Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 3 de 3
1.
Opt Express ; 23(7): A232-9, 2015 Apr 06.
Article En | MEDLINE | ID: mdl-25968789

We present a trichromatic GaN-based light-emitting diode (LED) that emits near-ultraviolet (n-UV) blue and green peaks combined with red phosphor to generate white light with a low correlated color temperature (CCT) and high color rendering index (CRI). The LED structure, blue and green unipolar InGaN/GaN multiple quantum wells (MQWs) stacked with a top p-i-n structure containing an InGaN/GaN MQW emitting n-UV light, was grown epitaxially on a single substrate. The trichromatic LED chips feature a vertical conduction structure on a silicon substrate fabricated through wafer bonding and laser lift-off techniques. The blue and green InGaN/GaN MQWs were pumped with n-UV light to re-emit low-energy photons when the LEDs were electrically driven with a forward current. The emission spectrum included three peaks at approximately 405, 468, and 537 nm. Furthermore, the trichromatic LED chips were combined with red phosphor to generate white light with a CCT and CRI of approximately 2900 and 92, respectively.

2.
Opt Express ; 23(7): A371-81, 2015 Apr 06.
Article En | MEDLINE | ID: mdl-25968802

A p-i-n structure with near-UV(n-UV) emitting InGaN/GaN multiple quantum well(MQW) structure stacked on a green unipolar InGaN/GaN MQW was epitaxially grown at the same sapphire substrate. Photon recycling green light-emitting diodes(LEDs) with vertical-conduction feature on silicon substrates were then fabricated by wafer bonding and laser lift-off techniques. The green InGaN/GaN QWs were pumped with n-UV light to reemit low-energy photons when the LEDs were electrically driven with a forward current. Efficiency droop is potentially insignificant compared with the direct green LEDs due to the increase of effective volume of active layer in the optically pumped green LEDs, i.e., light emitting no longer limited in the QWs nearest to the p-type region to cause severe Auger recombination and carrier overflow losses.

3.
Environ Sci Technol ; 46(8): 4546-52, 2012 Apr 17.
Article En | MEDLINE | ID: mdl-22435654

A novel active personal nanoparticle sampler (PENS), which enables the collection of both respirable particulate mass (RPM) and nanoparticles (NPs) simultaneously, was developed to meet the critical demand for personal sampling of engineered nanomaterials (ENMs) in workplaces. The PENS consists of a respirable cyclone and a micro-orifice impactor with the cutoff aerodynamic diameter (d(pa50)) of 4 µm and 100 nm, respectively. The micro-orifice impactor has a fixed micro-orifice plate (137 nozzles of 55 µm in the inner diameter) and a rotating, silicone oil-coated Teflon filter substrate at 1 rpm to achieve a uniform particle deposition and avoid solid particle bounce. A final filter is used after the impactor to collect the NPs. Calibration results show that the d(pa50) of the respirable cyclone and the micro-orifice impactor are 3.92 ± 0.22 µm and 101.4 ± 0.1 nm, respectively. The d(pa50) at the loaded micro-Al(2)O(3) mass of 0.36-3.18 mg is shifted to 102.9-101.2 nm, respectively, while it is shifted to 98.9-97.8 nm at the loaded nano-TiO(2) mass of 0.92-1.78 mg, respectively. That is, the shift of d(pa50) due to solid particle loading is small if the PENS is not overloaded. Both NPs and RPM concentrations were found to agree well with those of the IOSH respirable cyclone and MOUDI. By using the present PENS, the collected samples can be further analyzed for chemical species concentrations besides gravimetric analysis to determine the actual exposure concentrations of ENMs in both RPM and NPs fractions in workplaces, which are often influenced by the background or incident pollution sources.


Air Pollutants, Occupational/analysis , Environmental Monitoring/instrumentation , Inhalation Exposure/analysis , Nanoparticles/analysis , Occupational Exposure/analysis , Environmental Monitoring/methods , Humans , Workplace
...