Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters











Database
Language
Publication year range
1.
Quant Imaging Med Surg ; 13(5): 3066-3079, 2023 May 01.
Article in English | MEDLINE | ID: mdl-37179922

ABSTRACT

Background: The precise assessment of the perforators of the fibula free flap (FFF) is crucial for minimizing procedure-related complications when harvesting the FFF in patients with maxillofacial lesions. This study aims to investigate the utility of virtual noncontrast (VNC) images for radiation dose saving and to determine the optimal energy level of virtual monoenergetic imaging (VMI) reconstructions in dual-energy computed tomography (DECT) for visualization of the perforators of the fibula free flap (FFF). Methods: Data from 40 patients with maxillofacial lesions who received lower extremity DECT examinations in the noncontrast and arterial phase were collected in this retrospective, cross-sectional study. To compare VNC images from the arterial phase with true non-contrast images in a DECT protocol (M_0.5-TNC) and to compare VMI images with 0.5 linear images blending from the arterial phase (M_0.5-C), the attenuation, noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and subjective image quality were assessed in different arteries, muscles, and fat tissues. Two readers evaluated the image quality and visualization of the perforators. The dose-length product (DLP) and CT volume dose index (CTDIvol) were used to determine the radiation dose. Results: Objective and subjective analyses showed no significant difference between the M_0.5-TNC and VNC images in the arteries and muscles (P>0.09 to P>0.99), and VNC imaging could reduce 50% of the radiation dose (P<0.001). Compared with those of the M_0.5-C images, the attenuation and CNR of VMI reconstructions at 40 kiloelectron volt (keV) and 60 keV were higher (P<0.001 to P=0.04). Noise was similar at 60 keV (all P>0.99) and increased at 40 keV (all P<0.001), and the SNR in arteries was increased at 60 keV (P<0.001 to P=0.02) in VMI reconstructions compared with those in the M_0.5-C images. The subjective scores in VMI reconstructions at 40 and 60 keV was higher than those in M_0.5-C images (all P<0.001). The image quality at 60 keV was superior to that at 40 keV (P<0.001), and there was no difference in the visualization of the perforators between 40 and 60 keV (P=0.31). Conclusions: VNC imaging is a reliable technique for replacing M_0.5-TNC and provides radiation dose saving. The image quality of the 40-keV and 60-keV VMI reconstructions was higher than that of the M_0.5-C images, and 60 keV provided the best assessment of perforators in the tibia.

2.
Eur J Radiol ; 164: 110877, 2023 Jul.
Article in English | MEDLINE | ID: mdl-37187079

ABSTRACT

PURPOSE: To investigate the improvement of image quality and visualization of fibula-free flap (FFF) perforators on computed tomography angiography (CTA) after administration of sublingual nitroglycerin (NTG) tablets. METHODS: A total of 60 patients with oral or maxillofacial lesions before CTA of the lower extremity were randomly divided into two groups (NTG group and non-NTG group). The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR), overall image quality and grading of vessels were evaluated and compared. The lumen diameters of the major arteries and the proximal and distal peroneal perforators were measured. The number of visible perforators in muscular clearance and muscular layer was also counted and compared between the two groups. RESULTS: The CNR of posterior tibial artery and overall image quality of CTA images in the NTG group was significantly higher than that in the non-NTG group (p < 0.05), although the SNR and CNR of other arteries did not show significant differences (p > 0.05). The lumen diameters of the peroneal artery and its perforators, anterior tibial artery, and posterior tibial artery were significantly larger in the NTG group (p < 0.001), while no significant difference prevailed in the diameter of the popliteal artery between the two groups (p = 0.298). Compared with the non-NTG group, a significant increase in the number of visible perforators was noted in the NTG group (p < 0.001). CONCLUSIONS: The administration of sublingual NTG in CTA of the lower extremity can improve the image quality and visualization of perforators, which aids to surgeons select the optimum FFF.


Subject(s)
Free Tissue Flaps , Nitroglycerin , Humans , Computed Tomography Angiography , Tomography, X-Ray Computed/methods , Angiography/methods
3.
Tomography ; 9(2): 485-496, 2023 02 23.
Article in English | MEDLINE | ID: mdl-36960999

ABSTRACT

(1) Background: This study explored the optimal energy level in advanced virtual monoenergetic images (VMI+) from dual-energy computed tomography angiography (DE-CTA) for adrenal veins visualization before adrenal venous sampling (AVS). (2) Methods: Thirty-nine patients were included in this prospective single-center study. The CT value, noise, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were measured in both adrenal veins and abdominal solid organs and were then compared between VMI+ within the range of 40-80 kiloelectron volt (keV). The visualization rate of the adrenal veins and the overall image quality of solid organs were subjectively compared among different keV VMI+. The AVS success rate was recorded for 20 patients. (3) Results: For the adrenal veins, 40 keV VMI+ had the peak CT value, noise and CNR (p < 0.05). Subjectively, the visualization rate was the highest at 40 keV (100% for the right adrenal vein, and 97.4% for the left adrenal vein) (p < 0.05). For solid organs, the CT value, noise and CNR at 50 keV were lower than those at 40 keV (p < 0.05), but the SNR was similar between 40 keV and 50 keV. The overall subjective image quality of solid organs at 50 keV was the best (p < 0.05). The AVS success rate was 95%. (4) Conclusions: For VMI+, 40 keV was the preferential energy level to obtain a high visualization rate of the adrenal veins and a high success rate of AVS, while 50 keV was the favorable energy level for the depiction of abdominal organs.


