Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 54
Filter
1.
J Clin Med ; 12(14)2023 Jul 24.
Article in English | MEDLINE | ID: mdl-37510966

ABSTRACT

BACKGROUND: Catheter ablation (CA) has become safe and efficient for the treatment of patients with ventricular extrasystolic beats (VEBs). The three-dimensional electroanatomic mapping (EAM) system allows the elimination of fluoroscopy time during CA procedures. Non-fluoroscopy CA is a challenging procedure requiring intimate knowledge of cardiac anatomy in patients with VEBs. The study aimed to evaluate the efficacy and safety of the non-fluoroscopy CA using the EAM system in patients with VEBs. METHODS: Completely fluoroless CA of VEBs guided by EAM was performed in 86% (94 out of 109) of consecutive patients with VEBs. The remaining 15 patients underwent conventional fluoroscopy-guided CA. Demographic and clinical baseline characteristics, procedure parameters, and following complications were obtained from the medical records. Primary outcomes were the acute procedural success rate, the permanent success rate (6-month follow-up), complications, and procedure time. RESULTS: There were no significant differences between groups regarding baseline characteristics. Acute procedural success was achieved in 85 patients (90%) in the non-fluoroscopy group and in 14 patients (93%) in the fluoroscopy group (ns). A long-term success rate was achieved in 82 patients (87%) in the non-fluoroscopy group and in 14 (82%) patients in the fluoroscopy group (ns). The median procedure time was 85 min in the non-fluoroscopy group and 120 min in the fluoroscopy group (p = 0.029). There was only one major complication in the non-fluoroscopy group (ns). CONCLUSIONS: Completely fluoroless CA of VEBs guided by EAM is a feasible, safe, and efficient procedure.

2.
J Clin Med ; 11(7)2022 Mar 25.
Article in English | MEDLINE | ID: mdl-35407422

ABSTRACT

BACKGROUND: Catheter ablation (CA) is a safe and efficient treatment in patients with an atrioventricular accessory pathway (AP). Electroanatomical mapping (EAM) systems are useful during CA of AP, especially for reducing fluoroscopy. There are limited data about the feasibility of CA procedures performed with the use of the EAM system entirely without fluoroscopy in adults with AP. The aim of the study is to assess the feasibility, efficacy and safety of CA with the use of EAM without fluoroscopy, compared to CA with EAM and fluoroscopy in patients with AP. METHODS: The study included 83 consecutive patients (age 38.25 ± 15.8 years), who were subjected to CA for AP. In 40 patients CA was performed with the use of EAM without fluoroscopy (EAM group), and in 43 patients CA was performed with EAM and fluoroscopy (control group). Baseline characteristics, procedure parameters and complications were obtained from the medical records. Data on permanent success rate was obtained after the mean follow-up time of 1 year. Primary outcomes were acute procedural success rate, long term success rate at 1-year follow-up and complications. Secondary outcomes were the procedure time and number of applications. RESULTS: There were no statistically significant differences in baseline characteristics between the groups, except for the AP locations. Right-sided AP was more common in the EAM group, while left-sided AP was more common in the control group (p = 0.007 and p = 0.004, respectively). Acute procedural success was achieved in 38 patients (95.0%) in the EAM group and in 39 patients (90.7%) in the control group (p = 0.449). Long term success rate was achieved in 36 patients (90.0%) in the EAM group and in 36 (83.7%) patients in the control group (p = 0.399). There was one minor complication in the form of RBBB in the EAM group (p = 0.138). The mean procedure time was shorter in the EAM group compared to the control group (93.0 ± 58.3 min vs. 127.6 ± 57.5 min; p = 0.009). CONCLUSIONS: CA of both right-sided and left-sided AP completely guided by EAM without the use of fluoroscopy is feasible, safe and effective.

