Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters











Database
Language
Publication year range
1.
Herz ; 36(7): 592-9, 2011 Oct.
Article in English | MEDLINE | ID: mdl-21922233

ABSTRACT

BACKGROUND: Optimization of AV and VV delay programming has been shown to be essential for the success of cardiac resynchronization therapy (CRT). Acute hemodynamic improvement can be obtained by intracardiac electrocardiogram (IEGM)-based optimization. The aim of the present study was to evaluate whether this IEGM-based algorithm is comparable to the current gold standard of echocardiography. METHODS: After device implantation patients with standard criteria for CRT, AV and VV delay programming was either optimized by an IEGM-based algorithm (IEGM group, n = 24) or by echocardiography (echo group, n = 24). Cardiopulmonary exercise capacity was assessed after 3 and 12 months on the basis of NYHA class and the 6-min-walk test. Left ventricular ejection fraction was evaluated by echocardiography. RESULTS: In both groups there was a significant decrease in NYHA class and a significant increase in 6-min-walk distance and ejection fraction after 3 and 12 months. After 12 months there was no significant difference in the proportion of responders, NYHA class and 6-min-walk distance between the IEGM the echo group. CONCLUSION: The present data show that a sustained improvement of cardiopulmonary exercise capacity can be obtained by optimizing CRT patients on the basis of an IEGM algorithm. The comparable results for cardiopulmonary exercise parameters suggest that this new method might become an important tool for adjusting CRT programming in daily practice.


Subject(s)
Cardiac Resynchronization Therapy/methods , Echocardiography/methods , Electrocardiography/methods , Heart Failure/therapy , Signal Processing, Computer-Assisted , Aged , Algorithms , Bundle-Branch Block/mortality , Bundle-Branch Block/physiopathology , Bundle-Branch Block/therapy , Cardiac Resynchronization Therapy Devices , Echocardiography/instrumentation , Electrocardiography/instrumentation , Electrodes, Implanted , Equipment Design , Exercise Test , Female , Follow-Up Studies , Heart Atria/physiopathology , Heart Failure/mortality , Heart Failure/physiopathology , Heart Ventricles/physiopathology , Hemodynamics/physiology , Humans , Male , Middle Aged , Signal Processing, Computer-Assisted/instrumentation , Software , Survival Rate , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL