Biosens Bioelectron ; 103: 138-142, 2018 Apr 30.
Article in English | MEDLINE | ID: mdl-29291593

ABSTRACT

Enzyme-linked immunosorbent assay (ELISA) is one of the most important technologies for biochemical analysis critical for diagnosis and monitoring of many diseases. Traditional systems for ELISA incubation and reading are expensive and bulky, thus cannot be used at point-of-care or in the field. Here, we propose and demonstrate a new miniature mobile phone based system for ELISA (MELISA). This system can be used to complete all steps of the assay, including incubation and reading. It weighs just 1 pound, can be fabricated at low cost, portable, and can transfer test results via mobile phone. We successfully demonstrated how MELISA can be calibrated for accurate measurements of progesterone and demonstrated successful measurements with the calibrated system.


Subject(s)
Biosensing Techniques/methods , Cell Phone , Enzyme-Linked Immunosorbent Assay/methods , Humans , Point-of-Care Systems
2.
Appl Opt ; 56(11): E72-E76, 2017 Apr 10.
Article in English | MEDLINE | ID: mdl-28414344

ABSTRACT

As part of the Deepwater Horizon toxicity testing program, a number of laboratories generated oil slicks in the laboratory to study potential toxic effects of these oil slicks on aquatic organisms. Understanding the details of how these slicks affect aquatic organisms requires careful correlation between slick thickness and the observed detrimental effects. Estimating oil film thickness on water can be challenging since the traditional color-based technique used in the field is very imprecise. Also, as we demonstrate here, the films formed on the water surface are highly nonuniform on a microscale level, and thus uniform thin film thickness measurement techniques based on optical interference do not work. In this paper, we present a method that estimates the local thickness of weathered oil slicks formed on artificial seawater using light transmission and Beer-Lambert's law. Here, we demonstrate results of careful calibration together with the actual thickness estimation. Due to the heterogeneity of the slicks formed, we present slick thickness as a range of thicknesses collected from multiple points within the oil slick. In all the experiments we used oil samples provided by the Natural Resource Damage Assessment toxicity testing program for the Deepwater Horizon oil spill. Therefore, this study has an important practical value and successfully addresses unique challenges related to measurements involving complex, viscous, paste-like heterogeneous substances such as weathered crude oil.

3.
Biosens Bioelectron ; 88: 204-209, 2017 Feb 15.
Article in English | MEDLINE | ID: mdl-27567707

ABSTRACT

Preeclampsia and HELLP (hemolysis, elevated liver enzymes, and low platelet count) syndrome are pregnancy-related complications with high rates of morbidity and mortality. HELLP syndrome, in particular, can be difficult to diagnose. Recent work suggests that elevated levels of free cell hemoglobin in blood plasma can, as early as the first trimester, potentially serve as a diagnostic biomarker for impending complications. We therefore developed a point-of-care mobile phone-based platform that can quickly characterize a patient's level of hemolysis by measuring the color of blood plasma. The custom hardware and software are designed to be easy to use. A sample of the whole blood (~10µL or less) is first collected into a clear capillary tube or microtube, which is then inserted into a low-cost 3D-printed sample holder attached to the phone. A 5-10min period of quiescence allows for gravitational sedimentation of the red blood cells, leaving a layer of yellowish plasma at the top of the tube. The phone camera then photographs the capillary tube and analyzes the color components of the cell-free plasma layer. The software converts these color values to a concentration of free hemoglobin, based on a built-in calibration curve, and reports the patient's hemolysis level: non-hemolyzed, slightly hemolyzed, mildly hemolyzed, frankly hemolyzed, or grossly hemolyzed.. The accuracy of the method is ~1mgdL-1. This phone-based point-of-care system provides the potentially life-saving advantage of a turnaround time of about 10min (versus 4+hours for conventional laboratory analytical methods) and a cost of approximately one dollar USD (assuming you have the phone and the software are already available).


Subject(s)
Biosensing Techniques/instrumentation , Cell Phone/instrumentation , HELLP Syndrome/diagnosis , Hemolysis , Pre-Eclampsia/diagnosis , Equipment Design , Female , Hematologic Tests/instrumentation , Humans , Point-of-Care Systems , Pregnancy , Sensitivity and Specificity