Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
BMJ Open ; 12(3): e052845, 2022 03 28.
Article in English | MEDLINE | ID: mdl-35351701

ABSTRACT

INTRODUCTION: Expanded-criteria donors (ECDs) are used to reduce the shortage of kidneys for transplantation. However, kidneys from ECDs are associated with an increased risk of delayed graft function (DGF), a risk factor for allograft loss and mortality. HYPOREME will be a multicentre randomised controlled trial (RCT) comparing targeted hypothermia to normothermia in ECDs, in a country where the use of machine perfusion for organ storage is the standard of care. We hypothesise that hypothermia will decrease the incidence of DGF. METHODS AND ANALYSIS: HYPOREME is a multicentre RCT comparing the effect on kidney function in recipients of targeted hypothermia (34°C-35°C) and normothermia (36.5°C-37.5°C) in the ECDs. The temperature intervention starts from randomisation and is maintained until aortic clamping in the operating room. We aim to enrol 289 ECDs in order to analyse the kidney function of 516 recipients in the 53 participating centres. The primary outcome is the occurrence of DGF in kidney recipients, defined as a requirement for renal replacement therapy within 7 days after transplantation (not counting a single session for hyperkalemia during the first 24 hours). Secondary outcomes include the proportion of patients with individual organs transplanted in each group; the number of organs transplanted from each ECD and the vital status and kidney function of the recipients 7 days, 28 days, 3 months and 1 year after transplantation. An interim analysis is planned after the enrolment of 258 kidney recipients. ETHICS AND DISSEMINATION: The trial was approved by the ethics committee of the French Intensive Care Society (CE-SRLF-16-07) on 26 April 2016 and by the competent French authorities on 20 April 2016 (Comité de Protection des Personnes-TOURS-Région Centre-Ouest 1, registration #2016-S3). Findings will be published in peer-reviewed journals and presented during national and international scientific meetings. TRIAL REGISTRATION NUMBER: NCT03098706.


Subject(s)
Hypothermia , Kidney Transplantation , Transplants , Graft Survival , Humans , Hypothermia/etiology , Kidney , Kidney Transplantation/adverse effects , Multicenter Studies as Topic , Randomized Controlled Trials as Topic , Tissue Donors
2.
World J Crit Care Med ; 6(1): 48-55, 2017 Feb 04.
Article in English | MEDLINE | ID: mdl-28224107

ABSTRACT

AIM: To identify the risk factors for mortality in intensive care patients with postoperative peritonitis (POP). METHODS: This was a retrospective analysis using a prospective database that includes all patients hospitalized in a surgical intensive care unit for POP from September 2006 to August 2011. The data collected included demographics, comorbidities, postoperative severity parameters, bacteriological findings, adequacy of antimicrobial therapy and surgical treatments. Adequate source control was defined based on a midline laparotomy, infection source control and intraoperative peritoneal lavage. The number of reoperations needed was also recorded. RESULTS: A total of 201 patients were included. The overall mortality rate was 31%. Three independent risk factors for mortality were identified: The Simplified Acute Physiological II Score (OR = 1.03; 95%CI: 1.02-1.05, P < 0.001), postoperative medical complications (OR = 6.02; 95%CI: 1.95-18.55, P < 0.001) and the number of reoperations (OR = 2.45; 95%CI: 1.16-5.17, P = 0.015). Surgery was considered as optimal in 69% of the cases, but without any significant effect on mortality. CONCLUSION: The results from the large cohort in this study emphasize the role of the initial postoperative severity parameters in the prognosis of POP. No predefined criteria for optimal surgery were significantly associated with increased mortality, although the number of reoperations appeared as an independent risk factor of mortality.

3.
Anesth Analg ; 122(5): 1480-3, 2016 May.
Article in English | MEDLINE | ID: mdl-27101495

ABSTRACT

BACKGROUND: Pulmonary artery catheters (PACs) are frequently used for monitoring patient temperatures in the intensive care unit. Nevertheless, data regarding the accuracy of these measurements are lacking, and few data testify to the accuracy of temperatures recorded after the PAC has been in place for several days. The absolute values of such measurements are relevant for critical care because patient temperatures are often used as diagnostic criteria for sepsis and antibiotic therapy. We thus hypothesized that the Edwards Lifesciences PAC would accurately measure blood temperature. To test our hypothesis, we compared temperature measurements obtained from PACs inserted in patients for different lengths of time with measurements of a reference platinum resistance thermometer (PRT). METHODS: PACs were removed and analyzed in 39 patients in whom PACs were inserted for 0 to 5 days. The PACs were placed in calibration baths, and 10 consecutive measurements at each of 7 different temperatures were obtained (36°C, 36.5°C, 37°C, 38°C, 38.3°C, 39°C, and 40°C). The temperature measurements obtained using PACs were compared with measurements obtained using a PRT. Bland-Altman statistical analyses were performed. Outliers, defined as PAC temperature measurements that varied more than ±0.3°C from PRT measurements, were identified. We considered a catheter unfit for clinical diagnostic or therapeutic use if ≥15% of data pairs were outliers. RESULTS: A total of 2730 data pairs were analyzed. Overall, the bias was -0.15°C; the precision was +0.13°C; and the limits of agreement were -0.45°C to +0.13°C. The bias and limits of agreement did not differ according to the age of the catheter or the temperature tested. One hundred fourteen data pairs (4.2% [95% confidence interval, 2.0%-6.4%]), involving 13 PACs and mostly from 4 PACs, were outliers. CONCLUSIONS: We conclude that temperature measurements obtained using the Edwards Lifesciences PACs are thus sufficiently accurate to be used for clinical temperature monitoring in critically ill patients.


Subject(s)
Body Temperature Regulation , Catheterization, Swan-Ganz/instrumentation , Catheters, Indwelling , Monitoring, Physiologic/instrumentation , Thermodilution/instrumentation , Thermometers , Vascular Access Devices , Calibration , Catheterization, Swan-Ganz/standards , Catheters, Indwelling/standards , Critical Illness , Equipment Design , Humans , Intensive Care Units , Materials Testing , Monitoring, Physiologic/standards , Predictive Value of Tests , Reference Standards , Reproducibility of Results , Thermodilution/standards , Thermometers/standards , Time Factors , Vascular Access Devices/standards
4.
Case Rep Crit Care ; 2016: 1264283, 2016.
Article in English | MEDLINE | ID: mdl-27127661

ABSTRACT

Background. The incidence of Lemierre's syndrome has increased in the past decade. This posttonsillitis complication may be life threatening. Case Presentation. A 19-year-old patient was admitted to Surgical Intensive Care Unit of a French University Hospital for high fever, low blood pressure, and haemoptysis following a sore throat episode. Blood analysis revealed a thrombopenia, an acute renal failure, and an elevated lactate serum. Fusobacterium necrophorum was found in blood cultures. Computed tomography of the neck and lungs confirmed the diagnosis of Lemierre's syndrome: pleural effusions, bilateral lung infiltrates, and an internal jugular vein thrombosis. Fluid administration and antibiotic treatment were quickly initiated. Patient left the unit four days after his admission without any organ dysfunction. Conclusion. Lemierre's syndrome may lead to multiorgan dysfunction and should be rapidly identified.

SELECTION OF CITATIONS
SEARCH DETAIL
...