3.
J Clin Med ; 11(8)2022 Apr 12.
Article in English | MEDLINE | ID: mdl-35456252

ABSTRACT

Background: Increased resting heart rate (RHR) after pulmonary vein isolation (PVI) for treatment of atrial fibrillation (AF) is a common observation, possibly resulting from ganglionated plexus modification during ablation. Previous trials have suggested that an increase in RHR after ablation might be related to higher efficacy of the procedure. The aim of this study was to determine whether or not higher increase in RHR after radiofrequency (RF) PVI might predict better long-term outcome of the procedure in a real-life cohort of patients in whom index ablation for paroxysmal AF was performed. Material and methods: The health records of patients who underwent index point-by-point or drag lesion RF PVI for paroxysmal AF in our department between January 2014 and November 2018 were analyzed. Resting heart rate (RHR) was determined from 12-lead ECG recorded prior to the ablation and before discharge to evaluate changes in RHR after PVI. Only patients in sinus rhythm before the procedure and at discharge were included in the analysis. Telephone follow-up was collected for evaluation of arrhythmia recurrence status. Results: A total of 146 patients who underwent PVI for paroxysmal AF were included. Mean follow-up time was 3.5 years. RHR increased from 64 [58.5−70], prior to procedure, to 72 [64.25−80] bpm at discharge (p < 0.001). Higher increase in RHR was not protective from arrhythmia recurrence in long-term observation in both univariable HR = 1.001 (CI 0.99−1.017, p = 0.857) and multivariable analyses HR = 1.001 (CI 0.99−1.02, p = 0.84). Conclusions: RHR after PVI increased in comparison to baseline in our cohort. However, we did not observe higher increase in RHR to be associated with more favorable long-term effectiveness of the procedure.

4.
J Clin Med ; 11(3)2022 Jan 25.
Article in English | MEDLINE | ID: mdl-35160043

ABSTRACT

BACKGROUND: Adequate contact between the catheter tip and tissue is important for optimal lesion formation and, in some procedures, it has been associated with improved effectiveness and safety. We evaluated the potential benefits of contact force-sensing (CFS) catheters during non-fluoroscopic radiofrequency catheter ablation (NF-RFCA) of idiopathic ventricular arrhythmias (VAs) originating from outflow tracts (OTs). METHODS: A group of 102 patients who underwent NF-RFCA (CARTO, Biosense Webster Inc., Irvine, CA, USA) of VAs from OTs between 2014 to 2018 was retrospectively analyzed. RESULTS: We included 52 (50.9%) patients in whom NF-RFCA was performed using CFS catheters and 50 (49.1%) who were ablated using standard catheters. Arrhythmias were localized in the right and left OT in 70 (68.6%) and 32 (31.4%) patients, respectively. The RFCA acute success rate was 96.1% (n = 98) and long-term success during a minimum 12-month follow-up (mean 51.3 ± 21.6 months) was 85.3% (n = 87), with no difference between CFS and standard catheters. There was no difference in complications rate between CFS (n = 1) and standard catheter (n = 2) ablations. CONCLUSIONS: There is no additional advantage of CFS catheters use over standard catheters during NF-RFCA of OT-VAs in terms of procedural effectiveness and safety.

5.
Front Physiol ; 13: 1087837, 2022.
Article in English | MEDLINE | ID: mdl-36699671

ABSTRACT

Introduction: Heart Rate Asymmetry (HRA) describes a phenomenon of differences between accelerations and decelerations in human heart rate. Methods used for HRA assessment can be further implemented in the evaluation of asymmetry in blood pressure variations (Blood Pressure Asymmetry-BPA). Methods: We have analyzed retrospectively the series of heartbeat intervals extracted from ECG and beat-to-beat blood pressure signals from 16 vasovagal patients (age: 32.1 ± 13.3; BMI: 21.6 ± 3.8; all female) and 19 healthy subjects (age: 34.6 ± 7.6; BMI: 22.1 ± 3.4; all female) who have undergone tilt test (70°). Asymmetry was evaluated with Poincaré plot-based methods for 5 min recordings from supine and tilt stages of the test. The analyzed biosignals were heart rate (RR), diastolic (dBP) and systolic Blood Pressure (sBP) and Pulse Pressure (PP). In the paper we explored the differences between healthy and vasovagal women. Results: The changes of HRA indicators between supine and tilt were observed only in the control group (Porta Index p = 0.026 and Guzik Index p = 0.005). No significant differences in beat-to-beat variability (i.e. spread of points across the line of identity in Poincaré plot-SD1) of dBP was noted between supine and tilt in the vasovagal group (p = 0.433 in comparison to p = 0.014 in healthy females). Moreover, in vasovagal patients the PP was significantly different (supine: 41.47; tilt: 39.27 mmHg) comparing to healthy subjects (supine: 35.87; tilt: 33.50 mmHg) in supine (p = 0.019) and in tilt (p = 0.014). Discussion: Analysis of HRA and BPA represents a promising method for the evaluation of cardiovascular response to orthostatic stressors, however currently it is difficult to determine a subject's underlying health condition based only on these parameters.

