Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
PLoS One ; 19(5): e0302159, 2024.
Article in English | MEDLINE | ID: mdl-38713665

ABSTRACT

BACKGROUND: Stroke volume can be estimated beat-to-beat and non-invasively by pulse wave analysis (PWA). However, its reliability has been questioned during marked alterations in systemic vascular resistance (SVR). We studied the effect of SVR on the agreement between stroke volume by PWA and Doppler ultrasound during reductions in stroke volume in healthy volunteers. METHODS: In a previous study we simultaneously measured stroke volume by PWA (SVPWA) and suprasternal Doppler ultrasound (SVUS). We exposed 16 healthy volunteers to lower body negative pressure (LBNP) to reduce stroke volume in combination with isometric hand grip to elevate SVR. LBNP was increased by 20 mmHg every 6 minutes from 0 to 80 mmHg, or until hemodynamic decompensation. The agreement between SVPWA and SVUS was examined using Bland-Altman analysis with mixed regression. Within-subject limits of agreement (LOA) was calculated from the residual standard deviation. SVRUS was calculated from SVUS. We allowed for a sloped bias line by introducing the mean of the methods and SVRUS as explanatory variables to examine whether the agreement was dependent on the magnitude of stroke volume and SVRUS. RESULTS: Bias ± limits of agreement (LOA) was 27.0 ± 30.1 mL. The within-subject LOA was ±11.1 mL. The within-subject percentage error was 14.6%. The difference between methods decreased with higher means of the methods (-0.15 mL/mL, confidence interval (CI): -0.19 to -0.11, P<0.001). The difference between methods increased with higher SVRUS (0.60 mL/mmHg × min × L-1, 95% CI: 0.48 to 0.72, P<0.001). CONCLUSION: PWA overestimated stroke volume compared to Doppler ultrasound during reductions in stroke volume and elevated SVR in healthy volunteers. The agreement between SVPWA and SVUS decreased during increases in SVR. This is relevant in settings where a high level of reliability is required.


Subject(s)
Healthy Volunteers , Pulse Wave Analysis , Stroke Volume , Ultrasonography, Doppler , Vascular Resistance , Humans , Male , Vascular Resistance/physiology , Adult , Female , Ultrasonography, Doppler/methods , Stroke Volume/physiology , Pulse Wave Analysis/methods , Young Adult , Lower Body Negative Pressure , Hand Strength/physiology , Reproducibility of Results
2.
Intensive Care Med Exp ; 11(1): 76, 2023 Nov 10.
Article in English | MEDLINE | ID: mdl-37947905

ABSTRACT

BACKGROUND: Trauma patients frequently receive supplemental oxygen, but its hemodynamic effects in blood loss are poorly understood. We studied the effects of oxygen on the hemodynamic response and tolerance to simulated blood loss in healthy volunteers. METHODS: Fifteen healthy volunteers were exposed to simulated blood loss by lower body negative pressure (LBNP) on two separate visits at least 24 h apart. They were randomized to inhale 100% oxygen or medical air on visit 1, while inhaling the other on visit 2. To simulate progressive blood loss LBNP was increased every 3 min in levels of 10 mmHg from 0 to 80 mmHg or until hemodynamic decompensation. Oxygen and air were delivered on a reservoired face mask at 15 L/min. The effect of oxygen compared to air on the changes in cardiac output, stroke volume and middle cerebral artery blood velocity (MCAV) was examined with mixed regression to account for repeated measurements within subjects. The effect of oxygen compared to air on the tolerance to blood loss was measured as the time to hemodynamic decompensation in a shared frailty model. Cardiac output was the primary outcome variable. RESULTS: Oxygen had no statistically significant effect on the changes in cardiac output (0.031 L/min/LBNP level, 95% confidence interval (CI): - 0.015 to 0.077, P = 0.188), stroke volume (0.39 mL/LBNP level, 95% CI: - 0.39 to 1.2, P = 0.383), or MCAV (0.25 cm/s/LBNP level, 95% CI: - 0.11 to 0.61, P = 0.176). Four subjects exhibited hemodynamic decompensation when inhaling oxygen compared to 10 when inhaling air (proportional hazard ratio 0.24, 95% CI: 0.065 to 0.85, P = 0.027). CONCLUSIONS: We found no effect of oxygen compared to air on the changes in cardiac output, stroke volume or MCAV during simulated blood loss in healthy volunteers. However, oxygen had a favorable effect on the tolerance to simulated blood loss with fewer hemodynamic decompensations. Our findings suggest that supplemental oxygen does not adversely affect the hemodynamic response to simulated blood loss. Trial registration This trial was registered in ClinicalTrials.gov (NCT05150418) December 9, 2021.