Subject(s)
Radiography, Dual-Energy Scanned Projection , Humans , Prospective Studies , Radiography, Dual-Energy Scanned Projection/methods , Algorithms , Retrospective Studies , Tomography, X-Ray Computed/methods
4.
Front Oncol ; 12: 904471, 2022.
Article in English | MEDLINE | ID: mdl-35814448

ABSTRACT

Objectives: To determine whether quantitative parameters derived from dual-energy computed tomography (DECT) were predictive of the aggressiveness of oral tongue squamous cell carcinoma (OTSCC) including the pathologic stages, histologic differentiation, lymph node status, and perineural invasion (PNI). Methods: Between August 2019 and March 2021, 93 patients (mean age, 54.6 ± 13.8 years; 66 men) with pathologically diagnosed OTSCC were enrolled in this prospective study. Preoperative DECT was performed and quantitative parameters (e.g., slope of the spectral Hounsfield unit curve [λHu], normalized iodine concentration [nIC], normalized effective atomic number [nZeff], and normalized electron density [nRho]) were measured on arterial phase (AP) and venous phase (VP) DECT imaging. Quantitative parameters from DECT were compared between patients with different pathologic stages, histologic differentiation, lymph node statuses, and perineural invasion statuses. Logistic regression analysis was utilized to assess independent parameters and the diagnostic performance was analyzed by the receiver operating characteristic curves (ROC). Results: λHu and nIC in AP and λHu, nZeff, and nIC in VP were significantly lower in stage III-IV lesions than in stage I-II lesions (p < 0.001 to 0.024). λHu in VP was an independent predictor of tumor stage with an odds ratio (OR) of 0.29, and area under the curve (AUC) of 0.80. λHu and nIC were higher in well-differentiated lesions than in poorly differentiated lesions (p < 0.001 to 0.021). The nIC in VP was an independent predictor of histologic differentiation with OR of 0.31, and AUC of 0.78. λHu and nIC in VP were lower in OTSCCs with lymph node metastasis than those without metastasis (p < 0.001 to 0.005). λHu in VP was the independent predictor of lymph node status with OR of 0.42, and AUC of 0.74. No significant difference was found between OTSCCs without PNI and those with PNI in terms of the quantitative DECT parameters. Conclusion: DECT can be a complementary means for the preoperative prediction of the aggressiveness of OTSCC.

5.
Chin J Integr Med ; 27(4): 252-258, 2021 Apr.
Article in English | MEDLINE | ID: mdl-33037518

ABSTRACT

OBJECTIVE: To evaluate whether the efficacy of Getong Tongluo Capsule (, GTC, consisted of total flavone of Radix Puerariae) on improving patients' quality of life and lowering blood pressure are superior to the extract of Ginkgo biloba (EGB) for patients with convalescent-phase ischemic stroke and primary hypertension. METHODS: This randomized, positive-drug- and placebo-controlled, double-blind trial was conducted from September 2015 to October 2017. Totally 477 eligible patients from 18 hospitals in China were randomly assigned in a 2:1:1 ratio to the following interventions, twice a day for 12 weeks: (1) GTC 250 mg plus EGB-matching placebo 40 mg (237 cases, GTC group), (2) EGB 40 mg plus GTC-matching placebo 250 mg (120 cases, EGB group) or (3) GTC-matching placebo 250 mg plus EGB-matching placebo 40 mg (120 cases, placebo group). Moreover, all patients were orally administered aspirin enteric-coated tablets 100 mg, once a day for 12 weeks. The primary outcome was the Barthel Index (BI). The secondary outcomes included the control rate of blood pressure and National Institutes of Health Stroke Scale (NIHSS) scores. The incidence and severity of adverse events (AEs) were calculated and assessed. RESULTS: The BI relative independence rates, the clinical recovery rates of NIHSS, and the total effective rates of NIHSS in the GTC and EGB groups were significantly higher than the placebo group at 12 weeks after treatment (P<0.05), and no statistical significance was found between the GTC and EGB groups (P>0.05). The control rate of blood pressure in the GTC group was significantly higher than the EGB and placebo groups at 12, 18 and 24 weeks after treatment (P<0.01). There were no statistically significant differences in the incidences of AEs, adverse drug reactions, or serious AEs among the 3 groups (P>0.05). CONCLUSION: GTC exhibited significant efficacy in improving patients' quality of life as well as neurological function and controlling hypertension. (Registration No. ChiCTR1800016667).


Subject(s)
Brain Ischemia , Drugs, Chinese Herbal/therapeutic use , Hypertension , Ischemic Stroke , Brain Ischemia/drug therapy , Capsules , Double-Blind Method , Humans , Hypertension/drug therapy , Quality of Life , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL