Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 25
Filter
Add more filters










Publication year range
1.
Brain Stimul ; 17(3): 668-675, 2024.
Article in English | MEDLINE | ID: mdl-38740182

ABSTRACT

BACKGROUND: Virtually everyone is exposed to power-frequency MF (50/60 Hz), inducing in our body electric fields and currents, potentially modulating brain function. MF-induced electric fields within the central nervous system can generate flickering visual perceptions (magnetophosphenes), which form the basis of international MF exposure guidelines and recommendations protecting workers and the general public. However, magnetophosphene perception thresholds were estimated 40 years ago in a small, unreplicated study with significant uncertainties and leaving open the question of the involved interaction site. METHODS: We used a stimulation modality termed transcranial alternating magnetic stimulation (tAMS), delivering in situ sinusoidal electric fields comparable to transcranial alternating current stimulation (tACS). Magnetophosphene perception was quantified in 81 volunteers exposed to MF (eye or occipital exposure) between 0 and 50 mT at frequencies of 20, 50, 60 and 100 Hz. RESULTS: Reliable magnetophosphene perception was induced with tAMS without any scalp sensation, a major advantage as compared to tACS. Frequency-dependent thresholds were quantified using binary logistic regressions hence allowing to establish condition dependent probabilities of perception. Results support an interaction between induced current density and retinal rod cells. CONCLUSION: Beyond fundamental and immediate implications for international safety guidelines, and for identifying the interaction site underlying phosphene perception (ubiquitous in tACS experiments), our results support exploring the potential of tAMS for the differential diagnosis of retinal disorders and neuromodulation therapy.


Subject(s)
Phosphenes , Transcranial Magnetic Stimulation , Visual Perception , Humans , Male , Adult , Female , Phosphenes/physiology , Transcranial Magnetic Stimulation/methods , Visual Perception/physiology , Young Adult , Sensory Thresholds/physiology , Magnetic Fields , Middle Aged
2.
Bioelectromagnetics ; 45(4): 171-183, 2024 May.
Article in English | MEDLINE | ID: mdl-38348647

ABSTRACT

In recent years, an increasing number of studies have discussed the mechanisms of vestibular activation in strong magnetic field settings such as occur in a magnetic resonance imaging scanner environment. Amid the different hypotheses, the Lorentz force explanation currently stands out as the most plausible mechanism, as evidenced by activation of the vestibulo-ocular reflex. Other hypotheses have largely been discarded. Nonetheless, both human data and computational modeling suggest that electromagnetic induction could be a valid mechanism which may coexist alongside the Lorentz force. To further investigate the induction hypothesis, we provide, herein, a first of its kind dosimetric analysis to estimate the induced electric fields at the vestibular system and compare them with what galvanic vestibular stimulation would generate. We found that electric fields strengths from induction match galvanic vestibular stimulation strengths generating vestibular responses. This review examines the evidence in support of electromagnetic induction of vestibular responses, and whether movement-induced time-varying magnetic fields should be further considered and investigated.


Subject(s)
Reflex, Vestibulo-Ocular , Vestibule, Labyrinth , Humans , Electric Stimulation/methods , Reflex, Vestibulo-Ocular/physiology , Vestibule, Labyrinth/physiology , Electromagnetic Phenomena , Magnetic Resonance Imaging
3.
Bioelectromagnetics ; 43(7): 399-403, 2022 Oct.
Article in English | MEDLINE | ID: mdl-36403265

ABSTRACT

Numerous studies have been carried out on the potential effects of an extremely low frequency (ELF-0-300 Hz) magnetic field (MF) on human health. However, there is limited data on the effect of a high exposure level to ELF MFs for a prolonged period. Therefore, the objective of this pilot work was to demonstrate the feasibility of a study evaluating the stress hormone concentrations resulting from a 10-min exposure to a 60 Hz MF of several tens of thousands of µT. In this pilot study, human volunteers were thus exposed for the first time to a 60 Hz, 50 mT MF for a duration of 10 min. Stress hormone levels were measured before (once), during (twice) and after (once) this 10-min exposure period. The small sample size (n = 5) did not allow to conduct standard inferential statistical tests and no conclusion regarding the exposure effects can be drawn. However, this study demonstrates the feasibility of using a simple blood testing material in a protocol testing for the effect of a 10-min exposure to a high MF level in healthy human volunteers. © 2022 Bioelectromagnetics Society.


