Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 3 de 3
1.
Am Surg ; 90(6): 1497-1500, 2024 Jun.
Article En | MEDLINE | ID: mdl-38557117

INTRODUCTION: Collaboration between the health care industry and surgeons is critical in modern medicine. Conflict of interest (COI) has the risk of introducing bias into research studies. We investigated the accuracy of self-disclosed COI for studies that researched the use of microwave ablation for liver metastasis. METHODS: A literature search identified studies that investigated the use of microwave ablation for liver cancer between 2016 and 2022. We utilized the Open Payments Database to query individual authors' financial contributions from the industry. The accuracy of the disclosure statement and financial contribution for each study and author was calculated. We compared the amount of financial contribution authors received based on the accuracy of their COI statement. RESULTS: Twenty-five studies of interest were identified. The mean number of authors was 8.24. A disclosure statement was present in 52% of studies. Of those, 28% had an incongruent disclosure statement. 9/25 (36%) of studies had a conflict of interest based on financial payments provided by industry. Overall, authors received an average of $440,483.41 (SD $1,889,375.34). We did not find a difference in the financial contribution's value based on the disclosure statement's accuracy (P = .55). CONCLUSIONS: Over a quarter of studies in our review of microwave ablation literature had discrepancies in the reporting of conflicts of interest, highlighting the need for improved reporting of potential conflicts of interest to protect the integrity of clinical research. Compared to other fields of surgery, we found a lower rate of undisclosed COI, suggesting that the scope of cancer-directed surgery may be more resistant to industry influence.


Conflict of Interest , Liver Neoplasms , Humans , Liver Neoplasms/surgery , Liver Neoplasms/secondary , Microwaves/therapeutic use , Disclosure/ethics , Ablation Techniques/ethics , Ablation Techniques/economics
2.
Anesthesiology ; 139(6): 815-826, 2023 12 01.
Article En | MEDLINE | ID: mdl-37566686

BACKGROUND: Bedside electrical impedance tomography could be useful to visualize evolving pulmonary perfusion distributions when acute respiratory distress syndrome worsens or in response to ventilatory and positional therapies. In experimental acute respiratory distress syndrome, this study evaluated the agreement of electrical impedance tomography and dynamic contrast-enhanced computed tomography perfusion distributions at two injury time points and in response to increased positive end-expiratory pressure (PEEP) and prone position. METHODS: Eleven mechanically ventilated (VT 8 ml · kg-1) Yorkshire pigs (five male, six female) received bronchial hydrochloric acid (3.5 ml · kg-1) to invoke lung injury. Electrical impedance tomography and computed tomography perfusion images were obtained at 2 h (early injury) and 24 h (late injury) after injury in supine position with PEEP 5 and 10 cm H2O. In eight animals, electrical impedance tomography and computed tomography perfusion imaging were also conducted in the prone position. Electrical impedance tomography perfusion (QEIT) and computed tomography perfusion (QCT) values (as percentages of image total) were compared in eight vertical regions across injury stages, levels of PEEP, and body positions using mixed-effects linear regression. The primary outcome was agreement between QEIT and QCT, defined using limits of agreement and Pearson correlation coefficient. RESULTS: Pao2/Fio2 decreased over the course of the experiment (healthy to early injury, -253 [95% CI, -317 to -189]; early to late injury, -88 [95% CI, -151 to -24]). The limits of agreement between QEIT and QCT were -4.66% and 4.73% for the middle 50% quantile of average regional perfusion, and the correlation coefficient was 0.88 (95% CI, 0.86 to 0.90]; P < 0.001). Electrical impedance tomography and computed tomography showed similar perfusion redistributions over injury stages and in response to increased PEEP. QEIT redistributions after positional therapy underestimated QCT in ventral regions and overestimated QCT in dorsal regions. CONCLUSIONS: Electrical impedance tomography closely approximated computed tomography perfusion measures in experimental acute respiratory distress syndrome, in the supine position, over injury progression and with increased PEEP. Further validation is needed to determine the accuracy of electrical impedance tomography in measuring perfusion redistributions after positional changes.


Respiratory Distress Syndrome , Tomography, X-Ray Computed , Male , Female , Swine , Animals , Electric Impedance , Respiratory Distress Syndrome/therapy , Lung , Perfusion , Tomography/methods
3.
Crit Care Med ; 49(10): e1015-e1024, 2021 10 01.
Article En | MEDLINE | ID: mdl-33938714

OBJECTIVES: It is not known how lung injury progression during mechanical ventilation modifies pulmonary responses to prone positioning. We compared the effects of prone positioning on regional lung aeration in late versus early stages of lung injury. DESIGN: Prospective, longitudinal imaging study. SETTING: Research imaging facility at The University of Pennsylvania (Philadelphia, PA) and Medical and Surgical ICUs at Massachusetts General Hospital (Boston, MA). SUBJECTS: Anesthetized swine and patients with acute respiratory distress syndrome (acute respiratory distress syndrome). INTERVENTIONS: Lung injury was induced by bronchial hydrochloric acid (3.5 mL/kg) in 10 ventilated Yorkshire pigs and worsened by supine nonprotective ventilation for 24 hours. Whole-lung CT was performed 2 hours after hydrochloric acid (Day 1) in both prone and supine positions and repeated at 24 hours (Day 2). Prone and supine images were registered (superimposed) in pairs to measure the effects of positioning on the aeration of each tissue unit. Two patients with early acute respiratory distress syndrome were compared with two patients with late acute respiratory distress syndrome, using electrical impedance tomography to measure the effects of body position on regional lung mechanics. MEASUREMENTS AND MAIN RESULTS: Gas exchange and respiratory mechanics worsened over 24 hours, indicating lung injury progression. On Day 1, prone positioning reinflated 18.9% ± 5.2% of lung mass in the posterior lung regions. On Day 2, position-associated dorsal reinflation was reduced to 7.3% ± 1.5% (p < 0.05 vs Day 1). Prone positioning decreased aeration in the anterior lungs on both days. Although prone positioning improved posterior lung compliance in the early acute respiratory distress syndrome patients, it had no effect in late acute respiratory distress syndrome subjects. CONCLUSIONS: The effects of prone positioning on lung aeration may depend on the stage of lung injury and duration of prior ventilation; this may limit the clinical efficacy of this treatment if applied late.


Lung Injury/complications , Prone Position/physiology , Adult , Aged , Boston , Female , Humans , Longitudinal Studies , Lung Injury/diagnostic imaging , Lung Injury/physiopathology , Male , Middle Aged , Pennsylvania , Positive-Pressure Respiration/methods , Prospective Studies , Treatment Outcome
...