6.
Europace ; 22(6): 888-896, 2020 06 01.
Article in English | MEDLINE | ID: mdl-32219388

ABSTRACT

AIMS: The GOLD AF Registry has been designed to prospectively assess the population, indications, and outcomes using second-generation phased radiofrequency (RF) ablation (pulmonary vein ablation catheter GOLD) in a global examination of standard-of-care use for the treatment of paroxysmal and persistent atrial fibrillation (AF). METHODS AND RESULTS: GOLD AF (NCT02433613) is a prospective, observational, multi-centre registry designed to characterize efficacy and safety of phased RF ablation in patients with AF. The primary endpoint was freedom from AF recurrence at 12-month follow-up after a 90-day blanking period. Ancillary objectives include safety, procedural efficiency, and quality of life (QoL). The QoL assessment using the Atrial Fibrillation Effect on QualiTy-of-Life (AFEQT) and the European Heart Rhythm Association (EHRA) Score of AF-related symptoms was collected at baseline and 12 months. In total, 1054 patients were included in this analysis (age 60.6, 67.6% male, 26.5% PersAF). Kaplan-Meier estimate of freedom from AF recurrence was 77.7% at 12 months. Peri-procedural device or procedure-related complications were observed in 26 (2.5%) patients, with a low stroke rate of 0.3%. One-year post-ablation, the EHRA AF Symptom score decreased in 68% of patients. The AFEQT score improvement was observed in 88.4% and 90.4% of patients who completed the questionnaire in-person or interviewed by phone at 12 month follow-up, respectively. CONCLUSION: Phased RF ablation for the treatment of paroxysmal and persistent AF demonstrated a 77.7% freedom from AF recurrence at 12 months in addition to a significant reduction in arrhythmia symptoms and clinically meaningful improved QoL. Low peri-procedural complication rate of <3% was reported.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Catheter Ablation/adverse effects , Catheters , Female , Humans , Male , Middle Aged , Prospective Studies , Pulmonary Veins/surgery , Quality of Life , Recurrence , Registries , Treatment Outcome
7.
Postepy Kardiol Interwencyjnej ; 16(3): 321-329, 2020 Sep.
Article in English | MEDLINE | ID: mdl-33597998

ABSTRACT

INTRODUCTION: Radiofrequency catheter ablation (RFCA) is an important method of treatment of ventricular arrhythmias (VAs). In the majority of RFCA, fluoroscopy is used, exposing patients and medical staff to all related side effects. Current experience of non-fluoroscopic (NF)-RFCA in VAs from the left side is limited. AIM: Analysis of safety and effectiveness of NF-RFCA of VAs from left- and right-sided cardiac chambers. MATERIAL AND METHODS: From 2014 to 2018, a group of 128 patients who underwent RFCA of VAs were retrospectively divided into two groups: NF-RFCA and fluoroscopic (F)-RFCA. Patients in each group were then subsequently subdivided into two groups based on VAs localization - left- (LS-Va) and right-sided (RS-Va) VAs. In all patients the CARTO Biosense Webster mapping system was used. RESULTS: In group 1 (NF-RFCA n = 88) 66 (75%) patients underwent RFCA of RS-Va and 22 (25%) of LS-Va. Early success was achieved in 89.8% (n = 79) and long term success in 81.8% (n = 72). In group 2 (F-RFCA n = 40) 19 patients (47.5%) had RFCA of RS-Va and 21 (52.5%) patients of LS-Va. Acute procedural success rate was 80% (n = 32) and long-term success 72.5% (n = 29). There were 4 (4.6%) perioperative complications in NF-RFCA and 2 (5%) in F-RFCA. Success rate, procedure time and complications were not significantly different between groups and subgroups in follow-up. CONCLUSIONS: NF-RFCA in VAs from the right and left cardiac chamber is safe and equally effective as F-RFCA, and it should be implemented as often as possible for protection of patients and electrophysiology staff.

8.
Ann Noninvasive Electrocardiol ; 25(4): e12733, 2020 07.
Article in English | MEDLINE | ID: mdl-31863721

ABSTRACT

BACKGROUND: Due to limited data, implantable loop recorders (ILR) are not currently recommended by the guidelines to routinely monitor patients after atrial fibrillation (AF) ablation. AIMS: To validate the diagnostic value of ILR after AF ablation, modern generation ILRs (LINQ) were implanted in patients scheduled for cryoballoon ablation of AF (CBA). METHODS: We included 29 patients with frequent and symptomatic episodes of paroxysmal AF. ILR was implanted 3 months prior to CBA, and data were collected before and for 6 months after the procedure. The device was programmed to maximize sensitivity of AF/ atrial tachycardia (AT) detection. All EGM recordings were "manually" assessed and annotated as true AF, pseudo AF, unrecognized AF, and episodes with no EGM available. Duration and episode-based standard performance metrics were evaluated. RESULTS: A total number of 5,842 episodes were recorded. A total of 4,403 episodes were true AF, 453 episodes were pseudo AF, and 986 episodes had no EGM available. The device did not recognize 144 episodes of AF. Duration-based sensitivity was 95.2%, duration-based specificity 99.9%, duration-based PPV 99.2%, duration-based NPV 99.9%, episode-based sensitivity 98.0%, and episode-based PPV 91.0%. Misdiagnosis happened in 1 in 10 episodes. Total data review time was 166 hr. CONCLUSIONS: Implantable loop recorders is a valuable tool in evaluation of AF episodes in patients undergoing CBA. However, for high precision all recorded episodes need to be evaluated "manually." The memory storage space is too low for frequent AF episodes, resulting in overwriting of stored EGMs and data loss.


Subject(s)
Atrial Fibrillation/physiopathology , Atrial Fibrillation/surgery , Catheter Ablation/methods , Electrocardiography, Ambulatory/instrumentation , Electrocardiography, Ambulatory/methods , Postoperative Complications/diagnosis , Adult , Aged , Female , Humans , Male , Middle Aged , Postoperative Complications/physiopathology , Prostheses and Implants , Reproducibility of Results , Sensitivity and Specificity
9.
Arch Med Sci ; 15(1): 78-85, 2019 Jan.
Article in English | MEDLINE | ID: mdl-30697256

ABSTRACT

INTRODUCTION: Our aim was to compare in a prospective randomized study the safety, direct results and periprocedural data of ablation using an nMARQ catheter, a PVAC catheter used with the EnSite system, or a PVAC catheter only under fluoroscopy control. MATERIAL AND METHODS: One hundred two patients (70 male, 57 ±11 years) with atrial fibrillation (AF) were prospectively randomized to: group 1 - ablation performed with an nMARQ catheter and the CARTO 3 system; group 2 - a PVAC catheter used with the EnSite system; group 3 - ablation with a PVAC catheter without a 3D system. RESULTS: Complete isolation of 400/402 pulmonary veins (PV) (99.5%). Linear ablation was performed in 23 patients in group 1 (small distance between lines isolating PV), in 3 patients in group 2, in 1 patient in group 3. The superior vena cava was isolated in 1 patient, 9 patients, and 9 patients respectively. Duration of fluoroscopy and dose area product were significantly smaller in group 1 (6.5 ±2.9 min/808.8 ±393.9 cGy/cm2 vs. 13.6 ±5.6 min/1662.6 ±677.8 cGy/cm2 and 18.8 ±7.6 min/2327.9 ±975.5 cGy/cm2; p < 0.001). Procedure duration was shorter in group 1 (82.9 ±18.8 min vs. 101.2 ±19.6 min, p < 0.001 and 99.8 ±20.8 min, NS). Contrast injection was necessary in 2 patients in group 1, in 8 patients in group 2 and in all patients in group 3. Because nMARQ is a thermocool catheter, the volume of fluid injection was significantly greater (2348.5 ±543.5 ml vs. 1077.9 ±280.5 ml and 1076.5 ±375.6 ml, p < 0.001). There were no periprocedural deaths. We observed no cardiac tamponade, neurological complications and no atrioesophageal fistula during follow-up. CONCLUSIONS: The lowest radiological exposure was observed during ablation performed with an nMARQ catheter. 3D systems reduced fluoroscopy duration and the necessity of contrast injection. The nMARQ catheter requires injection of a large volume of fluid.

10.
Adv Clin Exp Med ; 28(4): 461-467, 2019 Apr.
Article in English | MEDLINE | ID: mdl-30088700

ABSTRACT

BACKGROUND: Atrial fibrillation (AF) is a common clinical problem. The left atrium anatomy makes up a factor that may significantly affect the effectiveness of the AF ablation. OBJECTIVES: The aim of the study was to evaluate a long-term effectiveness ablation in patients with common pulmonary vein trunk (CPVT) and AF. MATERIAL AND METHODS: The outcomes of 129 procedures in 95 patients with CPVT out of 1,475 procedures carried out in 1,150 patients with AF treated with ablation, were analyzed. Ablation with CARTO 3 system (Johnson & Johnson, New Brunswick, USA), cryoballoon, and the circular multipolar duty-cycled radiofrequency-based pulmonary vein ablation producer with catheter (PVAC) were considered as advanced methods. The following data was recorded for every patient: age, gender, AF duration and type, previous antiarrhythmic drugs, weight, height, any prior cardioversion, and comorbidities, including hypertension, diabetes, hypothyreosis, thyrotoxicosis, heart failure, and stroke/transient ischemic attack. The following anatomical factors were assessed: the presence of patent foramen ovale (PFO) and localization of the CPVT on the basis of venography or computed tomography (CT). In the 1st year after ablation, 24-h Holter monitoring was performed 3-5 times, and the patients were encouraged to visit their doctor or an emergency department if a cardiac arrhythmia occurred. Long-term ablation effectiveness was assessed based on a telephone interview and patients' answers to the questionnaires including 12-lead electrocardiography (ECG). RESULTS: Sinus rhythm was maintained in 44 patients (43.6 %) after a median of 42 months (range 12-120). A lower number of clinical factors (odds ratio [OR] range 0.09; 95% confidence interval [CI] 0.02-0.56; p < 0.01), and advanced ablation methods (OR 3.1; 95% CI 1.4-7.1; p < 0.01) were related to a better longterm effectiveness. CONCLUSIONS: The long-term effectiveness of pulmonary vein (PV) isolation in patients with AF and CPVT is higher when advanced ablation techniques are used. Accumulation of clinical factors was found to be the most tremendous predictor of AF recurrence.


Subject(s)
Atrial Fibrillation/surgery , Catheter Ablation/methods , Pulmonary Veins/surgery , Electrocardiography, Ambulatory , Humans , Pulmonary Veins/physiopathology , Recurrence , Treatment Outcome
11.
Entropy (Basel) ; 21(4)2019 Mar 29.
Article in English | MEDLINE | ID: mdl-33267061

ABSTRACT

The paper presents an application of Transfer Entropy (TE) to the analysis of information transfer between biosignals (heart rate expressed as R-R intervals (RRI), blood pressure (sBP, dBP) and stroke volume (SV)) measured during head up tilt testing (HUTT) in patients with suspected vasovagal syndrome. The study group comprised of 80 patients who were divided into two groups: the HUTT(+) group consisting of 57 patients who developed syncope during the passive phase of the test and HUTT(-) group consisting of 23 patients who had a negative result of the passive phase and experienced syncope after provocation with nitroglycerin. In both groups the information transfer depends on the phase of the tilt test. In supine position the highest transfer occurred between driver RRI and other components. In upright position it is the driver sBP that plays the crucial role. The pre-syncope phase features the highest information transfer from driver SV to blood pressure components. In each group the comparisons of TE between different phases of HUT test showed significant differences for RRI and SV as drivers.

12.
Sci Rep ; 8(1): 14554, 2018 09 28.
Article in English | MEDLINE | ID: mdl-30266992

ABSTRACT

The paper presents a comparison of vasovagal syndrome occurrence in a head up tilt table test between patients with a positive result of passive tilt test and those with a positive result after pharmacological provocation. The study group consisted of 80 patients: 57 patients who experienced syncope in the passive phase of the test (43 women (aged: 35.6 ± 16.2) and 14 men (aged: 41.7 ± 15.6) and 23 patients who experienced syncope after pharmacological provocation (17 women (age: 32.3 ± 12) and 6 men (age: 43 ± 15). The main investigation was based on the assessment of monitored signals complexity: heart rate, blood pressure and stroke volume. The analysis of complexity in chosen measurement phases was performed with Sample Entropy. The investigation showed that the reactions of autonomic nervous system during tilt test and before syncope are similar for positive result of passive tilt test and positive result of tilt test with provocation. The differences in supine position occurred only in analysis based on impedance measurement (SV: p = 0.01). Significant differences were denoted for all signals just before the syncope (RRI, sBP, dBP: p = 0,00001 and SV: p = 0.01). In analysis of signals complexity the significant differences occurred just before the syncope for Sample Entropy of blood pressure (SampEn (sBP): p = 0.0008, SampEn (dBP): p = 0,0001).