3.
PLoS One ; 17(6): e0270598, 2022.
Article in English | MEDLINE | ID: mdl-35749486

ABSTRACT

Supplemental oxygen is widely administered in trauma patients, often leading to hyperoxia. However, the clinical evidence for providing supplemental oxygen in all trauma patients is scarce, and hyperoxia has been found to increase mortality in some patient populations. Hypovolemia is a common finding in trauma patients, which affects many hemodynamic parameters, but little is known about how supplemental oxygen affects systemic and cerebral hemodynamics during hypovolemia. We therefore plan to conduct an experimental, randomized, double blinded crossover study to investigate the effect of 100% oxygen compared to room air delivered by a face mask with reservoir on systemic and cerebral hemodynamics during simulated hypovolemia in the lower body negative pressure model in 15 healthy volunteers. We will measure cardiac output, stroke volume, blood pressure, middle cerebral artery velocity and tolerance to hypovolemia continuously in all subjects at two visits to investigate whether oxygen affects the cardiovascular response to simulated hypovolemia. The effect of oxygen on the outcome variables will be analyzed with mixed linear regression. Trial registration: The study is registered in the European Union Drug Regulating Authorities Clinical Trials Database (EudraCT, registration number 2021-003238-35).


Subject(s)
Hyperoxia , Hypovolemia , Cross-Over Studies , Hemodynamics/physiology , Humans , Oxygen , Randomized Controlled Trials as Topic
4.
Eur J Appl Physiol ; 121(8): 2207-2217, 2021 Aug.
Article in English | MEDLINE | ID: mdl-33890157

ABSTRACT

PURPOSE: Cerebral blood flow (CBF) needs to be precisely controlled to maintain brain functions. While previously believed to be autoregulated and near constant over a wide blood pressure range, CBF is now understood as more pressure passive. However, there are still questions regarding the integrated nature of CBF regulation and more specifically the role of cardiac output. Our aim was, therefore, to explore the effects of MAP and cardiac output on CBF in a combined model of reduced preload and increased afterload. METHOD: 16 healthy volunteers were exposed to combinations of different levels of simultaneous lower body negative pressure and isometric hand grip. We measured blood velocity in the middle cerebral artery (MCAV) and internal carotid artery (ICAV) by Doppler ultrasound, and cerebral oxygen saturation (ScO2) by near-infrared spectroscopy, as surrogates for CBF. The effect of changes in MAP and cardiac output on CBF was estimated with mixed multiple regression. RESULT: Both MAP and cardiac output had independent effects on MCAV, ICAV and ScO2. For ICAV and ScO2 there was also a statistically significant interaction effect between MAP and cardiac output. The estimated effect of a change of 10 mmHg in MAP on MCAV was 3.11 cm/s (95% CI 2.51-3.71, P < 0.001), and the effect of a change of 1 L/min in cardiac output was 3.41 cm/s (95% CI 2.82-4.00, P < 0.001). CONCLUSION: The present study indicates that during reductions in cardiac output, both MAP and cardiac output have independent effects on CBF.


Subject(s)
Blood Flow Velocity/physiology , Blood Pressure/physiology , Cardiac Output/physiology , Cerebrovascular Circulation/physiology , Adult , Female , Hand Strength/physiology , Healthy Volunteers , Humans , Male , Spectroscopy, Near-Infrared , Ultrasonography, Doppler
5.
BMJ Open Ophthalmol ; 5(1): e000545, 2020.
Article in English | MEDLINE | ID: mdl-32995498

ABSTRACT

OBJECTIVE: To determine the effect of povidone iodine (PI), an antiseptic commonly used prior to ocular surgery, on viability of mixed populations of conjunctival stratified squamous and goblet cells, purified conjunctival goblet cells and purified conjunctival stromal fibroblasts in primary culture. METHODS AND ANALYSIS: Mixed population of epithelial cells (stratified squamous and goblet cells), goblet cells and fibroblasts were grown in culture from pieces of human conjunctiva using either supplemented DMEM/F12 or RPMI. Cell type was evaluated by immunofluorescence microscopy. Cells were treated for 5 min with phosphate-buffered saline (PBS); 0.25%, 2.5%, 5% or 10% PI in PBS; or a positive control of 30% H2O2. Cell viability was determined using Alamar Blue fluorescence and a live/dead kit using calcein/AM and ethidium homodimer-1 (EH-1). RESULTS: Mixed populations of epithelial cells, goblet cells and fibroblasts were characterised by immunofluorescence microscopy. As determined with Alamar Blue fluorescence, all concentrations of PI significantly decreased the number of cells from all three preparation types compared with PBS. As determined by calcein/EH-1 viability test, mixed populations of cells and fibroblasts were less sensitive to PI treatment than goblet cells. All concentrations of PI, except for 0.25% used with goblet cells, substantially increased the number of dead cells for all cell populations. The H2O2 control also significantly decreased the number and viability of all three types of cells in both tests. CONCLUSION: We conclude that PI, which is commonly used prior to ocular surgeries, is detrimental to human conjunctival stratified squamous cells, goblet cells and fibroblasts in culture.

SELECTION OF CITATIONS
SEARCH DETAIL