406671

ABSTRACT

Accumulation of senescent chondrocytes is thought to drive inflammatory processes and subsequent cartilage degeneration in age-related as well as posttraumatic osteoarthritis (OA). However, the underlying mechanisms of senescence and consequences on cartilage homeostasis are not completely understood so far. Therefore, suitable in vitro models are needed to study chondrocyte senescence. In this study, we established and evaluated a doxorubicin (Doxo)-based model of stress-induced premature senescence (SIPS) in human articular chondrocytes (hAC). Cellular senescence was determined by the investigation of various senescence associated (SA) hallmarks including ß-galactosidase activity, expression of p16, p21, and SA secretory phenotype (SASP) markers (IL-6, IL-8, MMP-13), the presence of urokinase-type plasminogen activator receptor (uPAR), and cell cycle arrest. After seven days, Doxo-treated hAC displayed a SIPS-like phenotype, characterized by excessive secretion of SASP factors, enhanced uPAR-positivity, decreased proliferation rate, and increased ß-galactosidase activity. This phenotype was proven to be stable seven days after the removal of Doxo. Moreover, Doxo-treated hAC exhibited increased granularity and flattened or fibroblast-like morphology. Further analysis implies that Doxo-mediated SIPS was driven by oxidative stress as demonstrated by increased ROS levels and NO release. Overall, we provide novel insights into chondrocyte senescence and present a suitable in vitro model for further studies.


Subject(s)
Chondrocytes , Osteoarthritis , Cellular Senescence/genetics , Chondrocytes/metabolism , Doxorubicin/pharmacology , Humans , Osteoarthritis/metabolism , beta-Galactosidase/metabolism
2.
J Diabetes Sci Technol ; 13(3): 507-513, 2019 05.
Article in English | MEDLINE | ID: mdl-30974985

ABSTRACT

BACKGROUND: In recent randomized clinical trials, an unusual reporting pattern of glycemic data and hypoglycemic events potentially related to an internet enabled blood glucose meter (MyGlucoHealth, BGM) was observed. Therefore, this clinical study was conducted to evaluate the system accuracy of the BGM in accordance with the ISO15197:2015 guidelines with additional data collection. METHODS: To investigate system accuracy, 10 of 3088 devices and 6 of 23 strip lots, used in the trials, were selected by a randomization procedure and a standard repeatability assessment. YSI 2300 STAT Plus was used as the standard reference method. The samples were distributed as per the ISO15197:2015 recommendations with 20 additional samples in the hypoglycemic range. Each sample was tested with 6 devices and 6 strip lots with double determinations. RESULTS: Overall, 121 subjects with blood glucose values 26-423 mg/dL were analyzed, resulting in 1452 data points. In all, 186/1452 readings (12.8%) did not meet the ISO acceptance criteria. Data evaluated according to the FDA guidelines showed that 336/1452 (23.1%) readings did not meet the acceptance criteria. A clear bias toward elevated values was observed for BG <100 mg/dL (MARD: 11.0%). CONCLUSIONS: The results show that the BGM, although approved according to standard regulatory guidelines, did not meet the level of analytical accuracy required for clinical treatment decisions according to ISO 15197:2015 and FDA requirements. In general, caution should be exercised before selection of BGMs for patients and in clinical trials.


Subject(s)
Blood Glucose/analysis , Diabetes Mellitus/blood , Hypoglycemia/diagnosis , Internet Access , Randomized Controlled Trials as Topic , Wireless Technology/instrumentation , Blood Glucose Self-Monitoring/instrumentation , Blood Glucose Self-Monitoring/standards , Clinical Trials as Topic , Data Collection/instrumentation , Data Collection/standards , Endocrinology/instrumentation , Endocrinology/methods , Endocrinology/standards , Equipment Design/standards , Equipment Failure Analysis , Female , Humans , Hypoglycemia/blood , Hypoglycemia/epidemiology , Male , Middle Aged , Practice Guidelines as Topic , Randomized Controlled Trials as Topic/standards , Randomized Controlled Trials as Topic/statistics & numerical data , Reproducibility of Results , Sensitivity and Specificity , Wireless Technology/standards
3.
J Diabetes Sci Technol ; 13(3): 514-521, 2019 05.
Article in English | MEDLINE | ID: mdl-30974988

ABSTRACT

BACKGROUND: In recent clinical trials, use of the MyGlucoHealth blood glucose meter (BGM) and electronic diary was associated with an unusual reporting pattern of glycemic data and hypoglycemic events. Therefore, the performance of representative BGMs used by the patients was investigated to assess repeatability, linearity, and hematocrit interference in accordance with regulatory guidelines. METHOD: Ten devices and 6 strip lots were selected using standard randomization and repeatability procedures. Venous heparinized blood was drawn from healthy subjects, immediately aliquoted and adjusted to 5 target blood glucose (BG) ranges for the repeatability and 11 BG concentrations for the linearity tests. For the hematocrit interference test, each sample within 5 target BG ranges was split into 5 aliquots and adjusted to hematocrit levels across the acceptance range. YSI 2300 STAT Plus was used as the laboratory reference method in all experiments. RESULTS: Measurement repeatability or precision was acceptable across the target BG ranges for all devices and strip lots with coefficient of variation (CV) between 3.4-9.7% (mean: 5.7%). Linearity was shown by a correlation coefficient of .991; however, a positive bias was seen for BG <100 mg/dL (86% measurements did not meet ISO15197:2015 acceptance criteria). Significant hematocrit interference (up to 20%) was observed for BG >100 mg/dL (ISO15197:2015 acceptance criteria: ±10%), while the results were acceptable for BG <100 mg/dL. CONCLUSIONS: The BGM met repeatability requirements but demonstrated a significant measurement bias in the low BG range. In addition, it failed the ISO15197:2015 criteria for hematocrit interference.


Subject(s)
Blood Glucose/analysis , Clinical Laboratory Techniques , Diabetes Mellitus/blood , Equipment and Supplies/standards , Internet Access , Artifacts , Blood Glucose Self-Monitoring/instrumentation , Blood Glucose Self-Monitoring/standards , Clinical Laboratory Techniques/methods , Equipment Design , Equipment Failure Analysis , Hematocrit/instrumentation , Hematocrit/methods , Hematocrit/standards , Humans , Linear Models , Reagent Strips/standards , Reproducibility of Results