Subject(s)
Hydrocortisone , Thyrotropin , Humans , Pilot Projects , Feasibility Studies , Magnetic Fields
4.
Bioelectromagnetics ; 43(6): 355-367, 2022 Sep.
Article in English | MEDLINE | ID: mdl-35801487

ABSTRACT

Electric fields from both extremely low-frequency magnetic fields (ELF-MF) and alternating current (AC) stimulations impact human neurophysiology. As the retinal photoreceptors, vestibular hair cells are graded potential cells and are sensitive to electric fields. Electrophosphene and magnetophosphene literature suggests different impacts of AC and ELF-MF on the vestibular hair cells. Furthermore, while AC modulates the vestibular system more globally, lateral ELF-MF stimulations could be more utricular specific. Therefore, to further address the impact of ELF-MF-induced electric fields on the human vestibular system and the potential differences with AC stimulations, we investigated the effects of both stimulation modalities on the perception of verticality using a subjective visual vertical (SVV) paradigm. For similar levels of SVV precision, the ELF-MF condition required more time to adjust SVV, and SVV variability was higher with ELF-MF than with AC vestibular-specific stimulations. Yet, the differences between AC and ELF-MF stimulations were small. Overall, this study highlights small differences between AC and ELF-MF vestibular stimulations, underlines a potential utricular contribution, and has implications for international exposure guidelines and standards. © 2022 Bioelectromagnetics Society.


Subject(s)
Electricity , Magnetic Fields , Electric Stimulation , Humans , Perception
5.
J Neural Eng ; 17(3): 036034, 2020 07 03.
Article in English | MEDLINE | ID: mdl-32470963

ABSTRACT

OBJECTIVE: We aimed at characterizing, in non-invasive human brain recordings, the large-scale, coordinated activation of distant brain regions thought to occur during conscious perception. This process is termed ignition in the Global Workspace Theory, and integration in Integrated Information Theory, which are two of the major theories of consciousness. APPROACH: Here, we provide evidence for this process in humans by combining a magnetically-induced phosphene perception task with electroencephalography. Functional cortical networks were identified and characterized using graph theory to quantify the impact of conscious perception on local (segregation) and distant (integration) processing. MAIN RESULTS: Conscious phosphene perception activated frequency-specific networks, each associated with a specific spatial scale of information processing. Integration increased within an alpha-band functional network, while changes in segregation occurred in the beta band. SIGNIFICANCE: These results bring novel evidence for the functional role of distinct brain oscillations and confirm the key role of integration processes for conscious perception in humans.


Subject(s)
Consciousness , Electroencephalography , Brain , Brain Mapping , Humans , Perception
6.
Bioelectromagnetics ; 40(6): 365-374, 2019 Sep.
Article in English | MEDLINE | ID: mdl-31338856

ABSTRACT

It is well known that applying transcranial alternating current stimulation (tACS) to the scalp can generate artefactual visual perceptions of flashing or shimmering light known as phosphenes. The thresholds for generating these phosphenes have been used by international standards bodies to provide conservative estimates of the field strength required to interfere with human neural functioning and set safety limits accordingly. However, the precise relationship between electric currents and phosphene perception thresholds remains uncertain. The present study used tACS to systematically investigate the effects of the location and the frequency of stimulation on phosphene perception thresholds. These thresholds were obtained from 24 participants using a within-subject design as a function of scalp stimulation sites (FPz-Cz versus Oz-Cz) and stimulation frequency (2-30 Hz in steps of 2 Hz). Phosphene perception thresholds were consistently lower for FPz-Cz stimulation, and regardless of tACS location were lowest for 16 Hz stimulation. Threshold variation between participants was very small, which is meaningful when setting standards based on phosphenes. Bioelectromagnetics. 2019;40:365-374. © 2019 Bioelectromagnetics Society.


Subject(s)
Phosphenes/physiology , Transcranial Direct Current Stimulation/methods , Adult , Electrodes , Female , Humans , Male , Photic Stimulation , Sensory Thresholds
7.
Exp Brain Res ; 237(3): 611-623, 2019 Mar.
Article in English | MEDLINE | ID: mdl-30519897

ABSTRACT

Studies have found that extremely low-frequency (ELF, < 300 Hz) magnetic fields (MF) can modulate standing balance; however, the acute balance effects of high flux densities in this frequency range have not been systematically investigated yet. This study explores acute human standing balance responses of 22 participants exposed to magnetic induction at 50 and 100 mTrms (MF), and to 1.5 mA alternating currents (AC). The center of pressure displacement (COP) was collected and analyzed to investigate postural modulation. The path length, the area, the velocity, the power spectrum in low (< 0.5 Hz) and medium (0.5-2 Hz) bands have computed and showed the expected effect of the positive control direct current (DC) electric stimulation but failed to show any significant effect of the time-varying stimulations (AC and MF). However, we showed a significant biased stabilization effect on postural data from the custom experimental apparatus employed in this work, which might have neutralized the hypothesized results.