Subject(s)
Syncope, Vasovagal/diagnosis , Adult , Female , Hemodynamics/drug effects , Humans , Male , Middle Aged , Nitroglycerin/pharmacology , Retrospective Studies , Syncope, Vasovagal/physiopathology , Tilt-Table Test , Vasodilator Agents/pharmacology , Young Adult
13.
Pol Arch Intern Med ; 128(3): 166-170, 2018 03 29.
Article in English | MEDLINE | ID: mdl-29600967

ABSTRACT

INTRODUCTION    Inadvertently induced ventricular fibrillation (VF) by radiofrequency (RF) energy delivery for premature ventricular complexes (PVCs) is a rare phenomenon; nevertheless, it is crucial to assess long­term risk of sudden cardiac death in these patients. OBJECTIVES    The aim of our study was to define the long­term prognosis in patients with normal ejection fraction (EF), in whom VF was inadvertently induced by RF energy application during ablation of symptomatic idiopathic PVCs originating from the right ventricular outflow tract (RVOT). PATIENTS AND METHODS    Among over 20 000 RF catheter ablations performed at 5 tertiary centers (2008-2016), 6 patients (5 men) had VF induced by RF application to the RVOT. The mean (SD) age of patients was 35.2 (16.8) years. All patients had normal EF (≥60%). We analyzed the risk of malignant ventricular arrhythmias and assessed heart function during follow­up. RESULTS    After ablation, baseline contrast­enhanced magnetic resonance imaging was performed in 4 of the 6 patients; no area of late gadolinium enhancement was observed. One patient received an implantable cardioverter­defibrillator (ICD). Exercise tests revealed only rare PVCs. All patients completedthe follow­up (mean [SD] duration of follow­up, 64.0 [34.9] months). All patients were alive, with no cases of syncope, documented ventricular tachycardia, or VF. The patient with an ICD received 2 inappropriate high­voltage therapies. CONCLUSIONS    Patients with inadvertently induced VF via RF energy application during ablation of PVCs from the RVOT, who have normal left ventricular function and no electrocardiography abnormalities have good prognosis and low VF risk during long­term follow­up. Therefore, ICD placement seems to be not indicated for these patients.


Subject(s)
Defibrillators, Implantable , Radio Waves/adverse effects , Ventricular Fibrillation/etiology , Ventricular Premature Complexes/radiotherapy , Adult , Aged , Female , Heart Ventricles/radiation effects , Humans , Male , Prognosis , Radiofrequency Therapy , Ventricular Fibrillation/diagnosis , Young Adult
14.
Entropy (Basel) ; 20(12)2018 Dec 16.
Article in English | MEDLINE | ID: mdl-33266699

ABSTRACT

The paper presents possible applications of entropy measures in analysis of biosignals recorded during head up tilt testing (HUTT) in patients with suspected vasovagal syndrome. The study group comprised 80 patients who developed syncope during HUTT (57 in the passive phase of the test (HUTT(+) group) and 23 who had negative result of passive phase and developed syncope after provocation with nitroglycerine (HUTT(-) group)). The paper focuses on assessment of monitored signals' complexity (heart rate expressed as R-R intervals (RRI), blood pressure (sBP, dBP) and stroke volume (SV)) using various types of entropy measures (Sample Entropy (SE), Fuzzy Entropy (FE), Shannon Entropy (Sh), Conditional Entropy (CE), Permutation Entropy (PE)). Assessment of the complexity of signals in supine position indicated presence of significant differences between HUTT(+) versus HUTT(-) patients only for Conditional Entropy (CE(RRI)). Values of CE(RRI) higher than 0.7 indicate likelihood of a positive result of HUTT already at the passive phase. During tilting, in the pre-syncope phase, significant differences were found for: (SE(sBP), SE(dBP), FE(RRI), FE(sBP), FE(dBP), FE(SV), Sh(sBP), Sh(SV), CE(sBP), CE(dBP)). HUTT(+) patients demonstrated significant changes in signals' complexity more frequently than HUTT(-) patients. When comparing entropy measurements done in the supine position with those during tilting, SV assessed in HUTT(+) patients was the only parameter for which all tested measures of entropy (SE(SV), FE(SV), Sh(SV), CE(SV), PE(SV)) showed significant differences.

15.
Cardiol J ; 25(3): 327-332, 2018.
Article in English | MEDLINE | ID: mdl-28612907

ABSTRACT

BACKGROUND: Development of electroanatomical systems make it possible to perform ablations without the use of fluoroscopy. The aim of this study was to evaluate the efficacy and safety of cryoablation pro-cedures without the use of fluoroscopy. METHODS: The study group consisted of 45 patients (14 female; age 36 ± 15 years) treated with cry-oablation using the EnSite electroanatomical system: 10 with ventricular extrasystoly from the right ventricle, 6 with the arrhythmogenic site near the left coronary artery, 17 patients with Wolff-Parkinson- -White syndrome (WPW), 2 patients with atrioventricular nodal reentrant tachycardia (AVNRT) type 2, 7 patients with AVNRT type 1, 3 patients with atrial tachycardia. RESULTS: In 38 of the 45 patients (84%) cryoablation procedure was performed without the use of fluoroscopy. Cryoablation efficacy was 78.9%. In 5 patients unsuccessful cryoablation was fallowed by radiofrequency applications. Finally, efficacy reached 92.1%. There were no deaths. In 1 patient a small adverse event - right bundle branch block was observed after ablation of para-Hisian accessory path-way. No other adverse events were observed. In the long term follow-up efficacy was 89.5%. CONCLUSIONS: Cryoablation using electroanatomical system without the use of fluoroscopy is a safe and efficient procedure and it is a possible alternative in most patients qualified for cryoablation.


Subject(s)
Arrhythmias, Cardiac/surgery , Body Surface Potential Mapping , Cryosurgery/methods , Imaging, Three-Dimensional , Surgery, Computer-Assisted/methods , Adult , Arrhythmias, Cardiac/diagnosis , Arrhythmias, Cardiac/physiopathology , Echocardiography , Female , Fluoroscopy , Follow-Up Studies , Humans , Male , Middle Aged , Treatment Outcome
18.
Adv Clin Exp Med ; 26(1): 109-113, 2017.
Article in English | MEDLINE | ID: mdl-28397441

ABSTRACT

BACKGROUND: Atrial fibrillation (AF) is associated with endothelial dysfunctions. OBJECTIVES: The aim of the study was to assess the influence of the duration of an AF episode on the endothelial function. MATERIAL AND METHODS: The study included 65 patients with persistent AF qualified for the percutaneous pulmonary veins isolation. Patients were divided into three subgroups with increasing time of the duration of AF episode, as follow: ≤ 7 months (n = 24 patients), from 7 to 14 months (n = 18 patients) and ≥ 14 months (n = 23 patients). Concentrations of endothelin-1 (ET-1), thrombomodulin (TM) and VEGF in serum were measured. RESULTS: Median age in the whole study group was 56 years with 84.6% of males. Patients with longer lasting AF episode had a higher body mass index and less incidence of heart failure. Median values of ET1, TM and VEGF were 3.1 (2.5-3.5) pg/mL, 3126.0 (2827.2-3594.1) pg/mL and 464.6 (323.6-630.1), respectively. Among increasing tertiles of AF episode duration, median ET-1 serum concentrations were as follows: 3.3 (2.8-3.7) pg/mL, 3.06 (2.6-3.4) pg/mL, 2.7 (2.3-3.2) pg/mL, p = 0.019, respectively. There was also a trend towards negative association of serum VEGF level with AF episode duration. Serum biomarkers' levels were not associated with total AF duration. CONCLUSIONS: AF episode duration may be associated with the endothelial function, assessed by serum biomarkers. ET-1 serum concentrations are significantly lower in patients with longer AF. ET-1, TM and VEGF have no correlation with total AF duration.


Subject(s)
Atrial Fibrillation/physiopathology , Endothelium, Vascular/physiopathology , Vascular Endothelial Growth Factor A/blood , Catheter Ablation , Endothelin-1/blood , Female , Humans , Male , Middle Aged , Pulmonary Veins , Thrombomodulin/blood
19.
Adv Clin Exp Med ; 26(1): 129-134, 2017.
Article in English | MEDLINE | ID: mdl-28397444

ABSTRACT

BACKGROUND: Cardiac arrhythmias are common in pregnant women. In most cases, they do not require treatment other than rest, electrolyte supplementation and avoidance of strong coffee and tea. Persistent arrhythmia or the ventricular rate running at a high frequency may cause hemodynamic deterioration in the fetus or in both the fetus and the mother. OBJECTIVES: The aim of this study was to assess the prevalence and characteristics of arrhythmias in pregnant women who qualified for ablation as well as the feasibility and specific features of these interventions. MATERIAL AND METHODS: The study group consisted of 11 pregnant women (16-32 Hbd) aged 31 + 6. The control group consisted of 111 women aged 15-50 years (34 + 10), scheduled for ablation in 2012. The medical records of the selected study and control groups were analyzed and the following data was retrieved: age, the reason the ablation procedure was performed, the ablation duration, the number of radiofrequency applications, the total duration of radiofrequency applications, gravity, and comorbidities. RESULTS: In the study group, accessory pathway related arrhythmias or atrial tachycardia (AT) accounted for 62% of cases, whereas in the control group for 32% (p = 0.042). All the procedures in the study group were performed with an electroanatomical system without fluoroscopy. All of the patients, but one, had no recurrence of arrhythmia. There were no complications and no overt effects were noted in the fetus. CONCLUSIONS: Ablation of arrhythmias during pregnancy is rare. An experienced surgeon using electroanatomical system is usually able to ablate arrhythmic substrate without the use of X-ray fluoroscopy. The most prevalent causes of arrhythmias in pregnant women requiring ablation are accessory pathway and AT focus.


Subject(s)
Arrhythmias, Cardiac/therapy , Catheter Ablation/methods , Pregnancy Complications/therapy , Adult , Case-Control Studies , Female , Fluoroscopy , Humans , Pregnancy , Retrospective Studies
20.
Article in English | MEDLINE | ID: mdl-28314850

ABSTRACT

BACKGROUND: The occurrence of ventricular tachyarrhythmias seems to follow circadian, daily, and seasonal distributions. Our aim is to identify potential temporal patterns of electrical storm (ES), in which a cluster of ventricular tachycardias or ventricular fibrillation, negatively affects short- and long-term survival. METHODS AND RESULTS: The TEMPEST study (Circannual Pattern and Temperature-Related Incidence of Electrical Storm) is a patient-level, pooled analysis of previously published data sets. Study selection criteria included diagnosis of ES, absence of acute coronary syndrome as the arrhythmic trigger, and ≥10 patients included. At the end of the selection and collection processes, 5 centers had the data set from their article pooled into the present registry. Temperature data and sunrise and sunset hours were retrieved from Weather Underground, the largest weather database available online. Total sample included 246 patients presenting with ES (221 men; age: 65±9 years). Each ES episode included a median of 7 ventricular tachycardia/ventricular fibrillation episodes. Fifty-nine percent of patients experienced ES during daytime hours (P<0.001). The prevalence of ES was significantly higher during workdays, with Saturdays and Sundays registering the lowest rates of ES (10.4% and 7.2%, respectively, versus 16.5% daily mean from Monday to Friday; P<0.001). ES occurrence was significantly associated with increased monthly temperature range when compared with the month before (P=0.003). CONCLUSIONS: ES incidence is not homogenous over time but seems to have a clustered pattern, with a higher incidence during daytime hours and working days. ES is associated with an increase in monthly temperature variation. CLINICAL TRIAL REGISTRATION: https://www.crd.york.ac.uk. Unique identifier: CRD42013003744.


Subject(s)
Electrocardiography , Seasons , Tachycardia, Ventricular/epidemiology , Ventricular Fibrillation/epidemiology , Aged , Anti-Arrhythmia Agents/therapeutic use , Circadian Rhythm , Cluster Analysis , Comorbidity , Databases, Factual , Defibrillators, Implantable , Female , Humans , Incidence , Male , Middle Aged , Prognosis , Risk Assessment , Sampling Studies , Severity of Illness Index , Survival Rate , Tachycardia, Ventricular/diagnosis , Tachycardia, Ventricular/therapy , Temperature , Ventricular Fibrillation/diagnosis , Ventricular Fibrillation/therapy
SELECTION OF CITATIONS
SEARCH DETAIL