1.
J. res. dent ; 4(1): 4-8, jan.-feb2016.
Article in English | LILACS-Express | LILACS | ID: biblio-1362972

ABSTRACT

Aim: A cross-sectional questionnaire survey was conducted to obtain information on the use of rotary nickel ­titanium endodontic instruments was conducted among General Dental Practioner A two sectioned questionnaire was mailed to 200 randomly general practioners to obtain information on usage of Nickel ­Titanium endodontic instrument and data was collected. Results: Forty-six percent of the general practioners had used rotary NiTi instruments. 76% dentists use NiTi files for five or more times a week. Most of the dentist used NiTi file coronally &apically. General dentists experienced more file fracture at size 20 and 25 with 0.02 and 0.04 taper. Conclusions: Dentists are familiar with limitations of NiTi instruments and techniques. Current study showed the awareness of dentists about benefits of NiTi rotary instruments application comparing to traditional techniques and also the high percent usage of these instruments among general dentists.

2.
Int J Clin Pediatr Dent ; 9(4): 303-307, 2016.
Article in English | MEDLINE | ID: mdl-28127160

ABSTRACT

AIM: To evaluate the incidence of apical crack initiation during canal preparation with stainless steel K-files and hand protaper files (in vitro study). MATERIALS AND METHODS: Sixty extracted mandibular premo-lar teeth are randomly selected and embedded in an acrylic tube filled with autopolymerizing resin. A baseline image of the apical surface of each specimen was recorded under a digital microscope (80×). The cervical and middle thirds of all samples were flared with #2 and #1 Gates-Glidden (GG) drills, and a second image was recorded. The teeth were randomly divided into four groups of 15 teeth each according to the file type (hand K-file and hand-protaper) and working length (WL) (instrumented at WL and 1 mm less than WL). Final image after dye penetration and photomicrograph of the apical root surface were digitally recorded. RESULTS: Maximum numbers of cracks were observed with hand protaper files compared with hand K-file at the WL and 1 mm short of WL. Chi-square testing revealed a highly significant effect of WL on crack formation at WL and 1 mm short of WL (p = 0.000). CONCLUSION: Minimum numbers of cracks at WL and 1 mm short of WL were observed with hand K-file and maximum with hand protaper files. HOW TO CITE THIS ARTICLE: Soni D, Raisingani D, Mathur R, Madan N, Visnoi S. Incidence of Apical Crack Initiation during Canal Preparation using Hand Stainless Steel (K-File) and Hand NiTi (Protaper) Files. Int J Clin Pediatr Dent 2016;9(4):303-307.

SELECTION OF CITATIONS
SEARCH DETAIL