Subject(s)
Magnetic Fields , Postural Balance/physiology , Vestibule, Labyrinth/physiology , Adult , Electric Stimulation/instrumentation , Electric Stimulation/methods , Female , Humans , Male , Young Adult
8.
Article in English | MEDLINE | ID: mdl-29186760

ABSTRACT

Humans are surrounded by sources of daily exposure to power-frequency (60 Hz in North America) magnetic fields (MFs). Such time-varying MFs induce electric fields and currents in living structures which possibly lead to biological effects. The present pilot study examined possible extremely low frequency (ELF) MF effects on human neuromotor control in general, and physiological postural tremor and electroencephalography (EEG) in particular. Since the EEG cortical mu-rhythm (8-12 Hz) from the primary motor cortex and physiological tremor are related, it was hypothesized that a 60 Hz MF exposure focused on this cortical region could acutely modulate human physiological tremor. Ten healthy volunteers (age: 23.8 ± 4 SD) were fitted with a MRI-compatible EEG cap while exposed to 11 MF conditions (60 Hz, 0 to 50 mTrms, 5 mTrms increments). Simultaneously, physiological tremor (recorded from the contralateral index finger) and EEG (from associated motor and somatosensory brain regions) were measured. Results showed no significant main effect of MF exposure conditions on any of the analyzed physiological tremor characteristics. In terms of EEG, no significant effects of the MF were observed for C1, C3, C5 and CP1 electrodes. However, a significant main effect was found for CP3 and CP5 electrodes, both suggesting a decreased mu-rhythm spectral power with increasing MF flux density. This is however not confirmed by Bonferroni corrected pairwise comparisons. Considering both EEG and tremor findings, no effect of the MF exposure on human motor control was observed. However, MF exposure had a subtle effect on the mu-rhythm amplitude in the brain region involved in tactile perception. Current findings are to be considered with caution due to the small size of this pilot work, but they provide preliminary insights to international agencies establishing guidelines regarding electromagnetic field exposure with new experimental data acquired in humans exposed to high mT-range MFs.


Subject(s)
Brain/physiopathology , Electroencephalography/radiation effects , Magnetic Fields/adverse effects , Tremor/physiopathology , Adult , Dose-Response Relationship, Radiation , Female , Humans , Magnetic Resonance Imaging , Male , Neurophysiology , North America , Pilot Projects
9.
Bioelectromagnetics ; 38(6): 425-435, 2017 Sep.
Article in English | MEDLINE | ID: mdl-28628224

ABSTRACT

We assessed the effects of power-line frequency (60 Hz in North America) magnetic fields (MF) in humans using simultaneous electroencephalography (EEG) and functional magnetic resonance imaging (fMRI). Twenty-five participants were enrolled in a pseudo-double-blind experiment involving "real" or "sham" exposure to sinusoidal 60 Hz MF exposures delivered using the gradient coil of an MRI scanner following two conditions: (i) 10 s exposures at 3 mT (10 repetitions); (ii) 2 s exposures at 7.6 mT (100 repetitions). Occipital EEG spectral power was computed in the alpha range (8-12 Hz, reportedly the most sensitive to MF exposure in the literature) with/without exposure. Brain functional activation was studied using fMRI blood oxygen level-dependent (BOLD, inversely correlated with EEG alpha power) maps. No significant effects were detected on occipital EEG alpha power during or post-exposure for any exposure condition. Consistent with EEG results, no effects were observed on fMRI BOLD maps in any brain region. Our results suggest that acute exposure (2-10 s) to 60 Hz MF from 3 to 7.6 mT (30,000 to 76,000 times higher than average public exposure levels for 60 Hz MF) does not induce detectable changes in EEG or BOLD signals. Combined with previous findings in which effects were observed on the BOLD signal after 1 h exposure to 3 mT, 60 Hz MF, this suggests that MF exposure in the low mT range (<10 mT) might require prolonged durations of exposure to induce detectable effects. Bioelectromagnetics. 38:425-435, 2017. © 2017 Wiley Periodicals, Inc.


Subject(s)
Electroencephalography/adverse effects , Environmental Exposure/analysis , Magnetic Fields/adverse effects , Magnetic Resonance Imaging/adverse effects , Adolescent , Adult , Brain/physiology , Female , Humans , Male , Stress, Physiological , Surveys and Questionnaires , Young Adult
10.
PLoS One ; 10(7): e0132024, 2015.
Article in English | MEDLINE | ID: mdl-26214312

ABSTRACT

Several aspects of the human nervous system and associated motor and cognitive processes have been reported to be modulated by extremely low-frequency (ELF, < 300 Hz) time-varying Magnetic Fields (MF). Due do their worldwide prevalence; power-line frequencies (60 Hz in North America) are of particular interest. Despite intense research efforts over the last few decades, the potential effects of 60 Hz MF still need to be elucidated, and the underlying mechanisms to be understood. In this study, we have used functional Magnetic Resonance Imaging (fMRI) to characterize potential changes in functional brain activation following human exposure to a 60 Hz MF through motor and cognitive tasks. First, pilot results acquired in a first set of subjects (N=9) were used to demonstrate the technical feasibility of using fMRI to detect subtle changes in functional brain activation with 60 Hz MF exposure at 1800 µT. Second, a full study involving a larger cohort of subjects tested brain activation during 1) a finger tapping task (N=20), and 2) a mental rotation task (N=21); before and after a one-hour, 60 Hz, 3000 µT MF exposure. The results indicate significant changes in task-induced functional brain activation as a consequence of MF exposure. However, no impact on task performance was found. These results illustrate the potential of using fMRI to identify MF-induced changes in functional brain activation, suggesting that a one-hour 60 Hz, 3000 µT MF exposure can modulate activity in specific brain regions after the end of the exposure period (i.e., residual effects). We discuss the possibility that MF exposure at 60 Hz, 3000 µT may be capable of modulating cortical excitability via a modulation of synaptic plasticity processes.


Subject(s)
Brain/physiology , Magnetic Fields , Magnetic Resonance Imaging , Adult , Brain Mapping , Cognition , Female , Humans , Male , Motor Activity , Psychomotor Performance , Time Factors , Young Adult
12.
Electromagn Biol Med ; 32(2): 137-44, 2013 Jun.
Article in English | MEDLINE | ID: mdl-23675616

ABSTRACT

Understanding the biological mechanisms by which extremely low-frequency (ELF, < 300 Hz) magnetic fields (MFs) interact with human brain activity is an active field of research. Such knowledge is required by international agencies providing guidelines for general public and workers exposure to ELF MFs (such as ICNIRP, the International Commission on Non-Ionizing Radiation Protection). The identification of these interaction mechanisms is extremely challenging, since the effects of ELF MF exposure need to be monitored and understood at very different spatial (from micrometers to centimeters) and temporal (from milliseconds to minutes) scales. One possibility to overcome these issues is to develop biophysical models, based on the systems of mathematical equations describing the electric or metabolic activity of the brain tissue. Biophysical models of the brain activity offer the possibility to simulate how the brain tissue interacts with ELF MFs, in order to gain new insights into experimental data, and to test novel hypotheses regarding interaction mechanisms. This paper presents novel hypotheses regarding the effects of power line (60 Hz in North America) MFs on human brain activity, with arguments from biophysical models. We suggest a hypothetic chain of events that could bridge MF exposure with detectable effects on human neurophysiology. We also suggest novel directions of research in order to reach a convergence of biophysical models of brain activity and corresponding experimental data to identify interaction mechanisms.


Subject(s)
Magnetic Fields , Neuronal Plasticity , Synapses/physiology , Brain/cytology , Brain/physiology , Humans , Models, Biological , Nonlinear Dynamics , Protein Transport , Receptors, Neurotransmitter/metabolism , Synapses/metabolism
13.
Article in English | MEDLINE | ID: mdl-23060781

ABSTRACT

Let's imagine the cruise control of your car locked at 120 km/h on any road in any condition (city, country, highway, sunny or rainy weather), or your car air conditioner set on maximum cold in any temperature condition (even during a snowy winter): would you find it efficient? That would probably not be the most optimal strategy for a proper and comfortable driving experience. As surprising as this may seem, this is a pretty accurate illustration of how deep brain stimulation is used today to treat Parkinson's disease motor symptoms and other neurological disorders such as essential tremor, obsessive-compulsive disorder, or epilepsy.

14.
Bioelectromagnetics ; 32(8): 620-33, 2011 Dec.
Article in English | MEDLINE | ID: mdl-21544842

ABSTRACT

Extremely low frequency (ELF, <300 Hz) magnetic fields (MF) have been reported to modulate cognitive performance in humans. However, little research exists with MF exposures comparable to the highest levels experienced in occupations like power line workers and industrial welders. This research aims to evaluate the impact of a 60 Hz, 3 mT MF on human cognitive performance. Ninety-nine participants completed the double-blind protocol, performing a selection of psychometric tests under two consecutive MF exposure conditions dictated by assignment to one of three groups (sham/sham, MF exposure/sham, or sham/MF exposure). Data were analyzed using a 3 × 2 mixed model analysis of variance. Performance between repetitions improved in 11 of 15 psychometric parameters (practice effect). A significant interaction effect on the digit span forward test (F = 5.21, P < 0.05) revealed an absence of practice effects for both exposure groups but not the control group. This memory test indicates MF-induced abolition of the improvement associated with practice. Overall, this study does not establish any clear MF effect on human cognition. It is speculated that an ELF MF may interfere with the neuropsychological processes responsible for this short-term learning effect supported by brain synaptic plasticity.


Subject(s)
Cognition/radiation effects , Electromagnetic Fields/adverse effects , Magnetic Fields/adverse effects , Occupational Exposure/adverse effects , Psychological Tests , Task Performance and Analysis , Adult , Analysis of Variance , Brain/physiology , Brain/radiation effects , Cognition/physiology , Double-Blind Method , Female , Humans , Male , Middle Aged , Reaction Time/physiology , Reaction Time/radiation effects
15.
Int Arch Occup Environ Health ; 84(3): 267-77, 2011 Mar.
Article in English | MEDLINE | ID: mdl-20496180

ABSTRACT

PURPOSE: Recent research by the authors on the effects of extremely low-frequency (ELF) magnetic field (MF) exposure on human heart rate (HR), heart rate variability (HRV), and skin blood perfusion found no cardiovascular effects of exposure to an 1,800-µT, 60-Hz MF. Research from our group using rats, however, has suggested a microcirculatory response to a 200-µT, 60-Hz MF exposure. The present pilot study investigated the effects of 1 h of exposure to a 200-µT, 60-Hz MF on the human circulation. Microcirculation (as skin blood perfusion) and HR were measured using laser Doppler flowmetry. Mean arterial pressure was monitored with a non-invasive blood pressure system. METHODS: Ten volunteers were recruited to partake in a counterbalanced, single-blinded study consisting of two testing sessions (real and sham exposure) administered on separate days. Each session included four consecutive measurement periods separated by rest, allowing assessment of cumulative and residual MF effects. RESULTS: A within-subjects analysis of variance did not reveal session by time period interactions for any of the parameters which would have been suggestive of a MF effect (p > 0.05). Perfusion, HR, and skin surface temperature decreased over the course of the experiment (p < 0.05). CONCLUSIONS: The MF used in this experiment did not affect perfusion, HR, or mean arterial pressure. Decreasing perfusion and HR trends over time were similar to our previous results and appear to be associated with a combination of inactivity (resulting in decreasing body temperatures) and reduced physiological arousal.


Subject(s)
Electromagnetic Fields/adverse effects , Fingers/radiation effects , Microcirculation/radiation effects , Skin/radiation effects , Adolescent , Adult , Female , Fingers/blood supply , Hemodynamics/radiation effects , Humans , Laser-Doppler Flowmetry , Male , Microcirculation/physiology , Middle Aged , Pilot Projects , Skin/blood supply , Young Adult
16.
Interface Focus ; 1(1): 61-74, 2011 Feb 06.
Article in English | MEDLINE | ID: mdl-22419974

ABSTRACT

Electric stimulation has been investigated for several decades to treat, with various degrees of success, a broad spectrum of neurological disorders. Historically, the development of these methods has been largely empirical but has led to a remarkably efficient, yet invasive treatment: deep brain stimulation (DBS). However, the efficiency of DBS is limited by our lack of understanding of the underlying physiological mechanisms and by the complex relationship existing between brain processing and behaviour. Biophysical modelling of brain activity, describing multi-scale spatio-temporal patterns of neuronal activity using a mathematical model and taking into account the physical properties of brain tissue, represents one way to fill this gap. In this review, we illustrate how biophysical modelling is beginning to emerge as a driving force orienting the development of innovative brain stimulation methods that may move DBS forward. We present examples of modelling works that have provided fruitful insights in regards to DBS underlying mechanisms, and others that also suggest potential improvements for this neurosurgical procedure. The reviewed literature emphasizes that biophysical modelling is a valuable tool to assist a rational development of electrical and/or magnetic brain stimulation methods tailored to both the disease and the patient's characteristics.

17.
Article in English | MEDLINE | ID: mdl-20730081

ABSTRACT

We propose a new method for selective modulation of cortical rhythms based on neural field theory, in which the activity of a cortical area is extensively monitored using a two-dimensional microelectrode array. The example of Parkinson's disease illustrates the proposed method, in which a neural field model is assumed to accurately describe experimentally recorded activity. In addition, we propose a new closed-loop stimulation signal that is both space- and time- dependent. This method is especially designed to specifically modulate a targeted brain rhythm, without interfering with other rhythms. A new class of neuroprosthetic devices is also proposed, in which the multielectrode array is seen as an artificial neural network interacting with biological tissue. Such a bio-inspired approach may provide a solution to optimize interactions between the stimulation device and the cortex aiming to attenuate or augment specific cortical rhythms. The next step will be to validate this new approach experimentally in patients with Parkinson's disease.

19.
Int Arch Occup Environ Health ; 83(4): 441-54, 2010 Apr.
Article in English | MEDLINE | ID: mdl-19902234

ABSTRACT

PURPOSE: Previously published literature has suggested an effect of extremely low-frequency (ELF) magnetic fields (MF) on human heart rate (HR) and heart rate variability (HRV). The combined response of the microcirculation and macrocirculation to ELF MF exposure has not previously been studied in humans. This study investigated the effects of 1-h exposure to an 1800-muT, 60-Hz MF on human microcirculation (represented in this study as skin blood perfusion), HR, low-frequency HRV, and high-frequency HRV. METHODS: Fifty-eight volunteers were recruited to partake in a double-blinded, counterbalanced study consisting of two testing sessions (real and sham) administered on separate days. Each session included four consecutive blocks of measurements, separated by 15-min rest periods, allowing measurement of cumulative and residual MF effects. Within subjects, ANOVA were conducted on each of the measured parameters. RESULTS: A decrease of skin blood perfusion and HR, and an increase of HRV were observed over blocks (p < 0.05). No session by block interactions were found for any of the cardiovascular parameters which would have suggested a MF effect (p > 0.05). A session by block interaction (p < 0.001) and a MF order effect (sham or real exposure first, p < 0.05) were observed for skin surface temperature. CONCLUSIONS: The MF used in this experiment did not affect cardiovascular parameters. Although an alternative explanation for why skin surface temperatures decreased in the sham and not in the real exposure condition is presented, the possibility of a MF effect cannot be excluded.


Subject(s)
Electromagnetic Fields/adverse effects , Heart Rate/radiation effects , Microcirculation/radiation effects , Adolescent , Adult , Double-Blind Method , Female , Humans , Male , Middle Aged , Young Adult
20.
Int Arch Occup Environ Health ; 82(8): 919-33, 2009 Aug.
Article in English | MEDLINE | ID: mdl-19221783

ABSTRACT

The effects of exposure to extremely low frequency (ELF) electromagnetic fields (EMFs) on human cardiovascular parameters remain undetermined. Epidemiological studies have utilized dosimetry estimations of employee workplace exposure using altered heart rate variability (HRV) as predictive of certain cardiovascular pathologies. Laboratory studies have focused on macrocirculatory indicators including heart rate, HRV and blood pressure. Few studies have been conducted on the response of the microcirculatory system to EMF exposure. Attempts to replicate both epidemiological and laboratory studies have been mostly unsuccessful as study design, small sample populations and confounding variables have hampered progress to date. Identification of these problems, in the current context of international exposure guideline re-evaluation, is essential for future EMF studies. These studies should address the possible deleterious health effects of EMFs as well as the detection and characterization of subtle physiological changes they may induce. Recommendations for future work include investigating the macro- and microcirculatory relationship and the use of laboratory geomagnetic shielding.


Subject(s)
Cardiovascular Diseases/etiology , Cardiovascular System/radiation effects , Electromagnetic Fields/adverse effects , Heart Rate/radiation effects , Blood Pressure/radiation effects , Cardiovascular System/physiopathology , Humans , Occupational Diseases/etiology , Occupational Diseases/physiopathology , Occupational Exposure/adverse effects
SELECTION OF CITATIONS
SEARCH DETAIL
...